Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 47 HANDWARA HANDWARA HANDWARA BUDGAM JAMMU KASHMIR 191111 | BUDGAM | JAMMU AND KASHMIR | 191111 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
22 Mar 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Srinagar
Barbarshah Maisuma Srinagar
Internal Electrification Of Workshop Block For Industrial Training Institute Women at Bemina Srinagar
2021_PWDJK_120373_1
E/166/2020/21dtd15/03/2021
Open Tender
Electrical Works
Item Rate
20 days
Internal Electrification Of Workshop Block For Ind
as per BOQ
7 documents required · 7 mandatory
₹1,100
Executive Engineer RNB Electric Division Srinagar
Exempted
22 Mar 2021
15 Mar 2021
22 Mar 2021
15 Mar 2021
22 Mar 2021
15 Mar 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab / Finolex / ALba / Anchor make laid in surface / recessed medium class PVC conduit, with modular switch , modular plate, suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. (Excl cost of conduit)
Wiring for 16 Amp Power Sockets with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable Polycab / Finolex / ALba / Anchor make laid in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required incl 15/16 Amp Modular Socket outlet with 15/16 Amp Modular Switch with indicator, GI box, modular plate and cover in front on surface or in recess, as required( Excl cost of conduit) ( One circuit is to be taken for two socket out lets )
Wiring for 6 Amp Power Sockets with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable Polycab / Finolex / ALba / Anchor make laid in surface/ recessed medium class PVC conduit along with 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required incl 2 no 5/6 Amp Modular Socket outlet controlled with 5/6 Amp Modular Switch with indicator, GI box, modular plate and cover in front on surface or in recess, as required( Excl cost of conduit) ( One Circuit is to be taken for four Socket outlets)
Supply, Installation, Testing and Commissioning of 22 watt Surface mounted LED Light fixtures of Philips / Crompton Greaves / Havells / Halonix make
Supply, Installation, Testing and Commissioning of 10 watt Surface mounted LED Light fixtures of Philips / Crompton Greaves / Havells / Halonix make
Supply, Installation, Testing and Commissioning of 4 feet long LED Tube Lights fittings of Philips / Crompton Greaves /Havells/ Halonix make.
Supply, Installation, Testing and Commissioning of 1400 mm Sweep Ceiling Fans incl its down rods complete of Crompton Greaves / Havells / Standard make.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supply, Installation, Testing and Commissioning of 300 mm Sweep Exhaust Fans of Crompton Greaves / Havells / Standard make as per site requirement incl refacing of walls.
Supply and Fixing of A C / D C
Supply and Fixing of Metre Plug and Socket DB`s with 32 Amp C Curve S Pole MCB`s of Legrand or its equivalent make
Supply, Installation, Testing and Commissioning of 40-63 Amp TPN MCB` incl its sheet steel enclosure fitted on Walls incl making of necessary connections and refacing of walls complete.
Supply, Installation, Testing and Commissioning of 8 Way IP 43 TPN Distribution Boxes with Metal Door Legrand / Hager / L&T / Schnedier / Eaton make having provision for FP MCB as incomer and SP MCB as out going recessed in walls incl refacing of Walls complete. ( excl cost of MCB`s)
Supplying and fixing 40-63 Amp four pole, 415 V, MCB "C" Curve in the existing MCB DB complete with connections, testing and commissioning etc. as required (Legrand / Hager / L&T / Schnedier / Eaton)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Legrand / Hager / L&T / Schnedier / Eaton)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (Incl cost of conduit)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire ( Lighting Circuits)
2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire ( AC Points)
4 x 16 sq mm + 2 x 16 sq mm as earth wire ( Heating Sub Main )
4 x 10 sq mm + 2 x 10 sq mm as earth wire ( Lighting Sub Main )
4 x 6 sq mm + 2 x 6 sq mm as earth wire ( Three Phase points )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Design, Fabrication, assembly, Installation, Testing and Commissioning of Front Operated out door type Cubicle type compartmentalised as per form 3B free standing, dust and vermin proof (IP 42 ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable , fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted ( metal based neoprene) and lockable doors having structural reinforcement with suitable angle/ channel/T / Flat section incl gland plates as required and lifting hooks with sleeved TPN AL Busbars and G I strip of required size with 2 no earthing terminals complete with interconnections as required for MCB`s and control wiring. Incomer :- 1 No 400 Amp TPN MCCB with breaking capacity 36kA with thermal release and adjustable settings. ( Legrand / Hager / L&T / Schneider / Eaton ) 1 no 160 Amp TPN Change over switch of standard make Out Going :- 1 No 250 Amp TPN MCCB With 36 ka breaking capacity ( Legrand / Hager / L&T / Schneider / Eatron ) 1 No 160 Amp TPN MCCB With 25 kA breaking capacity ( Legrand / Hager / L&T / Schneider / Eaton ) 14 No 40-63 Amp TPN MCB with 10 kA breaking capacity ( Legrand / Hager / L&T / Schneider / Eaton )
Providing of chemical earthing with 2 mts long and 50 mm dia fitted with G I Electrode place vertical in 100 mm bore drilled with hand drill and filled with one bag of Chemical, Extending of Earthing from G I electrode to DB`s With 12 mm width G I strip and Man hole cover at Top complete job.
Supply, installation, testing and commissioning of 3 Phase oil cooled 50 KVA Unbalanced Servo Controlled Voltage Stabilizer of ALBA / Chinar make with input of 210 to 460 Volts and out put of 440+/- 5% volts with over voltage and under voltage protection and with TDR incl its Relays, and filling of fresh filtered transformer oil complete. The job includes cost of required size of Copper multi strand Cables laid through PVC flexible Conduit for making Connections with input and out put in L T panel (One year guarantee is to be given by the supplier against any manufacturing defect with free service with in one year.
Supply, laying, Connecting and Commissioning of 185 sq mm 3.5 core XLPE/PVC insulated and steel armoured 1.1 KV grade Al Cable of Hovels / Polycab / Paramount make laid as per site condition from L T panel to L T Pole
Supplying and fixing of following modular Telephone Socket ( RJ11) incl its modular plate, Cover Plate and G I box complete
SITC Telephone apparatus Hand Sets with Called ID of Panasonic / Siemens make
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required ( 2 Pair )
SITC 20 Pair MDF ( Krone Type).
Supply, Installation, Testing and Commissioning of IP EPABX with 6 P&T lines, 2 Digital Extensions & 16 Analog Extension of Panasonic / Siemens make.
Supply and Fixing of modular type information out let RJ-45 CAT 6 Data, front plate and suitable size metal box on surface or in recess including connections etc complete as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable laid through PVC conduit ( Excl cost of conduit ).
Supply, installation, testing and commissioning of D Link Make 48 port 10/100/1000Base-T ports + 4 100/1000 SFP ports managed Web Smart Gigabit Switch Advanced L2 switching and security features , switching capacity 104 Gbps, CPU speed 700 MHz, VLAN Groups, Flash memory size 32 MB, MAC address size table 16K, LBD, port based band width control including supply and installation of 24 U rack fully loaded. The job includes connecting all out going and incoming Cables in the switch complete. The Job also includes Warranty For First One Years and AMC for Next Two years after commissioning of the Scheme.
M/S MUKHDOOMI ELECTRICALS
M/S PEARL ENTERPRISES
M/S NEW BHAT ELECTRICALS
M/S PARRAY ELECTRICALS
M/s SUN SHINE ELECTRICALS
M/S SHAH ELECTRICALS and MECHANICAL WORKS
Elevees Infrastructure Private Limited
JUNAID ELECTRICAL AND ELECTRONICS
M/S MIR ELECTRIC AND ELECTRONIC WORK
stage.html
html • 0.03 MB
finance_231435.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .