Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-Finance Qualified as Rank L1 | |
| 2 | L2₹19.5 L+₹1.5 L (8.31%)Rejected-Finance | L2 | Rejected-Finance Rank L2 | |
| 3 | L3₹21.1 L+₹3.1 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Rank L3 | |
| 4 | L4₹23.2 L+₹5.2 L (28.7%)Rejected-Finance | L4 | Rejected-Finance Rank L4 | |
| 5 | L5₹23.4 L+₹5.3 L (29.6%)Rejected-Finance NONE | L5 | Rejected-Finance Rank L5 |
Tender Value
₹26.9 L
EMD Value
₹53,745
Closing Date
29 Apr 2026, 3:00 pmClosed
Executive Engineer(E)
Executive Engineer (E), PWD HMED SW (NCTD), Ist floor, Samaj Sadan, DAP Lines, Vikas Puri, New Delhi
Replacement of Old Fittings, Fans with new energy efficient fittings at various areas at DDU Hospital. Hari Nagar, New Delhi
2026_PWD_290153_1
03/EE(E)/PWD HMED SW/2026-27
Open Tender
Electrical Works
Works
60 days
Deen Dayal Upadhyaya Hospital
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹53,745
11 May 2026
21 Apr 2026
29 Apr 2026
21 Apr 2026
29 Apr 2026
21 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) | |||||
| 1.01 | 36 Watt | - | Each | - | - |
| 2Suppling, Installation, Testing and Commissioning of 450 mm Sweep Wall Fan with metal blade on the wall with dash fastener, connection with 1.5 sq mm FRLS PVC insulated wire complete i/c dismantling of old unit as required | |||||
| 3Supplying & Fixing of 400 mm Sweep Hi Speed Domestic Wall Mounted Fans on the wall with dash fastener, connection with 1.5 sq mm FRLS PVC insulated wire complete etc. as reqd | |||||
| 4Suppling, Installation, Testing and Commissioning of 600 mmm Sweep Heavy Duty Wall Mounted Air Circulator Fans on the wall with dash fastener, connection with 1.5 sq mm FRLS PVC insulated wire complete etc. as reqd. | |||||
| 5SITC of Storage Water Cooler Cum Purifier with 120 Liter Storage and 60 Liter Cooling having inbuilt Eight Stage Reverse Osmosis purification System ;suitable for operation on 230 VAC ,50 HZ with Power Consumption 850 Watts+_ 10% providing water outlet temperature at 15 degC with UV Lamp Filtration for effectively preventing post microbial contamination in the storage tank. Refrigerant should be HFC R-134 A and Compressor make Emerson. Filtration stages should be as Particulate Filter- 20 inch ; Pre Carbon Filter- 10 inch; Anti-Scalant Cartridge- 10 inch; Sediment Filter- 10 inch; RO Membrane-80 GPD X 04 Nos; Post Carbon Filter- 10 inch; UV Lamp-8 Watts. The storage tank material of SS304 & outer body material of GI Powder Coating. The product should have 3 faucets along The product manufacturer must have their NABL Accredited Lab Testing facilities in Delhi. The Product should be ISO 9001 and Indian Medical Association Certified. | |||||
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_385190.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .