Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.1 L+₹3.7 L (13.6%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹32.4 L+₹5.0 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹33.3 L+₹5.9 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹33.7 L+₹6.3 L (22.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹51,333
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
PROVISION OF CERTAIN MINOR AND MAJOR REVENUE WORKS AT TECH AREA OF AF STN BHISIANA
2024_MES_661853_1
GE/BHI/MR-01/2024-25
Open Tender
Civil Works
Item Rate
183 days
GE (AF) BHISIANA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) BHISIANA
₹51,333
Yes
2 Sept 2024
25 Jun 2024
18 Jul 2024
25 Jun 2024
16 Jul 2024
9 Jul 2024
25 Jun 2024 - 1 Jul 2024
Amount
34W/MR-01/2022-23 (B/R PORTION)
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out (Soft/loose soil), complete all as specified and directed by Engineer in Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil, complete all as specified and directed by Engineer in Charge.
Add to srl item no 1.02 for each additional 1.5m or part thereof in depth beyond the first 1.5 m, complete all as specified and directed by Engineer in Charge.
Returning, filling in spreading and levelling and well ramming in layers not exc 25 cm thick including watering for filling complete all as specified and directed by Engineer in Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer in Charge.
M&L for hard core of broken bricks of gauge not exc 63mm, deposited, spread and level in layers not exc 15cm thick watered and rammed to a true surface complete all as specified and directed by Engineer in Charge.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified and directed by Engineer in Charge.
M&L for PCC 1:4:8 Type D2 (40mm graded stone aggregare) in foundations, filling and mass concrete complete all as specified and directed.
M&L 75mm thick PCC 1:2:4 type B-1 as in plinth protection finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for reinforeced cement concrete M-25 ( 20mm graded aggregate ) design mix concrete as in foundations, including rafts footings, foundation beams, plinth beam and mass concrete complete.
M&L for reinforced cement concrete M-25 (20 mm graded aggregate) design mix concrete as in columns, pillars, posts and struts etc complete.
M&L for RCC M-25 design Mix using 20mm graded aggregate in slabs supported on wall and beams and column in floors,roofs landing etc
M&L for RCC M-25 Design Mix using 20mm graded aggregate in chajjas,parapet facia etc complete all as specified and as directed.
M&L for RCC M-25 Design Mix using 20mm graded aggregate in beam,cantilevers,bressmers,lintel over 1.5 m span complete all as specified and as directed.
M&L for Brick work with sub class ‘B’ brick, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for Brick work with sub class ‘B’ brick, straight or curved on any plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and as directed.
M&L Formwork to sides of concrete foundations, footing bases,plinth beams and similar works for rough finished surfaces complete all as specified and as directed
M&L Formwork to sides of concrete columns and similar works for rough finished surfaces complete all as specified and as directed
M&L Formwork to sides and soffits of concrete floor/roof beams/ lintels and similar works for rough finished surfaces complete all as specified and as directed
M&L Formwork to soffits of suspended roof slab and similar works for rough finished surfaces complete all as specified and as directed
M&L Formwork to sides and soffits of concrete chajjas and similar works for rough finished surfaces complete all as specified and as directed
M&L for use & waste for form work to edges of concrete flat, treads breaks in floor, window cills, concrete railings, openings in concrete walls, floor and roof and similar work exc 10 cm but not exc 20 cm wide complete all as specified and directed.
M&L TMT bars 10mm dia and over, cut to length, bent to shape as required incl cracking bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
S&F MS TMT bars 6 to 8 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, quality conforming to IS 1786 - 1985 complete.
All as per itme No 1.27 here in before but 5 mm dia and over upto and including 10 mm dia ,stirrups inserting, spacers and binders complete all as specified and as directed
M&L 40 mm thick damp proof course to horizontal or vertical surfaces incl necessary form work in cement concrete 1:2:4 type B0(using 12.5mm graded stone agg) complete all as specified and as directed.
M&L 75 mm thick Cement concrete 1:4:8 Type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed
M&L Rendering 12mm thick in Cement Mortar 1:6 on fair faces of Brick Walls or on Concrete Surfaces, finished Even and Smooth,without using extra cement complete all as specified and as directed
M&L Rendering 15mm thick in Cement Mortar 1:4 on Fair Faces of Brick Walls or on Concrete Surfaces plastered Surfaces Finished Even and Smooth without using Extra Cement with WPC complete all as specified and as directed(WPC will be measured and paid separately)
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bedding layer in cement mortar 1:6 to receive tiles complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface such as skirting, dados and risers etc., 350x250x7 mm / 450x350x7mm thick including 10mm thick cement plaster in CM 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specifed and directed by Engineer in Charge.
M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper incl chalk whiting over a coat of wall care putty on plastered surface complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:3 on roof padding finished even and fair with approved water proofing compound @ 200ml per 50kg of cement or as per manufacturer's instruction all as specified and as directed.(Note : WPC shall be measured and paid separately as supply only under relevent item)
Supply only liquid water proofing compound complete all as specified and as directed
M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/sqm at bottom of the membrane as bonding material, complete as as per manufacture's instructions and directed by Engineer-in-Charge.
Preparing newly Plastered surface of ceiling and applying three coats white wash complete all as specified and as directed
M&L for Preparing Newly Plastered Surfaces of external walls or concrete surfaces and applying two Coats of all wheather exterior emulsion paint in camouflaging pattern as approved by station authority and RGB values variation from 100 to171 of approved pattern having percentage of colours 50%, 30%, 20% at a height n.exc. 25 mtr as per sample/pattern approved by GE complete all as specified and as directed by Engineer-in-Charge.
M&L for 25mm dia Mild Steel Curtain Rod, Powder Coated fixed with & Including MS Powder coated Hooks/ Brackets and decoratiove finishes (at both side), shades as approved by GE, complete al as specified including fixing of long size rawl plugs in wall with fixing brackets, stops, rollers etc. complete all as specified and as directed.
S & F of anodized aluminium snap grid of size 605 X 605 mm framework for false ceiling including necessary GI wire hangers 6 mm dia for securing frame work to ceiling , and also including necessary notching and prepared holes complete all as specified and directed.
S&f Providing and fixing Gypsum Board 12mm thick of size 600x600 mm in ceiling fixed with screw or supporting arrangements on snap grid as in ceiling as per manufacturers instructions or complete all as specified and directed
M&L powder coated Anodised aluminium frame(minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge.
S&F of Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples all complete as per requirement and direction of Engineerin-charge.
S&F of 12 mm Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work fixed with screw to aluminium frame or shutter any thickness complete all as specified.
supply and fix sheet glass ordinary quality 4.0 mm thick in square not exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame and wooden beading in aluminium frame complete all as specified.
M&L for 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub base complete all as specified and directed by Engineer in Charge.
S&F of 150mm long aluminium anodized barrel tower bolts of extruded section all complete as per requirement and direction of Engineerin-charge.
M&L for 5mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces in ceiling and finishing the surface even and smooth (without using extra cement) etc complete all as specified and directed by Engineer in Charge.
S&F of Door closer hydraulically of aluminium extruded section body regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engineer in Charge.
S&f of mild steel Mortice lock, vertical type, size 100 mm 2 levers for aluminium doors complete with handle.
S&f of 150 mm Extruded aluminium alloy handles, fabricated type, anodised fixed complete all specified and directed.
S&F of 18/19 mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S & F Continuous (piano) hinges, width of flaps 30mm ( when open), mild steel, bright finish or electrogalvanised all complete as per requirement and direction of Engineerin-charge.
S&F of two levers brass Locks, drawer, grade I, size 50 mm all complete as per requirement and direction of Engineerin-charge.
S&f of 100 mm Extruded aluminium alloy handles, fabricated type, anodised fixed complete all specified and directed.
M&L for Factory made single extruded WPC ) Wood Polymer Composite) solid door/window/ceosetory windows & other Frames/ Chowkat of size 45x70mm comprisisng of virgin PVC polymer of K value 58-60 (suspension Grade), Calcium carbonate and natural fibers (wood Powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of of 750kg/cum, screw withdrawal strength of 2200N (face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of glass A category with property of being termite/borer proof water/ moisture proof and fire retardant and fixed positions with MS hold fast'lugs/SS dash fasteners of required dia and length complete as per directios of Engineer-in-Charge. (M.S hold hold fast/lugs or SS dash fasteners shall be paid for separately)
34W/MR-01/2022-23 (E/M PORTION)
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 4.0 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type IP 43, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes, complete all as specified and directed by Engineer in Charge.
M&L for Galvanized steel tubing 40 mm light garde for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Excavation in trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 metre and depositing where directed at a level not exc. 1.50 metre above the starting point, complete all as specified and as directed.
S&F Single Pole & Neutral Enclosure with a two pin and Earth Plug and socket 240 volt including one single pole MCB of 20 Amp, complete all as specified and directed by Engineer in charge.
S&F Sub-main Wiring (Surface/ Concealed) with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in medium grade PVC CONDUIT/PVC CASING & CAPING, complete all as specified and as directed by Engineer in Charge. Note: (a) 3 Runs of 6 sqmm Copper Wire & 1 Runs of PVC conduit shall be measured as single unit. (b) The disturbed surface of wall for surface box wiring shall be make good by applying cement plaster, putty and colour wash etc to match with the existing surfaces. (c)The quoted unit rate shall include Cuting chases for conduits and sinking's for boxes.
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps including 1 No MCB SPN 06 Amps on suitable foundation and Cable entries should be in proper Metalic glands only.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and directed by Engr-in-Charge NOTE : For Purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed by Engr-in-Charge
Supply and install Voltage stablizer copper winding automatic digital type operation single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stablized at 230 Volt with accuracy of (+/-) 2.5 percent of capacity 4 KVA, complete all as specified and as directed by Engineer in Charge.
Supply and install invertor based split AC with cordless remote of capacity 1.5 TON (Copper coil Both in door & out door Unit with inbuilt air ioniser and plasma filter) electric driven single phase, 230 volts, New 5 star rating EER 3.2 including all accessories like brackets, rubber tubing, copper tubing as required at site, gas charging, with auto filter clean technology etc including testing and commission with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed. Note : All cooling /condensing coil should be copper material.
M&L for concealed Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
All as per Item No 1.75 for One 3 Pin Switch socket Combination 6 amp on the independent board.
All as per Item No 1.75 for One 3 Pin swich socket Combination 6 amp on the same board with other switches.
M&L for concealed Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and complete all as specified and as directed.
S&F 1X18 watt incl taking down wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
S&F Ceiling Fan AC Single Phase Metalic Body 230V of size 1200n sweep, including of making holes etc, complete all as specified and directed by Engineer in Charge.
S&F MCB Single Pole & Neutral, 40 Amp, 240 /415 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
S&F MCB Single Pole 6 to 32 Amp, 240 /415 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
M&L Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR Part-I and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed by Engineer in Charge.
34W/MR/01/2023-24 (BHISIANA)
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out soft/loose soil, complete all as specified and as directed by Engr-in-Charge
M&L for PCC 1:4:8 Type D2 (40mm graded stone aggregare) in foundations, filling and mass concrete complete all as specified and as directed by Engr-in-Charge
M&L for Formwork to sides flat rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge
M&L for Formwork to sides of rough finished surfaces of square concrete columns complete all as specified and as directed by Engr-in-Charge
M&L for RCC (nominal mix) type B1 1:2:4 (20mm graded aggregate) in foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for RCC (nominal mix) type B1 1:2:4 (20mm graded aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. complete all as specified and directed by Engr-in-Charge
Returning, filling , including spreading, levelling, watering and well ramming in layers not exc 25 cm.of soft/loose soil.
Removing excavated soils exceeding 1.5 Km but not exc. 5 Km and depositing where directed by Engr-in-Charge
S&F Rolled sections as in post, main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates confirming to Fe-410W (GdeE-250) quality A complete all as specified and directed by Engr-in-Charge
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc complete all as specified and directed by Engr-in-Charge
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc complete all as specified and directed by Engr-in-Charge
S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 50cm long of dia neck exc 12mm n exc 20mm complete all as specified and directed by Engr-in-Charge
Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of olive green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of olive green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. all as specified and directed by Engr-in-Charge.
M&L for 40 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) laid in alternate panel in floorings including finishing the surface even and smooth without using extra cement. complete all as specified and directed by Engr-in-Charge.
Supply only Glass dividing strips,3 mm thick and 38mm width inserted in position confirm to design or directed by Engr-in-Charge
M&L for 75 mm thick Cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) in sub base of flooring, hard standing, plinth protection etc complete all as specified and directed by Engr-in-Charge
34W/MW/03/2023-24 (B/R PORTION)
Supply and grouting mild steel pre-painted rifle rack for 4 capacity (two for each side) of rifle ’s of standard size olive green as standard colour (applying two coats of synthetic enamel paint over one coat of ESDEE make primer and one coat of ESDEE make surfacer) with 2mm HRC sheet, size of angle 35x35x5mm for main frame and 25x25x5mm for moving slide, 60 to 65mm wood pallet, size of 330x150x180mm aluminium box, mild steel base frame, powered with adjustable drive movement with nut and bolt, PVC U shaped anti scratch pads for but and PVC tape for barrel and trigger area and butt will be hold on high quality mild steel single tier type having MS Iron base to hold all rifle, thrust bearing moving in smooth end by use of twin bearing, collapsible suspension lever for anti break locking with special rust proof treatment with apply before paint and theft proof 3 step Harrison make ISI marked locking device with two keys. Note : The quoted rate includes the demolition of any type of floor for grouting the rifle rack and finishing the surface smooth with PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate.
34W/MW/03/2023-24 (E/M PORTION)
M&L for Concealed Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
All as per Item No 3.03 for One 3 Pin Switch socket Combination 6 amp on the independent board, complete all as specified and directed by Engineeer in Charge.
All as per Item No 3.03 for One 3 Pin swich socket Combination 6 amp on the same board with other switches, complete all as specified and directed by Engineeer in Charge.
M&L for concealed Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for 16 AMP MULTI PURPOSE SOCKET COMBINATION POINT ON INDEPENDENT BOARD, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and complete all as specified and as directed.
S&F 1X9/10 watt wall mounted, new generation LED batten for multipurpose application, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
34W/MW/01/2024-25 (E/M PORTION)
Supply, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sqmm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
Supply, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
Excavation in trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 metre and depositing where directed at a level not exc. 1.50 metre above the starting point, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and directed by Engr-in-Charge NOTE : For Purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed by Engr-in-Charge
S&F Factory made Sheet Metal Enclosure of 2.00mm thick sheet of outdoor type platform or wall mounted including three phase aluminium bus bar of rating 200 amps, complete all as specified and directed by Engineer in Charge.
S&F Factory made Sheet Metal Enclosure of 2.00mm thick sheet of outdoor type platform or wall mounted including three phase aluminium bus bar of rating 200 amps with MCCB 4 Pole 100 Amp, complete all as specified and directed by Engineer in Charge.
M/s Luxmi Constructions
STELLAR PROJECTS
SHAKTI SINGH CONTRACTOR
GUPTA AND ENGINEERS
M/s BALDEV SINGH
PREM ENTERPRISES
Rasvinderpalandco
KAY VEE CONSTRUCTIONS
M/s Kamal Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .