Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Found lowest and reasonable and accepted | |
| 2 | L2₹15.2 L+₹84,542.70 (5.87%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹15.9 L+₹1.5 L (10.4%)Rejected-Finance RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹17.2 L+₹2.8 L (19.4%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹17.3 L+₹2.9 L (19.9%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
8 Jul 2024, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
REPAIR/MAINT TO LED STREET LIGHTS ALONG WITH REPLACEMENT OF LT DAMAGED CABLE INCLUDING ALLIED ITEMS AND UPGRADATION OF STREET LIGHT SYSTEM IN BHAGAT LINE AREA UNDER AGE E/M (ES) MEERUT CANTT
2024_MES_658859_1
8599/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
₹46,000
Yes
19 Nov 2024
10 Jun 2024
15 Jul 2024
10 Jun 2024
8 Jul 2024
24 Jun 2024
Amount
Preventing/servicing unserviceable LED Street light/flood light fitting, 45 to 210 watts any type from pole/wall to checking out serviceability of parts/circuit such as drivers,PCB etc if necessary taking down the fittings and replaced/repair of unserviceable parts,including soldering with existing circuit board, replacing with new of aluminium wire of 1.5 Sqmm 3 core upto 1.5 mtr and reassembling and refixing in same position including connecting, testing complete all as specified and directed. NOTE :-drivers shall be measured and paid seperately as supply only.
S&F in replacement of existing unsv street light fittings with LED new generation energy saving and environmental friendly long life LED street light fitting 50 Watts, IP 65 protection , having pressure die cast aluminium housing with polycarbonate lens,better optics for uniform distribution, toughned glass and Driver shall be IP-67 for water protection, including surge protection device 8 Kv.External dusk to dawn sensor is optional. including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 Sqmm complete all as specified and directed.
S&F in for replacement of existing unsv street light fittings with LED new generation energy saving and environmental friendly long life LED street light fitting 70/72 Watts, IP 65 protection , having pressure die cast aluminium housing withpolycarbonate lens,better optics for uniform distribution, toughned glass and Driver shall be IP-67 for water protection, including surge protection device 8 Kv.External dusk to dawn sensor is optional. including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 Sqmm complete all as specified and directed.
S&F in replacement UNSV GI bracket made out of GI pipe 40 mm bore medium grade bent to required shape of 1.5 mtr long and fixing to pole/wall with suitable size of nut, bolts and clamps including taking down and refixing of street light complete all as specified and directed.
S&F in replacement of existing unsv street light fittings with LED flood light fitting 150 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 Kv and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed.
S&F in replacement of highmast light luminate flood light, pressure die cast aluminium housing, IP-66 protection, 200 Watt/ 210 watt flood light with and including high power SMD LED lamps with inbuilt surge protection with SPD 10 KV and connecting with and including 2.5 Sqmm , 3 core copper conductor cable from box to connector of light fitting, complete all as specified and directed. Note:- The driver should be polted anti vibration type, IP 66 should be sustain 440 volts for 2- 4 hrs.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as specified and directed. Note :- Punned thickness shall be measured for payment.
M&L for fly ash old size bricks,straight or curved on plan,laid flat with width equal to length of brick,laid dry over electric cable for protection all as specified.
Supply and Laying in Replacment XLPE LT UG cable pvc insulated,bedded armoured heavy duty electric cable 1100volt grade with aluminium conductor of size of cable 25 Sqmm 4 Core complete all as spd and directed.
All as per Srl No 12 here-in-before but size of cable 16 Sqmm, 4 Core complete all as spd and directed.
All as per item No 12 here in before but size 10 Sqmm 4 core complete all as spd and directed.
All as per item No 12 here in before but size 10 Sqmm 2 core complete all as spd and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed . Make – Ravindra,Surya,Jindal.
M & L for prepration of old painted surface of steel tubular poles of 9 mtr long including cross arms , cable protection pipe , bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning /cutting the grass/bushes at a radius of 2 mtr surrounding the pole all as directed.
Supply and fixing in replacment of nature switch (using infrared sensor technology) based automatic street light control panel.The panel should be suitable enough to take three phase load of 8 KW, complete with timer , contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 PROTECTION CLASS 2. enclosure (Hensel) of three phase integrated models of capacity 8 KW complete all as specified and directed. Make : Cat Part No. SWADEEP-66- 8kW 3P of Healer Enterprises or equivalent as approved by GE
ditto but of single phase integrated models of cpacity 8 KW (Cat Part No. SWADEEP-66 5kW 1 P of Healer Enterprises or equivalent as approved by GE.
Supply and fixing thermoplastic polystyrene /polycarbonate enclosure bus bar chamber , shock proof , vermin proof and dust proof complete with 04 Nos aluminium strip of capacity 100 amps including non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed. Make:- Hensal/ Rittal/ ABB.
M & L for drilling suitable dia horizontal bore holes for insertion / laying of up to 50 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm, IP-55 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 200 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in PCC 1:2:4 type B1 of size 150mmx150mmx250mm , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double door and back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415V,36 KA,50 hz -01 No (incoming),suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable including taking down old u/s pennel board complete all as specified & directed.
M&L earthing complete with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 3.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised strip 25x4 mm size as earthing lead by means of bolts, nuts, check nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Supply only PCB suitable for 45 to 72 watt LED light fittings, 140V to 270V universal PCB with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65.
Supply only Driver suitable for 70/72/90/100 watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
S&F in repairs 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections to street light fittings complete all as specified and directed.
S & F MCB single pole 240 volts, 'c' curve of rating from 6 to 40 amps, with rupturing capacity 10 KA,including providing thimble for out going cables.
D S Enterprises (BID ID -3045678)
EX SOLDIERS MECHANICAL WORKS (BID ID -3045865)
Shikha Enterprises (BID ID -3045621)
PK ENTERPRISES (BID ID -3045743)
Ramesh Traders Govt Contractors & General OrderSuppliers (BID ID -3053511)
janta tradrers (BID ID -3046482)
Haryana EngineerService (BID ID -3051401)
automation and switchgear control (BID ID -3054050)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .