| 1 | 1₹16.7 LAccepted-AOC | 1 | Accepted-AOC Lowest accepted bidder | |
| 2 | 2₹17.1 L+₹20,035.50 (1.19%)Rejected-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | 2 | Rejected-AOC Lowest accepted bidder is M/S ACESOLARR RENEWABLE ENERGY LLP | |
| 3 | 3₹17.6 L+₹76,506 (4.54%)Rejected-AOC | 3 | Rejected-AOC Lowest accepted bidder is M/S ACESOLARR RENEWABLE ENERGY LLP | |
| 4 | 4₹18.0 L+₹1.1 L (6.67%)Rejected-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | 4 | Rejected-AOC Lowest accepted bidder is M/S ACESOLARR RENEWABLE ENERGY LLP | |
| 5 | 5₹18.2 L+₹1.4 L (8.10%)Rejected-AOC RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | 5 | Rejected-AOC Lowest accepted bidder is M/S ACESOLARR RENEWABLE ENERGY LLP |
Tender Value
₹20.8 L
EMD Value
₹41,600
Closing Date
2 Aug 2021, 6:00 pmClosed
CWE Bikaner
HQ CWE Bikaner Military Station Bikaner
Special repair / replacement of 180 KVA DG Set at KLP Filtration Plant at Suratgarh Mil Stn
2021_MES_457182_1
CWE BKN TOKEN NO 20 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Suratgarh
Contractor shall be enlisted with MES in Class E and above and category b(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in WLR .Contractor not enlisted with MES should meet the enlistment criteria of E
7 documents required · 7 mandatory
₹500
GE (A) Suratgarh
₹41,600
Yes
22 Sept 2021
5 Jul 2021
4 Aug 2021
5 Jul 2021
2 Aug 2021
21 Jul 2021
5 Jul 2021 - 15 Jul 2021
Amount
Disconnecting and taking down carefully existing unserviceable DG Set of capacity 180 KVA with all accessories and depositing the same to store yard of AGE E/M (A) Suratgarh complete all as directed.
Supply, installation, commissioning and testing of Silent (acoustic encloser type) Diesel Engine driven Generating Set of capacity 180 KVA, outdoor type, 415 Volt, 3 Phase, 4 wire, 1500 RPM as per IS : 10001/ 10002 and brushless Alternator as per IS : 13364 (Part-1) complete, electronic type governor, Class A1, Power Factor 0.8 (minimum), with standard control panel with necessary meters, Battery 65 Ah maintenance free IS : 14257 for high cranking performance – 02 Nos, sound proof canopy as per CPCB norms, directly coupled complete with self starting system including accessories, equipment control panel etc as per BS/IS-5514/10002, including foundation as per OEM recommendations, with and including all components/accessories mentioned in Particular Specifications Section-II, complete all as specified and as directed.
M&L for Earthing complete with & including Copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m deep below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including Copper strip 20x3 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to DG Set / transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing of any type. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 300 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and as directed. Note :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance exc 250m but not exc 500m and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :- (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
S&F On Load change over switch in sheet steel enclosure with front handle, 630 Amps, 4 Pole, 415 Volts, 50 Hz, fixed in repairs, complete all as specified & as directed.
Vijaypower Generators Limited
AJAY ELECTRIC COMPANY
M/s Rohit Construction Co.
SRI SAI CONSTRUCTION COMPANY
Swastika Engineers and Agencies
MONA GENERATOR SEVICES PVT. LTD.
J and K constructions company
Gupta Suppliers
GURDEEP SINGH AND COMPANY
PACHAR BROTHERS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .