Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹8.3 Cr |
Tender Value
₹9.3 Cr
EMD Value
₹18.6 L
Closing Date
14 May 2026, 5:00 pmClosed
Gopal Prasad Singh
EE PDA
1ST FLOOR, UDYOG BHAWAN EAST GANDHI MAIDAN PATNA 800004
Gopal Prasad Singh
EE PDA
(Re-Tender) Construction of Khadi Mall on the land of Bihar State Khadi Village Industries Board in Munger.
130314
NIT 10/TEN/IDA/26
Open Tender
CIVIL
Patna
• REGISTRATION
Class
• ELECTRICAL LICENCE REGISTRATION
• "LEGAL STATUS OF BIDDER
ITB clause 4.3 (a)
• PERMANENT ACCOUNT NUMBER (PAN)
• GST REGISTRATION
• "COST OF BOQ
(e payment only)"
• EARNEST MONEY DEPOSIT (BID SECURITY)
Earnest Money Deposit (Bid Security) will be accepted only in online mode (Internet Payment Gateway). No other forms of Earnest Money Deposit (Bid Security) will be accepted.
• WORK EXPERIENCE OF SIMILAR NATURE ( Building Work)
Section 1 ITB 4.5 (A) (b) of SBD
• QUANTITY WISE EXPERIENCE
Section 1 ITB 4.5 (A) ( c ) of SBD
MINIMUM QUANTITY / AMOUNT AS PRESCRIBED IN SBD
RCC+PCC : 752.89 Cum
Brick Work : 224.51 Cum
Earth Work+Local Sand : 352.1 Cum
Pile Work(300mm dia or above): 498.75 rm
Furniture : Rs. 33,29,919.00
Electrical Work +HVAC Work : Rs. 71,39,019.00
PHE Work : Rs 14,75,202.00
Lift Work : Rs 21,24,000.00
Fire-Fighting Work : Rs 3,47,993.00
• "ANNUAL FINANCIAL TURN OVER OF LAST FIVE YEARS
ITB clause 4.5 (A)(a)
(Balance Sheet, Profit & Loss And Audit Report duly audited by CA)"
"FY 2020-2021 Amount To be entered (Rs in Lakhs)"
"FY 2021-2022 Amount To be entered (Rs in Lakhs)"
"FY 2022-2023 Amount To be entered (Rs in Lakhs)"
"FY 2023-2024 Amount To be entered (Rs in Lakhs)"
"FY 2024-2025 Amount To be entered (Rs in Lakhs)"
• BANKER'S CERTIFICATE EVIDENCE OF ACCESS TO OR
AVAILABILITY OF CREDIT FACILITIES (10% OF PROJECT COST)
Section 1 ITB 4.2 ( i ) of S.B.D
• "BIDDING CAPACITY (BC=A*N*3-B)
Section 1 ITB 4.7 of S.B.D"
• (A) AMOUNT OF EXISTING COMMITMENTS AND ONGOING WORKS
• (B) AMOUNT OF WORK FOR WHICH BID ALREADY SUBMITTED
• "BANKERS' CERTIFICATE FOR EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT FACILITIES
• "AFFIDAVIT
• CHARACTER CERTIFICATE
• UNDERTAKING
(i) Investment of minimum cash up to 25% of the value of the work during implementation of the contract.
Section 1 ITB 4.2 (ii) of SBD
• (ii) Bid Validity : 120 days
Section 1 ITB 15.1 of SBD
• LITIGATION HISTORY
Section 1 ITB 4.3 ( j ) of SBD"
• "PROPOSED METHODOLOGY AND PROGRAMME OF CONSTRUCTION
Section 1 ITB 4.3 ( l ) of S.B.D"
• TECHNICAL PERSONNEL
Section 1 ITB Clause 4.5 B (b)"
• LIST OF KEY PLANTS & EQUIPMENTS
Section 1 ITB 4.5 B (a)"
• "JOINT VENTURE
(Bids From Joint Ventures Are Acceptable Only Above Rs. 10.00 Crores Project)
CIVIL
ITEM RATE
L1
1
24 documents required · 24 mandatory
₹11,800
Processing Fee: 5900
₹18.6 L
IDA, 1st Floor, Udyog Bhawan, East Gandhi Maidan, Patna 800004
29 Jul 2026
30 Apr 2026
15 May 2026
30 Apr 2026
14 May 2026
30 Apr 2026
5 May 2026
INFRASTURUCTURE DEVELOPMENT AUTHORITY First Floor, Udyog Bhawan, East of Gandhi Maidan, Patna
TECHNICAL BID SHEET
TENDER NUMBER 10/TEN/IDA/26 DATE OF ISSUE OF TENDER 15.04.2026
NAME OF WORK (Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण COST OF WORK AS PER BOQ Rs. 93,009,419.00
BID SECURITY (EARNEST MONEY DEPOSIT) AMOUNT Rs. 1,860,500.00 COMPLETION PERIOD IN MONTHS 12.0
NAME OF TENDERER ALL COLOURED CELL IS TO BE FILLED ACCORDINGLY
ADDRESS, E-MAIL & MOBILE NUMBER OF TENDERER
S.N. ITEMS REQUIREMENT REMARKS
1 REGISTRATION (Any Contractor Registered in appropriate category with Central Government / Any State Government / Any Public Sector Undertakings or an Agency of National or International repute may tender but Registration with Infrastructure Development Authority will be essential after issue of Letter Of Acceptance.) Department
Registration No.
Date of Validity
2 ELECTRICAL LICENSE REGISTRATION Attach Valid Self Electrical License Or Sub Contractor's Electrical License With Affidavit (Attach An Affidavit As Per Format Prescribed In SBD-Annexure III, On Or After Date Of Tender, Duly Attested By An Executive Magistrate). Department
Registration No.
Date of Validity
3 LEGAL STATUS OF BIDDER Section 1 ITB 4.3 (a) of S.B.D (i) Individual/Partnership/Pvt. Ltd./Public Ltd/Joint Venture
(ii) Place of Registration.
(iii) Principal Place of Business
(iv) Power of Attorney of Signatory Bid
4 JOINT VENTURE (Bids From Joint Ventures Are Acceptable Only Above Rs. 10.00 Crores Project) The tenderer have to submit the Joint Venture documents as per eligibility criteria & other instructions issued vide Road Construction Department Letter No. 8131 (S) dated: 24.07.2012.
5 PERMANENT ACCOUNT NUMBER (PAN) Attach Copy of PAN
6 GST REGISTRATION Attach Copy of GST
7 COST OF BOQ (e payment only) Rs. 11,800.00 (Attach e-payment receipt of BOQ)
8 EARNEST MONEY DEPOSIT (BID SECURITY) Earnest Money Deposit (Bid Security) will be accepted only in online mode (Internet Payment Gateway). No other forms of Earnest Money Deposit (Bid Security) will be accepted. Amount To Be Entered (Rs. In Lakhs) Attach e-payment of Earnest Money Deposit (Bid Security).
9 WORK EXPERIENCE OF SIMILAR NATURE ( Building Work) Section 1 ITB 4.5 (A) (b) of SBD The completion certificate shall be issued by employer not below the rank of Executive Engineer or Equivalent.
10 QUANTITY WISE EXPERIENCE Section 1 ITB 4.5 (A) ( c ) of SBD MINIMUM QUANTITY / AMOUNT AS PRESCRIBED IN SBD
RCC+PCC : 752.89 Cum
Brick Work : 224.51 Cum
Earth Work+Local Sand : 352.1 Cum
Pile Work(300mm dia or above): 498.75 rm
Furniture : Rs. 33,29,919.00
Electrical Work +HVAC Work : Rs. 71,39,019.00
PHE Work : Rs 14,75,202.00
Lift Work : Rs 21,24,000.00
Fire-Fighting Work : Rs 3,47,993.00
11 ANNUAL FINANCIAL TURN OVER OF LAST FIVE YEARS ITB Clause 4.5 (A)(a) (Balance Sheet, Profit & Loss And Audit Report Duly Audited By CA) FY 2020-2021 Amount To be entered (Rs in Lakhs)
FY 2021-2022 Amount To be entered (Rs in Lakhs)
FY 2022-2023 Amount To be entered (Rs in Lakhs)
FY 2023-2024 Amount To be entered (Rs in Lakhs)
FY 2024-2025 Amount To be entered (Rs in Lakhs)
12 BANKER'S CERTIFICATE EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT FACILITIES (10% OF PROJECT COST) Section 1 ITB 4.2 ( i ) of S.B.D Certificate Issued By Bank As Per Format Prescribed In Sec-2 Of SBD, On Or After Date Of Tender
13 BIDDING CAPACITY (BC=A*N*3-B) Section 1 ITB 4.7 of S.B.D A = Maximum value of civil engineering works executed in any one year during the last five years (updated to the price level of the year indicated in Appendix) taking into account the completed as well as works in progress. N = Number of years prescribed for completion of the works for which bids are invited. B = Value (updated to the price level of the year indicated in Appendix) of existing commitments and on-going works to be completed during the next 12 Months(period of completion of the works for which bids are invited).
14 (A) AMOUNT OF EXISTING COMMITMENTS AND ONGOING WORKS Attach As Per Sec. 2- 1.4 (A) Of SBD, On Or After Date Of Tender (Bidder must decleare themselve their all exising commitment concealment of any fact shall be sufficient cause for rejection)
(B) AMOUNT OF WORK FOR WHICH BID ALREADY SUBMITTED Attach As Per Sec 2- 1.4 (B) Of SBD, On Or After Date Of Tender
15 AFFIDAVIT (I) Attach An Affidavit As Per Format Prescribed In Sec-2 Of SBD, On Or After Date Of Tender, Duly Attested By An Executive Magistrate.
(II) Attach An Affidavit As Per NIT, On Or After Date Of Tender, Duly Attested By An Executive Magistrate.
16 CHARACTER CERTIFICATE Attach a Valid Character Certificate of Tenderer Issued By Competent Authority.
17 UNDERTAKING (i) Investment of minimum cash up to 25% of the value of the work during implementation of the contract. Section 1 ITB 4.2 (ii) of SBD (I) Attach An Undertaking As Per Format Prescribed In Sec. 2 Of SBD.
(ii) Bid Validity : 120 days Section 1 ITB 15.1 of SBD (II) Attach An Undertaking As Per Format Prescribed In Sec. 8 Of SBD.
18 LITIGATION HISTORY Section 1 ITB 4.3 ( j ) of SBD As Per Format Prescribed In Sec. 2-1.11 Of SBD On Or After Date Of Tender.
19 PROPOSED METHODOLOGY AND PROGRAMME OF CONSTRUCTION Section 1 ITB 4.3 ( l ) of S.B.D Attach Descriptions,Drawings And Charts As Necessary.
20 TECHNICAL PERSONNEL Section 1 ITB Clause 4.5 B (b) Attach As Per Sec-2-1.6 Of SBD. Attach Necessary Certificate And Current Affidavit Of Both Employee And Employer On And After Date Of Tender, Duly Attested By An Executive Magistrate.
21 LIST OF KEY PLANTS & EQUIPMENTS Section 1 ITB 4.5 B (a) Attach As Per Sec 2-1.5 Of SBD (Max. Age 5 Years). Attach Owned Voucher/Cash Memo/Invoice And Affidavit In Case Of Leased/Hire On And After Date Of Tender, Duly Attested By An Executive Magistrate.
I, the undersigned, do hereby certify that all the statements made in the required attachements are true and correct.
INFRASTRUCTURE DEVELOPMENT AUTHORITY
(A GOVERNMENT OF BIHAR UNDERTAKING)
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Whatsapp Enabled Mobile Number
NIT - 10/TEN/IDA/26
Sl no. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.) 75,898,919.67
2 Total Non-Schedule Amount (Rs.) To be Quoted!
TOTAL AMOUNT Rs. 93,009,419.00
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
S.No. Particular Amount
1 Schedule Items 75,898,919.67
2 Non-Schedule Items
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
SCHEDULED ITEMS
S.No. BSR-01-01-22 DESCRIPTION OF ITEMS UNIT QTY RATE AMOUNT
1 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. cum 778.94 360.70 280,963.30
2 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m cum 584.20 123.90 72,382.91
3 2.27 Extra for every additional lift of 1.5 m or part thereof in :
2.27.1 Ali kinds of soil. cum 143.96 49.40 7,111.68
4 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. cum 120.00 287.30 34,476.00
5 2.29 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m
6 2.37. Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent (including the cost of chemical emulsion)
2.37.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor.
2.37.3.1 With Chlorpyriphos EC 20% with 1% concentration sqm 333.00 241.20 80,319.60
7 4.1 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.
4.1.3 1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cum 74.80 3,998.10 299,057.88
8 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). cum 45.96 2,975.20 136,746.02
9 4.11 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). sqm 75.00 245.60 18,420.00
10 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. sqm 75.00 436.60 32,745.00
11 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, sqm 309.00 283.30 87,539.70
REINFORCED CEMENT CONCRETE
12 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - all work upto Plinth level
5.1.1 1:1:2(1 Cement :1 coarse sand :2 graded stone aggregate 20mm Nominal size) M-25 cum 90.40 5,961.90 538,982.23
13 5.2 Reinforced cement concrete work in wall ( any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, adutments, posts and struts, etc. upto floor five level exculding cost of centring, shuttering, finishing and reinforcement
5.2.1 1:1:2 (1: Cement :1 coarses sand :2 graded stone aggregate 20mm nominal size) M-25 cum 195.82 6,943.50 1,359,683.37
5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
14 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. sqm 349.03 211.60 73,855.17
15 5.9.2 Walls (any thickness) including attached pilasters butteresses, plinth and string courses etc. sqm 1,025.46 375.10 384,648.92
16 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 1,518.88 437.50 664,507.90
17 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 925.19 404.70 374,423.14
18 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 908.85 494.40 449,334.69
19 5.9.7 Stairs, (excluding landings) except spiral-staircases. sqm 237.44 439.90 104,449.86
5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
20 5.22.7.A Thermo-Mechanically Treated bars. TMTC-500-8MM dia kg 29,518.15 94.50 2,789,465.23
21 5.22.7.B Thermo-Mechanically Treated bars. TMTC-500-10MM dia kg 35,421.78 92.60 3,280,056.89
22 5.22.7.C Thermo-Mechanically Treated bars. TMTC-500-12MM dia Kg 24645.6878462187 90.80 2,237,828.46
23 5.22.7.D Thermo-Mechanically Treated bars. TMTC-500-16,20,25 MM dia Kg 108,233.22 91.70 9,924,986.16
5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but exculding the cost of centering, shuttering, finishing and including retard setting of concrete, improve worksability without impairing strength and mixtures in recommended proportions as per IS: 9103 to accelerate, rainforcement, durability as per direction of Engineer-in charge Note:- Cement content considered in this item is @330 kg/ cum. Execess or less cement used as per design mix is payable or recoverable separately.
5.33.1 All works upto plinth level
24 5.33.1.1 Concrete of M-25 grade with minimum cement content of 330 kg/cum cum 179.07 5,063.40 906,709.11
5.33.2 All work above plinth upto floor V level
25 5.33.2.1 Concrete of M-25 grade with minimum cement content of 330 kg/cum cum 370.32 5,863.20 2,171,258.80
5.33B Add or deduct for providing richer or leaner mixes respectively at all floor levels.
26 5.33B.2 Providing M-30 grade R.C.C. instead of M-25 grade R.C.C.(266.10-194.20) cum 549.39 225.40 123,832.72
27 20.2A. Boring, providing and installing bored cast-in-situ reinforced of grade M-25 of specified diameter and length below the pile cap, to carry a safe cement concrete piles working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.(By Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).
28 20.3A.2 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem -A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead ineluding all lifts , all complete as per approved design and direction of (E/l) Each 113.00 190.20 21,492.60
29 20.6 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loadingplatform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
20.6.3 Group of two or more piles upto 50 tonne capacity
20.6.3.1 Initial test per test 2.00 66,227.90 132,455.80
30 6.1A Brick work with bricks of class designation 100A in foundations and plinth in : cum 294.51 5,017.90 1,477,821.73
31 6.1.12/1 Cement mortar 1 .:4 (1 cement: 4 coarse sand )
6.3A Extra for Brick work in superstructure above plinth level upto floor V cum cum 216.36 842.20 182,218.39
32 6.18A Half brick masonry with bricks of class designation 100A in foundations and plinth in :
6.18.3A Cement mortar 1:3 (1 cement: 3 coarse sand) sqm 142.56 621.50 88,601.04
33 6.19A Extra for half Brick masonry in superstructure above pinth level upto floor V level. sqm 142.56 89.70 12,787.63
34 6.21A Extra for providing and placing in position 2 Nos, 6 mm dia MS bars at every third course of half brick masonry (with F. P.S.bricks) sqm 142.56 113.60 16,194.82
35 6.47 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). cum 207.69 5,350.00 1,111,141.50
36 6.38 Providing and laying Autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand).The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. cum 11.95 6,233.20 74,499.21
37 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :
38 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :
39 9.6.2 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade-1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade 1, Type - II marked sqm 1.00 2,640.70 2,640.70
40 9.7 Providing and fixing panelling or panelling and glazing in panelled of panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates tobe measured) panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick
9.7.5.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination sqm 1.00 1,314.90 1,314.90
41 9.9 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including black enamelled ISI marked M.S butt hinges with necessary screws.
9.9.1 Second class teak wood
42 9.20 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 40.80 2,845.60 116,100.48
43 9.20. Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
9.21.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 18.00 1,641.50 29,547.00
44 9.40 Providing and fixing wooden molded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc . Complete
9.40.1 2nd Class teak wood
46 9.45 Providing and fixing teak wood lipping of size 25*3mm rmt 95.00 33.90 3,220.50
47 9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete
48 9.76 Providing and fixing bright finished brass 100mm mortice latch and lock with 6 lever handles with necessary screws etc complete (best make of approved quality) each 10.00 639.40 6,394.00
49 9.77 Providing and fixing bright finished brass 100mm moritce latch with one dead bolt and a pair of lever handles with necessay screws etc. complete each 5.00 519.00 2,595.00
50 9.82 Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. complete each 10.00 108.10 1,081.00
51 9.83 Providing and fixing IS: 3564 bright finished brass hydraulic door closer (best make of approved quality) with necessary accessories and screws etc. complete each 5.00 979.50 4,897.50
52 9.85 Providing and dixing bright finished brass casement window fastener with necessary screws etc. complete each 132.00 71.30 9,411.60
53 9.105 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both e
9.105.3 66 mm overall thickness Partition with 8 mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq cm, Bending Strength 100 kg/ sq cm sqm 10.00 1,488.60 14,886.00
9.1 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B), using 4 mm thick float glass panes for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished oF required size with necessary screws, all as per directions of Engineer-in-charge.
54 9.10.1 30 mm thick shutters sqm 10.00 2,506.90 25,069.00
9.7.7 Float glass panes.
56 9.120 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
9.120.2 30 mm thick pre laminated PVC door shutters sqm 5.00 2,293.40 11,467.00
57 9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:
58 9.24 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):
9.24.1 Rectangular or square sqm 10.00 173.90 1,739.00
59 9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete:
60 9.127 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
61 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid for separately). sqm 22.00 6,445.00 141,790.00
62 10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position andapplying a priming coat of approved steel primer using structural steel, etc. as required.
10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. Gates & similar works. KG 1435.00 114.60 164,451.00
63 10.36 Providing and fixing stainless steel (grade 304) railing made of hollow tubes, channels, plates etc, including welding, grainding, buffing, polishing and making curvature (wherever required)and fitting the same with necessary stainles steel nuts and bolts complete. i/c fixing the railing with necessary accessories & stailess steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitalbe arrangement as per approval of Engineer-in-charge ( for payment purpose only weight of stailess steel member shall be considered excluding fixing accessores such as nuts, bolts, fasteners etc.) kg 1750.00 546.80 956,900.00
64 10.42 Providing and fixing bolts including nuts and washers and Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. KG 1180.00 105.30 124,254.00
65 10.43 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) Metre 118.00 272.60 32,166.80
66 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias andCVsimilar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,includingrubbing, curing, moulding, nosing and polishing to edges to give etc. complete at all levels.
8.2.2.1 Area of slab upto 0.50 sqm sqm 15.72 4,242.90 66,698.39
67 8.12 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over20mm(avearage) thick base of cement mortar 1:4(1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
a Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. sqm 247.15 2,147.70 530,804.06
68 8.3 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
69 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
70 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. rmt 5.00 82.90 414.50
71 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sqm 342.72 795.00 272,462.40
72 11.41 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
73 11.52 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
a. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. sqm 5.00 5,908.40 29,542.00
74 12.55 X Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. Sqm 385.00 1,101.60 424,116.00
75 12.52X Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52x.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. sqm 1145.05 1,004.20 1,149,859.21
#REF! 12.82 Providing and fixing at all height false ceiling of 12.5 mm thick -tapered edge gypsum board conforming to IS : 2095 including -providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanized in accordance with zinc coating 120gm/sqm as per IS : 277 and consisting of angle cleats of size 25 mm wide x 16 mm thick with flanges of 22 mm and 27 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bots to the angle hangers of 25x10x0.5 mm of required length, and other end of angle hangerbeing fixed with nut and bots to rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450 mm centre to centre shall be be fixed in a direction perpendicular to G. I. channel with connecting clips made out of 2.64 mm dia x 230 mm long G. I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long . the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long dirve-all screws @ 230 mm interval including jointing and fixing to a flush of tapered and square edges of the gypsum board with recommended filler., paper tapes, finisher and two coats of primer suitable for gypsum board as per manufactures specification and also including the coat cutouts made with frame of perimeter channels suitably fixed all complete as per- drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting. sqm 5.00 738.30 3,691.50
76 12.52X Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52x.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. sqm 45.18 1,348.40 60,920.71
77 12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete each 5.00 189.40 947.00
78 13.11 12mm Cement Plaster of mix:
79 13.78A Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such asbare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. sqm 770.00 256.50 197,505.00
80 13.12 15mm cement plaster on rough side of single or half brick all of mix:
81 13.24 6mm cement plaster ot ceilig of mix:
82 13.40A Providing and applying plaster of pairs putty of 2 mm thickness over plastered sufrace to prepare the surface even and smooth complete sqm 4759.67 127.90 608,761.79
83 13.78 Applying one coat of cement primer of approved brand and manufacture on wall surface:
13.78.2 Distemper primer sqm 4760.00 38.70 184,212.00
84 13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade
13.92.1 Two or more coats on new work sqm 4760.00 86.40 411,264.00
85 13.101 French spirit polishing:
13.101.1 13.101.1 Two or more coats on works including a coat of wood filler. sqm 85.00 215.80 18,343.00
86 13.104 Polishing on wood work with ready made wax polish of approved brand and manufacture:
88 22.1 Providing and laying integral cement based treatment for water . proofing on horizontal surfaces at all levels as directed by Engineer-in-charge andB consisting of: 1) 1st layer of 20 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement:3 coarse sand) mixed with water proofing compund conforming to IS: 12645 in the recommnded proportion. Joints sealed and grouted with cement slurry mixed with water proofing compound conforming to IS: 12645 in proportions recommended by the manufacturer. II) 2nd'c!ass layer of 25 mm thick cement mortar 1:3 (1 cement:3 coarse sand) mixed with water proofing compound in recommended proportions. Ill) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreadidng @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
22.1.1 Using rough kota sotne. sqm 33.95 1,396.30 47,404.39
89 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge
22.2.1 Using rough kota stone sqm 77.89 1,752.40 136,494.44
90 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions. (ii) II nd course of 20 mm cement plaster 1:3 (1: cement :3 coarse sand) mixed with water proofing compound in recommended proportion. (iii) IIIrd course of applying blown or/ residual bitumen aplied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet ( Overlaps at joints of PVC shet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) sqm 409.20 480.60 196,661.52
91 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. Sqm 415.00 90.70 37,640.50
16.3 Supplying and stacking at site
92 16.3.1 90 mm to 45 mm size stone aggregate ( WBM) cum 62.25 841.00 52,352.25
93 16.3.6 Stone screening 13.2 mm nominal size (Type A) (GSB ) cum 62.25 800.10 49,806.23
95 16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density cum 553.50 487.00 269,554.50
96 11.79 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
11.79.1 (a) 80 mm thick c.c. paver block of M-35 grade with approved colour design and pattern. sqm 415.00 956.40 396,906.00
97 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). cum 15.93 7,998.80 127,420.88
98 CARRIAGE OF MATERIALS
99 DIFFERENCE IN COST OF MATERIALS
Plumbing & Fire Fighting Work
BSR 2022 BSR 2022. ITEMS:-
100 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast P or S trap, 10 Litre low level P.V.C. flushing cistern with manually controlled device(handle lever) conforming to IS:7231, with all fittings & fixtures complete including cutting and making good the walls and floors wherever required.
17.1.1. White vitreous chinaOrissa pattern W.C. pan of size 580x480mm with integral type foot rests. Each 3.00 4,470.90 13,412.70
101 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 9.00 5,504.30 49,538.70
102 17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern with fittings,standard size C.P.brass flush pipe,spreaders with unions & clamps(all in CP brass)including painting of fittings, cutting and making good the walls and floors where required.
17.5.1 a) Single half stall urinal basin with 5litre automatic flushing cistern. Each 5.00 6,469.00 32,345.00
103 17.7 Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required.
17.7.3 White vitreous china wash basin size 550 mm x 400 mm with single 15mm CP brass pillar tap. Each 9.00 2,530.30 22,772.70
104 17.10 Providing and fixing Stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittingsand brackets, cutting and making good the walls whereve required.
17.10.1 Kitchen sink with drain board
17.10.1.1 510 X 1040 mm bowl depth 250mm Each 0.00 5,231.50
105 17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tubeupto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. Each 9.00 299.40 2,694.60
106 17.28 Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete .
107 17.31 Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 9.00 1,068.50 9,616.50
108 17.33 Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. Each 1.00 713.30 713.30
109 17.34 Providing and fixing toilet paper holder.
110 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
17.70.1 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms Each 14.00 325.10 4,551.40
111 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.minimum water seal, weighing not less than 263 gms Each 8.00 146.30 1,170.40
112 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms Each 9.00 204.70 1,842.30
18.7 Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. .
Internal Work - Exposed on Wall
113 18.7.1 15 mm outer dia pipes. Metre 0.00 172.00
114 18.7.2 20 mm outer dia pipes. Metre 16.10 233.90 3,765.79
115 18.7.3 25 mm outer dia pipes. Metre 20.70 317.30 6,568.11
116 18.7.4 32 mm outer dia pipes. Metre 9.20 395.20 3,635.84
117 18.7.5 40 mm outer dia pipes. Metre 78.20 538.40 42,102.88
118 18.7.6 50 mm outer dia pipes. Metre 62.10 791.00 49,121.10
18.8 Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge.
Concealed work oncluding cutting chases and making good the walls etc.
119 18.8.1 15 mm outer dia pipes. Metre 1.00 278.20 278.20
120 18.8.2 20 mm outer dia pipes. Metre 64.40 350.80 22,591.52
121 18.8.3 25 mm outer dia pipes. Metre 9.20 463.10 4,260.52
122 18.8.4 32 mm outer dia pipes. Metre 0.00 549.80
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This including jointing of pipes & fittings with one step CPVC solvent cement trenching refilling& testing of joints complete as per direction of engineer in charge.
123 18.9.4 32 mm outer dia pipes. Metre 0.00 359.10
124 18.9.5 40 mm outer dia pipes. Metre 0.00 477.60
125 18.9.6 50 mm outer dia pipes. Metre 0.00 730.30
126 18.12 Providing and fixing GI complete with GI fittings including trenching and refilling etc.
18.12.6 50 mm dia nominal bore. Metre 30.00 572.60 17,178.00
18.16 Providing and fixing brass stop cock of approved quality complete.
127 18.16.1 15 mm nominal bore Each 0.00 303.80
128 18.16.2 20 mm nominal bore Each 5.00 328.00 1,640.00
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
129 18.18.2 20 mm nominal bore Each 2.00 397.40 794.80
130 18.18.3 25 mm nominal bore Each 9.00 399.20 3,592.80
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
131 18.17.1 25 mm dia nominal bore Each 9.00 532.30 4,790.70
132 18.17.2 32 mm dia nominal bore Each 2.00 589.90 1,179.80
133 18.17.3 40 mm dia nominal bore Each 1.00 707.30 707.30
134 18.17.4 50 mm dia nominal bore Each 2.00 878.20 1,756.40
135 1.18.48 Providing and placing on terrace (at all floor levels) Polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement amd making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Litre 1,000.00 9.70 9,700.00
136 18.49 Providing and fixing C.P.brass bib cock of approved quality conforming to IS : 8931. Each 1.00 434.20 434.20
137 18.51 Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms.
18.51.1 15 mm nominal bore. Each 1.00 708.40 708.40
138 18.53 Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931 a) 15 mm nominal bore
18.53.1 15 mm nominal bore Each 18.00 500.40 9,007.20
DRAINAGE- EXTERNAL
139 19.4 Providing and fixing square-mouth S.W. gully trap Class SP-1 complete with C.I. grating brick masonry chamber with grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
19.4.2 150x100mm size P type
19.4.2.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 2.00 1,908.90 3,817.80
19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
142 19.2.4 250 mm dia DWC pipe mtr 0.00 666.50
19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
146 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :
19.7.1 Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg).
19.7.1.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 5.00 7,914.70 39,573.50
147 19.8 Extra for depth for manholes
19.8.2 Size 120x90 cm
19.8.2.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Mtrs 0.00 6,776.30
148 19.27 Providing and constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design.
19.27.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 6.00 3,743.70 22,462.20
19.30 Providing and constructing brick masonry chamber for undergroundCI inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
149 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
150 19.30.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 1.00 4,266.80 4,266.80
RAIN WATER HARVESTING SYSTEM
151 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
24.1.2 Rocky strata including Boulders
152 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.2 150 mm nominal size dia meter 50.00 673.50 33,675.00
153 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 10.00 1,118.90 11,189.00
154 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 10.00 1,195.60 11,956.00
155 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. cum 10.00 1,195.60 11,956.00
TUBE WELL-Boring Depth 100mtr Consider
156 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level
24.1.1 All types of soil
157 24.1.2 Rocky strata including Boulders
158 24.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level
24.2.1 Rocky strata including Boulders
159 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
24.3.2 150 mm nominal size dia metre 70 660.10 46,207.00
160 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.2 150 mm nominal size dia metre 30 673.50 20,205.00
161 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,188.90 4,755.60
162 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,195.60 4,782.40
163 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum 4 1,195.60 4,782.40
164 24.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Cum 4 1,343.20 5,372.80
165 24.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. each 2 1,213.20 2,426.40
24.1 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
166 24.10.2 150 mm nominal size dia having minimum wall thickness 5.00 mm Metre 70 1,408.10 98,567.00
167 24.10.3 200 mm nominal size dia having minimum wall thickness 5.40 mm Metre 75 2,003.70 150,277.50
168 24.11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
24.11.2 150 mm nominal size dia metre 100 1,727.20 172,720.00
169 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hour 12 916.80 11,001.60
170 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
171 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete
172 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
173 18.31.1 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
18.31.1 100 mm diameter
18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
174 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 7,210.60 7,210.60
175 7183 Supply of Bentonite kg 500 2.80 1,400.00
176 ,026 Hiring charges of Bentonite Pump Day 4 3,000.00 12,000.00
Rain Water Harvesting Bore Well-Depth Consider 100mtr
24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level
24.1.1 All types of soil
24.1.2 Rocky strata including Boulders
179 24.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level
24.2.1 Rocky strata including Boulders
180 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
24.3.2 150 mm nominal size dia metre 70 660.10 46,207.00
181 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.2 150 mm nominal size dia metre 30 673.50 20,205.00
182 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,188.90 4,755.60
183 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,195.60 4,782.40
184 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum 4 1,195.60 4,782.40
185 24.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Cum 4 1,343.20 5,372.80
186 24.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. each 2 1,213.20 2,426.40
24.1 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
187 24.10.2 150 mm nominal size dia having minimum wall thickness 5.00 mm Metre 70 1,408.10 98,567.00
188 24.10.3 200 mm nominal size dia having minimum wall thickness 5.40 mm Metre 75 2,003.70 150,277.50
189 24.11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
24.11.2 150 mm nominal size dia metre 100 1,727.20 172,720.00
190 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hour 12 916.80 11,001.60
191 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
192 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete
193 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
194 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 7,210.60 7,210.60
FIRE FIGHTING WORKS
BSR 2022 CHAPTER - 27
Note- Following work is included in the scope of contractor 1) Contractor have to submit shop drawing of Fire Fighting work own cost before execution of work 2) All material test certicate should be submitted 3) All material make model and sample should be get approved from EIC before execution of work 4) Apply and getting Fire Audit report own cost is in contractor scope. contractor have to make arrangement to get tested of all fire fighting work and paper from fire deparment . After successful audit of Fire work final bill will be paid for fire fighiting work
Supplying, installation, testing and commissioning ofelectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
PIPES & ACCESSORIES
7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
199 9.1 Single headed Gunmetal Set 4 7,245.00 28,980.00
11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
203 13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete required. Each 4 1,236.00 4,944.00
14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
15 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
207 16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
208 17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required; -20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 -20 mm nominal internal dia gun metal globe valve & nozzle. -Drum and brackets for fixing the equipmets on wall. -Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
209 18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
210 19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
211 20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Nos 1 17,707.00 17,707.00
212 22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Nos 5 1,442.00 7,210.00
DISMANTLING AND DEMOLISHING
213 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. CUM 160 1,411.20 225,792.00
214 15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
15.7.4 In cement mortar CUM 240 823.70 197,688.00
215 15.25 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. SQM 1430 106.70 152,581.00
Sub Total` 49,192,662.79
GST ADD GST 5.36% ON ITEM BSR-2022 5.36% 2,636,726.73
Civil Work Total 51,829,389.52
ELECTRICAL Work
Make - All SOR material will be used as per BCD approved make as per approval of Engineer Incharge
216 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required.
217 1.4 Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, , modular plate, suitable size G.l. box etc as required. Point 8 1,248.00 9,984.00
218 1.5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr 1200 309.00 370,800.00
1.6 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr 0 523.00
1.7 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.
222 1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Mtr 25 557.00 13,925.00
224 1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire Mtr 50 660.00 33,000.00
227 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reeessed PVC conduit as required.
1.16 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit
1.17 TV cable in existing conduiting: Supply & drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in existing surface/ recessed steel/ PVC conduit as required. Mtrs. 0 42.00
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
234 1.24.4 3 pin 5/6 A socket outlet Each 15 112.00 1,680.00
235 1.24.5 6 pin 15/16 A socket outlet Each 7 183.00 1,281.00
236 1.24.6 Telephone socket outlet Each 2 131.00 262.00
1.24.7 TV socket outlet Each 0 131.00
237 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 33 358.00 11,814.00
238 1.26 Supplying and fixing of modular Blanking plate on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd. Each 15 34.00 510.00
239 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
244 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Each 30 414.00 12,420.00
245 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Each 66 531.00 35,046.00
246 1.33 Supplying and fixing 2 pin, 5/6 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. Each 234 64.00 14,976.00
247 1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required. Each 20 80.00 1,600.00
1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Each 0 134.00
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Each 0 135.00
248 8.14 Supply and fixing extra down rod for ceiling fan of 1 metre length G.l. pipe, 15 mm dia, heavy guage including painting etc. as required. Each 33 409.00 13,497.00
1.5 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1.50.1 Upto 450 mm sweep Each 0 296.00
1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 0 129.00
249 1.55 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos.3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. Each 10 632.00 6,320.00
250 1.59 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
251 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
2.8 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.5 6 way , Double door Each 0 2,197.00
252 2.8.6 8 way , Double door Each 6 2,591.00 15,546.00
253 2.8.7 12 way , Double door Each 1 2,314.00 2,314.00
2.9 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way (4 + 12), Double door Each 4,184.00
2.1 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2.10.1 4 way (4 + 12), Double door Each 0 7,857.00
2.10.3 12 way (4 + 36), Double door Each 0 13,572.00
2.12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.15 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.16 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.17 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.18 Supplying & Fixing of following rating four pole (three phase and neutral) 415 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 30 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
262 2.27 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. Each 39 1,162.00 45,318.00
2.19 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 0 1,513.00
263 2.26 Supplying and fixing 30 A/32A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A/32A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 5 4,637.00 23,185.00
264 2.2 Providing and fixing M.V. danger notice plate of 200x150mm ,made of mild steel at least 2mm thick ,vitreous enameled white on both sides ,and with inscription in single red colour on front side as required. Each 15 214.00 3,210.00
DSR 4.1 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
265 4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness RM 75 686.00 51,450.00
266 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness RM 100 866.00 86,600.00
DSR 4.2 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
267 4.2.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,105.00
268 4.2.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,544.00
DSR 4.3 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
4.3.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,281.00
4.3.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,826.00
DSR 4.4 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
4.4.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,498.00
4.4.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 0 2,110.00
269 8.15 Supply and installation of regular/standard model A.C.\ ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 12 2,482.00 29,784.00
270 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required Each 10 3,670.00 36,700.00
Networking- scheduled items
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
272 1.58 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1.58.1 1 run of cable Metre 250 52.00 13,000.00
LIGHTING FIXTURES
5.7 Supplying and fixing recess mounted following types led downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
275 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required
276 5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required . NOS. 102 2,663.00 271,626.00
277 5.3 Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminum housing and complete with integrated electronic driver etc directly on wall ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. (For Non-residential building) NOS. 25 762.00 19,050.00
278 5.1 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. NOS. 15 1,275.00 19,125.00
279 5.13 Supplying and fixing post top / gate light (width 250/ 300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) NOS. 15 1,399.00 20,985.00
280 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.18 Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
282 6.1.7 20 watt LED lamp Each 15 267.00 4,005.00
283 6.1.4 9/10 watt LED lamp Each 5 161.00 805.00
284 BCD SOR-23 5.2 Supplying and fixing 2'X9 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Supplying and fixing 4'X20 watt LED batten each 9 492.00 4,428.00
285 MP-23 31.17 Supplying, fixing & testing of approved make flexible LED strip comprising of 60 LED per meter W/O driver for direct mounting complete with all accessories including connection lead, fixing, connection as required. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
31.17.1 + GST Flexible LED strip 24Watt/25Watt - 5 M indoor cove light W/O Driver IP 20 -33 Each 28 1,458.48 40,837.44
286 MP-23 31.18 Supplying, fixing & testing of approved make Power supply for LED strip
31.18.1 + GST Power supply 25Watt/30Watt for LED strip IP25/IP33 Each 28 628.94 17,610.32
FIRE ALARM SYSTEM ( DSR Items)
INTELLIGENT FIRE ALARM SYSTEM
(Make - Honeywell, Siemens, Notifier, Bosch as per approval of EIC)
287 17.2.1 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
17.2.1.2 Two Loop Panel. Each 1 239,225.00 239,225.00
288 17.2.3 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. Each 1 108,688.00 108,688.00
289 17.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Each 51 2,858.00 145,758.00
290 17.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Each 10 276.00 2,760.00
291 17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Nos 5 3,871.00 19,355.00
292 17.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. Nos 5 3,506.00 17,530.00
17.2.17 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Nos 0 5,740.00
17.2.19 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Nos 0 1,600.00
293 17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required Meter 765 173.00 132,345.00
DSR-25 10 KVA UPS
294 26.1.4 Supplying of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input,Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance,Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt / VA, Amp and Voltage power parameters etc.
UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc Make- Vertiv, APC, Hitachi, Numeric or approved equivalent as per approval of EIC Nos 1 168,506.00 168,506.00
Make- Bosch, Ahuja, Honeywell or approved equivalent as per approval of EIC.
295 28.3.1 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. Each 1 132,115.00 132,115.00
296 28.3.2 Supplying, installation, testing & commissioning of 3/6W ceiling speaker complete as required Nos 57 1,025.00 58,425.00
28.3.3 Supplying, installation, testing & commissioning of 3/6W metal box ceiling/wall speakers complete as required. Nos 0 1,891.00
28.3.9 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required Nos 0 85,450.00
297 39.23.3 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8 mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 15U rack Nos 1 13,330.00 13,330.00
298 MP 23 53.3.5 + GST Supply, installation, testing and commissioning of 480W power amplifier with 100,70V speaker OP, combination XLR/RCA line in line out connectors. Speaker OP short circuit protection.(with require mounting arrangement) Each 1 63,537.10 63,537.10
299 DSR-25 28.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm mtr 140 61.00 8,540.00
301 Make- Hikvision, CP Plus, Honeywell or approved equivalent as per approval of EIC
302 39.11 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D (Make- D-link /Digsol/ Zyxel /HP) Nos 16 5,278.00 84,448.00
303 MP 23 54.28.1 + GST Supply, installation testing and commissioning of 24 port PoE switch with 4 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP Cat. 5, Cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 56 GBPS, maximum 64 bytes packet forwarding rate, 41.7mbps, Ports 1 to 24 compliant with 802.3 at (Make- D-link / Zyxel /HP) Nos 1 41,200.00 41,200.00
DSR 25 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent )
304 39.12.1 Copper Patch Cords of length 1m (3ft) Nos 250 151.00 37,750.00
DSR 25 40.5 Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :- 1)Type of Camera: Dome Camera 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night. 9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
DSR 25 40.5 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device,
DSR 25 40.5 19) Edge Analytics : Tripwire, Intrusion, Motion Detection 20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF
DSR 25 40.5 25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 27) Ethernet: 1 RJ 45 10/100 Ethernet port 28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 30) Enclosure: IP67 weather proof, IK10 31) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
305 40.5.1 4MP/3MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera. Nos 20 6,800.00 136,000.00
DSR 25 40.6 Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc :- 1) Type of Camera: Bullet Camera 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Lens Type & Focus: as given below. 9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 Mtrs for colour view in night. 10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
DSR 25 40.6 11) Wide Dynamic Range: WDR (120dB or more) 12) Digital Noise Reduction: DNR (2D/3D) On/Off 13) Streaming: Triple streaming, configurable 14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 16) Profile Management: User configuration import, export 17) Security: User Authentication, Digital Water Marking 18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 19) Recording Management: Format SD, overwrite, storage management, video to NAS device
DSR 25 40.6 20) Edge Analytics: Tripwire, Intrusion, Motion Detection 21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 22) Alarm Support: It should have 1/1 Alarm In/ Out Port 23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/ AAC/ G.726 audio compreesion 24) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 25) System Capability: ONVIF 26) VMS: Camera shall support open source VMS 27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, , video encryption, IP/MAC filtering, HTTPS, trusted upgrade.
DSR 25 40.6 28) Ethernet: 1 RJ 45 10/100 Ethernet port 29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 30) Power Requirement: 12VDC/24V DC/PoE (802.3af)/ePoE 31) Enclosure: IP67 weather proof, IK10 32) Operating Condition: Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 33) IR life: 40000 hours or higher 34) Video Bit rate: 32 KBPS - 8 MBPS or better 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
306 40.6.1 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) outdoor bullet Camera eACH 5 12,525.00 62,625.00
307 40.11.2 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1 /4/ 8/9/16/25 /36/64, 2nd screen: 1/4/8/9/16 Nos 2 82,600.00 165,200.00
308 40.12.2 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 6TB (Terabytes) Nos 2 16,376.00 32,752.00
309 42.4.3 Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. 55 inch or larger (Make- LG, Samsung, Dell, HP or approved equivalent) Nos 1 82,057.00 82,057.00
310 39.23.3 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 15U rack (Make- D link, Digisol, Molex or approved equivalent) Nos 1 13,330.00 13,330.00
MP 23 38.14 Supply, installation testing and commissioning of High-Speed HDMI corrosion-resistant connector & braided cable, Supports Ethernet, 3D, 4K video, computers and other HDMI-enabled devices Black as required to complete the job as mentioned below :- (Make- Kramer, Honeywell, Bluerigger, Belkin or approved equivalent)
311 38.14.2 + GST 2 Metre, HDMI cord Each 1 2,125.18 2,125.18
312 38.14.5 + GST 15 Metre, HDMI cord Each 1 12,628.36 12,628.36
313 1.58.1 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent ) mtr 2000 52.00 104,000.00
314 1.21.2 Supplying and fixing of following sizes of medium class 25 PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. mtr 2000 120.00 240,000.00
315 39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U rack (Make- D link, Digisol, Molex or approved equivalent) Nos 5 6,939.00 34,695.00
316 39.23.2 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 9U rack (Make- D link, Digisol, Molex or approved equivalent) Nos 1 8,960.00 8,960.00
317 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent ) Each 5 5,278.00 26,390.00
318 DSR 25 39.7 Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for Low Density use having features and specifications etc. as mentioned here under - Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal /Enterprise , WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Should also work as Standalone and must be Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. (Make- zyxel/Arista/HP/ CISCO) EACH 8 22,739.00 181,912.00
319 DSR-25 39.14 Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent ) EACH 66 212.00 13,992.00
Earthing and Cabling
SUB HEAD A - DSR ITEMS
EARTHING AND LIGHTING ARRESTER
320 BSR 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. set 12 6,884.00 82,608.00
321 BSR 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. set 6 13,721.00 82,326.00
322 BSR 3.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) mtr 80 1,026.00 82,080.00
323 BSR 3.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) mtr 150 133.00 19,950.00
324 BSR 3.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. mtr 10 1,180.00 11,800.00
325 BSR 3.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. mtr 20 195.00 3,900.00
326 BSR 3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. mtr 100 53.00 5,300.00
327 BSR 4.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Each 10 416.00 4,160.00
328 BSR 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) mtr 150 102.00 15,300.00
329 BSR 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) mtr 140 145.00 20,300.00
330 BSR 4.11 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. Each 6 274.00 1,644.00
331 BSR 4.13 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Mtr 30 1,530.00 45,900.00
DSR 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
333 7.1.2 Above 35 sq. mm and upto 95 sq. mm Mtr 0 405.00
334 7.1.3 Above 95 sq. mm and upto 185 sq. mm Mtr 15 422.00 6,330.00
DSR 7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
336 7.2.2 Above 35 sq. mm and upto 95 sq. mm Mtr 15 286.00 4,290.00
337 7.2.3 Above 95 sq. mm and upto 185 sq. mm Mtr 5 304.00 1,520.00
DSR 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required.
339 7.5.2 Above 35 sq. mm and upto 95 sq. mm Mtr 10 57.00 570.00
340 7.5.3 Above 95 sq. mm and upto 185 sq. mm Mtr 5 77.00 385.00
DSR 7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface and overhead as required.
341 7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Mtr 150 55.00 8,250.00
342 7.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Mtr 30 130.00 3,900.00
7.7.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Mtr 0 153.00
8.1 Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refillinq the trench etc as required.
344 8.1 Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as reauired.
346 DSR 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
357 14.14 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
14.16 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
TOTAL OF SUB-HEAD A
SUB HEAD B - SCHEDULE ITEMS
361 7.8 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
41.4 XLPE insulated FRLS heavy duty power cable Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor
Safety Equipments & Accessories
375 MP SOR-24 42.77 Rubber mat- Supply of rubber mat 2 x 1.0Mtr, 1100V tested each 15 1,913.00 28,695.00
376 MP SOR-24 42.83 Shock instruction chart -Supply of shock instruction chart duly framed with glass, as reqd. each 4 539.00 2,156.00
377 MP SOR-24 42.78 Hand gloves -11KV Supply of hand gloves 11KV tested each 2 1,077.00 2,154.00
378 MP SOR-24 42.82 First aid box- Supply of first aid box complete with medicine & bandage as per specification. set 1 1,646.00 1,646.00
Substaion wok included follwing works Following items are under the scope of contractor's work and no extra payment will be made for same 1) Apply and getting NOC from electrical inspector at own cost 2) Providng green/ installation card with electrical license 3) Getting work order before start of HT work and NOC from SBPDCL at own cost 4) Energizing the transformer after application of meter from parent deparment through SBPDCL.
160 KVA, 11KV/ 415V OIL TYPE DISTRIBUTION TRANSFORMER
Supply of following capacity (continous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site . The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.
Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature;
c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers.
Make- Red Phase, E wave, Infra Power or approved equivalent as per approval of EIC
379 160 KVA TRANSFORMER SET 1 284,474.00 284,474.00
RATES from Electrical NBPDCL Vetted copy
382 11 KV PIN INSULATOR with pin nos. 12 118.00 1,416.00
383 11 KV V cross arm nos. 4 796.81 3,187.24
384 11 KV Top insulator bracket nos. 4 268.41 1,073.64
385 back clamp for V and top nos. 8 133.56 1,068.48
386 ACSR Rabbit conductor km. 0.3 48,722.22 14,616.67
387 Transformer DP Top and base channel set 2 4,201.50 8,403.00
388 AB Switch channel set 2 3,025.88 6,051.76
389 HG Fuse channel set 1 3,025.88 3,025.88
390 Clamp for channels nos. 12 104.73 1,256.76
391 Transformer fastening angle nos. 2 1,977.71 3,955.42
392 back clamp for fastening angle nos. 4 154.69 618.76
393 Earthing materials set 3 1,822.00 5,466.00
394 11 kv AB Switch 400 ampere set 1 16,461.00 16,461.00
395 lightening arrester set 1 1,046.53 1,046.53
396 HG Fuse set set 1 7,382.69 7,382.69
397 Danger board nos. 1 68.00 68.00
399 Tapping Bracket nos. 6 728.45 4,370.70
400 11 kv Disc insulator nos. 4 448.00 1,792.00
402 Sundries LS 15,000.00
403 Contigency @ 2% of A 10,057.12
404 C. Transporation @ 4% of A 20,114.25
406 Labour cost @ 10% of A 50,285.62
407 Labour Cess 1% of total schedule rates 2,183.82
DIESEL GENERATOR SET
Make- Kirloskar, Mahindra, Cummins of approved equivalent as pe approval of EIC
DSR 2025 Supply of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as perrelevant IS Code etc. and consisting of the followings:
(A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital disPlate for following:
(i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
(G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( L-N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set. 7. Fuse/ MCB for instruments. 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
9. Main supply failure monitor. 10. Supply failure timer. 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
Make- Daikin, Carrier, O General, Mitushubishi or approved equivalent
DSR-2025 Contractor have to design and submit shop drawing of HVAC and get is approved before start of work
HI - WALL SPLIT SYSTEMS
DSR 8.2 Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) including outdoor stand if required..
409 32.2.2 1.0 TR with 5 Star BEE Rating Each 2 40,580.00 81,160.00
BCD 1 Split ac (Inverter Model, Cooling Only) - Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410 A . The condensing unit working range should be capable for providing cooling between +/- 5 deg C to 50 deg C & heating within 0 deg C to 15 deg C including connection of copper pipe of required size upto 3 mtr, insulation, cordless remote control , auto air swing louvers, connection copper lead wire , condensed water outlet pipe 2 mtr complete etc as required. Outdoor / indoor units should be of same make . The cost includes contractor profit, labour cess, supply , transportation cost, installation, testing and commissioning cost including outdoor stand if required.
CASSETTE TYPE SPLIT UNITS
2.0 Cassette AC (Ceiling suspended / mounted cassette type 4 way unit with inbuilt drain pump & decorative panels- Supply installtion testing and commissioning of split type ceiling cassette air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refreigerant R 410 A / ecofriendly green gas only, cordless remote control. auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr, excluding connection copper pipe of required size , insulation , floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/ indoor units should be of same make. The cost includes contractor profit, labour cess, supply, transportation cost, installation, testing and commissioning cost including outdoor stand if required.
BCD-23 AR COPPER REFRIGERANT PIPING
9.0 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
415 9.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 100 560.00 56,000.00
416 9.1 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 212 693.00 146,916.00
417 9.1 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 100 813.00 81,300.00
418 9.1 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 212 1,031.00 218,572.00
419 9.1 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 161 1,049.00 168,889.00
420 9.1 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 58 1,150.00 66,700.00
421 9.1 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 161 1,473.00 237,153.00
422 9.1 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 58 1,640.00 95,120.00
7.0 Drain piping :-· Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification .
424 MR SITC of Stand for the outdoor unit- For Hiwall Unit/Cassette Each 28 1,500.00 42,000.00
MP SOR 2024 - 46.44 Fresh air in line fan- Fresh air in line fan: - Supply, installation, testing and commissioning of fresh air inline fan.
425 46.44.1 100 CFM -100 CFM (static pressure upto 20 mm) EACH 5 5,473.00 27,365.00
BCD APPROVED RATE
17.0 Ducting:- Supply and fixing of site fabricated GI sheet metal ducts in accordance with the approved shop drawings and as required as per specifications. GI sheet will be as per 15-277. All necessary GI /MS supports using thread rods (as directed). Angle, flat, and anchor bolts, food grade neoprene gaskets, food grade adhesive included in the scope.
427 18.0 Thermal insulation :- Supplying and fixing of following thickness of mat finish closed cell nitrile rubber (class "1") insulation on existing duct after applying two coats of cold setting adhesive complete as per specifications and as required.
LIFT (Schedule Items)
MP 2024 44.1 Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and fulfilling following requirements. (i) Type: Passenger lift. (ii) Load: As specified elsewhere from 4 passengers (272Kg) to 26 passengers (1768Kg) (for each person standard weight 68Kg.). (iii) Speed: 1.00 metre/sec. or less as required. (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software. (v) Motor/machine: Permanent magnetic synchronous gearless motor.
(vi) Operation: Simplex collective selective with/without lift attendant. (vii) Total rise: About 3 mtrs. (approx) two stops only. (viii) Landings: All floors on same side. (ix) Floors served: G+1. (x) Signals: Digital car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car. (xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately. (xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xvi) Car door: S.S. (stainless steel) hairline finish centre/telescopic opening door with vision panel. (xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with vision panel. (xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams. (xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides. (xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform. (xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights (xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided). (xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car. (xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room.
(xxv) Emergency alarm: Battery operated alarm bell system in lift car & control room / ground floor. (xxvi) Position of machine room: Directly above the hoist-way. (xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V 1phase 50Hz terminated in machine room. (xxviii) Fire man switch : Fire man switch at machine room/terminal landing (xxix) All car panel buttons and all floor switches must be with Braille language as per lift act. (xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed. (xxxi) Spring buffer/hydraulic buffer shall be provided (xxxi) Spring buffer/hydraulic buffer shall be provided (xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxxiv) In the hoist way fascia plate shall be provided. (xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level. (xxxvi) Car top safety barricade shall be provided. (xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure. (Make- Otis, Kone, Schindler or approved equivalent as per approval of EIC)
Add extra to item no. 44.1 for every additional floor beyond initial G+ 1 floor (additional stops beyond two stops) provides all necessary additional parts/equipments as per manufacturer's requirement.
429 44.3.1 + GST @ 18% Cost for each additional floor : upto 9 stops (For 4-10 Passengers) Each 4 79,650.00 318,600.00
Add extra to item no. 44.1for machine room less (MRL) lift in place of machine room directly above the hoist way.
430 44.4.1 + GST @ 18% Extra cost for machine room less (4-13 Passenger) Each 2 159,300.00 318,600.00
ELEVATION - WORK
The fixing details are to be approved by the E/I. Shop Drawings / samples are to be approved by the E/I
Make- Saint Gobain, Modiguard or approved equivalent as per approval of EIC
431 25.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. kg 4210.46 414.30 1,744,393.58
Mild Steel Work:
432 10.1 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
10.14.2 Hot finished seamless type tubes Kg 24500 206.35 5,055,575.00
433 10.3 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.
434 Analysis Add SBPDCL Supervision Charge (B) Job 105,413.00
Total Schedule Amount (Rs.) (A+B) 75,898,919.67
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
NON-SCHEDULED ITEMS
S. No. ITEM NO. DESCRIPTION OF ITEMS UNIT QTY Quoted Rate In Figure(Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Rate In Word (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Amount (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect)
1 N.S Providing and fixing of 12 mm thick wooden ply paneling with or without frame so as to receive a plain and even surface in exact plumb line , covered with 1mm thick laminate finished of approved shade and make as per the design and as directed by the Architect in approved style and patter Sqm 460.00
2 N.S. Providing and fixing plywood partition of appropriate size having thickness of 75 mm, made up of 50 mm x 38 mm teakwood supporting members at a vertical distance of 0.9 m c/c and horizontal distance of 0.9 m c/c covering on both face with 19 mm thick Plywood Conforming to ISI-303 finished with 1.2mm thick Laminate of approved make, shade on both side, & 63mm high. aluminum skirting finished with powder coating matching to laminate including pasting, screwings, cutting, jointing, finishing, fixing to the walls etc. as shown in the drawing and design provided by the Architect, and antitermite treatment to wood, plywoods and MDF etc. complete as directed by Engineer -In-Charge. Sqm 340.00
3 NSI Glass partition - Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including providing and fixing top & bottom arrangement and making necessary holes etc. for fixing required partition fittings, all complete as per direction of Engineer-in-charge sqm 120.00
4 Door- Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing door machine, Door handle, lock and stopper. arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
NSI Door - 1500mm - DoubleDoor- W1500mmx H2400mm Nos 4.00
Plumbing & Fire Fighting Work
5 MR-01 Providing & fixing S.S. health faucet for ablution with 1.2 meter long PVC tube, hand shower, couplings, wall hook and other accessories of quality and make as approved by architect. 9.00
6 MR-02 Providing and fixing Heavy Class SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT & FD as approved by architect and complete in all respect..
7 Size 100 mm X 100 mm 22.00
8 MR-03 Providing and fixing Heavy Class Cockroch Type SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT as approved by architect and complete in all respect..
Size 127 mm X 127 mm 0.00
INTERNAL DRAINAGE
9 MR-04 Providing, fixing, jointing, testing and commissioning UPVC (Class B) Rain water downtake pipe conforming to IS:13592 cut to required lengths including all necessary fittings and specials.UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab and making good wherever required. (All major MS structure to hold the stack with fixing including anchor fasteners,sand, cement etc is included in this item).
110 mm dia 77.25
MR-05 Providing, fixing, jointing and testing UPVC soil, waste, vent pipework comprising UPVC pipe conforming to IS :4985-1983 of class 3 ( 6kg/cm2) as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps, suitable elbow with suitable extension piece for drain point and other specials jointing with cement solvent, chasing, cutting and making good the walls & floors pipes laid in floors shall be encased with 40 mm thick concrete all around, complete in all respects including testing of complete installation.(All major MS structure to hold the stack with fixing including anchor fasteners, sand, cement etc is included in this item)
10 110 OD 6 kg/cm2 (Class III ) 160.50
11 40 mm dia 6 kg/cm2 (Class III ) 13.80
12 50 mm dia 6 kg/cm2 (Class III ) 13.20
MR-06 Providing and fixing UPVC/SWR trap (P trap) of self cleaning design as per IS:13592 : 1992 complete including cost of cutting and making good the cutouts in walls and floors etc.including cutting and making good the walls and floors wherever required complete as approved by architect and complete in all respect. as approved by architect and complete in all respect.
13 110 mm inlet and 110 mm outlet 14.00
14 MR-05 Providing and fixing floor drain made out of 75x50 mm OD uPVC. elbow connected to uPVC pipe complete as per direction of Project Manager as approved by architect and complete in all respect as approved by architect and complete in all respect. 8.00
15 MR-07 Providing and fixing Inlet Fitting for Urinal trap, formed out of 110 mm PVC pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 including cutting and making good the walls and floors wherever required as approved by architect and complete in all respect.. 5.00
16 MR-08 Providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as required as approved by architect and complete in all respect.. 1.00
17 MR-09 Providing and fixing cleaning eye 110mm dia on horizontal UPVC soil & waste pipes of 300 mm long UPVC pipe with one plain end lead caulked in to the collar of UPVC pipe and the other end with flange which in covered by neoprene rubber gasket and blank flange, complete with nuts, bolts etc and hot dip galvanization after fabrication to the satisfaction of Project Manager as approved by architect and complete in all respect..
100 mm dia 10.00
DRAINAGE- EXTERNAL
MR-10 Providing & Fixing DWC ID SN-8 Pipe(HDPE Black Pipe) with Coupler & Rubber Ring as per IS:16098(PART 2)
18 150 mm Dia mtr 70.00
19 200 mm Dia mtr 22.00
20 250 mm Dia mtr 0.00
21 NS-1 Providing and fixing self glowing Exit sign board size 350x200mm single side painted made of luminescent safely, rigid sheet in standard colour photo, luminescent sheet made of crystals consisting mainly sulphide in protective glass like sheet green and yellow crystal luminescent (glass in dark) by action of light. Each 4.00
TUBE WELL-Boring Depth 100mtr Consider
22 MR Supply , Installation of Electronic chlorinator complete as directed by Engineer-in-Charge. Set 1
FIRE FIGHTING WORKS
23 MR-22 Providing, Installation, Testing and Commissioning of Gun Metal / Bronze Ball Valves screwed ends of following sizes as required. (For sprinkler drain )as approved by architect and complete in all respect. (MAKE - ZOLOTO , SANT, EQV.) Nos 5
MR-23 SITC weather proof M.S cabinet size 1350 mm x 900 mm x 600 mm
24 Supplying, installation, testing and commissioning of weather proof M.S cabinet size 1350 mm x 900 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the followingas approved by architect and complete in all respect. (Make - Exflame, Swastic, Safeguard)
The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade. Each 5
25 MR-24 Supply, installation, testing and commissioning of ISI marked (IS:15683:2006) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specificationsas approved by architect and complete in all respect.(Make - Exflame, Safex, Safeguard, Eqv.) Each 10
26 MR-25 Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed conforming IS : 15683:2006as approved by architect and complete in all respect.(Make - Exflame, Safex, Safeguard, Eqv.)
4.5kg capacity cylinder Each 10
PLUMBING WORK FOR HIGH SIDE
SUBHEAD - I- WATER SUPPLY PUMPS & EQUIPMENT
Submersible water transfer pumps
27 Supplying, installing, testing and commissioning of submersible water transfer pumps in Underground water tanks, having SS casing, SS impeller, SS shaft with mechanical seal, directly coupled with motor, 2900 rpm including pressure gauge on delivery line with gunmetal isolation cock, nuts, botls including float type level controllers, electrical control panels fabricatd from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Each pump shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C. Electric supply and shall be of the capacity as under One Set (1W+1S), including all necessary piping, valves and gauges. Vibration elimination pads shall be included as part of quoted rate. Control and Power Cable from pump to panel to be in plumbing contractor scope. Control cabling from OHT to UGT to be in electrical contractor scope. Routing and location to be provided by plumbing contractor at site. Pumps shall be "ultra low noise" with a db level of not more than 60 db
28 MR-11 Domestic Riser Sump Pump(Open Well Pump) Capacity : 100 LPM Each Pump (1 Working + 1 Standby) @ 45 M head. (location at UGT ) Make-Ebara Set 1
Receiving, unloading, storage, assembly, erection, testing and commissioning of SS/CI submersible pumps for domestic water pumping system comprising of: as approved by architect and complete in all respect.
Supply, installation, testing and commissioning of free standing vertical type electrical submersible pump sets of following capacity capable of domestic water supply in tube well, with water cooled electric motor for effective cooling, the wearing parts such as Impeller, shaft sleeve, pump casing etc. shall be C.I & Impeller bolt shall be AISI 316 and of adequate power for operation on 415+ 1 volts, 3 phase, 50 Hz AC electric supply including fixing of delivery pipe with a flanged outlet. The cost will include providing and fixing suitable standard electrical panel from the same manufacturer as the pump, including float type level controller for level control and for cyclic operation of pumps, all electrical cables including submersible cables of required length and making all necessary electrical connections, terminations etc complete in all respects.
The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head.
Pump suitable for domestic water
29 MR-12 For tube well water supply Capacity :165LPM Each Pump (1 Working) @ 56 M head (location in tube well). Make-Ebara No. 1
SUBHEAD -VIII - MISCELLANEOUS ITEMS
MR-13 Providing and fixing M.S. puddle flanges (fabricated of 750 mm long pipe pieces) to R.C.C. water tanks wall / slab. The entire fitting shall be hot dipped galvanized (Flanges shall confirm to BS10 Table E) as approved by architect and complete in all respect.. .
30 25 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 6
31 40 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 4
32 50 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 4
33 65 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 2
34 80 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 4
35 100 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 2
36 150 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 1
37 MR-14 Providing and fixing in position G.I. vent with brass mosquito proof coupling and air filter including return bend, complete as required. The entire fitting shall be hot dip galvanizedas approved by architect and complete in all respect.
100 mm dia Nos. 4
38 MR-15 Providing, testing & commissioning of dial type pressure gauge with pressure scale of 0 to 15 kg / cm2. Provision of isolation cock suitable for pressure of 15 kg / cum2 shall be included in cost. No. 4
39 MR-16 Supply complete testing kit with all chemicals complete suitable for conducting test on water quality. The test kit shall be suitable to measure TDS, pH, Hardness, Iron content and other parameters (Make : Ion Exchange)as approved by architect and complete in all respect.. No. 1
40 MR-17 Providing & fixing in position Vane Type mechanical water flow meter for following pipe sizeas approved by architect and complete in all respect..
UPTO 50 mm dia No. 1
41 MR-18 Providing, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.
25mm dia Each 1
MR-19 Providing and fixing Expansion flexible bellows between existing puddle flange in water tank retaining wall and proposed puddle flanges as mentioned under item No. 3 above. The bellow flanges shall match with exiting puddle flanges at site as approved by architect and complete in all respect.
42 50 mm dia Each 1
43 65 mm dia Each 1
44 MR-20 Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions as approved by architect and complete in all respect.. Set 2
To switch on the pumps (including tube well pumps 2 nos., Domestic Water Treatment etc.) To cut off the pump when the level in the receiving water tank is high and switch off the pumps when the level of water in the supply water tank is low.
To indicate 3 levels of water in all tanks through a control panel with LEDs
To start the pumps in a cyclic order.
The system shall be complete to ensure automatic quotation of pump in accordance to water level in respective tanks.
The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item
45 MR-21 Supply, installation, testing and commissioning of tanker inlet connection complete with 80 mm dia GI inlet piping, hose inlet connection, MS cabinet enclosure (epoxy painted after fabrication), pad locking arrangement, inlet flexible hose complete with all necessary arrangementas approved by architect and complete in all respect.. Nos 1
Electrical Work
LIGHTING FIXTURES
SUB HEAD D - NON SCHEDULE ITEMS
46 MR Supply installatin testing and commissioning of 45/50 Watt Recessed LED (ROUND) Light Fitting Make- Philips, Wipro, Orient, HPL or approved equivalent as per approval of EIC NOS. 12
47 MR Supply installation testing and commissioning of Pendent light with OEW recommended LED Bulb (Make- Wipro BeuHome BP03, PHILIPS Vivid Pendant (582024), Jaquar Pendant JNL-COP-SLPEA031BE27, Philips, Wipro, Orient, HPL or approved equivalent as per approval of EIC NOS. 12
48 MR Supplying and fixing recess mounted 3X20 watt COB based multiple zoom light make with all accessories (track , connector, suspension etc), directly on false ceiling including connection with 1.5 sq. mm FR PVC insulated copper conductor cable and earthing the body etc. as required. (Track light) Make- LD57-251-60-57-WG1 wipro, Philips, Orient, HPL or approved equivalent as per approval of EIC Each 45
Internal Panels : LT PANELS
49 Make of MCCB/MCB/ Metering- Lk, Legrand, Schneider, Siemens, ABB or approved equivalent as per approval of EIC
50 Note- Contractor have to submit all PANEL power wiring, control wiring , GA drawing, SLD, BOM, Type test certificate, Routine/Factory test report before approval of Panel
Panel maufacture will start only after approval from EIC
After intallation of Panel Panel Rating & Protection Detail, Installation and commissioning report, earthing detail, warranty and guarantee certicate etc need to be submited before final payment.
Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & indoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or equivalent as per approved make list and as direction by engneer in charge. PTTA Panel
1 nos. 320A 415V, Ics=36KA, 4P MCCB with MICRO PROCESSOR WITH O/C ,E/F ,S/C protection.
1 nos. 320A 415V, 4 POLE Contractor with Auxilary Cotact.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 320/5A.
1 Set of phase indicating lamp with MCB
1 Set of On,Off Trip lamp
1 set under voltage relay
1 set over voltage relay
1 nos. 250A 415V, Ics=36KA, 4P MCCB with MICRO PROCESSOR WITH O/C,E/F,S/C protection.
1 nos. 250A 415V, 4 POLE Contractor with Auxilary Cotact.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 250/5A.
1 Set of phase indicating lamp with MCB
1 Set of On,Off Trip lamp
1 set Reverse Power Relay
500A TPN Bus bar of aluminimum alloy.
160A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 2 N.o.
100A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 2 N.o.
63A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 5 N.o.
63A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 1 N.o + 63A 4P Contractor.for solar
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 63/5A. With control MCB
1 Set of On,Off lamp.
1 set Reverse Power Relay
40 A, FP,10KA, MCB – 1 N.o.
51 Total Main LT Panel NOS. 1
CAPACITOR INCOMER :-
1 No. Main Income 63A, TP+N, MCCB (25KA) with Thermal Magnetic Release for Over load, Short circuit Protection
One sets of 100A,TPN AL. Bus Bar with PVC Sleeve in sealed Bus Chamber.
METERING, INDICATION AND RELAY :
1 Nos. Digital Amp Meter with Current Transformer backed up with 6 Amps MCB
1 set Automatic Power Factor Correction Relay (8 Steps) with digital Power Factor Meter
One set of R/Y/B phase indication Lamp with control MCBs.
1 No. Auto / Manual Selector Switch
1 set of Aux. Contactors
1 No. timer for manual mode switching
1 Set of 1KVAR Capacitor bank 1X3Kvar Capacitor Duty Contactor and 10 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
1 Set of 2KVAR Capacitor bank 1X3Kvar Capacitor Duty Contactor and 10 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
1 Set of 3KVAR Capacitor bank 1X3Kvar Capacitor Duty Contactor and 10 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
2 Set of 5KVAR Capacitor bank 1X5Kvar Capacitor Duty Contactor and 15 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
1 Set of 10KVAR Capacitor bank 1X10Kvar Capacitor Duty Contactor and 32 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
52 Total Capacitor Panel Nos 1
LIGHTING & POWER PANEL
1 nos. 160A 415V, Ics=36KA, TP+N MCCB with TM Release WITH O/C,E/F,S/C protection.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 320/5A.
1 Set of phase indicating lamp with MCB
200A TPN Bus bar of aluminimum alloy.
63 A, FP,10KA, MCB – 7 N.o.
40 A, FP,10KA, MCB – 7 N.o.
53 Total Lighting & Power Panel Nos 1
1 nos. 100A 415V, Ics=25KA, TP+N MCCB with TM Release WITH O/C,E/F,S/C protection.
1 Set of phase indicating lamp with MCB
150A TPN Bus bar of aluminimum alloy.
40 A, FP,10KA, MCB – 6 N.o.
40 A, DP,10KA, MCB – 1 N.o.
32 A, DP,10KA, MCB – 1 N.o.
54 Total UPS Panel-1 Nos 1
1 nos. 63A 415V, Ics=25KA, TP+N MCCB with TM Release WITH O/C,E/F,S/C protection.
1 Set of phase indicating lamp with MCB
150A TPN Bus bar of aluminimum alloy.
40 A, FP,10KA, MCB – 2 N.o.
40 A, DP,10KA, MCB – 6 N.o.
55 Total UPS Panel-2 Nos 1
FEEDER PILLAR PANEL
40 A, FP,10KA, MCB – 1 N.o.
1 Set of phase indicating lamp with MCB
32 A, FP,10KA, MCB – 1 N.o.
32 A, DP,10KA, MCB – 1 N.o.
20 A, FP,10KA, MCB – 1 N.o.
40 A, FP,10KA, MCB – 1 N.o. as a incomer
1 Nos. 40A TP Contactor (AC 3 Duty with 230V Control Coil)
1 Nos. 24 hour double dial programmable time switch on Auto mode arrangement for Auto/Manual selection, Push Buttons, Indication lamps & Control fuses etc as required .
One (1) no. Mushroom head type emergency stop push button with under voltage release.
100A TPN Bus bar of aluminimum alloy.
10 A, SP,10KA, MCB – 4 N.o.
56 Total Feeder Pillar Panel Nos 1
PLUMBING & FIRE PANEL
1 No. 63A, TP+N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection
One set of 100 A TPN Alu. Bus Bar, 36kA with PVC Sleeve in sealed Powder Coated Bus Chamberas approved by architect and complete in all respect.
METERING AND INDICATION :
1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCB's (Eqv. To EM6436)
One set of R/Y/B phase indication Lamp with control MCBs.
1 Set of ON/OFF Indicating lamps .
1 Nos. 10A TP MCB (10KA) with DOL Starter for 3 KW
2 Nos. 10A TP MCB (10KA) with DOL Starter for 1.5 KW
1 Nos. 32A TP MCB (10KA) with Star Delta Starter 9.3 KW for Fire Booster Pump
2 Nos. 32A TP MCB (10KA)
57 Total Plumbing & Fire PANEL Nos 1
58 MR Supply of (Make- zyxel/Arista/HP/ CISCO) Ports Managed PoE+ Layer 2 Access Switch - L2 ACCESS SWITCH 28 Port along with necessary connectors, SFP modules, transceivers, configuartion of switch, etc in all manner ready to use. EACH 4
Contractor have to submit shop drawing of furniute on his own cost
Make - Godej, Durian, Vinar,HNI, Zura , SBDEE, Balance Art Construction, Fordela impex pvt ltd or approved equivalent as per approval of EIC
59 Cash counter Supply and placing reception table as per the picture. Table Size is 3200Lx2700D/1200Dx750ht/1050Ht. Working Table top 600mmD shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. Table modesty shall be made of 18mm thick prelaminated particle board. Table having 2nos of fixed drawer. 2+1 filling drawers shall be made out of 18 mm thick prelaminated particle board.Working Table side tops (L.H.S & R.H.S) depth is 450mm (D). Table having upper ledge shall be made of 25 mm thick prelaminated particle board and 200 mm wide. Gable end shall be made out of 25 mm thick prelaminated particle board with pvc edge banding tape, wire manager hole will be cut in the top for the wiremanagement. No 1
60 Reception Chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.It shall having pp fixed arms .It shall have tilt mechanism with the locking arrangement with gaslift. No 2
61 Seating couch Providing and placing 2 Seating couch as per photograph. Size of the couch is 1500Lx450Dx400Ht. The seating couch frame shall be made of seasoned wood and couch having fabric tapestry in the couch foam used high density 42-45mm/cm.Couch foam upholstery with the fabric tapestry. wooden gutka will be used in the bottom. No 4
62 Hexa Island display Counter Supply and placing island display as per the picture. Island Size is 1800Lx1500Dx1050Ht. Shelves and base shall be made of 18mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. Display central part shall be made of 18 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. No 3
Rectangle island display Counter Supply and placing Rectangle island display counter as per the picture.Counter Top, Sides and bottom shall be made of 18mm thick prelaminated particle board with pvc edge banding tape. Display counter having front side cover with the clear toughened glass. Counter having Toughned glass shelves for the clothes display.
63 Size 1500Lx600Dx1050Ht. EACH 8
64 Size 1350Lx600Dx1050Ht. EACH 4
65 Size 1200Lx600Dx1050Ht. EACH 4
66 Size 750Lx750Dx1050Ht. EACH 2
67 Director Room Cabin Table with Side unit Supply and placing Director table as per the picture. Table Size is 1800Lx750Dx750ht/1050Ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. Table understructure shall be made of 25/18mm thick prelaminated particle board. Table having side openable shutter storage with the 2+1 filling drawer.Table top support with the studs on the side unit top and gable end. Side unit 1800L(1050+750)X450DX750HT. Top shall be made of 25 mm thick prelaminated particle board and understucure shall be made of 18mm thick prelaminated particle board.Side unit having openable shutter + drawer. Flipper will be place on the top for wiremangement. Powder coated cable tray and wireriser will be provide below the side table top for the wiremanagement. EACH 1
68 Main Chair Providing and placing High back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the Leatherite. Back shall be upholstered with Leaterite . Chair having metal chrome base with the castors.Chair having metal fixed arms with pu pad.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 1
69 Visitor Chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the Leatherite. Back shall be upholstered with Leaterite . Chair having metal chrome base with the castors.Chair having metal fixed arms with pu pad.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 2
70 Cabin - 1 and 2 Table with Side unit Supply and placing officer table as per the picture. Table Size is 1500Lx600Dx750ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. wiremanager hole with cap will be provide on the table top for the wiremanagement . Table understructure shall be made of 18mm thick prelaminated particle board. Side unit Size :- 900Lx450Dxs750Ht. Side unit top and understructure shall be made of 25/18mm thick prelaminated particle board. Side unit having openable shutter with the 2eq drawerin upper side. Side unit having neccessary hardware. EACH 2
71 Main Chair Providing and placing High back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having PU adjustable arms with up and down system.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 2
72 visitor chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having PU adjustable arms with up and down system.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 4
73 Staff Area Table with Mobile Drawer Supply and placing Staff Table as per the picture. Table Size is 1350Lx600Dx750ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape.wire manager hole will be cut on the table top for the management. Table understructure shall be made of 18mm prelaminated paticle boardas per approved laminate. Mobile Drawer Size :- 400Lx450Dxs680Ht.Drawer unit shall be made of 18mm thick prelaminated particle board. Drawer having castors for the movement. EACH 6
74 Staff Chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having pp fixed arms .It shall have tilt mechanism with the locking arrangement with gaslift. EACH 5
Open Slotted angles Providing and placing the Ms slotted angles as per the pictutre. The Open slotted angle rack shall be made of MS slotted angle 2.0 mm thick.with the nut and bolts. The rack having 5 shelf storage unit, shelves are made of CRC Sheet 1 mm thick , simple stylish design comes with various colors options, easy to clean just wipe with clean dry cloth, easy to assemble & use. All metal part duly powder coated with the 50-60 microns
77 Meeting Table Supply and placing Meeting table as per the picture. Table Size is 2400Lx1200Dx750ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape.Table under structure shall be made out of 18mm thick prelaminated particle board. Table having metal flipper 400x120 mm for the wire management. table having metal cable tray below the table top for provion of the switch mounting tray with metal cable riser. EACH 1
78 chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having PU adjustable arms with up and down system.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 6
79 ELEMENT :Providing & making open display unit of any size(L)x 450(D) x2640/1200/900(HT) . The display rack top, sides , shelves and bottom shall be made of 18 mm thick prelaminated particle board as approved laminate shade design and colour.all exposed edges shall be covered with the pvc edge banding tape. Sizes are mentioned Below for saree section / display units for Male and Female sections :- Ground Floor 1. 8500(L)x450(D)x2640(Ht)=1 no 2. 7955(L)x450(D)x2640(Ht)= 1 no 3.5650(L)x450(D)x2640(Ht)= 1 no 4.3000(L)x450(D)x1200(Ht)= 1 no 5.1800(L)x450(D)x1200(Ht)=1 no First Floor 1. 9490(L)x450(D)x2640(Ht)= 1no 2.2250(L)x450(D)x2640(Ht)=1 no 3.4000(L)x450(D)x2640(Ht)=1 no 4.8750(L)x450(D)x2640(Ht)=1 no 5.2700(L)x450(D)x1200(Ht)=1 no 6.11310(L)x450(D)x900(Ht)=1 no sqm 155.3898
80 Show window - Providing and fixing plain lining with necessary screws/nuts & bolts/ nails,complete as per direction of Engineer-incharge 12mm thick commercial BWR GRADE BOARD / ply conforming to IS : 1328 BWR type with 1 MM THICK laminate finish as per specification table below show window having with glass etc. from either SUPA OR ADVANCE company). sqm 55
81 Mannequin full height 1800 mm nos. 10
82 Bed with Storage for Saree Section. Bed shall be made of 18 mm thick prelaminated particle board with the balancing laminate. Bed seat having 12 mm thick commercial ply. Bed having openable panels for storage purpose. sqm 15.3
Note for Furniture Work
Shop Drawings will be provided by the vendor and will be verified by the Architect/EIC.
All the works for installtion and fixing should be executed by the certified agency as approved by the Architect/EIC.
All items necessary for the completion of system but not mentioned in BOQ shall be included by the contractor without any extra cost.
ELEVATION - WORK
83 N.S providing, supplying and fixing of 6 mm tinted float glass, with visible light transmittal of minimum 28 %, with solar factor not less than 30 and with u value not less than 3.7 with allnecessary hardware and fittings as directed by Engineer in charge sqm 526.3075
84 N.S. Extra for openable side / 6 mm tinted float glass top hung vision glass panels including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. sqm 52.63075
85 N.S. Providing and applying Duco paint finish on M.S. surface including cleaning, sandpapering, and preparing the surface; applying two coats of zinc chromate/epoxy primer and two coats of Duco paint of approved shade and make (e.g. Asian / Nerolac / Equivalent), applied by spray method to achieve a smooth and uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. sqm 550
i) Shop Drawings will be provided by the vendor and will be verified by the Architect/ EIC.
ii) All the works for installtion and fixing should be executed by the certified agency as approved by the Architect/EIC
iii) All items necessary for the completion of system but not mentioned in BOQ shall be included by the contractor in above cost.
INFRASTRUCTURE DEVELOPMENT AUTHORITY
(A GOVERNMENT OF BIHAR UNDERTAKING)
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Whatsapp Enabled Mobile Number
NIT - 10/TEN/IDA/26
Sl no. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.) 75,898,919.67
2 Total Non-Schedule Amount (Rs.) To be Quoted!
TOTAL AMOUNT Rs. 93,009,419.00
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
S.No. Particular Amount
1 Schedule Items 75,898,919.67
2 Non-Schedule Items
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
SCHEDULED ITEMS
S.No. BSR-01-01-22 DESCRIPTION OF ITEMS UNIT QTY RATE AMOUNT
1 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. cum 778.94 360.70 280,963.30
2 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m cum 584.20 123.90 72,382.91
3 2.27 Extra for every additional lift of 1.5 m or part thereof in :
2.27.1 Ali kinds of soil. cum 143.96 49.40 7,111.68
4 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. cum 120.00 287.30 34,476.00
5 2.29 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m
6 2.37. Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent (including the cost of chemical emulsion)
2.37.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor.
2.37.3.1 With Chlorpyriphos EC 20% with 1% concentration sqm 333.00 241.20 80,319.60
7 4.1 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.
4.1.3 1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cum 74.80 3,998.10 299,057.88
8 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). cum 45.96 2,975.20 136,746.02
9 4.11 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). sqm 75.00 245.60 18,420.00
10 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. sqm 75.00 436.60 32,745.00
11 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, sqm 309.00 283.30 87,539.70
REINFORCED CEMENT CONCRETE
12 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - all work upto Plinth level
5.1.1 1:1:2(1 Cement :1 coarse sand :2 graded stone aggregate 20mm Nominal size) M-25 cum 90.40 5,961.90 538,982.23
13 5.2 Reinforced cement concrete work in wall ( any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, adutments, posts and struts, etc. upto floor five level exculding cost of centring, shuttering, finishing and reinforcement
5.2.1 1:1:2 (1: Cement :1 coarses sand :2 graded stone aggregate 20mm nominal size) M-25 cum 195.82 6,943.50 1,359,683.37
5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
14 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. sqm 349.03 211.60 73,855.17
15 5.9.2 Walls (any thickness) including attached pilasters butteresses, plinth and string courses etc. sqm 1,025.46 375.10 384,648.92
16 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 1,518.88 437.50 664,507.90
17 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 925.19 404.70 374,423.14
18 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 908.85 494.40 449,334.69
19 5.9.7 Stairs, (excluding landings) except spiral-staircases. sqm 237.44 439.90 104,449.86
5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
20 5.22.7.A Thermo-Mechanically Treated bars. TMTC-500-8MM dia kg 29,518.15 94.50 2,789,465.23
21 5.22.7.B Thermo-Mechanically Treated bars. TMTC-500-10MM dia kg 35,421.78 92.60 3,280,056.89
22 5.22.7.C Thermo-Mechanically Treated bars. TMTC-500-12MM dia Kg 24645.6878462187 90.80 2,237,828.46
23 5.22.7.D Thermo-Mechanically Treated bars. TMTC-500-16,20,25 MM dia Kg 108,233.22 91.70 9,924,986.16
5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but exculding the cost of centering, shuttering, finishing and including retard setting of concrete, improve worksability without impairing strength and mixtures in recommended proportions as per IS: 9103 to accelerate, rainforcement, durability as per direction of Engineer-in charge Note:- Cement content considered in this item is @330 kg/ cum. Execess or less cement used as per design mix is payable or recoverable separately.
5.33.1 All works upto plinth level
24 5.33.1.1 Concrete of M-25 grade with minimum cement content of 330 kg/cum cum 179.07 5,063.40 906,709.11
5.33.2 All work above plinth upto floor V level
25 5.33.2.1 Concrete of M-25 grade with minimum cement content of 330 kg/cum cum 370.32 5,863.20 2,171,258.80
5.33B Add or deduct for providing richer or leaner mixes respectively at all floor levels.
26 5.33B.2 Providing M-30 grade R.C.C. instead of M-25 grade R.C.C.(266.10-194.20) cum 549.39 225.40 123,832.72
27 20.2A. Boring, providing and installing bored cast-in-situ reinforced of grade M-25 of specified diameter and length below the pile cap, to carry a safe cement concrete piles working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.(By Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).
28 20.3A.2 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem -A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead ineluding all lifts , all complete as per approved design and direction of (E/l) Each 113.00 190.20 21,492.60
29 20.6 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loadingplatform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
20.6.3 Group of two or more piles upto 50 tonne capacity
20.6.3.1 Initial test per test 2.00 66,227.90 132,455.80
30 6.1A Brick work with bricks of class designation 100A in foundations and plinth in : cum 294.51 5,017.90 1,477,821.73
31 6.1.12/1 Cement mortar 1 .:4 (1 cement: 4 coarse sand )
6.3A Extra for Brick work in superstructure above plinth level upto floor V cum cum 216.36 842.20 182,218.39
32 6.18A Half brick masonry with bricks of class designation 100A in foundations and plinth in :
6.18.3A Cement mortar 1:3 (1 cement: 3 coarse sand) sqm 142.56 621.50 88,601.04
33 6.19A Extra for half Brick masonry in superstructure above pinth level upto floor V level. sqm 142.56 89.70 12,787.63
34 6.21A Extra for providing and placing in position 2 Nos, 6 mm dia MS bars at every third course of half brick masonry (with F. P.S.bricks) sqm 142.56 113.60 16,194.82
35 6.47 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). cum 207.69 5,350.00 1,111,141.50
36 6.38 Providing and laying Autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand).The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. cum 11.95 6,233.20 74,499.21
37 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :
38 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :
39 9.6.2 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade-1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade 1, Type - II marked sqm 1.00 2,640.70 2,640.70
40 9.7 Providing and fixing panelling or panelling and glazing in panelled of panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates tobe measured) panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick
9.7.5.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination sqm 1.00 1,314.90 1,314.90
41 9.9 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including black enamelled ISI marked M.S butt hinges with necessary screws.
9.9.1 Second class teak wood
42 9.20 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 40.80 2,845.60 116,100.48
43 9.20. Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
9.21.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 18.00 1,641.50 29,547.00
44 9.40 Providing and fixing wooden molded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc . Complete
9.40.1 2nd Class teak wood
46 9.45 Providing and fixing teak wood lipping of size 25*3mm rmt 95.00 33.90 3,220.50
47 9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete
48 9.76 Providing and fixing bright finished brass 100mm mortice latch and lock with 6 lever handles with necessary screws etc complete (best make of approved quality) each 10.00 639.40 6,394.00
49 9.77 Providing and fixing bright finished brass 100mm moritce latch with one dead bolt and a pair of lever handles with necessay screws etc. complete each 5.00 519.00 2,595.00
50 9.82 Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. complete each 10.00 108.10 1,081.00
51 9.83 Providing and fixing IS: 3564 bright finished brass hydraulic door closer (best make of approved quality) with necessary accessories and screws etc. complete each 5.00 979.50 4,897.50
52 9.85 Providing and dixing bright finished brass casement window fastener with necessary screws etc. complete each 132.00 71.30 9,411.60
53 9.105 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both e
9.105.3 66 mm overall thickness Partition with 8 mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq cm, Bending Strength 100 kg/ sq cm sqm 10.00 1,488.60 14,886.00
9.1 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B), using 4 mm thick float glass panes for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished oF required size with necessary screws, all as per directions of Engineer-in-charge.
54 9.10.1 30 mm thick shutters sqm 10.00 2,506.90 25,069.00
9.7.7 Float glass panes.
56 9.120 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
9.120.2 30 mm thick pre laminated PVC door shutters sqm 5.00 2,293.40 11,467.00
57 9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:
58 9.24 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):
9.24.1 Rectangular or square sqm 10.00 173.90 1,739.00
59 9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete:
60 9.127 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
61 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid for separately). sqm 22.00 6,445.00 141,790.00
62 10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position andapplying a priming coat of approved steel primer using structural steel, etc. as required.
10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. Gates & similar works. KG 1435.00 114.60 164,451.00
63 10.36 Providing and fixing stainless steel (grade 304) railing made of hollow tubes, channels, plates etc, including welding, grainding, buffing, polishing and making curvature (wherever required)and fitting the same with necessary stainles steel nuts and bolts complete. i/c fixing the railing with necessary accessories & stailess steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitalbe arrangement as per approval of Engineer-in-charge ( for payment purpose only weight of stailess steel member shall be considered excluding fixing accessores such as nuts, bolts, fasteners etc.) kg 1750.00 546.80 956,900.00
64 10.42 Providing and fixing bolts including nuts and washers and Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. KG 1180.00 105.30 124,254.00
65 10.43 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) Metre 118.00 272.60 32,166.80
66 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias andCVsimilar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,includingrubbing, curing, moulding, nosing and polishing to edges to give etc. complete at all levels.
8.2.2.1 Area of slab upto 0.50 sqm sqm 15.72 4,242.90 66,698.39
67 8.12 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over20mm(avearage) thick base of cement mortar 1:4(1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
a Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. sqm 247.15 2,147.70 530,804.06
68 8.3 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
69 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
70 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. rmt 5.00 82.90 414.50
71 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sqm 342.72 795.00 272,462.40
72 11.41 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
73 11.52 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
a. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. sqm 5.00 5,908.40 29,542.00
74 12.55 X Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. Sqm 385.00 1,101.60 424,116.00
75 12.52X Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52x.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. sqm 1145.05 1,004.20 1,149,859.21
#REF! 12.82 Providing and fixing at all height false ceiling of 12.5 mm thick -tapered edge gypsum board conforming to IS : 2095 including -providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanized in accordance with zinc coating 120gm/sqm as per IS : 277 and consisting of angle cleats of size 25 mm wide x 16 mm thick with flanges of 22 mm and 27 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bots to the angle hangers of 25x10x0.5 mm of required length, and other end of angle hangerbeing fixed with nut and bots to rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450 mm centre to centre shall be be fixed in a direction perpendicular to G. I. channel with connecting clips made out of 2.64 mm dia x 230 mm long G. I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long . the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long dirve-all screws @ 230 mm interval including jointing and fixing to a flush of tapered and square edges of the gypsum board with recommended filler., paper tapes, finisher and two coats of primer suitable for gypsum board as per manufactures specification and also including the coat cutouts made with frame of perimeter channels suitably fixed all complete as per- drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting. sqm 5.00 738.30 3,691.50
76 12.52X Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52x.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. sqm 45.18 1,348.40 60,920.71
77 12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete each 5.00 189.40 947.00
78 13.11 12mm Cement Plaster of mix:
79 13.78A Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such asbare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. sqm 770.00 256.50 197,505.00
80 13.12 15mm cement plaster on rough side of single or half brick all of mix:
81 13.24 6mm cement plaster ot ceilig of mix:
82 13.40A Providing and applying plaster of pairs putty of 2 mm thickness over plastered sufrace to prepare the surface even and smooth complete sqm 4759.67 127.90 608,761.79
83 13.78 Applying one coat of cement primer of approved brand and manufacture on wall surface:
13.78.2 Distemper primer sqm 4760.00 38.70 184,212.00
84 13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade
13.92.1 Two or more coats on new work sqm 4760.00 86.40 411,264.00
85 13.101 French spirit polishing:
13.101.1 13.101.1 Two or more coats on works including a coat of wood filler. sqm 85.00 215.80 18,343.00
86 13.104 Polishing on wood work with ready made wax polish of approved brand and manufacture:
88 22.1 Providing and laying integral cement based treatment for water . proofing on horizontal surfaces at all levels as directed by Engineer-in-charge andB consisting of: 1) 1st layer of 20 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement:3 coarse sand) mixed with water proofing compund conforming to IS: 12645 in the recommnded proportion. Joints sealed and grouted with cement slurry mixed with water proofing compound conforming to IS: 12645 in proportions recommended by the manufacturer. II) 2nd'c!ass layer of 25 mm thick cement mortar 1:3 (1 cement:3 coarse sand) mixed with water proofing compound in recommended proportions. Ill) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreadidng @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
22.1.1 Using rough kota sotne. sqm 33.95 1,396.30 47,404.39
89 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge
22.2.1 Using rough kota stone sqm 77.89 1,752.40 136,494.44
90 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions. (ii) II nd course of 20 mm cement plaster 1:3 (1: cement :3 coarse sand) mixed with water proofing compound in recommended proportion. (iii) IIIrd course of applying blown or/ residual bitumen aplied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet ( Overlaps at joints of PVC shet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) sqm 409.20 480.60 196,661.52
91 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. Sqm 415.00 90.70 37,640.50
16.3 Supplying and stacking at site
92 16.3.1 90 mm to 45 mm size stone aggregate ( WBM) cum 62.25 841.00 52,352.25
93 16.3.6 Stone screening 13.2 mm nominal size (Type A) (GSB ) cum 62.25 800.10 49,806.23
95 16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density cum 553.50 487.00 269,554.50
96 11.79 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
11.79.1 (a) 80 mm thick c.c. paver block of M-35 grade with approved colour design and pattern. sqm 415.00 956.40 396,906.00
97 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). cum 15.93 7,998.80 127,420.88
98 CARRIAGE OF MATERIALS
99 DIFFERENCE IN COST OF MATERIALS
Plumbing & Fire Fighting Work
BSR 2022 BSR 2022. ITEMS:-
100 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast P or S trap, 10 Litre low level P.V.C. flushing cistern with manually controlled device(handle lever) conforming to IS:7231, with all fittings & fixtures complete including cutting and making good the walls and floors wherever required.
17.1.1. White vitreous chinaOrissa pattern W.C. pan of size 580x480mm with integral type foot rests. Each 3.00 4,470.90 13,412.70
101 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 9.00 5,504.30 49,538.70
102 17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern with fittings,standard size C.P.brass flush pipe,spreaders with unions & clamps(all in CP brass)including painting of fittings, cutting and making good the walls and floors where required.
17.5.1 a) Single half stall urinal basin with 5litre automatic flushing cistern. Each 5.00 6,469.00 32,345.00
103 17.7 Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required.
17.7.3 White vitreous china wash basin size 550 mm x 400 mm with single 15mm CP brass pillar tap. Each 9.00 2,530.30 22,772.70
104 17.10 Providing and fixing Stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittingsand brackets, cutting and making good the walls whereve required.
17.10.1 Kitchen sink with drain board
17.10.1.1 510 X 1040 mm bowl depth 250mm Each 0.00 5,231.50
105 17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tubeupto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. Each 9.00 299.40 2,694.60
106 17.28 Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete .
107 17.31 Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 9.00 1,068.50 9,616.50
108 17.33 Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. Each 1.00 713.30 713.30
109 17.34 Providing and fixing toilet paper holder.
110 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
17.70.1 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms Each 14.00 325.10 4,551.40
111 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.minimum water seal, weighing not less than 263 gms Each 8.00 146.30 1,170.40
112 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms Each 9.00 204.70 1,842.30
18.7 Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. .
Internal Work - Exposed on Wall
113 18.7.1 15 mm outer dia pipes. Metre 0.00 172.00
114 18.7.2 20 mm outer dia pipes. Metre 16.10 233.90 3,765.79
115 18.7.3 25 mm outer dia pipes. Metre 20.70 317.30 6,568.11
116 18.7.4 32 mm outer dia pipes. Metre 9.20 395.20 3,635.84
117 18.7.5 40 mm outer dia pipes. Metre 78.20 538.40 42,102.88
118 18.7.6 50 mm outer dia pipes. Metre 62.10 791.00 49,121.10
18.8 Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge.
Concealed work oncluding cutting chases and making good the walls etc.
119 18.8.1 15 mm outer dia pipes. Metre 1.00 278.20 278.20
120 18.8.2 20 mm outer dia pipes. Metre 64.40 350.80 22,591.52
121 18.8.3 25 mm outer dia pipes. Metre 9.20 463.10 4,260.52
122 18.8.4 32 mm outer dia pipes. Metre 0.00 549.80
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This including jointing of pipes & fittings with one step CPVC solvent cement trenching refilling& testing of joints complete as per direction of engineer in charge.
123 18.9.4 32 mm outer dia pipes. Metre 0.00 359.10
124 18.9.5 40 mm outer dia pipes. Metre 0.00 477.60
125 18.9.6 50 mm outer dia pipes. Metre 0.00 730.30
126 18.12 Providing and fixing GI complete with GI fittings including trenching and refilling etc.
18.12.6 50 mm dia nominal bore. Metre 30.00 572.60 17,178.00
18.16 Providing and fixing brass stop cock of approved quality complete.
127 18.16.1 15 mm nominal bore Each 0.00 303.80
128 18.16.2 20 mm nominal bore Each 5.00 328.00 1,640.00
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
129 18.18.2 20 mm nominal bore Each 2.00 397.40 794.80
130 18.18.3 25 mm nominal bore Each 9.00 399.20 3,592.80
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
131 18.17.1 25 mm dia nominal bore Each 9.00 532.30 4,790.70
132 18.17.2 32 mm dia nominal bore Each 2.00 589.90 1,179.80
133 18.17.3 40 mm dia nominal bore Each 1.00 707.30 707.30
134 18.17.4 50 mm dia nominal bore Each 2.00 878.20 1,756.40
135 1.18.48 Providing and placing on terrace (at all floor levels) Polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement amd making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Litre 1,000.00 9.70 9,700.00
136 18.49 Providing and fixing C.P.brass bib cock of approved quality conforming to IS : 8931. Each 1.00 434.20 434.20
137 18.51 Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms.
18.51.1 15 mm nominal bore. Each 1.00 708.40 708.40
138 18.53 Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931 a) 15 mm nominal bore
18.53.1 15 mm nominal bore Each 18.00 500.40 9,007.20
DRAINAGE- EXTERNAL
139 19.4 Providing and fixing square-mouth S.W. gully trap Class SP-1 complete with C.I. grating brick masonry chamber with grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
19.4.2 150x100mm size P type
19.4.2.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 2.00 1,908.90 3,817.80
19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
142 19.2.4 250 mm dia DWC pipe mtr 0.00 666.50
19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
146 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :
19.7.1 Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg).
19.7.1.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 5.00 7,914.70 39,573.50
147 19.8 Extra for depth for manholes
19.8.2 Size 120x90 cm
19.8.2.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Mtrs 0.00 6,776.30
148 19.27 Providing and constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design.
19.27.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 6.00 3,743.70 22,462.20
19.30 Providing and constructing brick masonry chamber for undergroundCI inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
149 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
150 19.30.1 With common burnt clay F.P.S (non - modular) bricks of class designation 7.5 Each 1.00 4,266.80 4,266.80
RAIN WATER HARVESTING SYSTEM
151 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
24.1.2 Rocky strata including Boulders
152 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.2 150 mm nominal size dia meter 50.00 673.50 33,675.00
153 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 10.00 1,118.90 11,189.00
154 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 10.00 1,195.60 11,956.00
155 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. cum 10.00 1,195.60 11,956.00
TUBE WELL-Boring Depth 100mtr Consider
156 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level
24.1.1 All types of soil
157 24.1.2 Rocky strata including Boulders
158 24.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level
24.2.1 Rocky strata including Boulders
159 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
24.3.2 150 mm nominal size dia metre 70 660.10 46,207.00
160 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.2 150 mm nominal size dia metre 30 673.50 20,205.00
161 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,188.90 4,755.60
162 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,195.60 4,782.40
163 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum 4 1,195.60 4,782.40
164 24.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Cum 4 1,343.20 5,372.80
165 24.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. each 2 1,213.20 2,426.40
24.1 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
166 24.10.2 150 mm nominal size dia having minimum wall thickness 5.00 mm Metre 70 1,408.10 98,567.00
167 24.10.3 200 mm nominal size dia having minimum wall thickness 5.40 mm Metre 75 2,003.70 150,277.50
168 24.11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
24.11.2 150 mm nominal size dia metre 100 1,727.20 172,720.00
169 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hour 12 916.80 11,001.60
170 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
171 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete
172 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
173 18.31.1 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
18.31.1 100 mm diameter
18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
174 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 7,210.60 7,210.60
175 7183 Supply of Bentonite kg 500 2.80 1,400.00
176 ,026 Hiring charges of Bentonite Pump Day 4 3,000.00 12,000.00
Rain Water Harvesting Bore Well-Depth Consider 100mtr
24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level
24.1.1 All types of soil
24.1.2 Rocky strata including Boulders
179 24.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level
24.2.1 Rocky strata including Boulders
180 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
24.3.2 150 mm nominal size dia metre 70 660.10 46,207.00
181 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.2 150 mm nominal size dia metre 30 673.50 20,205.00
182 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,188.90 4,755.60
183 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 4 1,195.60 4,782.40
184 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum 4 1,195.60 4,782.40
185 24.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Cum 4 1,343.20 5,372.80
186 24.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. each 2 1,213.20 2,426.40
24.1 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
187 24.10.2 150 mm nominal size dia having minimum wall thickness 5.00 mm Metre 70 1,408.10 98,567.00
188 24.10.3 200 mm nominal size dia having minimum wall thickness 5.40 mm Metre 75 2,003.70 150,277.50
189 24.11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
24.11.2 150 mm nominal size dia metre 100 1,727.20 172,720.00
190 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hour 12 916.80 11,001.60
191 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
192 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete
193 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
194 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 7,210.60 7,210.60
FIRE FIGHTING WORKS
BSR 2022 CHAPTER - 27
Note- Following work is included in the scope of contractor 1) Contractor have to submit shop drawing of Fire Fighting work own cost before execution of work 2) All material test certicate should be submitted 3) All material make model and sample should be get approved from EIC before execution of work 4) Apply and getting Fire Audit report own cost is in contractor scope. contractor have to make arrangement to get tested of all fire fighting work and paper from fire deparment . After successful audit of Fire work final bill will be paid for fire fighiting work
Supplying, installation, testing and commissioning ofelectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
PIPES & ACCESSORIES
7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
199 9.1 Single headed Gunmetal Set 4 7,245.00 28,980.00
11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
203 13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete required. Each 4 1,236.00 4,944.00
14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
15 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
207 16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
208 17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required; -20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 -20 mm nominal internal dia gun metal globe valve & nozzle. -Drum and brackets for fixing the equipmets on wall. -Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
209 18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
210 19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
211 20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Nos 1 17,707.00 17,707.00
212 22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Nos 5 1,442.00 7,210.00
DISMANTLING AND DEMOLISHING
213 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. CUM 160 1,411.20 225,792.00
214 15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
15.7.4 In cement mortar CUM 240 823.70 197,688.00
215 15.25 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. SQM 1430 106.70 152,581.00
Sub Total` 49,192,662.79
GST ADD GST 5.36% ON ITEM BSR-2022 5.36% 2,636,726.73
Civil Work Total 51,829,389.52
ELECTRICAL Work
Make - All SOR material will be used as per BCD approved make as per approval of Engineer Incharge
216 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required.
217 1.4 Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, , modular plate, suitable size G.l. box etc as required. Point 8 1,248.00 9,984.00
218 1.5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr 1200 309.00 370,800.00
1.6 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr 0 523.00
1.7 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.
222 1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Mtr 25 557.00 13,925.00
224 1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire Mtr 50 660.00 33,000.00
227 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reeessed PVC conduit as required.
1.16 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit
1.17 TV cable in existing conduiting: Supply & drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in existing surface/ recessed steel/ PVC conduit as required. Mtrs. 0 42.00
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
234 1.24.4 3 pin 5/6 A socket outlet Each 15 112.00 1,680.00
235 1.24.5 6 pin 15/16 A socket outlet Each 7 183.00 1,281.00
236 1.24.6 Telephone socket outlet Each 2 131.00 262.00
1.24.7 TV socket outlet Each 0 131.00
237 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 33 358.00 11,814.00
238 1.26 Supplying and fixing of modular Blanking plate on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd. Each 15 34.00 510.00
239 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
244 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Each 30 414.00 12,420.00
245 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Each 66 531.00 35,046.00
246 1.33 Supplying and fixing 2 pin, 5/6 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. Each 234 64.00 14,976.00
247 1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required. Each 20 80.00 1,600.00
1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Each 0 134.00
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Each 0 135.00
248 8.14 Supply and fixing extra down rod for ceiling fan of 1 metre length G.l. pipe, 15 mm dia, heavy guage including painting etc. as required. Each 33 409.00 13,497.00
1.5 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1.50.1 Upto 450 mm sweep Each 0 296.00
1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 0 129.00
249 1.55 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos.3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. Each 10 632.00 6,320.00
250 1.59 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
251 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
2.8 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.5 6 way , Double door Each 0 2,197.00
252 2.8.6 8 way , Double door Each 6 2,591.00 15,546.00
253 2.8.7 12 way , Double door Each 1 2,314.00 2,314.00
2.9 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way (4 + 12), Double door Each 4,184.00
2.1 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2.10.1 4 way (4 + 12), Double door Each 0 7,857.00
2.10.3 12 way (4 + 36), Double door Each 0 13,572.00
2.12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.15 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.16 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.17 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.18 Supplying & Fixing of following rating four pole (three phase and neutral) 415 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 30 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
262 2.27 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. Each 39 1,162.00 45,318.00
2.19 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 0 1,513.00
263 2.26 Supplying and fixing 30 A/32A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A/32A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 5 4,637.00 23,185.00
264 2.2 Providing and fixing M.V. danger notice plate of 200x150mm ,made of mild steel at least 2mm thick ,vitreous enameled white on both sides ,and with inscription in single red colour on front side as required. Each 15 214.00 3,210.00
DSR 4.1 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
265 4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness RM 75 686.00 51,450.00
266 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness RM 100 866.00 86,600.00
DSR 4.2 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
267 4.2.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,105.00
268 4.2.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,544.00
DSR 4.3 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
4.3.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,281.00
4.3.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,826.00
DSR 4.4 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
4.4.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 0 1,498.00
4.4.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 0 2,110.00
269 8.15 Supply and installation of regular/standard model A.C.\ ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 12 2,482.00 29,784.00
270 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required Each 10 3,670.00 36,700.00
Networking- scheduled items
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
272 1.58 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1.58.1 1 run of cable Metre 250 52.00 13,000.00
LIGHTING FIXTURES
5.7 Supplying and fixing recess mounted following types led downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
275 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required
276 5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required . NOS. 102 2,663.00 271,626.00
277 5.3 Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminum housing and complete with integrated electronic driver etc directly on wall ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. (For Non-residential building) NOS. 25 762.00 19,050.00
278 5.1 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. NOS. 15 1,275.00 19,125.00
279 5.13 Supplying and fixing post top / gate light (width 250/ 300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) NOS. 15 1,399.00 20,985.00
280 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.18 Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
282 6.1.7 20 watt LED lamp Each 15 267.00 4,005.00
283 6.1.4 9/10 watt LED lamp Each 5 161.00 805.00
284 BCD SOR-23 5.2 Supplying and fixing 2'X9 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Supplying and fixing 4'X20 watt LED batten each 9 492.00 4,428.00
285 MP-23 31.17 Supplying, fixing & testing of approved make flexible LED strip comprising of 60 LED per meter W/O driver for direct mounting complete with all accessories including connection lead, fixing, connection as required. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
31.17.1 + GST Flexible LED strip 24Watt/25Watt - 5 M indoor cove light W/O Driver IP 20 -33 Each 28 1,458.48 40,837.44
286 MP-23 31.18 Supplying, fixing & testing of approved make Power supply for LED strip
31.18.1 + GST Power supply 25Watt/30Watt for LED strip IP25/IP33 Each 28 628.94 17,610.32
FIRE ALARM SYSTEM ( DSR Items)
INTELLIGENT FIRE ALARM SYSTEM
(Make - Honeywell, Siemens, Notifier, Bosch as per approval of EIC)
287 17.2.1 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
17.2.1.2 Two Loop Panel. Each 1 239,225.00 239,225.00
288 17.2.3 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. Each 1 108,688.00 108,688.00
289 17.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Each 51 2,858.00 145,758.00
290 17.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Each 10 276.00 2,760.00
291 17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Nos 5 3,871.00 19,355.00
292 17.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. Nos 5 3,506.00 17,530.00
17.2.17 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Nos 0 5,740.00
17.2.19 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Nos 0 1,600.00
293 17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required Meter 765 173.00 132,345.00
DSR-25 10 KVA UPS
294 26.1.4 Supplying of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input,Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance,Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt / VA, Amp and Voltage power parameters etc.
UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc Make- Vertiv, APC, Hitachi, Numeric or approved equivalent as per approval of EIC Nos 1 168,506.00 168,506.00
Make- Bosch, Ahuja, Honeywell or approved equivalent as per approval of EIC.
295 28.3.1 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. Each 1 132,115.00 132,115.00
296 28.3.2 Supplying, installation, testing & commissioning of 3/6W ceiling speaker complete as required Nos 57 1,025.00 58,425.00
28.3.3 Supplying, installation, testing & commissioning of 3/6W metal box ceiling/wall speakers complete as required. Nos 0 1,891.00
28.3.9 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required Nos 0 85,450.00
297 39.23.3 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8 mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 15U rack Nos 1 13,330.00 13,330.00
298 MP 23 53.3.5 + GST Supply, installation, testing and commissioning of 480W power amplifier with 100,70V speaker OP, combination XLR/RCA line in line out connectors. Speaker OP short circuit protection.(with require mounting arrangement) Each 1 63,537.10 63,537.10
299 DSR-25 28.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm mtr 140 61.00 8,540.00
301 Make- Hikvision, CP Plus, Honeywell or approved equivalent as per approval of EIC
302 39.11 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D (Make- D-link /Digsol/ Zyxel /HP) Nos 16 5,278.00 84,448.00
303 MP 23 54.28.1 + GST Supply, installation testing and commissioning of 24 port PoE switch with 4 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP Cat. 5, Cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 56 GBPS, maximum 64 bytes packet forwarding rate, 41.7mbps, Ports 1 to 24 compliant with 802.3 at (Make- D-link / Zyxel /HP) Nos 1 41,200.00 41,200.00
DSR 25 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent )
304 39.12.1 Copper Patch Cords of length 1m (3ft) Nos 250 151.00 37,750.00
DSR 25 40.5 Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :- 1)Type of Camera: Dome Camera 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night. 9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
DSR 25 40.5 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device,
DSR 25 40.5 19) Edge Analytics : Tripwire, Intrusion, Motion Detection 20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF
DSR 25 40.5 25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 27) Ethernet: 1 RJ 45 10/100 Ethernet port 28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 30) Enclosure: IP67 weather proof, IK10 31) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
305 40.5.1 4MP/3MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera. Nos 20 6,800.00 136,000.00
DSR 25 40.6 Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc :- 1) Type of Camera: Bullet Camera 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Lens Type & Focus: as given below. 9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 Mtrs for colour view in night. 10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
DSR 25 40.6 11) Wide Dynamic Range: WDR (120dB or more) 12) Digital Noise Reduction: DNR (2D/3D) On/Off 13) Streaming: Triple streaming, configurable 14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 16) Profile Management: User configuration import, export 17) Security: User Authentication, Digital Water Marking 18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 19) Recording Management: Format SD, overwrite, storage management, video to NAS device
DSR 25 40.6 20) Edge Analytics: Tripwire, Intrusion, Motion Detection 21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 22) Alarm Support: It should have 1/1 Alarm In/ Out Port 23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/ AAC/ G.726 audio compreesion 24) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 25) System Capability: ONVIF 26) VMS: Camera shall support open source VMS 27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, , video encryption, IP/MAC filtering, HTTPS, trusted upgrade.
DSR 25 40.6 28) Ethernet: 1 RJ 45 10/100 Ethernet port 29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 30) Power Requirement: 12VDC/24V DC/PoE (802.3af)/ePoE 31) Enclosure: IP67 weather proof, IK10 32) Operating Condition: Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 33) IR life: 40000 hours or higher 34) Video Bit rate: 32 KBPS - 8 MBPS or better 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
306 40.6.1 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) outdoor bullet Camera eACH 5 12,525.00 62,625.00
307 40.11.2 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1 /4/ 8/9/16/25 /36/64, 2nd screen: 1/4/8/9/16 Nos 2 82,600.00 165,200.00
308 40.12.2 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 6TB (Terabytes) Nos 2 16,376.00 32,752.00
309 42.4.3 Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. 55 inch or larger (Make- LG, Samsung, Dell, HP or approved equivalent) Nos 1 82,057.00 82,057.00
310 39.23.3 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 15U rack (Make- D link, Digisol, Molex or approved equivalent) Nos 1 13,330.00 13,330.00
MP 23 38.14 Supply, installation testing and commissioning of High-Speed HDMI corrosion-resistant connector & braided cable, Supports Ethernet, 3D, 4K video, computers and other HDMI-enabled devices Black as required to complete the job as mentioned below :- (Make- Kramer, Honeywell, Bluerigger, Belkin or approved equivalent)
311 38.14.2 + GST 2 Metre, HDMI cord Each 1 2,125.18 2,125.18
312 38.14.5 + GST 15 Metre, HDMI cord Each 1 12,628.36 12,628.36
313 1.58.1 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent ) mtr 2000 52.00 104,000.00
314 1.21.2 Supplying and fixing of following sizes of medium class 25 PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. mtr 2000 120.00 240,000.00
315 39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U rack (Make- D link, Digisol, Molex or approved equivalent) Nos 5 6,939.00 34,695.00
316 39.23.2 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 9U rack (Make- D link, Digisol, Molex or approved equivalent) Nos 1 8,960.00 8,960.00
317 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent ) Each 5 5,278.00 26,390.00
318 DSR 25 39.7 Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for Low Density use having features and specifications etc. as mentioned here under - Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal /Enterprise , WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Should also work as Standalone and must be Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. (Make- zyxel/Arista/HP/ CISCO) EACH 8 22,739.00 181,912.00
319 DSR-25 39.14 Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. (Make- D link, Digisol, Tp Link,Legrand or approved equivalent ) EACH 66 212.00 13,992.00
Earthing and Cabling
SUB HEAD A - DSR ITEMS
EARTHING AND LIGHTING ARRESTER
320 BSR 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. set 12 6,884.00 82,608.00
321 BSR 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. set 6 13,721.00 82,326.00
322 BSR 3.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) mtr 80 1,026.00 82,080.00
323 BSR 3.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) mtr 150 133.00 19,950.00
324 BSR 3.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. mtr 10 1,180.00 11,800.00
325 BSR 3.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. mtr 20 195.00 3,900.00
326 BSR 3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. mtr 100 53.00 5,300.00
327 BSR 4.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Each 10 416.00 4,160.00
328 BSR 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) mtr 150 102.00 15,300.00
329 BSR 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) mtr 140 145.00 20,300.00
330 BSR 4.11 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. Each 6 274.00 1,644.00
331 BSR 4.13 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Mtr 30 1,530.00 45,900.00
DSR 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
333 7.1.2 Above 35 sq. mm and upto 95 sq. mm Mtr 0 405.00
334 7.1.3 Above 95 sq. mm and upto 185 sq. mm Mtr 15 422.00 6,330.00
DSR 7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
336 7.2.2 Above 35 sq. mm and upto 95 sq. mm Mtr 15 286.00 4,290.00
337 7.2.3 Above 95 sq. mm and upto 185 sq. mm Mtr 5 304.00 1,520.00
DSR 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required.
339 7.5.2 Above 35 sq. mm and upto 95 sq. mm Mtr 10 57.00 570.00
340 7.5.3 Above 95 sq. mm and upto 185 sq. mm Mtr 5 77.00 385.00
DSR 7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface and overhead as required.
341 7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Mtr 150 55.00 8,250.00
342 7.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Mtr 30 130.00 3,900.00
7.7.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Mtr 0 153.00
8.1 Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refillinq the trench etc as required.
344 8.1 Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as reauired.
346 DSR 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
357 14.14 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
14.16 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
TOTAL OF SUB-HEAD A
SUB HEAD B - SCHEDULE ITEMS
361 7.8 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
41.4 XLPE insulated FRLS heavy duty power cable Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor
Safety Equipments & Accessories
375 MP SOR-24 42.77 Rubber mat- Supply of rubber mat 2 x 1.0Mtr, 1100V tested each 15 1,913.00 28,695.00
376 MP SOR-24 42.83 Shock instruction chart -Supply of shock instruction chart duly framed with glass, as reqd. each 4 539.00 2,156.00
377 MP SOR-24 42.78 Hand gloves -11KV Supply of hand gloves 11KV tested each 2 1,077.00 2,154.00
378 MP SOR-24 42.82 First aid box- Supply of first aid box complete with medicine & bandage as per specification. set 1 1,646.00 1,646.00
Substaion wok included follwing works Following items are under the scope of contractor's work and no extra payment will be made for same 1) Apply and getting NOC from electrical inspector at own cost 2) Providng green/ installation card with electrical license 3) Getting work order before start of HT work and NOC from SBPDCL at own cost 4) Energizing the transformer after application of meter from parent deparment through SBPDCL.
160 KVA, 11KV/ 415V OIL TYPE DISTRIBUTION TRANSFORMER
Supply of following capacity (continous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site . The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.
Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature;
c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers.
Make- Red Phase, E wave, Infra Power or approved equivalent as per approval of EIC
379 160 KVA TRANSFORMER SET 1 284,474.00 284,474.00
RATES from Electrical NBPDCL Vetted copy
382 11 KV PIN INSULATOR with pin nos. 12 118.00 1,416.00
383 11 KV V cross arm nos. 4 796.81 3,187.24
384 11 KV Top insulator bracket nos. 4 268.41 1,073.64
385 back clamp for V and top nos. 8 133.56 1,068.48
386 ACSR Rabbit conductor km. 0.3 48,722.22 14,616.67
387 Transformer DP Top and base channel set 2 4,201.50 8,403.00
388 AB Switch channel set 2 3,025.88 6,051.76
389 HG Fuse channel set 1 3,025.88 3,025.88
390 Clamp for channels nos. 12 104.73 1,256.76
391 Transformer fastening angle nos. 2 1,977.71 3,955.42
392 back clamp for fastening angle nos. 4 154.69 618.76
393 Earthing materials set 3 1,822.00 5,466.00
394 11 kv AB Switch 400 ampere set 1 16,461.00 16,461.00
395 lightening arrester set 1 1,046.53 1,046.53
396 HG Fuse set set 1 7,382.69 7,382.69
397 Danger board nos. 1 68.00 68.00
399 Tapping Bracket nos. 6 728.45 4,370.70
400 11 kv Disc insulator nos. 4 448.00 1,792.00
402 Sundries LS 15,000.00
403 Contigency @ 2% of A 10,057.12
404 C. Transporation @ 4% of A 20,114.25
406 Labour cost @ 10% of A 50,285.62
407 Labour Cess 1% of total schedule rates 2,183.82
DIESEL GENERATOR SET
Make- Kirloskar, Mahindra, Cummins of approved equivalent as pe approval of EIC
DSR 2025 Supply of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as perrelevant IS Code etc. and consisting of the followings:
(A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital disPlate for following:
(i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
(G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( L-N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set. 7. Fuse/ MCB for instruments. 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
9. Main supply failure monitor. 10. Supply failure timer. 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
Make- Daikin, Carrier, O General, Mitushubishi or approved equivalent
DSR-2025 Contractor have to design and submit shop drawing of HVAC and get is approved before start of work
HI - WALL SPLIT SYSTEMS
DSR 8.2 Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) including outdoor stand if required..
409 32.2.2 1.0 TR with 5 Star BEE Rating Each 2 40,580.00 81,160.00
BCD 1 Split ac (Inverter Model, Cooling Only) - Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410 A . The condensing unit working range should be capable for providing cooling between +/- 5 deg C to 50 deg C & heating within 0 deg C to 15 deg C including connection of copper pipe of required size upto 3 mtr, insulation, cordless remote control , auto air swing louvers, connection copper lead wire , condensed water outlet pipe 2 mtr complete etc as required. Outdoor / indoor units should be of same make . The cost includes contractor profit, labour cess, supply , transportation cost, installation, testing and commissioning cost including outdoor stand if required.
CASSETTE TYPE SPLIT UNITS
2.0 Cassette AC (Ceiling suspended / mounted cassette type 4 way unit with inbuilt drain pump & decorative panels- Supply installtion testing and commissioning of split type ceiling cassette air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refreigerant R 410 A / ecofriendly green gas only, cordless remote control. auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr, excluding connection copper pipe of required size , insulation , floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/ indoor units should be of same make. The cost includes contractor profit, labour cess, supply, transportation cost, installation, testing and commissioning cost including outdoor stand if required.
BCD-23 AR COPPER REFRIGERANT PIPING
9.0 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
415 9.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 100 560.00 56,000.00
416 9.1 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 212 693.00 146,916.00
417 9.1 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 100 813.00 81,300.00
418 9.1 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 212 1,031.00 218,572.00
419 9.1 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 161 1,049.00 168,889.00
420 9.1 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 58 1,150.00 66,700.00
421 9.1 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 161 1,473.00 237,153.00
422 9.1 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 58 1,640.00 95,120.00
7.0 Drain piping :-· Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification .
424 MR SITC of Stand for the outdoor unit- For Hiwall Unit/Cassette Each 28 1,500.00 42,000.00
MP SOR 2024 - 46.44 Fresh air in line fan- Fresh air in line fan: - Supply, installation, testing and commissioning of fresh air inline fan.
425 46.44.1 100 CFM -100 CFM (static pressure upto 20 mm) EACH 5 5,473.00 27,365.00
BCD APPROVED RATE
17.0 Ducting:- Supply and fixing of site fabricated GI sheet metal ducts in accordance with the approved shop drawings and as required as per specifications. GI sheet will be as per 15-277. All necessary GI /MS supports using thread rods (as directed). Angle, flat, and anchor bolts, food grade neoprene gaskets, food grade adhesive included in the scope.
427 18.0 Thermal insulation :- Supplying and fixing of following thickness of mat finish closed cell nitrile rubber (class "1") insulation on existing duct after applying two coats of cold setting adhesive complete as per specifications and as required.
LIFT (Schedule Items)
MP 2024 44.1 Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and fulfilling following requirements. (i) Type: Passenger lift. (ii) Load: As specified elsewhere from 4 passengers (272Kg) to 26 passengers (1768Kg) (for each person standard weight 68Kg.). (iii) Speed: 1.00 metre/sec. or less as required. (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software. (v) Motor/machine: Permanent magnetic synchronous gearless motor.
(vi) Operation: Simplex collective selective with/without lift attendant. (vii) Total rise: About 3 mtrs. (approx) two stops only. (viii) Landings: All floors on same side. (ix) Floors served: G+1. (x) Signals: Digital car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car. (xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately. (xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xvi) Car door: S.S. (stainless steel) hairline finish centre/telescopic opening door with vision panel. (xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with vision panel. (xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams. (xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides. (xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform. (xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights (xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided). (xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car. (xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room.
(xxv) Emergency alarm: Battery operated alarm bell system in lift car & control room / ground floor. (xxvi) Position of machine room: Directly above the hoist-way. (xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V 1phase 50Hz terminated in machine room. (xxviii) Fire man switch : Fire man switch at machine room/terminal landing (xxix) All car panel buttons and all floor switches must be with Braille language as per lift act. (xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed. (xxxi) Spring buffer/hydraulic buffer shall be provided (xxxi) Spring buffer/hydraulic buffer shall be provided (xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxxiv) In the hoist way fascia plate shall be provided. (xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level. (xxxvi) Car top safety barricade shall be provided. (xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure. (Make- Otis, Kone, Schindler or approved equivalent as per approval of EIC)
Add extra to item no. 44.1 for every additional floor beyond initial G+ 1 floor (additional stops beyond two stops) provides all necessary additional parts/equipments as per manufacturer's requirement.
429 44.3.1 + GST @ 18% Cost for each additional floor : upto 9 stops (For 4-10 Passengers) Each 4 79,650.00 318,600.00
Add extra to item no. 44.1for machine room less (MRL) lift in place of machine room directly above the hoist way.
430 44.4.1 + GST @ 18% Extra cost for machine room less (4-13 Passenger) Each 2 159,300.00 318,600.00
ELEVATION - WORK
The fixing details are to be approved by the E/I. Shop Drawings / samples are to be approved by the E/I
Make- Saint Gobain, Modiguard or approved equivalent as per approval of EIC
431 25.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. kg 4210.46 414.30 1,744,393.58
Mild Steel Work:
432 10.1 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
10.14.2 Hot finished seamless type tubes Kg 24500 206.35 5,055,575.00
433 10.3 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.
434 Analysis Add SBPDCL Supervision Charge (B) Job 105,413.00
Total Schedule Amount (Rs.) (A+B) 75,898,919.67
(Re-Tender) बिहार राज्य खादी ग्रामोद्योग बोर्ड के मुंगेर स्थित जमीन पर खादी मॉल के निर्माण
NON-SCHEDULED ITEMS
S. No. ITEM NO. DESCRIPTION OF ITEMS UNIT QTY Quoted Rate In Figure(Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Rate In Word (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Amount (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect)
1 N.S Providing and fixing of 12 mm thick wooden ply paneling with or without frame so as to receive a plain and even surface in exact plumb line , covered with 1mm thick laminate finished of approved shade and make as per the design and as directed by the Architect in approved style and patter Sqm 460.00
2 N.S. Providing and fixing plywood partition of appropriate size having thickness of 75 mm, made up of 50 mm x 38 mm teakwood supporting members at a vertical distance of 0.9 m c/c and horizontal distance of 0.9 m c/c covering on both face with 19 mm thick Plywood Conforming to ISI-303 finished with 1.2mm thick Laminate of approved make, shade on both side, & 63mm high. aluminum skirting finished with powder coating matching to laminate including pasting, screwings, cutting, jointing, finishing, fixing to the walls etc. as shown in the drawing and design provided by the Architect, and antitermite treatment to wood, plywoods and MDF etc. complete as directed by Engineer -In-Charge. Sqm 340.00
3 NSI Glass partition - Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including providing and fixing top & bottom arrangement and making necessary holes etc. for fixing required partition fittings, all complete as per direction of Engineer-in-charge sqm 120.00
4 Door- Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing door machine, Door handle, lock and stopper. arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
NSI Door - 1500mm - DoubleDoor- W1500mmx H2400mm Nos 4.00
Plumbing & Fire Fighting Work
5 MR-01 Providing & fixing S.S. health faucet for ablution with 1.2 meter long PVC tube, hand shower, couplings, wall hook and other accessories of quality and make as approved by architect. 9.00
6 MR-02 Providing and fixing Heavy Class SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT & FD as approved by architect and complete in all respect..
7 Size 100 mm X 100 mm 22.00
8 MR-03 Providing and fixing Heavy Class Cockroch Type SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT as approved by architect and complete in all respect..
Size 127 mm X 127 mm 0.00
INTERNAL DRAINAGE
9 MR-04 Providing, fixing, jointing, testing and commissioning UPVC (Class B) Rain water downtake pipe conforming to IS:13592 cut to required lengths including all necessary fittings and specials.UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab and making good wherever required. (All major MS structure to hold the stack with fixing including anchor fasteners,sand, cement etc is included in this item).
110 mm dia 77.25
MR-05 Providing, fixing, jointing and testing UPVC soil, waste, vent pipework comprising UPVC pipe conforming to IS :4985-1983 of class 3 ( 6kg/cm2) as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps, suitable elbow with suitable extension piece for drain point and other specials jointing with cement solvent, chasing, cutting and making good the walls & floors pipes laid in floors shall be encased with 40 mm thick concrete all around, complete in all respects including testing of complete installation.(All major MS structure to hold the stack with fixing including anchor fasteners, sand, cement etc is included in this item)
10 110 OD 6 kg/cm2 (Class III ) 160.50
11 40 mm dia 6 kg/cm2 (Class III ) 13.80
12 50 mm dia 6 kg/cm2 (Class III ) 13.20
MR-06 Providing and fixing UPVC/SWR trap (P trap) of self cleaning design as per IS:13592 : 1992 complete including cost of cutting and making good the cutouts in walls and floors etc.including cutting and making good the walls and floors wherever required complete as approved by architect and complete in all respect. as approved by architect and complete in all respect.
13 110 mm inlet and 110 mm outlet 14.00
14 MR-05 Providing and fixing floor drain made out of 75x50 mm OD uPVC. elbow connected to uPVC pipe complete as per direction of Project Manager as approved by architect and complete in all respect as approved by architect and complete in all respect. 8.00
15 MR-07 Providing and fixing Inlet Fitting for Urinal trap, formed out of 110 mm PVC pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 including cutting and making good the walls and floors wherever required as approved by architect and complete in all respect.. 5.00
16 MR-08 Providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as required as approved by architect and complete in all respect.. 1.00
17 MR-09 Providing and fixing cleaning eye 110mm dia on horizontal UPVC soil & waste pipes of 300 mm long UPVC pipe with one plain end lead caulked in to the collar of UPVC pipe and the other end with flange which in covered by neoprene rubber gasket and blank flange, complete with nuts, bolts etc and hot dip galvanization after fabrication to the satisfaction of Project Manager as approved by architect and complete in all respect..
100 mm dia 10.00
DRAINAGE- EXTERNAL
MR-10 Providing & Fixing DWC ID SN-8 Pipe(HDPE Black Pipe) with Coupler & Rubber Ring as per IS:16098(PART 2)
18 150 mm Dia mtr 70.00
19 200 mm Dia mtr 22.00
20 250 mm Dia mtr 0.00
21 NS-1 Providing and fixing self glowing Exit sign board size 350x200mm single side painted made of luminescent safely, rigid sheet in standard colour photo, luminescent sheet made of crystals consisting mainly sulphide in protective glass like sheet green and yellow crystal luminescent (glass in dark) by action of light. Each 4.00
TUBE WELL-Boring Depth 100mtr Consider
22 MR Supply , Installation of Electronic chlorinator complete as directed by Engineer-in-Charge. Set 1
FIRE FIGHTING WORKS
23 MR-22 Providing, Installation, Testing and Commissioning of Gun Metal / Bronze Ball Valves screwed ends of following sizes as required. (For sprinkler drain )as approved by architect and complete in all respect. (MAKE - ZOLOTO , SANT, EQV.) Nos 5
MR-23 SITC weather proof M.S cabinet size 1350 mm x 900 mm x 600 mm
24 Supplying, installation, testing and commissioning of weather proof M.S cabinet size 1350 mm x 900 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the followingas approved by architect and complete in all respect. (Make - Exflame, Swastic, Safeguard)
The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade. Each 5
25 MR-24 Supply, installation, testing and commissioning of ISI marked (IS:15683:2006) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specificationsas approved by architect and complete in all respect.(Make - Exflame, Safex, Safeguard, Eqv.) Each 10
26 MR-25 Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed conforming IS : 15683:2006as approved by architect and complete in all respect.(Make - Exflame, Safex, Safeguard, Eqv.)
4.5kg capacity cylinder Each 10
PLUMBING WORK FOR HIGH SIDE
SUBHEAD - I- WATER SUPPLY PUMPS & EQUIPMENT
Submersible water transfer pumps
27 Supplying, installing, testing and commissioning of submersible water transfer pumps in Underground water tanks, having SS casing, SS impeller, SS shaft with mechanical seal, directly coupled with motor, 2900 rpm including pressure gauge on delivery line with gunmetal isolation cock, nuts, botls including float type level controllers, electrical control panels fabricatd from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Each pump shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C. Electric supply and shall be of the capacity as under One Set (1W+1S), including all necessary piping, valves and gauges. Vibration elimination pads shall be included as part of quoted rate. Control and Power Cable from pump to panel to be in plumbing contractor scope. Control cabling from OHT to UGT to be in electrical contractor scope. Routing and location to be provided by plumbing contractor at site. Pumps shall be "ultra low noise" with a db level of not more than 60 db
28 MR-11 Domestic Riser Sump Pump(Open Well Pump) Capacity : 100 LPM Each Pump (1 Working + 1 Standby) @ 45 M head. (location at UGT ) Make-Ebara Set 1
Receiving, unloading, storage, assembly, erection, testing and commissioning of SS/CI submersible pumps for domestic water pumping system comprising of: as approved by architect and complete in all respect.
Supply, installation, testing and commissioning of free standing vertical type electrical submersible pump sets of following capacity capable of domestic water supply in tube well, with water cooled electric motor for effective cooling, the wearing parts such as Impeller, shaft sleeve, pump casing etc. shall be C.I & Impeller bolt shall be AISI 316 and of adequate power for operation on 415+ 1 volts, 3 phase, 50 Hz AC electric supply including fixing of delivery pipe with a flanged outlet. The cost will include providing and fixing suitable standard electrical panel from the same manufacturer as the pump, including float type level controller for level control and for cyclic operation of pumps, all electrical cables including submersible cables of required length and making all necessary electrical connections, terminations etc complete in all respects.
The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head.
Pump suitable for domestic water
29 MR-12 For tube well water supply Capacity :165LPM Each Pump (1 Working) @ 56 M head (location in tube well). Make-Ebara No. 1
SUBHEAD -VIII - MISCELLANEOUS ITEMS
MR-13 Providing and fixing M.S. puddle flanges (fabricated of 750 mm long pipe pieces) to R.C.C. water tanks wall / slab. The entire fitting shall be hot dipped galvanized (Flanges shall confirm to BS10 Table E) as approved by architect and complete in all respect.. .
30 25 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 6
31 40 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 4
32 50 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 4
33 65 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 2
34 80 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 4
35 100 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 2
36 150 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). Nos. 1
37 MR-14 Providing and fixing in position G.I. vent with brass mosquito proof coupling and air filter including return bend, complete as required. The entire fitting shall be hot dip galvanizedas approved by architect and complete in all respect.
100 mm dia Nos. 4
38 MR-15 Providing, testing & commissioning of dial type pressure gauge with pressure scale of 0 to 15 kg / cm2. Provision of isolation cock suitable for pressure of 15 kg / cum2 shall be included in cost. No. 4
39 MR-16 Supply complete testing kit with all chemicals complete suitable for conducting test on water quality. The test kit shall be suitable to measure TDS, pH, Hardness, Iron content and other parameters (Make : Ion Exchange)as approved by architect and complete in all respect.. No. 1
40 MR-17 Providing & fixing in position Vane Type mechanical water flow meter for following pipe sizeas approved by architect and complete in all respect..
UPTO 50 mm dia No. 1
41 MR-18 Providing, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.
25mm dia Each 1
MR-19 Providing and fixing Expansion flexible bellows between existing puddle flange in water tank retaining wall and proposed puddle flanges as mentioned under item No. 3 above. The bellow flanges shall match with exiting puddle flanges at site as approved by architect and complete in all respect.
42 50 mm dia Each 1
43 65 mm dia Each 1
44 MR-20 Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions as approved by architect and complete in all respect.. Set 2
To switch on the pumps (including tube well pumps 2 nos., Domestic Water Treatment etc.) To cut off the pump when the level in the receiving water tank is high and switch off the pumps when the level of water in the supply water tank is low.
To indicate 3 levels of water in all tanks through a control panel with LEDs
To start the pumps in a cyclic order.
The system shall be complete to ensure automatic quotation of pump in accordance to water level in respective tanks.
The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item
45 MR-21 Supply, installation, testing and commissioning of tanker inlet connection complete with 80 mm dia GI inlet piping, hose inlet connection, MS cabinet enclosure (epoxy painted after fabrication), pad locking arrangement, inlet flexible hose complete with all necessary arrangementas approved by architect and complete in all respect.. Nos 1
Electrical Work
LIGHTING FIXTURES
SUB HEAD D - NON SCHEDULE ITEMS
46 MR Supply installatin testing and commissioning of 45/50 Watt Recessed LED (ROUND) Light Fitting Make- Philips, Wipro, Orient, HPL or approved equivalent as per approval of EIC NOS. 12
47 MR Supply installation testing and commissioning of Pendent light with OEW recommended LED Bulb (Make- Wipro BeuHome BP03, PHILIPS Vivid Pendant (582024), Jaquar Pendant JNL-COP-SLPEA031BE27, Philips, Wipro, Orient, HPL or approved equivalent as per approval of EIC NOS. 12
48 MR Supplying and fixing recess mounted 3X20 watt COB based multiple zoom light make with all accessories (track , connector, suspension etc), directly on false ceiling including connection with 1.5 sq. mm FR PVC insulated copper conductor cable and earthing the body etc. as required. (Track light) Make- LD57-251-60-57-WG1 wipro, Philips, Orient, HPL or approved equivalent as per approval of EIC Each 45
Internal Panels : LT PANELS
49 Make of MCCB/MCB/ Metering- Lk, Legrand, Schneider, Siemens, ABB or approved equivalent as per approval of EIC
50 Note- Contractor have to submit all PANEL power wiring, control wiring , GA drawing, SLD, BOM, Type test certificate, Routine/Factory test report before approval of Panel
Panel maufacture will start only after approval from EIC
After intallation of Panel Panel Rating & Protection Detail, Installation and commissioning report, earthing detail, warranty and guarantee certicate etc need to be submited before final payment.
Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & indoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or equivalent as per approved make list and as direction by engneer in charge. PTTA Panel
1 nos. 320A 415V, Ics=36KA, 4P MCCB with MICRO PROCESSOR WITH O/C ,E/F ,S/C protection.
1 nos. 320A 415V, 4 POLE Contractor with Auxilary Cotact.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 320/5A.
1 Set of phase indicating lamp with MCB
1 Set of On,Off Trip lamp
1 set under voltage relay
1 set over voltage relay
1 nos. 250A 415V, Ics=36KA, 4P MCCB with MICRO PROCESSOR WITH O/C,E/F,S/C protection.
1 nos. 250A 415V, 4 POLE Contractor with Auxilary Cotact.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 250/5A.
1 Set of phase indicating lamp with MCB
1 Set of On,Off Trip lamp
1 set Reverse Power Relay
500A TPN Bus bar of aluminimum alloy.
160A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 2 N.o.
100A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 2 N.o.
63A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 5 N.o.
63A 415V, Ics=25KA, TP+N MCCB with TM release having adjustable O/L, S/C protection. – 1 N.o + 63A 4P Contractor.for solar
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 63/5A. With control MCB
1 Set of On,Off lamp.
1 set Reverse Power Relay
40 A, FP,10KA, MCB – 1 N.o.
51 Total Main LT Panel NOS. 1
CAPACITOR INCOMER :-
1 No. Main Income 63A, TP+N, MCCB (25KA) with Thermal Magnetic Release for Over load, Short circuit Protection
One sets of 100A,TPN AL. Bus Bar with PVC Sleeve in sealed Bus Chamber.
METERING, INDICATION AND RELAY :
1 Nos. Digital Amp Meter with Current Transformer backed up with 6 Amps MCB
1 set Automatic Power Factor Correction Relay (8 Steps) with digital Power Factor Meter
One set of R/Y/B phase indication Lamp with control MCBs.
1 No. Auto / Manual Selector Switch
1 set of Aux. Contactors
1 No. timer for manual mode switching
1 Set of 1KVAR Capacitor bank 1X3Kvar Capacitor Duty Contactor and 10 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
1 Set of 2KVAR Capacitor bank 1X3Kvar Capacitor Duty Contactor and 10 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
1 Set of 3KVAR Capacitor bank 1X3Kvar Capacitor Duty Contactor and 10 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
2 Set of 5KVAR Capacitor bank 1X5Kvar Capacitor Duty Contactor and 15 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
1 Set of 10KVAR Capacitor bank 1X10Kvar Capacitor Duty Contactor and 32 A TP MCB (10kA) Capacitor rating to be designed for required output KVAR at 415V.With 7% Harmonic Reactors.
52 Total Capacitor Panel Nos 1
LIGHTING & POWER PANEL
1 nos. 160A 415V, Ics=36KA, TP+N MCCB with TM Release WITH O/C,E/F,S/C protection.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 320/5A.
1 Set of phase indicating lamp with MCB
200A TPN Bus bar of aluminimum alloy.
63 A, FP,10KA, MCB – 7 N.o.
40 A, FP,10KA, MCB – 7 N.o.
53 Total Lighting & Power Panel Nos 1
1 nos. 100A 415V, Ics=25KA, TP+N MCCB with TM Release WITH O/C,E/F,S/C protection.
1 Set of phase indicating lamp with MCB
150A TPN Bus bar of aluminimum alloy.
40 A, FP,10KA, MCB – 6 N.o.
40 A, DP,10KA, MCB – 1 N.o.
32 A, DP,10KA, MCB – 1 N.o.
54 Total UPS Panel-1 Nos 1
1 nos. 63A 415V, Ics=25KA, TP+N MCCB with TM Release WITH O/C,E/F,S/C protection.
1 Set of phase indicating lamp with MCB
150A TPN Bus bar of aluminimum alloy.
40 A, FP,10KA, MCB – 2 N.o.
40 A, DP,10KA, MCB – 6 N.o.
55 Total UPS Panel-2 Nos 1
FEEDER PILLAR PANEL
40 A, FP,10KA, MCB – 1 N.o.
1 Set of phase indicating lamp with MCB
32 A, FP,10KA, MCB – 1 N.o.
32 A, DP,10KA, MCB – 1 N.o.
20 A, FP,10KA, MCB – 1 N.o.
40 A, FP,10KA, MCB – 1 N.o. as a incomer
1 Nos. 40A TP Contactor (AC 3 Duty with 230V Control Coil)
1 Nos. 24 hour double dial programmable time switch on Auto mode arrangement for Auto/Manual selection, Push Buttons, Indication lamps & Control fuses etc as required .
One (1) no. Mushroom head type emergency stop push button with under voltage release.
100A TPN Bus bar of aluminimum alloy.
10 A, SP,10KA, MCB – 4 N.o.
56 Total Feeder Pillar Panel Nos 1
PLUMBING & FIRE PANEL
1 No. 63A, TP+N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection
One set of 100 A TPN Alu. Bus Bar, 36kA with PVC Sleeve in sealed Powder Coated Bus Chamberas approved by architect and complete in all respect.
METERING AND INDICATION :
1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCB's (Eqv. To EM6436)
One set of R/Y/B phase indication Lamp with control MCBs.
1 Set of ON/OFF Indicating lamps .
1 Nos. 10A TP MCB (10KA) with DOL Starter for 3 KW
2 Nos. 10A TP MCB (10KA) with DOL Starter for 1.5 KW
1 Nos. 32A TP MCB (10KA) with Star Delta Starter 9.3 KW for Fire Booster Pump
2 Nos. 32A TP MCB (10KA)
57 Total Plumbing & Fire PANEL Nos 1
58 MR Supply of (Make- zyxel/Arista/HP/ CISCO) Ports Managed PoE+ Layer 2 Access Switch - L2 ACCESS SWITCH 28 Port along with necessary connectors, SFP modules, transceivers, configuartion of switch, etc in all manner ready to use. EACH 4
Contractor have to submit shop drawing of furniute on his own cost
Make - Godej, Durian, Vinar,HNI, Zura , SBDEE, Balance Art Construction, Fordela impex pvt ltd or approved equivalent as per approval of EIC
59 Cash counter Supply and placing reception table as per the picture. Table Size is 3200Lx2700D/1200Dx750ht/1050Ht. Working Table top 600mmD shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. Table modesty shall be made of 18mm thick prelaminated particle board. Table having 2nos of fixed drawer. 2+1 filling drawers shall be made out of 18 mm thick prelaminated particle board.Working Table side tops (L.H.S & R.H.S) depth is 450mm (D). Table having upper ledge shall be made of 25 mm thick prelaminated particle board and 200 mm wide. Gable end shall be made out of 25 mm thick prelaminated particle board with pvc edge banding tape, wire manager hole will be cut in the top for the wiremanagement. No 1
60 Reception Chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.It shall having pp fixed arms .It shall have tilt mechanism with the locking arrangement with gaslift. No 2
61 Seating couch Providing and placing 2 Seating couch as per photograph. Size of the couch is 1500Lx450Dx400Ht. The seating couch frame shall be made of seasoned wood and couch having fabric tapestry in the couch foam used high density 42-45mm/cm.Couch foam upholstery with the fabric tapestry. wooden gutka will be used in the bottom. No 4
62 Hexa Island display Counter Supply and placing island display as per the picture. Island Size is 1800Lx1500Dx1050Ht. Shelves and base shall be made of 18mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. Display central part shall be made of 18 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. No 3
Rectangle island display Counter Supply and placing Rectangle island display counter as per the picture.Counter Top, Sides and bottom shall be made of 18mm thick prelaminated particle board with pvc edge banding tape. Display counter having front side cover with the clear toughened glass. Counter having Toughned glass shelves for the clothes display.
63 Size 1500Lx600Dx1050Ht. EACH 8
64 Size 1350Lx600Dx1050Ht. EACH 4
65 Size 1200Lx600Dx1050Ht. EACH 4
66 Size 750Lx750Dx1050Ht. EACH 2
67 Director Room Cabin Table with Side unit Supply and placing Director table as per the picture. Table Size is 1800Lx750Dx750ht/1050Ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. Table understructure shall be made of 25/18mm thick prelaminated particle board. Table having side openable shutter storage with the 2+1 filling drawer.Table top support with the studs on the side unit top and gable end. Side unit 1800L(1050+750)X450DX750HT. Top shall be made of 25 mm thick prelaminated particle board and understucure shall be made of 18mm thick prelaminated particle board.Side unit having openable shutter + drawer. Flipper will be place on the top for wiremangement. Powder coated cable tray and wireriser will be provide below the side table top for the wiremanagement. EACH 1
68 Main Chair Providing and placing High back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the Leatherite. Back shall be upholstered with Leaterite . Chair having metal chrome base with the castors.Chair having metal fixed arms with pu pad.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 1
69 Visitor Chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the Leatherite. Back shall be upholstered with Leaterite . Chair having metal chrome base with the castors.Chair having metal fixed arms with pu pad.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 2
70 Cabin - 1 and 2 Table with Side unit Supply and placing officer table as per the picture. Table Size is 1500Lx600Dx750ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape. wiremanager hole with cap will be provide on the table top for the wiremanagement . Table understructure shall be made of 18mm thick prelaminated particle board. Side unit Size :- 900Lx450Dxs750Ht. Side unit top and understructure shall be made of 25/18mm thick prelaminated particle board. Side unit having openable shutter with the 2eq drawerin upper side. Side unit having neccessary hardware. EACH 2
71 Main Chair Providing and placing High back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having PU adjustable arms with up and down system.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 2
72 visitor chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having PU adjustable arms with up and down system.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 4
73 Staff Area Table with Mobile Drawer Supply and placing Staff Table as per the picture. Table Size is 1350Lx600Dx750ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape.wire manager hole will be cut on the table top for the management. Table understructure shall be made of 18mm prelaminated paticle boardas per approved laminate. Mobile Drawer Size :- 400Lx450Dxs680Ht.Drawer unit shall be made of 18mm thick prelaminated particle board. Drawer having castors for the movement. EACH 6
74 Staff Chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having pp fixed arms .It shall have tilt mechanism with the locking arrangement with gaslift. EACH 5
Open Slotted angles Providing and placing the Ms slotted angles as per the pictutre. The Open slotted angle rack shall be made of MS slotted angle 2.0 mm thick.with the nut and bolts. The rack having 5 shelf storage unit, shelves are made of CRC Sheet 1 mm thick , simple stylish design comes with various colors options, easy to clean just wipe with clean dry cloth, easy to assemble & use. All metal part duly powder coated with the 50-60 microns
77 Meeting Table Supply and placing Meeting table as per the picture. Table Size is 2400Lx1200Dx750ht. Table top shall be made of 25 mm thick prelaminated particle board as per approved laminate with pvc edge banding tape.Table under structure shall be made out of 18mm thick prelaminated particle board. Table having metal flipper 400x120 mm for the wire management. table having metal cable tray below the table top for provion of the switch mounting tray with metal cable riser. EACH 1
78 chair Providing and placing Medium back revolving chair as per photograph. Chair seat shall be made of 12mm thick commecial ply, seat shall be upholstered with the fabric. Back shall be upholstered with mesh. Chair having nylon base with the castors.Chair having PU adjustable arms with up and down system.It shall have tilt mechanism with the locking arrangement with gaslift. EACH 6
79 ELEMENT :Providing & making open display unit of any size(L)x 450(D) x2640/1200/900(HT) . The display rack top, sides , shelves and bottom shall be made of 18 mm thick prelaminated particle board as approved laminate shade design and colour.all exposed edges shall be covered with the pvc edge banding tape. Sizes are mentioned Below for saree section / display units for Male and Female sections :- Ground Floor 1. 8500(L)x450(D)x2640(Ht)=1 no 2. 7955(L)x450(D)x2640(Ht)= 1 no 3.5650(L)x450(D)x2640(Ht)= 1 no 4.3000(L)x450(D)x1200(Ht)= 1 no 5.1800(L)x450(D)x1200(Ht)=1 no First Floor 1. 9490(L)x450(D)x2640(Ht)= 1no 2.2250(L)x450(D)x2640(Ht)=1 no 3.4000(L)x450(D)x2640(Ht)=1 no 4.8750(L)x450(D)x2640(Ht)=1 no 5.2700(L)x450(D)x1200(Ht)=1 no 6.11310(L)x450(D)x900(Ht)=1 no sqm 155.3898
80 Show window - Providing and fixing plain lining with necessary screws/nuts & bolts/ nails,complete as per direction of Engineer-incharge 12mm thick commercial BWR GRADE BOARD / ply conforming to IS : 1328 BWR type with 1 MM THICK laminate finish as per specification table below show window having with glass etc. from either SUPA OR ADVANCE company). sqm 55
81 Mannequin full height 1800 mm nos. 10
82 Bed with Storage for Saree Section. Bed shall be made of 18 mm thick prelaminated particle board with the balancing laminate. Bed seat having 12 mm thick commercial ply. Bed having openable panels for storage purpose. sqm 15.3
Note for Furniture Work
Shop Drawings will be provided by the vendor and will be verified by the Architect/EIC.
All the works for installtion and fixing should be executed by the certified agency as approved by the Architect/EIC.
All items necessary for the completion of system but not mentioned in BOQ shall be included by the contractor without any extra cost.
ELEVATION - WORK
83 N.S providing, supplying and fixing of 6 mm tinted float glass, with visible light transmittal of minimum 28 %, with solar factor not less than 30 and with u value not less than 3.7 with allnecessary hardware and fittings as directed by Engineer in charge sqm 526.3075
84 N.S. Extra for openable side / 6 mm tinted float glass top hung vision glass panels including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. sqm 52.63075
85 N.S. Providing and applying Duco paint finish on M.S. surface including cleaning, sandpapering, and preparing the surface; applying two coats of zinc chromate/epoxy primer and two coats of Duco paint of approved shade and make (e.g. Asian / Nerolac / Equivalent), applied by spray method to achieve a smooth and uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. sqm 550
i) Shop Drawings will be provided by the vendor and will be verified by the Architect/ EIC.
ii) All the works for installtion and fixing should be executed by the certified agency as approved by the Architect/EIC
iii) All items necessary for the completion of system but not mentioned in BOQ shall be included by the contractor in above cost.
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-10 SBD Khadi Mall Munger.pdf
NIT • 2.99 MB
10TEN2026_0001.pdf
NIT • 2.48 MB
10TEN2026_0001.pdf
NIT • 2.48 MB
Corrigendum_01_NIT10.pdf
NIT • 0.50 MB
NIT-10 SBD Khadi Mall Munger.pdf
NIT • 2.99 MB
NIT-10 TB Khadi Mall Munger.xlsx
NIT • 0.08 MB
NIT-10 FB Khadi Mall, Munger.xlsx
NIT • 0.15 MB
NIT-10 FB Khadi Mall, Munger.xlsx
NIT • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .