| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹48.2 LAccepted-AOC | ₹48.2 L Quoted ₹48.5 L | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹49.6 L+₹1.1 L (2.24%)Rejected-Finance | ₹49.6 L+₹1.1 L (2.24%) | 2 | Rejected-Finance Not being the lowest bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not enlisted appropriate category |
| 4 | Rejected-Technical NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | - | - | Rejected-Technical Not enlisted appropriate category |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not enlisted appropriate category |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Oct 2023, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE I RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
COMPREHENSIVE MAINTENANCE OF LIFTS INCLUDING REPAIRS TO LIFTS AND SENSOR DOORS AT RCI ELSEC UNDER GE I RND RCI HYDERABAD
2023_MES_619768_1
8876
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE(I) R AND D RCI
MES enlisted Class D category c ii and d v and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹98,000
Yes
15 Nov 2023
20 Sept 2023
13 Oct 2023
20 Sept 2023
11 Oct 2023
4 Oct 2023
Amount
Comprehensive maintenance for the following capacities of Lifts located at various buildings as detailed below:- (a) ELSEC : KONE make - 1Ton - 1 No. (b) DOFI : KONE make - 1 Ton - 01 No. (c) Microwave/Auxiliary Tower: OMEGA make -0.68 Ton- 02 No. (d) RSL : OMEGA make - 1 Ton - 01 No. (e) DOPSS : OTIS Make - 1Ton - 01 No. (f) R & QA Lab : OTIS Make - 1 Ton - 01 No. (g) AVC : EXCEL make - 408 Kg - 01 No. (h) CSL : JOHNSON make - 1 Ton - 01 No.
Notes for the Serial item No 1: All T&P required for repair and maintenance are deemed to be included in the unit rates quoted.
Supply and fix all types of minor spare parts of value not more than Rs 500.00 per month shall be deemed to be included in the quoted rate.
The comprehensive maintenance shall be got carried out by Original Equipment Manufacturer (OEM) only for which necessary agreement copy between contractor and OEM shall be submitted to this office for the above lifts.
All break downs and repairs shall be attended by OEM only on as requirement basis within a reasonable time all as directed by the Engineer-in-charge. Monthly Inspection of lifts shall be carried out by the OEM. All safety tests shall be carried out by OEM and report shall be submitted to the Engineer-in-Charge.
The replacement of spares/parts will be measured and paid for separately under relevant items of BOQ. Labour elements for fixing of spares/parts mentioned in this Schedule/BOQ as 'Supply Only' shall be deemed to include in the unit rate quoted.
Periodical maintenance as per check list for monthly inspection shall be submitted by contractor.
Contractor/ OEM has deemed to have visited the site and known to have complete knowledge/information about the lifts and all other relevant factors as existed at site before quoting the tender.
Lift inspection shall carried out by Govt approved Lift Inspector once in 06 months, twice during the contract period. First one at commencement and the second one at middle of the contract period all as directed by the Engineer-in-charge. All documents shall be submitted to Engineer in charge and unit rate quoted shall be deemed to include for the same.
Contractor has to employ a properly qualified supervisor cum mechanic at site during maintenance and has to tie up with Lift Inspector for smooth functioning of all above lifts.
Periodical maintenance as per check list for monthly inspection shall be submitted by contractor.
SUPPLY ONLY Control maintenance contactors of 110V capacity. Make: L&T/ GE/SIEMENS
SUPPLY ONLY Break shoe suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY levelling switches suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Relay Board suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Door Sensor (Full size length) suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Limit Switch safety mechanical suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Door Closer and door opener suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Direction Read switch sensors suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Door limit switch suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Control Transformer suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Door Wheel suitable for lifts listed under Serial item No. 1.
SUPPLY ONLY Lift Cabin fan of size 300mm of approved make and model complete all as directed. MAKE: CROMPTON GREAVES/KHAITAN/HAVELLS/ BAJAJ
S&F 10 Watt LED recessed mounted down lighter with pressure die cast aluminium heat sink and polycarbonate diffuser in white powder coated finish with integrated driver including taking down old unserviceable one complete all as specified and directed. MAKE: HAVELLS/CROMPTON GREAVES/PHILIPS/ WIPRO
SUPPLY ONLY Magnet switch suitable for lifts listed under Serial item No. 1 above.
SUPPLY ONLY Shoe gibs suitable for lifts listed under Serial item No. 1 above.
Supply and Fill Gear Oil of grade 320 in Lift Gear Box complete all as specified and directed. MAKE: CASTROL/SERVO/GULF WESTERN OIL/IOCL/ HPCL/ BPL
S&F Variable Voltage & Variable Frequency (VVVF) Drive suitable for microprocessor controller system with all accessories suitable for 10 to 15 HP capacity including testing and removing old unserviceable one complete all as specified and directed. MAKE: YASAKAWA/TOSHIBA
S&F fine quality of water proof and shock proof PVC/Rubber Mat of suitable size for any make/capactiy of lifts
Disconnecting and removing the unserviceable ARD (Automatic Rescue Device) from OTIS make Lift with battery bank, supply and fix new ARD 8.5 to 11 MOT KW W/BAT, ARD Announcer W/Accessories, CIMR-LT4A0031FACw/PGB3&JVOP, wiring kit material for G5-L7, capacitor with Harness, Encoder, fuse cover, L 1000 Driver MTG Platt-7.5-15KWLCB along with 20 mm dia flixible PVC Conduit etc., of each one number suitable for up to 1 Ton goods lift and testing all as specified and as directed. MAKE: OTIS
Disconnecting and removing the unserviceable Rectifier Board, Sensor Board, Power Board with complete battery bank, supply and fix Rectifier Board, power board with battery bank comprising of 8 battaries of 12 V, 17AH complete suitable for 1 Ton goods lift of any make/model and testing all as specified and directed. MAKE: KONE/OMEGA/OTIS
S&F Door Module, FERMATOR DOOR VF5+ with extension cable and all accessories of suitable capacity and with necessary wiring and testing including removing old unserviceable one complete all as specified and as directed. MAKE: KONE/OTIS/OMEGA
S&F Curtain of light-154beams and LCECCB assembly with all accessories of suitable capacity with necessary wiring and testing including removing old unserviceable one complete all as specified and as directed. MAKE: KONE/OTIS/OMEGA
Disconnecting and removing unserveable Car opertaing panel, supply and fix new car opertaing panel complete all as specified and directed. MAKE: KONE/OTIS/OMEGA
S&F Mother Board compatible for 01 Ton goods lift at lift main panel including removing old unserviceable one complete all as specified and as directed. MAKE: KONE/OTIS/OMEGA
SUPPLY ONLY cabin push button box with push buttons for lifts.
Disconnecting and removing burntout 1HP motor from its location, rewinding the motor with same gauge/ size of super enamelled copper conductor with same number of turns, varnishing, insulating to the required standards, oven drying and refixing back in original position and testing complete all as specified and as directed.
S&F MCCB, 4 pole, 100 Amps, 36KA rupturing capacity, 415 Volts with thermal magnetic release with provision of copper cable/extended terminals from MCCBs to busbar and connection of LT cables with MCCB with suitable size aluminium lugs including removing old unserviceable one complete all as specified and as directed. MAKE: LEGRAND/ L&T/ SIEMENS/INDO ASIAN
S&F MCCB, 4 pole, 63 Amps, 36KA rupturing capacity, 415 Volts with thermal magnetic release with provision of copper cable/extended terminals from MCCBs to busbar and connection of LT cables with MCCB with suitable size aluminium lugs including removing old unserviceable one complete all as specified and as directed. MAKE: LEGRAND/ L&T/ SIEMENS/INDO ASIAN
SUPPLY ONLY 12 Volts Battery, 12AH to 17AH for lifts. MAKE: EXIDE/AMARON/SF
Disconnecting old/unserviceable wiring, M&L for additional wiring suitable for 1 Ton goods lift and make/model for interfacing with main controller complete and testing all as specified and directed.
Outsourcing of services for operation of One No. of Lift at AVC (Director Building) and One No. of Lift at ELSEC of any make and capacity by providing Two Lift operators per shift of 8 hours for One shift in a day on all days excluding Sundays and Holidays complete all as specified and directed.
Notes for the Serial item No. 32 All stationary for Duty Roster, Attendance register, Wages register, Log sheet book, maintenance record etc., shall be arranged, maintained and submitted by the contractor to Engineer in charge in the first week of every month.
Any loss due to negligence, faulty operation shall be made good by the contractor without any extra cost to the department.
Wage period shall not exceed one month. Wages for all workers employed shall be paid before 7th day of every month through bank account without fail irrespective of whether RAR is claimed or not.
Minimum wages, EPF, ESI, Bonus etc., to the workers shall be paid by the contractor as per Regional Labour/PF Commissioner, Gazette Notification including DA all as authorized.
Non compliance on part of the contractor for not making payment of wages to workers as stipulated above shall attract penalty at the rate of Rs.100.00 per shift per worker from RAR/Final bill. No claim whatsoever on this account will be entertained.
ELEVATORS MAINTENANCE ENGINEER WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .