| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹38.8 L+₹1.2 L (3.30%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹40.8 L+₹3.3 L (8.85%)Rejected-Finance 763 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UTTAR PRADESH | 284401 | L3 | Rejected-Finance Other than
lowest
bidder | |
| 4 | L4₹42.1 L+₹4.6 L (12.3%)Rejected-Finance 1010 NANDANPURA BABINA CANTT DIST JHANSI 284401 | BABINA CANTT | JHANSI | UTTAR PRADESH | 284401 | L4 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
14 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
REPAIR TO ROOF TREATEMENT IN OTM AND MD ACCN AT AGE B/R-II UNDER GE BABINA CANTT
2022_MES_569811_1
8095/E8
Open Tender
Civil Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹98,000
Yes
3 Feb 2023
17 Dec 2022
16 Jan 2023
17 Dec 2022
14 Jan 2023
31 Dec 2022
Amount
Demolition of Brickwork or stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articlesl etc complete all as specified and as directed.
M & L for brick work with sub class B brick old size straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of RCC water storage tank of size exc. 600x1200x1000 mm but n.exc 1200x1600x1500mm on roof, floor, staging complete and the scrap should be removing to distance of 50m where directed by EIC complete all as specified and directed.
M&L for repeairing of RCC projection, Chajjas, columns, beams, Parapet wall etc. by necessary preparation i.e scraping, cutting, chiseling, dusting and cleaning exposed reinforcement surfaces of damaged/ loose surface and applying one coat of cement slurry and filling the surface with plain cement concrete (1:1.5:3), reinforced with welded mesh and make good by 15mm thick plaster with cm (1:4) and item including scaffolding/ formwork etc upto triple story height complete all as specified and directed by Engr-In-charge.
Removal of plant/ treas/ Shrubs from roof tops/ sides, external walls of bldg, chajjas, wall junctions, junctions of rain water pipe/ CI soil/ waste pipe junctions including taking out the roots entered in wall/ slab surfaces and making good the disturbed surfaced using PCC (1:2:4) type B-0 or cement morter (1:2) including repairing the GI/CI/PVC pipe joint which were damaged during cutting/ taking out process to match with the existing and finishing the disturbed surfaces to match with existing including necessary scaffolding/ staging and formwork upto a height of 10.00 m from the ground level complete all as specified.
Taking down cement plaster of any description built in cement mortar on brick or stone walls or concrete surfaces etc including racking out joints, hacking for Key, scrubbing down with water etc.complete all as specified and directed.
M&L renderig/screeding 15mm thick cment mortar 1:4 on fair faces of brick or concrete surface of wall rendering is to be finished even smooth with out using extra cement complete all as directed by the Engineer - In- Charge.
M&L for a coat of JK/Birla wall care putty 1mm thick including prepration of surface complete all as specified and as directed.
M&L for preparation old treated surface of wall and applying one coat of cement base paint with roller complete all as specified and directed.
Demolition of RCC Parapet, Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work is reinforced (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20 mm graded aggregates) for Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed.
M & L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase ailings and similar work including attached pillasters, buttresses, etc., vertical or to batter complete all as specified and directed.
M&L TMT bars 10 mm dia and over cut to length, bent to shape required incl bending spirally for hoping for columns, beams etc hooking ends and embeded on concrete surfaces or welded on semilar work and bindind with MS wire (annealed) not less than 0.9mm dia quality confirming to relevent IS complete all as specified and directed.
M&L TMT bars 8 mm dia cut to length, bent to shape required incl cranking, bending spirally for hopping for columns hooking ends and binding with MS wire (annealed) not less than 0.9mm dia quality confirming to relevent IS complete all as specified and directed.
Demolition of PCC/lime terracing of any description and in any position as in roof terracing complete all as specified and places where directed by Engineer-in-Charge/GE.
M&L plain cement concrete 1:2:4 type B0 using 12.5mm graded aggregate as in padding over roof finished and laid to required slop complete all as specified and directed by the Engineer -In-Charge at site complete all as specified and directed.
M & L cutting out cracks to ‘V’ section in existing roof or terracing, cleaning out, wetting and filling solidly a hot mixture of bitumen and dry sand in proportion of 1:1 by weight complete all as specified and as directed
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed.
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is green finished even and fair including mixing of water proofing compound as per manufacturer instruction complete all as specified and as directed. Note :- Water proofing compound shall be measured and paid separately)
Supply only water proofing compound complete all as specified and as directed.
M&L applying water proofing treatment with the following :- (a) One coat of bitumen primer conforming to IS-3384 @ 0.4Kg / sqm (b) A layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
M&L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finish complete all as specified and directed
M&L machine pressed cement concrete tiles 25cmx25cmx22 mm thick set and jointed and pointed in neat cement slurry in floors and pointed with grey cement and no pigment complete all as specified and directed
M&L for preparing of APP membrane surfcases of any description, not otherwise described and applying two coats of synthetic Aluminium paint on APP membrane surface on roof top complete all as specified.
S&F 500 ltr capacity or rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) ISI marked or make specified, two layered construction hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia gi pipe medium grade overflow pipe 600mm long with fitting including taking down of exisiting unserviceable tank complete all as specified in SSR Part -I complete all as specified and as directed
S&F 1000 ltr capacity or rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) ISI marked or make specified, two layered construction hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia gi pipe medium grade overflow pipe 600mm long with fitting including taking down of exisiting unserviceable tank complete all as specified in SSR Part -I complete all as specified and as directed
Disconnecting of existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, capacity exe 250 lts but nexe 500 ltrs capacity complete all as specified and as directed
Disconnecting of existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, capacity exe 500 lts but nexe 1000 ltrs complete all as specified and as directed
S & F in repair 15mm bore dia ball valve high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed in newly taken tank (minimum weight 15mm - 142 gms) complete all as specified and as directed
Supply only 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. .(Minimum weight 20mm-210 gms complete all as specified.
S& F in repair 25mm bore dia ball valve high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed in newly taken tank (minimum weight 25mm - 225 gms) complete all as specified
Taking up or down existing 15mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and as directed
Taking up or down existing 20mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and as directed
Supplying, fixing, jointing and testing 15mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed
Supplying, fixing, jointing and testing 20mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed
Dismantling AC /CGI /PGI sheet roofing with ridge (corugated or semi corrugated) complete all as specified and as directed
S&F Pre-painted galvatume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and as directed
S&F Pre-painted galvatume aluminium zink coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and as directed
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe-290 Gde E-165 complete all as specified and as directed.
M&L for two cote of synthetic enamel paint over redoxide primer on new steel Surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pump, insulation etc,) or insulation boards of any thickness including cover fillets.
M&L for aluminium anodised snap grid frame work of the following (a) Main Tee section 36.5x25x1.4mm size (wt not less than 0.24Kg/RM) (b) Section alongwith wall angle of size 40x25x2mm size (wt not less than 0.36Kg/RM) (c) Cross Tee section 23.5x26.4x1.4mm size (wt not less than 0.191Kg/RM) (d) Snap grid shall be fixed to G.I Flat 40 x 3mm supporting hangers consisting of 4mm dia G.I rod n.exc 1.20m length with J bolts nuts and washer etc as per manufacture instructions & complete all as directed.
M&L for 4mm thick high pressure steam cured non asbestos fiber cement design board of size 600mm x 600mm as in ceiling complete all as specified and directed.
Demolition of cement concrete (unreinfored )in ground floor and paving n,exc 15cm thickness below or above ground level)complete all as specified and as directed
M&L for PCC 1:4:8 type D2 using 40mm graded stone agg as in filling and mass concrete, Sub base/flooring complete all as specified and directed.
M&L 100 mm thick cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in floor, sub floor and pavings etc. complete all as specified and as directed
M&L 40 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in floor complete all as specified and as directed
M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound with Grade - A all as specified and directed.
M&L for machine pressed precast concept interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment over 5 mm thick sand bed over 100mm thick PCC type D2 1:4:8 (40mm graded aggregate) complete all as specified and as directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints fixed to walls and taking down old PVC /CI/Concrete pipe complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints fixed to walls and taking down old PVC /CI/Concrete pipe complete all as specified and as directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and as directed.
M/s Ravi Traders
Ms Vinay constructions
M/S M S Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .