Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC VALID | |
| 2 | L2₹17.3 L+₹54,391.50 (3.24%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹18.1 L+₹1.3 L (7.80%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹18.3 L+₹1.5 L (8.70%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹19.3 L+₹2.5 L (14.9%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SURATGARH
GE (AF) SURATGARH
REPAIR TO ROOFING AND ALLIED WORKS IN ZONE A IN TECHNICAL AREA AT AF STATION SURATGARH
2021_MES_447989_1
8882/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹40,000
Yes
28 Oct 2021
3 Jun 2021
3 Jul 2021
3 Jun 2021
1 Jul 2021
17 Jun 2021
60 days
Amount
BOQ (REPAIR TO ROOFING AND ALLIED WORKS IN ZONE ‘A’ IN TECH AREA AT AF STATION SURATGARH )
Dismantling brick tiles or terracing tiles, single layer on roof , complete all as specified and directed by Engineer-in-Charge.
Demolition of mud, in roof, any thickness including plastering and leeping (whether full thickness removed or only a part thereof), complete all as specified and directed by the Engineer in Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete, 1:2:4 type B-0 nominal Mix (using 12.5 mm graded stone aggregate) as in padding / base of roof, complete all as specified and directed.
Water proofing treatment consisting evenly applied bituminious primer coat @ 0.40 litre/ Square metre on surfaces, overlaps, joints etc and a layer of APP polymer 3mm thick even membrane weight not less than 3 Kg/Sqm duly sealed at over laps joints with flame (complete by torch application) all as per manufacturer's instructions, over and including 10 mm thick rendering in cement mortar (1:4) mixed with and including liquid water proofing compound @ 2% by weight of cement, complete all as specified and directed by Engineer-in-Charge. (MAKE:- M/S STP LTD / M/S IWL / PEDILITE) Note:- (i) Contractor will be permitted to use materials procured from any one of the manufacturer mentioned as specified in PS clause. However the materials for the entire work shall be of from one manufacturer only. (ii) APP membrane shall be laid by torching with 100mm overlap in longitudinal direction and 150mm overlap in transverse direction. (iii) APP membrane shall be taken to a height of 30 cm and then insert inside the groove of parapet wall and shall be finished by a membrane flashing. (iv) Rate of taking down OHT (including fixtures) before operation and refixing the same complete all as directed by Engr-in-charge.
40 mm thick brick tiles laid onmud mortar and jointed and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska , complete all as specified and directed by the Engineer in Charge.
All as per serial item No 6 here-in-before but except brick tiles, complete all as specified and directed by the Engineer in Charge. Note: Servicable Tiles retrived from serial item no 1 above shall be used after proper cleaning and washing of old tiles.
Taking down cement plaster on brick walls or stone wall including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish in low lying area ,complete all as specified and directed by the Engineer in Charge.
Rendering 5 mm thick on RCC ceiling / facia / RCC chajja surfaces in cement mortar 1:3 and finished the surface even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
Rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces and applying two coats of exterior acrylic emulsion paint in camoflaging patterns (wheather proof), complete all as specified and directed by the Engineer-in-Charge.
Preparation of old surfaces of walls including scraping by mechinised means (Vacuum based sanding machine); scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and washing with water and applying two coats of exterior acrylic emulsion paint, (in camouflage pattern using number of colours), complete all as specified and directed by the Engineer-in-Charge.
Preparation of newly plastered or un-plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for treated surfaces to receive one coat of oil bound distemper (white or coloured) on walls by roller with smooth finishes, complete all as specified and directed by Engineer –in-Charge.
M&L for treated surfaces to receive one coat of oil bound distemper (white or coloured) on ceiling by roller with smooth finishes, complete all as specified and directed by Engineer –in-Charge.
Preparation of old surfaces of walls/ceiling including scraping by mechanized means (Vaccum based sanding machine), scrapping down smoke soot, moulds, moss and efflorencent salt, trading oil and greasy spots including removal of nails etc, complete all as specified and directed by Engineer –in-Charge.
M&L for painting treated surfaces to receive two coats of oil bound distemper (white or coloured) by roller including removal of nails over and including 1.5mm thick Birla / JK wall care putty to obtain smooth regular/ even finish by using sand paper, complete all as specified and directed by Engineer –in-Charge.
Complete removal of existing treatment on walls surfaces including scraping by mechinised means (Vacuum based sanding machine); scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and washing with water , complete all as specified and directed by Engineer –in-Charge.
M&L for 1.5mm thick Birla / JK wall care putty to obtain smooth regular/ even finish by using sand paper, complete all as specified and directed by Engineer –in-Charge.
Dismantling floor, hearth or wall tilling including cement morter bedding (but not backing), and removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed by Engineer-in-Charge
First quality glazed ceramic coloured tiles of size (450x300mm) x 7 to 8 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed by the Engineer in Charge.
M&L for 10mm thick rendering cement plaster in CM (1:4) on fair faces of brickwork or concrete surface as in backing to receive the tiles, complete all as specified and directed by the Engineer in Charge.
First quality glazed ceramic coloured tiles of (300x200mm) x 7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed by the Engineer in Charge.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry and pointed in white cement with pigment to match the shade of tiles, complete all as specified and directed by the Engineer in charge.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry and pointed in white cement with pigment to match the shade of tiles, complete all as specified and directed by the Engineer in charge.
Vitrified ceramic tiles of premium quality, light shade, 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 Sq.m, laid in floors with neat cement slurry and pointed in white cement with pigment to match the shade of tiles,complete all as specified and directed by the Engineer in Charge.
M&L for 15 mm thick screed bed of cement mortar (1:6) for laying floor finishes, complete all as specified and directed by the Engineer in charge.
20 mm thick machine cut granite stone slab as in flooring with neat cement slurry @ 3.00 kg/Square Metre over and including 20 mm thick (average thickness) cement screed (1:4) base, laid and jointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish), complete all as specified and directed by the Engineer in Charge.
20 mm thick machine cut granite stone slab as in skirting/dado including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed of 10 mm thick in CM 1:4, complete all as specified and directed by the Engineer in Charge.
Granite (any type) 20 mm thick, work (table rubbed and polished) in steps, windows cills, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed of 15 mm thick in CM 1:4, complete all as specified and directed by the Engineer in Charge.
Demolition of stone slab & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar ,complete all as specified and as directed by Engineer-in-Charge.
Rubbing, grinding and polishing to existing Granite / Kota stone as in flooring, skirting by hand grinding machine including jointed/pointed with grey cement slurry mixed with pigment to match shade of the slab (if required), after grinding and finally washing the surface clean with oxalic acid solution and polishing with bees wax polish to achieve granite finish, complete all as specified and directed by the Engineer in Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description not exceeding 1.50 Sqm each, and making good the disturbed Surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description exceeding 1.50 Sqm but not exceeding 4.00 Sq. m each, and making good the disturbed Surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
150 mm size (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed by the Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings including taking down old unservicable chowkhat with door/window and the directions of Engineer-in-Charge.
Anodised aluminium work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings including taking down old unservicable chowkhat with door/window and the directions of Engineer-in-Charge.
12 mm thick Pre-laminated particle board, exterior grade, pre-laminated both side with decorative choice lamination and fixed with screws to frame work as in cup board shutter, partitions, shelves, complete all as specified and directed.
4.8 mm thick plain sheet glass, ordinary quality and glazing with oil putty or fixed with beads in square not exc. 0.5 Sqm in each pane complete all as specified and directed.
Aluminium (die cast body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutter of 851 to 1000mm width and of weight between 61 to 80 kgs and fixed as in repair, complete all as specified and directed by Engineer-in-Charge
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted as per specification & drawing and as per manufacturer's instructions and shown on drawing on Page 160 of SSR Pt-II ,complete all as specified and directed by the Engineer in Charge.
Factory made solid panel PVC Door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail,lock rail and bottom rail on either side as gap insert for top rails, bottom rail,panelling of plain colour PVC sheet to be fitting in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supply & fixing in the frame at site as per specification and drawing on Page No 156 of SSR Part-II Rates,complete all as specified and directed by the Engineer in Charge.
Aluminium handles cast type anodised of 125mm size , complete all as specified and directed by Engineer-in-Charge.
Aluminum anodizes barrel tower bolts of extuded section and fixed of 150 mm long size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Butt hinges aluminium polished of 100 mm size and fixed ,complete all as specified and directed by the Engineer in Charge.
32 mm size (Dia of discharge pipe) waste coupling of PTMT half or full threaded (minimum weight 45 gram), fixed as in repair, complete all as specified and directed.
Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for WHB/urinal/sinks, fixed as in repair, complete all as specified and directed by the Engineer in Charge.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed as in repair, complete all as specified and directed by the Engineer in Charge.
Pillar taps, 15 mm bore cast copper alloy chromium plated fancy type, with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe fixed as in repair, complete all as specified and directed by the Engineer in Charge.
Stop valve 15 mm dia cast copper alloy , fancy type chromium plated with long shank and cup (concealed type), screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and directed by Engineer-in-Charge.
Grating round 100mm size of PTMT (minium weight 50 gram) fixed in repair , complete all as specified and directed by the Engineer in -Charge.
Wash basins, vitreous china, white, flat back of size 630X450 mm with pedestal including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste coupling fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new brackets fixed as in repair , complete all as specified and directed by the Engineer in Charge. Make :- CERA/HINDWARE/PARYWARE.
Counter wash basins, vitreous china, white, oval shape of size 440x525x195 mm including 32mm dia waste coupling fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new brackets fixed as in repair , complete all as specified and directed by the Engineer in Charge. Make :- CERA/HINDWARE/PARYWARE.
Stop valve 15 mm dia cast copper alloy, angle type decorative fancy type chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and directed by Engineer-in-Charge.
PVC connection of PTMT ,non corrosive with nuts and washers on both ends, 600mm long suitable for 15 mm bore fixed in repair , complete all as specified and directed by the Engineer in -Charge
PVC waste pipe 32mm dia socketed and 600mm long for WHB /sink / urinal, fixed in repair, complete all as specified and directed.
Vitreous China Half stall type urinals, white, with geating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (excluding of fixing supply pipe, flushing cistern, flush pipe, trap and waste pipe) complete all as specified and directed.
Vitreous china urinal partitions slabs white of size 310 x 700mm, fixed about 40cm above floor line, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rest (exclusive flusing cistern& flush pipe) including cast iron 'P' or 'S' trap of 100 mm bore pipe fixed in PCC 1:2:4 type B-2 and necessary lime concrete, fixed as in repairs, including making good the surface to match with existing floor finish fixed as in repair ,complete all as specified and directed by the Engineer in Charge. Make :- CERA/HINDWARE/PARYWARE.
Vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe) including plastic seat cover white and mild steel chromium plated aluminum hinging devices, connected to drains outlet, fixed as in repairs,complete all as specified and directed by the Engineer in Charge.
Dismantling of 75 to 100 mm bore Cast Iron or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
100 mm bore Cast Iron soil, waste and vent pipe, Spun pipe, in any length, with or without ears, with cement joints in cement sand mortar 1:1 with spun yarn fixed to walls / laid in trenches / in floors complete all as specified and directed.
75 mm bore Cast Iron soil, waste and vent pipe, Spun pipe, in any length, with or without ears, with cement joints in cement sand mortar 1:1 with spun yarn fixed to walls / laid in trenches / in floors complete all as specified and directed.
75 mm bore Cast Iron bend (any radius), diminishing piece or taper (larger bore measured), fixed as in repair, complete all as specified and directed.
100 mm bore Cast Iron bend (any radius), diminishing piece or taper (larger bore measured), fixed as in repair, complete all as specified and directed.
100 mm bore Cast Iron Tee/ branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches , fixed as in repair, complete all as specified and directed.
75 mm bore Cast Iron Tee/ branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches , fixed as in repair, complete all as specified and directed.
75 mm dia Cast Iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) , fixed as in repair, complete all as specified and directed.
75 mm dia Cast Iron Nahani trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) , fixed as in repair, complete all as specified and directed.
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets, fixed in repair complete all as specified and directed by Engineer-in-Charge.
125 / 110 mm size PVC (SWR) gully trap, setting and jointing with solvent cement, fixed in repair, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling our glazing pins / spring clips providing and fixing new one , complete all as specified and directed by Engineer-in-Charge.
Sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by the Engineer in charge.
Frosted / figured glass 3 mm thick, pin head type and glazing with oil putty or fixed with beads in square not exc. 0.5 Sqm in each pane complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal and average width of apreture 1.40mm and fixed with tinned teaks or wire staple, fixed as in repair complete all as specified and directed by Enginer-in-Charge.
Stainless steel wire cloth 0.36mm nominal and average width of apreture 1.40mm and fixed with tinned teaks or wire staple, complete all as specified and directed by Enginer-in-Charge.
Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches , pillars etc & removing debries out of MoD land, complete all as specified and directed by the Engineer-in-Charge.
Brick work with sub class 'B' , straight or curved on plan not exc 6m mean raidus built in cement mortar 1:6 , complete all as specified and directed by Engineer-in-Charge.
Brickwork with sub class 'B' bricks , straight or curved on plan not exc 6m mean raidus (except brick) built in cement mortar 1:6 , complete all as specified and directed by Engineer-in-Charge. Note: Servicable bricks retrived from serial item no 74 above shall be used after proper cleaning and washing of old bricks.
Preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper (white or coloured) by auto roller over and including 1.5mm thick Birla / JK wall care putty to obtain smooth regular/ even finish by using sand paper, complete all as specified and directed by Engineer –in-Charge.
Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., including cutting/chasing in wall/floor and removal from site, complete all as specified and directed by the Engineer in Charge.
Taking up or down 20 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., including cutting/chasing in wall/floor and removal from site, complete all as specified and directed by the Engineer in Charge.
Steel water tubes, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by the Engineer in Charge.
Steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by the Engineer in Charge.
Re-fixing steel water tubing of 15 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified.
Re-fixing steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified.
Cutting chases, pinning in, making good to facing where required exc 10 cm but not exc 20 cm girth and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, complete all as specified and directed by the Engineer in Charge.
Demolition of cement concrete of any description and in any position , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete 1:2:4 type B-0 (12.5 mm graded stone aggregate) 25mm thick as flooring finished fair & even to receive top layer of flooring , complete all as specified and directed by Engineer-in-Charge.
75 mm thick, plain cement concrete 1:3:6, type C-1, using 20 mm graded mechanically crushed stone aggregates, laid in 1:30 slope as in plinth protection , surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer in Charge. Note: (i) Plinth protection shall be laid to slope (1 in 30) in alternate bays not exceeding 3 mtr in length with joint of 6mm wide and 10mm deep shall be provide along the wall and bays and shall be filled with sealing compound grade 'B'. (ii) Cost of sealing compound is included in the unit rate of the item.
Demolition of cement concrete (reinforced) of any description and in any position , complete all as specified and directed by the Engineer in Charge.
Reinforced cement concrete 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like complete all as specified and directed by the Engineer in Charge. Note :- Reinforcement shall be measured and paid separately under respective item.
Reinforced cement concrete 1:2:4, type B-0, using 12.5 mm graded mechanically crushed stone aggregates, as in Chajjas and like complete all as specified and directed. Note :- Reinforcement shall be measured and paid separately under respective item.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed.
Use and waste of formwork to cornices and mouldings of any shape in cross section and of any girth in fair finished surface of concrete complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 05 cm and not exc. 10 cm in rough finished surface of concrete complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in rough finished surface of concrete complete all as specified and directed.
Mild steel TMT bars 10mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S, complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 6 to 8mm dia cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S, complete all as specified and directed by Engineer-in-Charge.
Dismantling existing water storage tanks exc 250 litres but n.exc 500 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and directed by Engineer-in-Charge
Rotational moulded PVC, tripple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve , complete all as specified and directed by Engineer –in-Charge.
Nipple 20mm bore suitable for HDPE water tank. (Minimum weight 20mm- 45gms) fixed as in repair complete all as specified and directed by Engineer –in-Charge.
Ball brass valve of 20mm bore, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass fixed as in repair complete all as specified and directed by Engineer –in-Charge.
Ball valve of 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) & fixed in repairs , complete all as specified and directed by Engineer-in-Charge.
Dismantling of structural steel work including doors, gates but excluding framed trusses complete all as specified and directed.
Dismantling asbestos cement (corrugated or semi corrugated, etc.) sheets as in roof covering ,complete all as specified and directed by Engineer-in-Charge.
Steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed.
Rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails, fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections), including distance pieces, cleats etc. including cutting, welding conforming to Fe 410-W (Gde- E- 250) quality- A complete all as specified and directed.
S & F of 6 mm thick asbestos cement corrugated or semi-corrugated sheets fixed with ‘L’ type or ‘J’ type or cranked hook bolts and washers as in roof covering, walls etc. complete all as specified and directed.
Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws , complete all as specified and directed by Engineer-in-Charge. Notes:- Colour of sheets shall be approved by GE.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and directed by Engineer-in-Charge.
Mild steel work in hand rails, half round or other stock section or core for wooden hand - rail straight portioon, drilled and countersunk for balusters, nosing of steps, including embeding in concrete and screwing etc. wind ties for roof including all necessary drilling, bolting or riveting, etc., and similar work complete all as specified and directed by Engineer-in-Charge.
Rubber beading 75mm wide 4mm thick fixed to wooden door with nails fixed as in repair complete all as directed.
Bib tap 15 mm size standard of PTMT, any colour high pressure screwed for iron pipes (minimum weight 90 gram) fixed as in repairs, complete all as specified and directed.
Chequered cement concrete designer tiles of size 30cm x 30cm x 25mm thick set jointed and pointed in neat cement slurry in floors with in grey cement and pigment over including 15mm thick screed bed in CM 1:6 , complete all as specified and directed by Engineer-in-Charge.
Factory made machine pressed precast concrete interlocking paver block any shape or size conforming to IS 15658 of 60 mm thickness M-35 grade with grey cement and no pigment laid over and including 25mm thick sand cushioning and filling the joints upto full depth with fine tibba sand, complete all as specified and directed by the Engineer in Charge.
Plain cement concrete, 1:4:8 type D-2 using (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed in repair , complete all as specified and directed by the Engineer in -Charge
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 16(R) of tender documents.
M/S Shree Ram Enterprises
PACHR BUILDERS
AK CONSTRUCTION
M/S VISHNU ENTERPRISES
shubham enterprises
H S BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .