| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC Rates were reasonable and L1 Bidder |
| 2 | L2₹2.1 Cr+₹14.8 L (7.68%)Rejected-Finance | ₹2.1 Cr+₹14.8 L (7.68%) | L2 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 3 | L3₹2.1 Cr+₹18.0 L (9.33%)Rejected-Finance | ₹2.1 Cr+₹18.0 L (9.33%) | L3 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 4 | L4₹2.2 Cr+₹31.2 L (16.2%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹2.2 Cr+₹31.2 L (16.2%) | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹2.3 Cr
EMD Value
₹3.1 L
Closing Date
11 Nov 2021, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
AUGMENTATION OF EXTERNAL ELECTRIFICATION FOR CONVERSION OF LT/HT OH CONDUCTOR WITH UG CABLE AT JALAPAHAR UNDER AGE(I) DARJEELING
2021_MES_473439_2
CWE/136-WE/30 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
280 days
DARJEELING
Class B, Category b (ii)
8 documents required · 8 mandatory
₹2,000
Yes
AGE (I) DARJEELING
₹3.1 L
Yes
8 Dec 2021
6 Oct 2021
12 Nov 2021
6 Oct 2021
11 Nov 2021
28 Oct 2021
6 Oct 2021 - 11 Oct 2021
Amount
M & L for dismantling ACSR conductors complete all as directed .
M & L for dismantling Earth wire or copper conductor, service feeder or distributor span complete all as directed.
M & L for dismantling & taking down insulators any type and size complete all as directed.
M & L for dismantling & taking down cross arms or MS channel or angle section etc complete and diposited to MES store yard complete all as directed.
M & L for dismantling & taking down GOD of any type and specification complete all as directed.
M & L for dismantling & taking out HT steel tubular poles complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5mtr in depth for foundation. (Laying of under ground cables) in soft/loose soil and getting out all as directed.
Excavation in trenches exceeding 1.5 Mtr wide and not exceeding 3 mtr depth and getting out in hard/dense soil all as specified and directed..
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil all as directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point all as directed.
M&L for sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and punning to proper required cover all as directed.(Note:-Panned thicknes only measured and paid).
Supply and fix precast concrete cable cover , class , HV , Type I flat size 300 x 180 x 40 mm laid dry in trenches over under ground cables all as directed..
Supply and laying of fly ash bricks of best qualitylaid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning, for cable protection as directed.
Supply, Laying & testing cable XLPE insulated screened PVC beded, galvanized steel strip or round wire armoured, electric power cables (heavy duty earthed system), with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sqmm complete all as specified and directed.
Supply and fix cable end termination joint kit heat shrinkable outdoor termination type joint complete with jointing material and accessories suitable for 11KV 3 core 50 Sqmm to 95 Sqmm HT XLPE armoured UG cable (Earthed) complete all as specified and directed.
Supply and fix cable end termination joint kit heat shrinkable indoor termination type joint complete with jointing material and accessories suitable for 11KV 3 core 50 Saqmm to 95 Sqmm HT XLPE armoured UG cable (Earthed) complete all as specified and directed.
Supply and fix cable straight through joint kit heat shrinkable type joint complete with jointing material and accessories suitable for 11KV 3 core 50/70/95 Sqmm HT XLPE armoured UG cable (Earthed) complete all as specified and directed.
M & L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
M&L cross arms, bracings, supports clamps and back plates fabricated from structural steel sections, including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Supply & fixing steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-55 (11.00 Mtr) complete all as specified and directed.
Material and labour for mechanically gang operated air break switch 11KV mounted on 12 nos. insulator and steel frame with operating mechanism worked from ground level complete with drop out fuse (set of three) of rating 400 amps complete all as directed.
Supply, installation, testing and commissioning of copper wound step down (11/0.433KV) transformer outdoor type oil cooled with standard fittings three phase 4 wire with off load tappings on HT side to vary secondary voltage within limit all as per IS: 1180 Level 1 of capacity 315KVA complete as per following specification :(i) Dyn11 Connection (Vector Group) (ii) Off load tap changer 6 steps / 7 position with tapping Range- (+)5% to (-)10%@2.5 (iii) Total loss not exceeding 1.1KW at 50% load and 3.275 KW at 100% load (iv) 4.5% impedance at 75°C (v) Temp Rise (oil/Wdg.)- 40/45°C (vi) Standard fittings are stem type OTI, Explosion vent, Silica gel breather, oil level gauge, Roller, Earthing terminal, sampling valve, filter valve including first filling of transformer oil complete all as directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia medium grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 x 3.5 Core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3½ core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or round wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 30x30 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 15 cm from top using PCC 1:3:6 including removal of surplase soil complete all as directed.
Laying only GI Pipe for cable proction of 80 mm bore complete all as specified and directed.(Note:-GI pipe will be issued under Sch 'B' store).
Laying only GI Pipe for cable proction of 40 mm bore complete all as specified and directed.(Note:-GI pipe will be issued under Sch 'B' store).
M&L for pcc 1:2:4 type B-1 using 20 mm graded stone agrregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement all as directed .
M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate in foundations of poles,filling and mass concrete complete all as specified and directed.
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting all as directed.
S&F Pole box with suitable terminal connector for single/three phase connctions loop in and out 10 to 16 Sqmm 2/4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polysterene/polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, flame retradant glow wire test at min 75°C internally embeded gasket with provision for cable entry through IP 66/67 themoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm LBH), GI clamps made out of GI flat of size 25mm X 3 mm channel including making connections all as specified and directed. complete all as specified and directed. Make: Hensel Cat No.DK1616G or equivalent.
M&L for Stright through joint of size 240 Sqmm 3½ core regin cast complete heat shrinkable outdoor type LT PVC / XLPE cable upto 1.1 KV complete with all accessories and generally conforming to IS 8438/1977 Note: Excvation & Earth work shall be mesured & paid sepreately in respective item of this sch.
M&L for outdoor type Busbar Chamber fabricated by CRCA sheet 3.15mm and 60mmX60mmX6mm angle iron frame with front and back side opening with locking arrangement suitable for 600 Amps aluminium Busbar 415 Volts, 3 phase, 4 wire AC supply system mounted on DMC insulators of size 750mmX500mmX350mm , painted using powder coating technology complete all as specified and directed.
Note:- The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. GI pipe medium grade 40mm & 80mm dia shall be issued under Sch 'B' store.
KR POWER INFRA INDIA PVT LTD.
M/s BHAGWATI CONSTRUCTION
New Era Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .