Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 CrAccepted-AOC STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹11.4 Cr | 1 | Accepted-AOC being L1 |
| 2 | 2₹11.5 CrRejected-Finance | ₹11.5 Cr | 2 | Rejected-Finance Being not L1 |
| 3 | 3₹11.5 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹11.5 Cr | 3 | Rejected-Finance Being not L1 |
| 4 | 4₹11.7 CrRejected-Finance | ₹11.7 Cr | 4 | Rejected-Finance Being not L1 |
| 5 | 5₹11.7 CrRejected-Finance | ₹11.7 Cr | 5 | Rejected-Finance Being not L1 |
Tender Value
₹12.8 Cr
EMD Value
₹9.6 L
Closing Date
27 Feb 2021, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE,JAIPUR
CONSTR OF 02 X IGLOO AT BHARATPUR
2020_MES_366258_2
CEJZ/NIT/BPR-02 OF 2020- 21
Open Tender
Civil Works
545 days
Bharatpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE Bharatpur
₹9.6 L
Yes
17 Mar 2021
5 Feb 2021
2 Mar 2021
5 Feb 2021
27 Feb 2021
15 Feb 2021
Amount
Lump sum price worked out by contractor for "Building works" as listed in Schedule `A' Part-I*Above/below the lump sum price inserted by the MES in Schedule `A' Part-I
Lump sum price worked out by contractor for "Igloo" as listed in Schedule `A' Part-II*Above/below the lump sum price inserted by the MES in Schedule `A' Part-II
Lump sum price worked out by the Contractor for "Internal Electrification" as listed in Schedule ‘A’ Part-III **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-III
Lump sum price worked out by contractor for "Road, Path and culvert" as listed in Schedule `A' Part-IV*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IV
Lump sum price worked out by contractor for "Area Drainage" as listed in Schedule `A' Part-V*Above/below the lump sum price inserted by the MES in Schedule `A' Part-V
Lump sum price worked out by contractor for "External water supply" as listed in Schedule `A' Part-VI*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VI
Lump sum price worked out by the Contractor for "External Electrification" as listed in Schedule ‘A’ Part-VII **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-VII
Lump sum price worked out by contractor for "Lightening Protection " as listed in Schedule `A' Part- VIII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VIII
Lump sum price worked out by contractor for "Site Clearance And Earth work" as listed in Schedule `A' Part-IX*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IX
Lump sum price worked out by contractor for "Fire Alarm" as listed in Schedule `A' Part-X*Above/below the lump sum price inserted by the MES in Schedule `A' Part-X
Lump sum price worked out by the Contractor for Schedule `A' Part-XI (rate against Srl No.11.01 to 11.34 shall be quoted by the Contractor)
Supply only FRGP hollow dunnage blocks size of 15" x 12" x 8" shall be made of chopped strand mat of density 450 gm/sqm reinforced with inter cellur FR plates conforming to IS-11551-1996. Surface should be smooth finish and colour approved by GE conform the manufracturer specifications and relevent codes complete as per direction of manufracturer and GE.
Sign board of size 1.20x1.20m on angle iron frame 40 x 40 x 6 mm and 3 mm thick plain sheet supported on 2.7 m high angle iron 65 x65 x6 mm fixed on PCC 1:2:4 block of size 1.50 x 0.45 x 0.45 m over 100 mm thick surface of PCC 1:4:8 including necessary earthwork complete and painting to steel surface and writing letter with reflective paint of height n exc. 15 cm and n exc 30 cm in each board complete.
Fiber reinforced, UV resistant, electrometric liquid applied water proofing & heat resistance coating with Acrylic polymer and polyester glass fiber as per manufracturer instruction upto the external height come in contact with earthy filling complete.
Material and labour for preparation of newly mild steel surface for applyling two coats of fire retardant intumscent paint using roller in required thickness (Total two coat applied thickness should not less than 200 micron) over one coat of fire retardant primer complete as manufacturer instructions / Recommendation with arrangement of scafolding etc to carryout and as directed by Engr-in-Charge.
M&L Preparation of new plastered surfaces and applying two coats of external emulsion paint (apex) over a coat of alkali resistant primer of approved camouflaging pattern and shade on walls.
Supply only approved soil as specified in particular specifications brought outside MoD land for forming embankment.
S&F 3mm dia wire netting of stainless steel wire with 50mm aperture fixed with tinned tacks of stainless steel wire staples complete all as specified.
Polythene film (white), 200 micron laid in floor over sand cushioning
M&L for antistatic flooring 2 mm thick with vinyl sheet homogenous conductive flooring in rolls after overlapping for uniformity and further sealing the joints by thermal welding process using conductive adhesive, all complete as specified. The antistatic flooring shall have conductive backing of thickness 0.2mm fixed with conductive adhesive over copper strip 19mm width and 0.05mm thick laying of copper strip on the floor should be at grid to 600mmx600mm throughout floor area and leaving the copper strip for connecting to existing earthing system. Applicator as specified in particular specifications.
Point wiring complete with 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including rigid steel ERW conduit (stove enamled) heavy duty as per IS 9537 Part I and all necessary flame proof, weather proof conduit accessories and fitting fixed to the surface of wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm (or nearest equivalent metric size) single core multi stranded copper conductor PVC insulated and unsheathed cable 1100 volts grade continuity wire (connecting to earth dolly) & wiring shall be suitable for frame proof area as per STEC-7 for Two light points controlled by one switch/MCB
Point wiring complete with 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including rigid steel ERW conduit (stove enamled) heavy duty as per IS 9537 Part I and all necessary flame proof, weather proof conduit accessories and fitting fixed to the surface of wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm (or nearest equivalent metric size) single core multi stranded copper conductor PVC insulated and unsheathed cable 1100 volts grade continuity wire (connecting to earth dolly) & wiring shall be suitable for frame proof area as per STEC-7 for One light points controlled by one switch/MCB
S & F LED tube light fitting. 2x20W flameproof type made of aluminium alloy, with IP65 protection complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat part No. EXTN1LT8-16/20 of Crompton Greaves or equivalent model of /Bajaj/Phillips as approved.
S & F LED tube light fitting. 2x8W flameproof type made of aluminium alloy, with IP65 protection complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat part No. EXTN2LT8-8 of Crompton Greaves or equivalent model of /Bajaj/Phillips as approved.
S&F flameproof sheet metal enclosure distribution board, TPN-4 ways, Double door, 415 V suitable for mounting MCBs.
S&F MCBs 10KA rupturing capacity class-C (ISI marked, IS-8828) of under mentioned type and rating and fixing in DBs for TPN 32/40 Amps, 415V.
S&F MCBs 10KA rupturing capacity class-C (ISI marked, IS-8828) of under mentioned type and rating and fixing in DBs for SP 6 Amps, 230V.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 250mm dia complete all as specified and directed by Engineer-in-Charge. Note :- GI pipe shall be measured and paid separetely.
Supplying, Laying, jointing, testing and commmisioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed at site for the following size for 100 mm bore Note : - Joints shall be measured and paid separetely
Supplying, Laying, jointing, testing and commmisioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed at site for the following size for 150 mm bore Note : - Joints shall be measured and paid separetely.
Material and Labour for CI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars,tail pieces,caps and plugs up to 250 mm bore confirming to IS: 1538-1993 complete all as specified and directed by Engineer - in - Charge.
Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars,tail pieces,caps and plugs up to 250 mm bore confirming to IS: 9523-2000 complete all as specified and directed by Engineer - in - Charge.
Supply, fixing, jointing & testing cast Iron Sluice Valve of 80 mm bore size , ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve and depositing to MES store yard complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
Supply, fixing, jointing & testing cast Iron Sluice Valve of 150 mm bore size , ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve and depositing to MES store yard complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 150mm dia complete all as specified and directed by Engineer-in-Charge. Note :- GI pipe shall be measured and paid separetely.
Supply, connecting up, testing and commissioning LED street light fitting, suitable for 40/45 watt LED lamp and complete with standard fittings and material and labour for provision of mounting bracket made of suitable size of bore (or higher size to suit the opening of fitting) medium grade GI pipe of 1.5 metre long along with mild steel clamps made out of FI 32 x 6 mm matching with top section of pole and connecting up with street light feeder with 3 runs of 1.50 sqmm three core PVC insulated but unsheathed , weather proof, multi stranded copper conductor cable 1100 Volts grade from street light fitting to junction box / sheet metal enclosure. Make/Model : Crompton Greaves (LSTP-45-CDL) or equivanlent in Havells/Bajaj
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal. Make Hansel Cat part No:KF 2525 G or equivalent make in /Legrand/FIBOX(SOLID PC 2528 13G).
S & F for Stay assembly complete with accessories including rod dia 16 mm of length 1.8 meter with stay strand of 7/2.24 mm size and and size of stay plate as 230 x 230 x 6mm with overall dimensions 65 x 90mm, clearance of hole 16mm including excavation and PCC in 1:3:6 type C2 to adequate depth all as directed,
Supply and Fixing of manually operated hooter of 1 Km range included with PCC foundation / stand.
Supply and Fix wall mounted digital type hygrometer with maximum temperature range showing in Deg/Celsius.
S & F Sub main wiring with 2 run of 4.0 sqmm size main cable and one run of 4.0 sqmm eart continuity conductor of single core, PVC insulated copper conductor in concealed / surface / recessed in steel conduit.
S & F Metallic conduit inclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of external dia 25mm.
S & F Rigid metallic junction boxes ( 1 to 4 way) for 25 mm external dia pipe.
Supply and laying reinforced precast concrete cable cover, class LV, type-I, flat size 250mm x 150 mm x 40 mm, abutting each other with gap between adjacent cover not exceeding 10 mm in trenches over under ground LT cable for protection.
Sood Enterprises
RAGHUSONS INFRA ENGINEERING PVT. LTD
Rahul Construction India Pvt Ltd
Akrati Technimont Limited
YAUK ENGINEERS
Triangle Engineers Pvt. Ltd.
Mata Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid