| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹27.0 L+₹1.9 L (7.46%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹28.1 L+₹3.0 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹28.4 L+₹3.3 L (13.2%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹28.4 L+₹3.3 L (13.2%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Mar 2020, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2020_MES_331651_1
GE/NRC/8750/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹50,000
Yes
9 Jul 2020
5 Mar 2020
23 Mar 2020
5 Mar 2020
19 Mar 2020
14 Mar 2020
Amount
Removing the fuel tank of 1000 Ltrs capacity from the DG Set of 320 KVA Capacity and cleaning the fuel tank complete including the connected inlet and out let pipes and refixing it back on the Gen Set and testing and commissioning complete.
All as per item No 1 above but 350 Ltrs from the DG Set of 250 KVA Capacity.
All as per item No 1 above but 800 Ltrs from the DG Set of 200 KVA capacity.
All as per item No 1 above but 500 Ltrs from the DG Set of 200 KVA capacity.
All as per item No 1 above but 400 Ltrs from the DG set of 125 KVA Capacity.
All as per item No 1 above but 400 Ltrs from the DG Set of 75 KVA Capacity.
All as per item No 1 above but 100 Ltrs Cleaning of fuel tank complete but for 40 KVA Capacity.
All as per item No 1 above but 150 Ltrs Cleaning of fuel tank complete but for 40 KVA Capacity. Runway-150
All as per item No 1 above but 100 Ltrs from the DG set of 30 KVA Capacity.
All as per item No 1 above but 15 Ltrs from the DG set of 10 KVA Capacity.
All as per item No 1 above but 10 Ltrs from the DG Set of 7.5 KVA Capacity.
Repair/Replacement of parts to DG set of capacity 320 KVA Model- KT-1150 G-Make- Kirloskar cummins Ltd.water cooled at Dharana pump house, and carry out the following
Radiator hose pipe & hose clips suitable for 320 KVA DG set.Make -Kirloskar AK10036 MS
Kit fuel Diesel filter and ring suitable for 320 KVA DG set. ( Make- Kirloskar cummins ) KIT3228493
Lub Oil filter suitable for 320 KVA DG set., Make- Kirkoskar KIT 3238204
Kit super bypass filter elements suitable for 320 KVA dg set ,Make Kirloskar KIT 3879488
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
Inhibitor,Corrosion suitable for 320 KVA DG set. ( Make- Kirloskar cummins ) 3167218
Inhibitor,Corrosion suitable for 320 KVA DG set. ( Make- Kirloskar cummins ) 3167217
V belt fan suitable for 320 KVA DG set 3001600
V belt fan suitable for 320 KVA DG set 178456
Air cleaner suitable for 320 KVA DG set ( Make- Kirloskar cummins ) 4055281
Diesel tank level indication pvc transparent tube suitable for 320 KVA DG set.
Replacement of coolant of the radiator-25 Ltrs.
Repair/Replacement of parts to DG set of capacity of 250 KVA DG Set, Model No GW250 (Make - Greaves Cotton) installed at Lekhanagar.
Radiator hose pipe & hose clips suitable for 250 KVA DG set.
Diesel filter suitable for 250 KVA DG set.
Oil filter suitable for 250 KVA DG set.
Engine oil recomonded by the manufacturer --
Asbestos rope of exhaust pipe of size 12 mm.
Fan belts suitable for 250 KVA DG set.
Air Elements suitable for 250 KVA DG set.
Replacement of coolant of the radiator-25 Ltrs.
Repair of hours run meter.
Repair of RPM meter.
Repair /Replacement of indication lamps.
Repair of pannel of battery charging and control pannel .
Repair/Replacement of parts to DG set of capacity 200 KVA Gen Set ( OLD) Model No-NTA 743-G at Waldevi pumping station Make- Kirloskar cummins Ltd.water cooled and carry out the following
Radiator hose pipe & hose clips suitable for 200 KVA Gen Set Model No-NTA 743-G at Waldevi pumping station.Make -Kirloskar
Kit fuel Diesel filter and ring suitable for 200 KVA Gen Set Model No-NTA 743-G ( Make- Kirloskar cummins )
Lub Oil filter suitable for 200 KVA Gen Set Model No-NTA 743-G , Make- Kirkoskar
Kit super bypass filter elements suitable for 200 KVA Gen Set Model No-NTA 743-G ,Make Kirloskar
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
Inhibitor,Corrosion suitable for200 KVA Gen Set Model No-NTA 743-G . ( Make- Kirloskar cummins )
Inhibitor,Corrosion suitable for 200 KVA Gen Set Model No-NTA 743-G . ( Make- Kirloskar cummins )
V belt fan suitable for 200 KVA Gen Set Model No-NTA 743-G
V belt fan suitable for 200 KVA Gen Set Model No-NTA 743-G.
Air cleaner suitable for 200 KVA DG set ( Make- Kirloskar cummins )
Diesel tank level indication pvc transparent tube suitable for 200 KVA DG set.
Replacement of coolant of the radiator-25 Ltrs.
Repair/Replacement of parts to DG set of capacity 200 KVA Gen Set ( NEW) Model No-NTA 743-G at Waldevi pumping station Make- Kirloskar cummins Ltd.water cooled and carry out the following
Radiator hose pipe & hose clips suitable for 200 KVA Gen Set Model No-NTA 743-G at Waldevi pumping station.Make -Kirloskar
Kit fuel Diesel filter and ring suitable for 200 KVA Gen Set Model No-NTA 743-G ( Make- Kirloskar cummins )
Lub Oil filter suitable for 200 KVA Gen Set Model No-NTA 743-G , Make- Kirkoskar
Kit super bypass filter elements suitable for 200 KVA Gen Set Model No-NTA 743-G ,Make Kirloskar
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
Inhibitor,Corrosion suitable for200 KVA Gen Set Model No-NTA 743-G . ( Make- Kirloskar cummins )
Inhibitor,Corrosion suitable for 200 KVA Gen Set Model No-NTA 743-G . ( Make- Kirloskar cummins )
V belt fan suitable for 200 KVA Gen Set Model No-NTA 743-G
V belt fan suitable for 200 KVA Gen Set Model No-NTA 743-G.
Air cleaner suitable for 200 KVA DG set ( Make- Kirloskar cummins )
Diesel tank level indication pvc transparent tube suitable for 200 KVA DG set.
Replacement of coolant of the radiator-25 Ltrs.
Repair/Replacement of parts to DG set of capacity 125 KVA DG Set, Model No 6R1080TA (Make - Kirloskar Green) installed at AC Plant, NRC and carry out the following
Kit fuel Diesel filter and ring suitable for 125 KVA DG Set, Model No 6R1080TA (Make - Kirloskar Green)
Lub Oil filter suitable for 125 KVA DG Set, Model No 6R1080TA (Make - Kirloskar Green)
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
V belt fan suitable for 125 KVA DG Set, Model No 6R1080TA (Make - Kirloskar Green)
Air cleaner suitable for125 KVA DG Set, Model No 6R1080TA (Make - Kirloskar Green)
Diesel tank level indication pvc transparent tube suitable for 125 KVA DG Set, Model No 6R1080TA (Make - Kirloskar Green)
Replacement of coolant of the radiator-25 Ltrs.
Repair of hours run meter.
Repair of RPM meter.
Repair of indication lamps.
Repair/Replacement of parts to DG set of capacity 75 KVA DG Set, Model No 4R1040TA (Make - Kirloskar Green) installed at AC Plant, NRC.and carry out the following
Kit fuel Diesel filter and ring suitable for 75 KVA DG Set, Model No 4R1040TA (Make - Kirloskar Green)
Lub Oil filter suitable for 75 KVA DG Set, Model No 4R1040TA (Make - Kirloskar Green)
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
V belt fan suitable for 75 KVA DG Set, Model No 4R1040TA (Make - Kirloskar Green)
Air cleaner suitable for75 KVA DG Set, Model No 4R1040TA (Make - Kirloskar Green)
Diesel tank level indication pvc transparent tube suitable for 75 KVA DG Set, Model No 4R1040TA (Make - Kirloskar Green)
Replacement of coolant of the radiator-25 Ltrs.
Repair of hours run meter.
Repair of RPM meter.
Repair of indication lamps.
Repair/Servicing and overhauling of diesel engine driving generating set 40 KVA, Type 4R1040G, Make-Kirloskar at Runway in AOP area. Checking throughly the Generator and finding out its faulty/defective parts and complete servicing and refixing complete spares of the DG set including replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after satisfactory repair to the entire satisfaction of Engr-in-charge.
Radiator hose pipe & hose clips suitable for 40 KVA DG set.
Diesel filter suitable for 40 KVA DG set. ( Make- Kirloskar )
Oil filter suitable for 40 KVA DG set., Make- Kirkoskar
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
Fan belts suitable for 40 KVA DG set.
Air Elements suitable for 40 KVA DG set.
Diesel tank level indication pvc transparent tube suitable for 40 KVA DG set.
Hose pipe of all return Diesel lines suitable for 40 KVA DG set.
Oil pressure gauge suitable for 40 KVA DG set.
Water tempreture gauge suitable for 40 KVA DG set.
Battery charging indicating meter.suitable for 40 KVA DG set.
Ignition switch of the panel board. suitable for 40 KVA DG set.
O' ring suitable for 40 KVA DG set.
Piston ring suitable for 40 KVA DG set.
CR bearing suitable for 40 KVA DG set.
CR bush suitable for 40 KVA DG set.
Valve pair suitable for 40 KVA DG set.
Valve guide suitable for 40 KVA DG set.
Head gasket suitable for 40 KVA DG set.
Replacement of coolant of the radiator-4 Ltrs.
Repair/Servicing and overhauling of diesel engine driving generating set 40 KVA, Type RB-44, Make-Kirloskar at BASE SERVICES in AOP area. Checking throughly the Generator and finding out its faulty/defective parts and complete servicing and refixing complete spares of the DG set including replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after satisfactory repair to the entire satisfaction of Engr-in-charge.
Radiator hose pipe & hose clips suitable for 40 KVA DG set.
Diesel filter suitable for 40 KVA DG set. ( Make- Kirloskar )
Oil filter suitable for 40 KVA DG set., Make- Kirkoskar
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
Fan belts suitable for 40 KVA DG set.
Air Elements suitable for 40 KVA DG set.
Diesel tank level indication pvc transparent tube suitable for 40 KVA DG set.
Hose pipe of all return Diesel lines suitable for 40 KVA DG set.
Oil pressure gauge suitable for 40 KVA DG set.
Water tempreture gauge suitable for 40 KVA DG set.
Battery charging indicating meter.suitable for 40 KVA DG set.
Ignition switch of the panel board. suitable for 40 KVA DG set.
Replacement of coolant of the radiator-4 Ltrs.
Repair/Servicing and overhauling of diesel engine driving generating set 40 KVA, Type RB-44, Make-Kirloskar at ATC in AOP area. Checking throughly the Generator and finding out its faulty/defective parts and complete servicing and refixing complete spares of the DG set including replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after satisfactory repair to the entire satisfaction of Engr-in-charge.
Radiator hose pipe & hose clips suitable for 40 KVA DG set.
Diesel filter suitable for 40 KVA DG set. ( Make- Kirloskar )
Oil filter suitable for 40 KVA DG set., Make- Kirkoskar
Engine oil recomonded by the manufacturer -- (Power Supreme 15w40)
Asbestos rope of exhaust pipe of size 12 mm.
Fan belts suitable for 40 KVA DG set.
Air Elements suitable for 40 KVA DG set.
Diesel tank level indication pvc transparent tube suitable for 40 KVA DG set.
Hose pipe of all return Diesel lines suitable for 40 KVA DG set.
Oil pressure gauge suitable for 40 KVA DG set.
Water tempreture gauge suitable for 40 KVA DG set.
Battery charging indicating meter.suitable for 40 KVA DG set.
Ignition switch of the panel board. suitable for 40 KVA DG set.
Replacement of coolant of the radiator-4 Ltrs.
Repair/replacement of the following spares as given below for 30 KVA DG Set, Model No S3-862 (Make-Cummins) installed at Record office Arty NRC.
Diesel filter (pre and micro)
Oil filter
Electrical coil with plunger
V belt for fan
All flexible Hose of fuel
Air elements
Return pipe of diesel
Flexible pipe filter to pump
Engine oil recommended by the manufacturer -- (Power Supreme 15w40)
Replacement of coolant of the radiator
Repair to electronics RPM, water temp,oil peressure,oil temp meters in pannel
Repair/replacement of the following spares as given below for 30 KVA DG Set, Model No RB-33 (Make-Kirloskar Green) installed at Record office Arty NRC.
Diesel filter (pre and micro)
Oil filter
V belt for fan
All flexible Hose of fuel
Air elements
Return pipe of diesel
Flexible pipe filter to pump
Engine oil recommended by the manufacturer -- (Power Supreme 15w40)
Replacement of coolant of the radiator
Repair to electronics RPM, water temp,oil peressure,oil temp meters in pannel
Repair/Replacement of the following spares as given below for 7.5 KVA DG Set, Make-Kirloskar, installed at Telephone Exchange Arty Centre NRC.
Diesel filter .
Oil strainer .
Engine oil recommended by the manufacturer -- (Power Supreme 15w40)
Supply and fix sealed maintenance free GENSET starting Unit pure lead power pack (X Cell) Model No XCL 12 V 3200, 12 volt suitable for 30 kva to 75 kva DG set
Supply and fix sealed maintenance free GENSET starting Unit pure lead power pack (X Cell) Model No XCL 24 V 3200, 24 volt suitable for 125 kva to 300 kva DG set
Cleaning of DG Set complete and scrapping the old paint of DG Set body along with fuel tank, panel board and connected assessories and painting the same over a coat of red oxide ( Note- colour of paint will be approved by Engg In Charge) and numbering on Gen Set on both Engine and Altrenator all as per directed by Engg In Charge of capacity 40 KVA at AOP area.
Cleaning of DG Set complete and scrapping the old paint of DG Set body along with fuel tank, panel board and connected assessories and painting the same over a coat of red oxide ( Note- colour of paint will be approved by Engg In Charge) and numbering on Gen Set on both Engine and Altrenator all as per directed by Engg In Charge of capacity 7.5 KVA
Taking out alternator assembly from prime mover of 200 KVA Gen Set Model No-NTA 743-G at Waldevi pumping station by unscrewing, foundation & coupler bolts/nuts and transportation to workshop for necessary repair, maintenance as indicated below :- (a) Dismantling of complete alternator assembly, taking out excitor unit, rectifier, armature assembly including shaft, bearing, slip ring etc and keeping aside for further repair/maintenance. (b) Removing of dust, carbon from field coils, armature, excitor unit by means of blowing forced air using blower and cleaning of all components using carbon tetra chlorine all as directed and segregation of unserviceable and serviceable spares/components for necessary replacement and re-use respectively. (c) Varnishing of armature, excitor unit, field coil assembly using Ist quality doctor beak insulation varnish and retain in heat chamber for 48 hours for complete drying including replacement of vertex paper in place of worn out one in excitor unit all as required. (d) Turning of slipring in lathe for making the same smooth and for continuous operation and to ensure firm and smooth contact and running with carbon brush. (e) Assembling of complete alternator assembly including replacement of following spares and components including requisite lubrication with grease in all moving parts like bearing. (f) Bearing for prime mover end (DE) - 01 No.
All as per Item No.28.00 :- (g) dead end (NDE) - 01 No. (h) Carbon brush holder (set of 4) - 01 Set (j) Carbon brush set of 08 - 01 Set (k) Rectifier Assembly - 01 Set (l) Transformer coils -03 Nos (m) Connector assembly for excitor unit - 01 No. (n) Carrying insulation test of field coil to body, armature to body and achieve the healthy insulation level. (o) Transportation repaired and assembled alternator and coupling with prime mover including bolting with foundation from and realignment with prime mover complete to the entire satisfaction of Engr-in-charge and commissioning and driving with full load all as directed.
Taking out alternator assembly from prime mover of 40 KVA Gen Set Model No -RB-44 at Runway, AOP by unscrewing, foundation & coupler bolts/nuts and transportation to workshop for necessary repair, maintenance as indicated below :- (a) Dismantling of complete alternator assembly, taking out excitor unit, rectifier, armature assembly including shaft, bearing, slip ring etc and keeping aside for further repair/maintenance. (b) Removing of dust, carbon from field coils, armature, excitor unit by means of blowing forced air using blower and cleaning of all components using carbon tetra chlorine all as directed and segregation of unserviceable and serviceable spares/components for necessary replacement and re-use respectively. (c) Varnishing of armature, exitor unit, field coil assembly using Ist quality doctor beak insulation varnish and retain in heat chamber for 48 hours for complete drying including replacement of vertex paper in place of worn out one in exitor unit all as required. (d) Turning of slipring in lathe for making the same smooth and for contineous operation and to ensure firm and smooth contact and running with carbon brush. (e) Assembling of complete alternator assembly including replacement of following spares and components including requisite lubrication with grease in all moving parts like bearing. (f) Bearing for prime mover end (DE) - 01 No.
All as per Item No. 29.00 (g) dead end (NDE) - 01 No. (h) Carbon brush holder (set of 4) - 01 Set (j) Carbon brush set of 08 - 01 Set (k) Carrying insulation test of field coil to body, armature to body and achieve the healthy insulation level. (l) Transportation repaired and assembled alternator and coupling with prime mover including bolting with foundation from and realignment with prime mover complete to the entire satisfaction of Engr-in-charge and commissioning and driving with full load all as directed.
S & F On load Changeover switch in sheet steel enclousers of capacity 63 Amp , 4 pole .Make:- L&T/Scheinder/ABB
S & F On load Changeover switch in sheet steel enclousers of capacity 100 Amp , 4 pole .Make:- L&T/Scheinder/ABB
S & F On load Changeover switch in sheet steel enclousers of capacity 160 Amp , 4 pole .Make:- L&T/Scheinder/ABB
S & F On load Changeover switch in sheet steel enclousers of capacity 200 Amp , 4 pole .Make:- L&T/Scheinder/ABB
Supply , Install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board,including taking down old u/s panel , cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber.D10 The panel shall be dust and vermin proof IP-54 class protection and made out of 3.00 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 30 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size cable lugs cable gland and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- Note- 1) internal sufficient space for accomodate following items (a) ACB 800 Amps (b) Changeover switch 800 Amps (c) MCCB 400 amps ,(d) Voltmeter (e) Ammeter (f) RYB Set (g) bus bar tpn 1000 amps (h) ct 800x5 (2) The items (a) to( h) will be measured & paid separately under relevant items of schedule 2) Rate is inclusive of removing old cable & fixing in new panel with new lugs / glands as required.
S&F MCCB 4 pole, 630 Amps ,50ka ,thermal magnetic relese, Ics=100% Icu & L& T CAT No CM94104OOT1OG / Legrand / Scheinder
S&F MCCB 4 pole, 250 Amps ,50ka ,thermal magnetic relese, Ics=100% Icu & L&T Cat No- CM92106OOP1OG / Legrand / Schneider
S&F AMMETER L&T Cat No WL131020OOOO
S&F Voltmeter digital type 0-500V L &T Cat No WL132020OOOO
S&F LED Indicator lamp with fuse RYB - 01 Set
S&F Busbar copper TPN 1000 amp - 01 Set
S&F CT 800 x 5
S & F onload change over switch 800A ,4 pole with advance neutral , open execution type, Make:- Havelles cat no IHCNFOO800 / ABB/Scheinder
M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m with GI protection pipe 50mm dia, GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement,complete all as shown on electrical plate no.3 of SSR Part I (2009) and testing on completion.
NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 14,900.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
SHRI SULAI ELECTRICALS
M/s Anil Builders
devang Electricals
UNITED ENTERPRISES
Mayur Electro Enterprises
P C DAVE AND SONS
M/S MK Nair
Bidder Name
SHRI SULAI ELECTRICALS
P C DAVE AND SONS
DURGAI ELECTRICALS
UNITED ENTERPRISES
M/S MK Nair
M/s Anil Builders
Mayur Electro Enterprises
devang Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .