| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.5 L+₹1.4 L (8.40%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L2 | Rejected-Finance L2 |
Tender Value
₹17.4 L
EMD Value
₹34,720
Closing Date
26 Sept 2022, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
COMPREHENSIVE REPAIR MAIN TO MECHANICAL LAUNDRY AND OIL FIRED INCINERATOR AT MH UNDER GE (EAST) JALANDHAR CANTT
2022_MES_526358_3
GE/JULL/ET-15/2022-23
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹34,720
Yes
22 Nov 2022
5 Sept 2022
4 Oct 2022
5 Sept 2022
26 Sept 2022
14 Sept 2022
Amount
AMC of laundry equipments installed at Military Hospital JRC including repair/ replacement of major and minor spare parts of the washer extractor sluicing machine 30 Kg, required during AMC without any extra cost of Govt by the manufacturer/ authorised agent of the Laundry Plant all as specified and directed Notes for srl item No. 1.00 to 10.00 : Contractor shall keep the following aspects in mind while quoting unit rates and rates quoted shall be deemed to be involving the following :- (a) All defective parts will be replaced by contractor within 48 Hrs for above mentioned Laundry Plants. Replacement cost of defective parts is to be included in above mentioned AMC Rates otherwise a penalty of Rs. 500 per day will be imposed on contractor. (b) In order to certify proper maint of the plant, monthly & breakdown visits of Engineer/ Technician from OEM/ approved firm to check efficient running of Laundry Plant is mandatory on part of contractor. The unit rates quoted by the tenderer shall be deemed to be included this aspect. Necessary documents in support of visit of authorised representatives from OEM/ approved firm shall be submitted by the contractor after each visit. On failure of visit by OEM/ approved firm representative or non-submission of report by him, a panel recovery of Rs. 15000/- per visit shall be made from the contractor due.
(c) Contractor shall enter into an agreement with OEM/ approved firm company for AMC and submit to GE (E) JRC after acceptance of work within 15 days. (d) AMC includes monthly visit of qualified and experienced technician/ Engineer and Inspection, dismantling and taking down the needful items in connection to carry out necessary repair/ maintenance of all machines of Laundry Plant and replacement of spares and complete assembling after repair/ overhauling, servicing, cleaning and testing so as to make the machine functional in all aspects. (e) Cleaning of chocked steam pipe lines and steam trap valves and welding and replacement of coupling, joints, union etc if required to stop leakage of water and steam from the pipe lines. (f) Except srl item No. 12.00 to 48.00 - All major/ minor spare parts required during AMC shall deemed to be included in the quoted rate. (g) The cost of transportation if any required is deemed to be included in the quoted rate. (h) Contractor must have to ensure the MES & MH rep for the machine functional in all aspects.
All as per srl item No. 1.00 here-in-before but washing machine 100 Kg
All as per srl item No. 1.00 here-in-before but washing machine 50/60 Kg
All as per srl item No. 1.00 here-in-before but hydro extractor 25 Kg
All as per srl item No. 1.00 here-in-before but drying tumbler of capacity 50 Kg
All as per srl item No. 1.00 here-in-before but drying tumbler of capacity 60 Kg
All as per srl item No. 1.00 here-in-before but flat work Ironer double roller type
All as per srl item No. 1.00 here-in-before but flat bed press 1500 x 750mm
All as per srl item No. 1.00 here-in-before but air compressor of capacity 5 HP
All as per srl item No. 1.00 here-in-before but water softening plant Note : Water sample will be collected from inlet and oulet of the plant and tested from NABL accredited laboratory as and when directed by Engineer-in-Charge without any extra cost.
AMC of steam boiler 350000 kcal/ hr installed at Military Hospital JRC including repair/ replacement of major and minor spare parts required during AMC without any extra cost of Govt by the OEM of the Laundry Plant. The comprehensive maintenance services package covers the following :- (a) Site visit for preventive maint and check-up of steam boiler will be carried out by service technician of manufacturer or as recommended by the OEM every month during the contract period. In the visit, technician will check and inspect of both steam boiler plant system complete of capacity 600 Kg/ Hr Make : Fabtech Engineering. (b) Contractor must submit the service reports every month from the service engineers alongwith the details of the repair/ maint/ replacement of spares/ testing of steam boilers carried out during every month during the contract period. ON failure of visit by OEM/ approved firm representative or non submission of report by him, a penal recovery of Rs. 10000/- per visit shall be made from the contractor due. (c) Cleaning of chocked coil by descaling steam boiler-02 Nos, if required engineer shall be supervising the descaling activity with descaling chemical (i.e. chemical recommended by OEM). (d) Servicing/ repair of all water pumps including replacement of unserviceable seals and glands, and servicing, greasing/ alignment of shaft/ testing complete of all motors of both steam boilers. (e) Servicing/ repair/ testing of electric control panel and replacement of unserviceable minor spares like meter, wiring etc complete of both steam boilers. (f) Contractor must have to ensure the MES & MH rep for the machine functional in all aspects (g) All spare parts required during AMC period shall be deemed to be included in the quoted rate except Srl item No. 12.00 to 48.00
Supply and fixing in replacement burner Nozzle suitable for the steam boiler 600 Kg complete all as specified and directed. Make: Thermax/ Fabtech.
Supply and fixing in replacement burner gun suitable for the steam boiler 600 Kg complete all as specified and directed. Make: Thermax/ Fabtech.
Supply and fixing in replacement pressure switch for water suitable for the steam boiler 600 Kg complete all as specified and directed. Make: Indfoss Model 520-400 or equivalent in GURU/Thermax/ Donfoss
Supply and fixing in replacement pressure guage 0-21 Kg/ sqcm suitable for the steam boiler 600 Kg complete all as specified and directed. Make: Indfoss Model 520-400 or equivalent in GURU/Thermax/ Donfoss
Supply and fixing crystal salt as per sample for water softner plant to reduce the hardness of water complete all as specified and directed
Supply and fixing PH booster for the water softner plant complete all as specified and directed Make : Fabtech/ Thermax/ Maxtreat
Material and labour for insulation of MS pipe with PUF slab 30mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet complete of 50mm dia all as specified and directed
All as per srl item No. 18.00 here-in-before but 40mm dia
All as per srl item No. 18.00 here-in-before but 25mm dia
All as per srl item No. 18.00 here-in-before but 20mm dia
Supply and laying MS pipe 50mm bore, heavy grade with all fittings fixed to wall, ceilings and or laid in floors etc. complete all as specified and directed.
All as per srl item No. 22.00 here-in-before but 40mm dia
All as per srl item No. 22.00 here-in-before but 25mm dia
All as per srl item No. 22.00 here-in-before but 20mm dia
Supply and fixing in replacement brass steam stop valve 15 mm Bore for steam with wheel head complete all as specified and directed. Make: Sant/Scud/leader
Supply and fixing in replacement brass steam stop valve 25 mm Bore for steam with wheel head complete all as specified and directed. Make: Sant/Scud/leader
Supply and fixing in replacement brass steam stop valve 50 mm Bore for steam with wheel head complete all as specified and directed. Make: Sant/Scud/leader
Supply, laying, testing and commissioning in replacement of LT cable insulated PVC sheathed, unarmoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor size 16 Sqmm 4 Core all as specified and directed
Material and labour for preparation of surface for painting of steam boiler (Model FE/BLR/CO of Febtech Engineering) all accessories, connected items i.e Boilers outer shell, moisture separator, economiser, Chimney, Flue gas duct, main header for flue gas, other MS/Aluminium structure, MS pipes for fuel and water , other E/M eqpts etc by preparation of surface by scraping old paint with sand paper and blower, filling of cavities with suitable putty and applying two coat of super enamel synthetic heat resistance paint, with hold upto temperature 20000 0C properly paint over one coat of red oxide paint with same specification complete all as specified and directed
Material and labour for painting of MS surface of Chimney of steam boilers and incinerator, surface of iincinerator chambers, and other surface of incinerator parts by preparation of surface by scraping old paint with sand paper and blower, filling of cavities with suitable putty and applying two coat of super enamel synthetic heat resistance paint, with hold upto temperature 20000 C properly paint over one coat of red oxide paint with same specification complete all as specified and directed
Material and labour for cross arms cable tray Angle iron / MS hollow pipes (round or square) bracings, supports, clamps and back plates fabricated from structural steel sections including nuts and bolts, washers, selding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive or one primer coat, and one under coat and one finishing coat of paint. all as specified and directed
Material and labour for rewinding of electric motor 1HP 3 phase 440 V AC 1400RPM including the following jobs:- (a) Rewinding of electric motor of washing Calendaring machine/flat bed press etc. Using super enameled copper winding wire of existing gauge, replacement of insulating material, sleeves and varnishing the same after rewinding. (b) Cleaning washing ball bearing with kerosene Oil, greasing and filled fresh grease of existing grade Make : Castrol, refixing to its original position and testing commissioning complete all as specified.
All as per item No 33.00 here-in-before but for electric motor of capacity 2 HP, 3 Phase 440 V
All as per item No 33.00 here-in-before but for electric motor of capacity 3 HP, 3 Phase 440 V
All as per item No 33.00 here-in-before but for electric motor of capacity 5 HP, 3 Phase 440 V
All as per item No 33.00 here-in-before but for electric motor of capacity 7.5 HP, 3 Phase 440 V
All as per item No 33.00 here-in-before but for electric motor of capacity 10 HP, 3 Phase 440 V
Supply and fixing in replacement Finnel strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Drying tumbler complete all as specified and directed. Make: Daspass/Lazer/Usha
Supply and fixing in replacement trolley wheel suitable for wash Room trolley/dry, linen trolley size 6” dia as per sample complete all as specified. Make : Senson/Satyam/Rolin
Supply and fixing in replacement DOL starter in sheet steel enclosure, AC 415 volts 50 C/S 3 phase with single phasing protection of capacity 5 HP complete all as specified and directed. Make : L&T/Siemens/GE/BCH
Supply and fixing in repair sealed maintenance free battery 12V, 65 AH suitable for online UPS complete all as specified and directed Make : Exide/ Amaron/ Standard/ Luminous
Supply and fixing in replacement LED flood lights 150 watts from building/ pole/ highmast, IP-66, high power LED flood light with pressure die-cast aluminium housing complete with all accessories driver, SPD all as specified and directed. Notes: (i) All LED fitting shall be made in India only. (ii) Contractor shall be provided 2 years written manufacturer’s warranty for the LED fixture complete including driver from the certified date of completion. (iii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer's local office and certificate of IP-66 and IK-08 from manufacturer.
Supply and fixing in replacement LED aviation obstruction light luminaire comprising aluminium housing and polycarbonate enclosure complete in laundry boiler chimney with all accessories and electric connection from aviation light to DB box with PVC FRLS stranded copper wire 2.5 sqmm three run including PVC conduit and fixing material all as specified and directed
Supply and fixing in replacement in existing LT panel MCCB 3 pole, fixed type, 63 Amps of breaking capacity 16 KA complete all as specified and directed
Supply and fixing in replacement in existing LT panel MCCB 4 pole, fixed type, 100 Amps of breaking capacity 16 KA complete all as specified and directed
Supply and fixing in replacement in existing LT panel MCB TP, 6-32 Amps, C curve, 415V, 10 KA complete all as specified and directed
Supply and fixing in replacement in existing LT panel MCB FP, 63 Amps, C curve, 415V, 10 KA complete all as specified and directed
Material and labour for servicing of online UPS 15 KVA 3 phase in 3 phase out of model 9 LLTEM of Microtek by engineer of Microtek company on monthly basis by cleaning dust from all electronic parts with blower and cleaning brush checking serviceability of all electronic parts including IGBT's SCR diode, HBC fuses, Capacitors, charger card, IP sense TX PCB, O/P sense TX PCB, protection card, SMPS card, driver card, LED display module, DC capacitors, AC fans, CD MCB's wiring, copper strips and replace if any part found defective, cleaning and greasin battary terminals of 30 Nos batteries all as specified and directed. Note:- (i) Successful bidder will have to submit AMC from OEM i.e. Microtek within one week of acceptance of contract. (ii) AMC will cover complete repair/replacement of parts of UPS.
Material and labour for servicing of shadow less OT light dual type 2 dome four Nos complete all as specified and directed. Note:- (i) Successful bidder will have to submit AMC from OEM within one week of acceptance of contract. (ii) AMC will cover complete repair/replacement of US parts of lights.
Material and labour for servicing of online UPS 3 KVA single phase 4 Nos of Microtek by engineer of Microtek company on monthly basis by cleaning dust from all electronic parts with blower and cleaning brush checking serviceability of all electronic parts including IGBT's SCR diode, HBC fuses, Capacitors, charger card, IP sense TX PCB, O/P sense TX PCB, protection card, SMPS card, driver card, LED display module, DC capacitors, AC fans, CD MCB's wiring, copper strips and replace if any part found defective, cleaning and greasing battery terminals of 6 Nos batteries all as specified and directed. Note:- (i) Successful bidder will have to submit AMC from OEM i.e. Microtek within one week of acceptance of contract. (ii) AMC will cover complete repair/replacement of unserviceable parts of UPS including batteries.
TARA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .