Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.3 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹8.0 L+₹50,138 (6.70%)Rejected-Finance | 2 | Rejected-Finance not lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in eligible category |
Tender Value
₹9.7 L
EMD Value
₹19,360
Closing Date
19 Oct 2021, 6:00 pmClosed
Shri Tribendra Kumar Singh AE Civ
AGE I AF Jaipur
REPAIR / REPLACEMENT OF EXTERNAL ELECTRIFICATION AND AND STEEET LIGHT AT AF STN JAIPUR
2021_MES_476839_1
8384
Open Tender
Civil Works
Item Rate
270 days
Jaipur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE I AF Jaipur
₹19,360
Yes
25 Oct 2021
22 Sept 2021
21 Oct 2021
22 Sept 2021
19 Oct 2021
6 Oct 2021
Amount
M & L for filling of new transformer oil in transformer/voltage stabilizer top up to level complete all as specified and directed. MAKE:- SAVITA/POWER/BP.
M&L for replacement of silica gel in existing breathers of transformer complete all as specified and directed.
M&L for painting of transformer/stablizer of 400/300 KVA including cleaning of exposed surface with emmery paper & brush, coat of zinc chrome red oxide primer and two coat of paint complete all as specified and directed.
Taking out/down u/s LT UG cable of any size from trenches/pipe/ducts/ pole complete all as specified and directed.
M&L for LT under ground cable 1100 V grade XLPE insulated screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductors laid in pipes, trenches/ducts fixed on pole etc complete all as specified and directed.
All as per Item Ser No.5.00 Above but having size 10 sq mm 2.0 core.
All as per Item Ser No. 5.00 Above but having size size 16 sq mm 4 core.
All as per Item Ser No. 5.00 Above but having size 25 sq mm 3.5 core.
All as per Item Ser No. 5.00 Above but having size 50 sq mm 3.5 core.
Excavation in trenches not exc 1.5 mtrs wide & not exc 1.5 mtrs in depth for taking out/laying of pipes/cables etc & getting out in soft/loose soil complete all as specified and directed .
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed .
M&L for burnt brick sub class ‘B’ size (0.230x0.115x0.075) M laid in trenches abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and directed .
M&L for sand as in sand cushioning to underground PVC cable incl punning down of sand layer all as specified complete all as specified and directed. Note : punned down thickness shall be considered for measurement & payment.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
M&L for Relaying of existing cable of any size including excavation returnig filling removal of soil repair may be carried out and fixing properly complete all as directed. (excavation ,returning filling/removal soil will be paid seperately).
M&L for Renewing cement concrete tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with grey cement and pigment complete all as specified and as directed.
M&L in replacement for 40mm bore GI tubing light grade incl. accessories for protection of cables on poles / under road crossing complete all as specified and directed.
S&F inreplacement of LED street light fitting pressure die-cast aluminium IP66 roadway luminaire with high power COB LED 45 W 5000K as light source complete all as specified and directed.
S&F in repair garden light LED fitting bollard type (Bamboo type of Havells) 10W IP 65 protection type complete with necessary electric connection and PCC foundation of suitable size as approved by AGE (I) complete all as specified and directed. (Note: PCC will be measure paid seperately as per sch item)
S&F and fixing in replacement of post top lantern light fitting LED type 15 W IP65 protection complete with necessary electric connection and groutded in PCC foundation Make : Havells or equivalent makes specified in Appendix 'B'.
S&F in replacement LED flood light 90 Watt 6000K, made up of pressure die cast housing with toughned glass and individual high power LEDs with archtectural facade, long life IP65 luminaire and electronic driver complete all as directed by Engineer-in Charge. Make :Syska/Bajaj/Crompton Greaves or equivalent makes specified in Appendix 'B'. ..
S & F of Non Integral Energy saving, environmental friendly, long life , exclusive innovative die-cast aluminium , LED flood light 350 watt symmetrically IP 66 (for high mast) lumainare with high power LED and unique flood optics to ensure uniform distribution for high mast light pole height of 20 mtr complete all as specified and as directed. Make:- Havells /Crompton Greaves/Bajaj or equivalent makes specified in Appendix 'B'. .
S&F in replacement LED aviation light red 10 watt 6000K, made up of pressure die cast housing with toughned glass and individual high power LEDs with archtectural facade, long life IP65 luminaire and electronic driver complete all as directed by Engineer-in Charge. Make : Havells/Bajaj/Crompton Greaves or equivalent makes specified in Appendix 'B'. . .
M&L for brazing of copper strip at joints and porcelain insulator fixing with 1.5 mtr distance,fixing with clamp nut bolt for building/wall arrangement complete all as specified and directed.
M&L for dismantaling old earthing and making retreatment with filling new charcoal and salt, copper sulphate (1:1:1) average 8 Kg per earth pit material and connection complete including construction new earth pit cover of existing size complete with all as specified and directed.
Repair and servicing of generators 82.5/50 KVA capacity including repairt of alternator space heater/batery charger earh fault relay,remote annuciator RTD,BTD temperature scanner, repair of AMF panel including cleaning of air filter and Overhauling and calibration of PT pump calibration of Nozzle, Spring, delivery valve, adjustment screws,barrel pump plunger etc complete all as specified and directed.
Supply only the following items for above DG set complete all as specified and directed.
(a) Oil filter
(b) Diesel filter
(c) Engine Oil
(d) Coolent
(e) fuel pipe
S&F in repair MCCB of following ratings complete all as specified and directed.
All as per Item Ser No. 34.above having 415V, 16KA, 4 Pole, 63A complete all as specified and directed.
All as per Item Ser No. 34 above but 415V, 16KA, 4 Pole, 100 A complete all as specified and directed.
All as per Item Ser No. 34 above but 415V, 26KA, 4 Pole, 125 A complete all as specified and directed.
All as per Item Ser No. 34 above but 415V, 20KA, 4 Pole, 150 A complete all as specified and directed.
All as per Item Ser No. 34 above but 4 Pole, 415 V, 160 Amps with breaking capacity 20 KA complete all as specified and directed.
All as per Item Ser No. 34 above but 4 Pole, 415 V, 200 Amps with breaking capacity 20 KA complete all as specified and directed.
All as per Item Ser No. 34 above but 4 Pole, 415 V, Adjustable type, 315Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in repair earthing strip for continuity earthing conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed.
S&F in repair Lightning arresters expulsion type/Metal Oxide(Gapless) type complete with all fittings, transmission class, discharge capacity 65 kilo Amp complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screwed.
S&F in repair battery for generator of 150 AH 12 Volts complete all as specified and directed.
S&F in repair battery for solar lights of 60 AH 12 Volts complete all as specified and directed.
S&F in repair solar street light fitting 15 watt LED type including controller complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor overall PVC sheathed 6 sq. mm , 2 core nominal cross section in service connections complete all as specified and directed. Make- Polycab/Havells.
S&F in repair smart LED spot spike colored fountain light (water proof) of capcity 10 Watt.(red/white/green coloured) complete all as specified and directed.
Repair only of existing street light fitting and replacement defective part driver of LED light Fitting of capacity 15W to 45 Watt as per site requirement including connection copper wire complete all as directed in domestic and technical area up to height 11 mtr pole and refixing street light and cable all as directed .
M&L for PCC (1:3:6) type C2 with 40 mm gradded stone aggregate for foundation of poles/stay assembly or mass filling complete all as directed.
M&L for PCC (1:2:4) type B2 with 40 mm gradded stone aggregate for copping of poles or mass filling complete all as directed.
Cutting of grass,bushes,small tree hedges,sarkanda etc and removing the same of distance not exceeding 50mtr away from the site and finishing the surface smooth by pawda etc shawel in power house and sub station building & E/M installation complete all as directed
M & L for trimming of trees falling at over head line at road area through radar area complete all as specified and directed.
M&L for MS cross arm , bracing supports , clamps and back plate fabricated from structural steel sections holding nut,bolts and washers including necessary welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclisive two coat of synethetic enamel paint over a coat of red oxide primer complete including taking down old unserviceable MS cross arm complete all as directed.
Supply, install, testing and commissioning and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, including CT coil of copper all as specified and directed. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet 75mm x 30 mm thick MS Channel frame, duly powder coated finish. Panel opening Both side double door type with aprons for cable entry shutter and locking arrangement , danger plate and earthing terminal with siutable leg. The scope of work includes provision of the following. :-Incoming (a) MCCB 315 amps 4 pole 35KA, 415V -01 No (incoming) (b Bus bar (copper strip) 450 Amp, 4 pole. (c) MCCB 4 pole 200 Amps, 25 KA, 415V (out going) -01 No, (d) MCCB 4 pole 100 Amps, 25 KA, 415V (out going) -03 No, (e) MCB TPN 40 Amp 415 V 50 HZ - 2 Nos (f) digital indication set RYB- 01 no (g) Digital volt meter - 1No (h) Digital Ampere meter - 1No
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.
M& L for replacement of LT/HT bushing of brass stud and bolt including of gasket complete set of transformer 400 KVA to match existing with proper shu down and remove cover with suitable T&P complete all as specifief and directed .
Supply and fixing in replacement MCB TPN 4 pole of capacity 63 Amp 3 phase 420 volt grade complete all as directed.
M & L for filteration of transformer oil up to break down value reached up to 50KV dielectric strength in transformer/ stabilizer of capacity up to 400 KVA / 300KVA respectively. Note: Contractor will arrange filtration plant machine at site of transformer. Dehydration work will be carried out in working condition and electric will be taken from same transformer.
Supply and jointing and testing cable end HT joint heat shrinkable type including all jointing materials suitable for indoor for 95 Sq mm 3 core cable of 11000 volts grade complete all as specified directed .
Supply and laying Insulation rubber mat for KT 11 KV supply of size 1.0X 2 mtr length complete all as specified directed
LAKSHMI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .