Public Works Department
Shri Girish B Desai Executive Engineer PWD Div chi
9448860126
9448860126
Construction of Naukarar Bhavan of Karnataka Rajya Sarakari Naukarar Sangh Zilla Chikodi at Chikodi Taluka of Belagavi Dist Under the H/A 4059 Dept Buildings FY 2026-27.
PWD/2026-27/BD/WORK_INDENT37152
PWD/2026-27/BD/WORK_INDENT37152
Open
Buildings
Two Tender Document System(Two Cover)
PWD Division Office Chikkodi
10 documents required · 10 mandatory
To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e.,,2021-22,2022-23,2023-24 ,2024-25 and 2025-26 (c) executed in any one year, the following minimum quantities of work 1)BBM/AAC Blocks/SSM-145.92 CUM,2)Plastering-1489.48 SQM,3)Concrete(PCC/RCC)-184.22 CUM,4)Steel-32.56 TONNE&5)Flooring-751.83 SQM.
Satisfactorily completed (at least 90% of the contract value), as prime contractor, at least one similar work such as Building work of value not less than Rs. 60.34 Lakhs, in previous five years
Tenderers who meet the above specified minimum qualifying criteria will only be qualified,if their available tender capacity is more than the total tender value.The available tender capacity will be calculated as under Assessed available tender capacity is AXNX1.5-B where where A is Maximum value of civil engineering works executed in any one year during the last five years updated to 2026-27 price level taking into account the completed as well as works in progress.N is Number of years prescribed for completion of the works for which tenders are invited is 0.75 Year B is Value at 2026-27 price level, of existing commitments and on-going works to be completed during the next 0.75 year Period of completion of the works for which tenders are invited.
Maximum of Civil Engineering works executed in any one year during the last five years (updated to 2026-27 price level) taking into account the completed as well as works in progress. (Financial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2026-27)
Value at 2026-27 price level, of existing commitments and on-going works to be executed during the next 12 months(Financial commitment of previous years shall be given a weight of 10% per year to bring them to the price level of the 2026-27), (Monthwise commitment shall be furnished)
Each tenderer should demonstrate availability of few key equipments/machinery for execution of the work.However as per Govt circular No.GO FD/AE 263/EXP12-2022 dt 11-05-2022,this clause for owning key equipments for works costing upto Rs.3.00 crores is exempted. However it is obligatory for the contractor to use the following machineries for various activities involved in construction as per MORTH specification 1)Excavator like JCB/Hitachi etc.,2)Tippers,3)Concrete Batching Plant,4)Construction elevator/Building Hoist/Tower Cranes,5) Water Tanker,6) Shuttering Materials and 7) Transit Mixers
To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. 2021-22,2022-23,2023-24,2024-25and 2025-26(a) acheived in at least two financial years a minimum financial turnover of Rs.241.35 lakhs (in all classes of civil engineering construction works only)( Calculated as per Govt circular PWD.60.CRM.2021 Dated.08/11/2021)
Liquid Assets and or availability of credit facilities of no less than Rs.40.23Lakhs (Credit Lines or letter of credit or certificates from the banks for meeting the fund requirement etc
Report on the financial standing of the Tenderer, such as profit and loss statements and auditors report for the last five years.
The EMD of Rs.2,00,000.00 shall be paid in full through e payment or in two parts i.e. part (1) Rs.1,00,000.00 br e payment Part (2) Rs.1,00,000.00 EMD shall be in the form Bank Guarantee in the prescribed format obtained from any Nationalised / Scheduled Bank in favour of Executive Engineer, PWD Division, Chikodi payable at Chikodi
Constitutional or Legal Status of the Tenderer
Information on litigation in which the Tenderer is involved:
Name, Address, telephone No., Fax No., and email ID of the Tenderers Bankers
Principal Place of Business
Information on works which are yet to be completed
Information of the works for which Tender acceptance letters are received.
Information of the works for which Tenderer has submitted Tender
Assessed Tender Capacity shall be more than the Tendered Amount
₹3,020
₹2 L
25 Aug 2026
25 Aug 2026
15 Sept 2026
9 Sept 2026
8 Sept 2026
Information on litigation in which the Tenderer is involved:
Other Party/Parties Employer Details of Dispute Amount involved Remarks showing Present Status
BANKER’S CERTIFICATE
This is to certify that M/s. ………………………….. is a reputed company with a good financial standing. If the contract for this work, namely ……………………………… (Name of the work) is awarded to the above firm, we shall be able to provide overdraft/credit facilities to the extent of Rs. …………… to meet the working capital requirements for executing the above contract
Name of the Bank, Senior Bank Manger
Address:…………………………
List of Machinery
Note: Minimum 50% of the required machinery should be owned by the Tenderer. Remaining 50% of the required machinery may be owned / procurred on Lease basis / Hire basis.
Item of Equipment Requirement Owned/ Hired/Leased Owned/ Hired/Lease and available Remarks
No. Capacity Number/Capacity Age/ Condition
FORMAT FOR WORK DONE CERTIFICATE TO BE OBTAINED FROM COMPETENT AUTHORITY
has executed/ is executing(strike off which ever is not applicable) the work of .............................................
in this Organisation. The details of the work is as under:
1 Name of the Project :
2 Name of the Work :
3 Contract Amount :
4 Date of signing the Agreement :
5 Date of handing over of the Site :
6 Items executed :
Earth work excavation :
UCR/SSM/B.B.M :
P.C.C / R.C.C :
Alluminium & Steel work (Doors, Windows & Partition) :
Address for correspondence:
Information of the works for which Tenderer has submitted Tender.
Project Name Name & Address of the Employer Name of Work Amount put to Tender in Rs lac. Specified period of completion (including/excluding Monsoon Prescribed last date of submission of tender Probable date of decision on the Tender Remarks if any.
Information of the works for which Tender acceptance letters are received.
Project Name Name & Address of the Employer Name of Work Tendered Amount in Rs lac Specified period of completion (including/excluding Monsoon Probable Date of Handing over of site
Information on works which are yet to be completed.
Project Name Name & Address of the Employer Name of Work Contract Number Value of contract Rs. Lakhs Date of Markout /Date of Handing over of site Specified period of completion (including/ excluding Monsoon cost of balance works remaining Rs. in lac Probable date of completion
Year Name of work Name of Employer Quantity of work performed Remarks (Indicate contract reference)
2012-13 Exc & Embankment
Water Prrofing/Wall Panneling
2013-14 Exc & Embankment
Water Prrofing/Wall Panneling
2014-15 Exc & Embankment
Water Prrofing/Wall Panneling
2015-16 Exc & Embankment
Water Prrofing/Wall Panneling
2016-17 Exc & Embankment
Water Prrofing/Wall Panneling
Work executed as prime contractor (in the same name) on works of similar nature during the five years specified)
Project Name Name & Address of the Employer Name of Work Contract Number Value of contract Rs. Lakhs Date of Markout /Date of Handing over of site Specified period of completion (including/excluding Monsoon Actual date of completion Remarks (appreciation letter received for early completion or reasons, if there is delay in completion)
Financial Year Total value of works executed and payments received in the last five years (in Rs. lac)
Building work of Naukarar Bhavan of Karnataka Rajya Sarakari Naukarar Sangh Zilla Chikodi at Chikodi Taluka of Belagavi Dist
Sl no Items Unit Milestone -1 Quantity Milestone -2 Quantity Milestone -3 Quantity Total Quantity Rate in Rs. Amount for Mile Stone 1 in Rs Amount for Mile Stone 2 in Rs Amount for Mile Stone 3 in Rs Total Amount in Rs Qty Rate
Building work (Civil) Sl No Description Unit Qty
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 0 0 70824.6
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 0 0 70825.6
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 0 0 70826.6
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. m³ 0 0 70827.6
supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. m² 0
Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. each 0
Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. m³ 0.19 0 0 102797.24
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 40 mm thick one side teak and one side commercial m² 0 0
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. No. 0 0 70829.6
Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. - 35 mm thickness m² 0 0
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of Glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float Glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) m² 0 0
Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head Glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) m² 0 0
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. kg 0 0
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. m² 0 0
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. m² 0 0
Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm m² 0 0
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. m² 0 0
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. m² 0 0 70830.6
Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m² 0 0 70831.6
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m² 0 0 70832.6
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m² 0 0
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. m² 0 0
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. kg 0 0
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. kg 0 0
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 25 mm nominal dia Pipes m 0 0
Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - 110mm nominal dia pipes m 0 0
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid each 0 0
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern each 0 0
Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. m² 0 0
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps each 0 0
Providing and fixing PTMT bib cock of approved quality and colour - 15 mm nominal bore, 90 mm long, weighing not less than 93 g No. 0 0
Providing and fixing PTMT stop cock of approved quality and colour - 15 mm nominal bore, 86 mm long, weighing not less than 88 g No. 0 0
Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete 1 Nahani trap 0 0
Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. - 125mm No. 0 0
Providing and fixing aluminium die cast body tubular type universal hy- draulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. No. 0 0
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. No. 0 0 70833.6
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. No. 0 0 70834.6
Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. No. 0 0 70835.6
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete No. 0 0
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125mm each 0 0
Building work (Electrical ) Sl No Description Unit Qty
Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary19/20 mm dia 2 mm thick m 0 0
Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 25 mm dia 2 mm thick m 0 0
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fishwire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick m 0 0
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fishwire run throughout the conduit wherever necessary.25 mm dia 2 mm thick m 0 0
Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200x90x65mm Each 0 0 70836.6
Supplying and fixing PVC/metal conduit accessories Deep junction box. 19/20mm deep junction box Each 0 0 70837.6
Supplying and fixing PVC/metal conduit accessories Deep junction box. 25mm deep junction box Each 0 0 Sl No Description Unit Qty
Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete. up to 50mm conduit in brick wall m 0 0
Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete. up to 50mm conduit CC floor m 0 0
Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mm m 0 0
Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm m 0 0
Supplying And Fixing Metal Fan Box with Round Hook. No 0 0
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Point 0 0
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let viaswitch box Point 0 0
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let viaswitch box Point 0 0
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 m 0 0
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 m 0 0
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 m 0 0
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 m 0 0
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 10 mm2 m 0 0
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 16 mm2 m 0 0
Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required IS 1293 Each 0 0
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6 Amps lamp holder No 0 0
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall1-2 Way Each 0 0
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way Each 0 0
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way Each 0 0
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way Each 0 0
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way Each 0 0
Descrp Unit Qty Rate
1 Item Code : KPWD-2023-24, Page No-20, Item No- 5.42.2 0.44 42500 No --- 18700 1 Fabricating supplying and mounting MS box made out SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete, 16SWG Sq CM 0.44 42500
2 Item Code : KPWD Elec SR - 2023-24 - Page No.18, Item No. -5 5711.35 7 No --- 39979.45 2 Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood panel board., 63 A 4 pole (KPWD Elec SR - 2023-24 - Page No.18, Item No. -5.20.10) Each 5711.35 7
3 Item Code : KPWD-2023-24, Page No-21, Item No- 5.47 2384.45 3 No --- 7153.35 3 Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts,nuts and washers etc.,.) 3-120sec setting. Each 2384.45 3
4 Item Code : KPWD-2023-24, Page No-20, Item No- 5.40.1 2538.95 2 No --- 5077.9 4 Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. (49/6.39) - 100Amps 4x30x6mm Aluminum Strips Mtr 2538.95 2
5 Item Code : KPWD Elec SR - 2023-24 - Page No.17, Item No. -5. 6268.58 3 No --- 18805.74 5 Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA.(KPWD Elec SR - 2023-24 - Page No.17, Item No. -5.15.1 ) Each 6268.58 3
6 Item Code : KPWD Elec SR - 2023-24 - Page No.19, Item No. - 5 530.45 5 No --- 2652.25 6 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (KPWD Elec SR - 2023-24 - Page No.19, Item No. - 5.38 ) Each 530.45 5
7 Item Code : KPWD Elec SR - 2023-24 - Page No.19, Item No. - 5 4521.7 1 No --- 4521.7 7 Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. (KPWD Elec SR - 2023-24 - Page No.19, Item No. - 5.31 ) Each 4521.7 1
8 Item Code : KPWD Elec SR - 2023-24 - Page No.14, Item No. -5. 711.73 4 No --- 2846.92 8 Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers., 100 A (KPWD Elec SR - 2023-24 - Page No.14, Item No. -5.7.4) Each 711.73 4
9 Item Code : PWD SR Electrical -2023-24 Part-III pg.no-6, Ite 96.82 1200 No --- 116184 9 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010. 4C x 1.5 mm2 (PWD SR Electrical -2023-24 Part-III pg.no-6, Item -2.5.3) Mtr 96.82 1200
10 Item Code : KPWD Elec SR - 2023-24 - Page No.11, Item No. -4. 20085 4 No --- 80340 10 Fabricating, supplying and erection of . ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom . mm , top. mm with 3 mm thick, suitable base plate and 4Nos of . long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. 9 m - Top 70 mm and Bottom 155 mm dia (KPWD Elec SR - 2023-24 - Page No.11, Item No. -4.2.,vol-06) Each 20085 4
11 Item Code : KPWD Elec SR - 2023-24 - Page No.46, Item No. -11 10361.8 8 No --- 82894.4 11 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage Overload, short circuit miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABLCPRI & any Government certified agency & Design & Development facility certified by ISO 9001 2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect.LED Streetlight 120 Each 10361.8 8
12 Item Code : KPWD Elec SR - 2023-24 - Page No.21, Item No. - 5 826.06 4 No --- 3304.24 12 Supplying and fixing of Modular MCB Devices (Tripper)With Breaking capacity of 6kA., 16 - 32 A TP Each 826.06 4
13 Item Code : KPWD Elec SR - 2023-24 -Page No.13, Item No. -4.6 2678 4 No --- 10712 13 Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000 mm Standard 40/50 mm dia, (KPWD Elec SR - 2023-24 -Page No.13, Item No. -4.6.3,vol-06) Each 2678 4
14 Item Code : KPWD Elec SR - 2023-24 - Page No.12, Item No. - 4 10609 12 No --- 127308 14 Fabricating, supplying and erection of . ms long hot dip Galvanized Conical hot dip Pole with BSEN10025 grade S355JO steel plate for shaft, IS2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per specifications suitable to withstand the wind speed of 47m/s for . m Pole in single section and single joint welded as per IS 9595/IS10178AW Shaving dimensions bottom.mm, top .mm with 3mm thick, suitable base plate and 4Nos of.long J bolts along with template and the Pole shall be hotdip galvanized in single dipping with not less than 65micron as perASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended., 5 m - Top 75 mm and Bottom 125 mm dia, (KPWD Elec SR - 2023-24 - Page No.12, Item No. - 4.4.3,vol-06 Each 10609 12
15 Item Code : KPWD Elec SR - 2023-24 -Page No.45, Item No. -11. 9910.66 12 No --- 118927.92 15 Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising ofantiglare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs50000hr@Lumen Maintenance of 70, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08.PowerFactor0.9 with mains, SurgeProtection-Min5KV along with Over voltage/Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS10322/1EC60598, LM79&LM80 Adherence with RoHS UL approved MCPCBLED Efficiency 1301 m/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited byNABL/CPRI &any Government certified agency&Design&Development facility certifiedby ISO9001:2008.Housingwith supplier word mark /name shall beEngraved Embossing on the diecast housing/Body part Warranty of 2Years against an manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Post Top Lantern with 35/40 W Each 9910.66 12
16 Item Code : BESCOM-2023-24, Page No-13, Item No-4.5.1 134930 2 No --- 269860 16 Fabrication, Supplying, Erection, Testing and Commissioning of Mtrs long polygon high mast with Single Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grade S 355 JO /ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/sec as per IS 875 part 3(as per GA Drawing).Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint. The mast shall have 2way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5sqmm EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement. The mast shall have manual power tool (Suitable reversible 15 Sl. No. Description Unit Rate Rs. Ps. geared motor operating on 230 415V, 50Hz, shall be provide above 15 Mtrs mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin lamps fitting with wiring complete. (excluding foundation) as per technical data. 12Mtrs/12.5Mtrs - Top 100mm and bottom 310 mm dia (KPWD Elec SR - 2023-24 - Page No-13, Item No-4.5.1, vol-06) Each 134930 2
17 Item Code : BESCOM-2023-24, Page No-46, Item No-11.9.3 11079.71 8 No --- 88637.68 17 Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001 2008 . Housing with supplier word mark /name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. LED Floodlight 120W Each 11079.71 8
18 Item Code : ESCOMs-2023-24, Page No-30, Item No-66.05,vol-06 64206.08 1 No --- 64206.08 18 Optical Fibre Cable (OFC) and its Accessories, HDPE/PLB Pipe 40/33 mm, ESCOMs-2023-24, Page No-30, Item No-66.05,vol-06 Km 64206.08 1
19 Item Code : PWD-2023-24, Page No-2, Item No-1.2.2,vol-6, 80.34 50 No --- 4017 19 Optical Fibre Cable (OFC) and its Accessories, HDPE/PLB Pipe 40/33 mm, ESCOMs-2023-24, Page No-30, Item No-66.05,vol-06 m 80.34 50
20 Item Code : PWD-2023-24, Page No-5, Item No-2.3.3,vol-6, 43.26 100 No --- 4326 20 Supplying heavy gauge PVC conduit pipe.mm dia.mm thick confirming toIS2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc.,and running before concreting the slab. The conduit shouldbe tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary,PWD-2023-24, Page No-2, Item No-1.2.2,vol-6, m 43.26 100
21 Item Code : PWD-2023-24, Page No-8, Item No-3.2,vol-6, 175.1 12 No --- 2101.2 21 Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance singlecore in open or concealed system of wiring with specified IS 694:2010 2.5 mm, PWD-2023-24, Page No-5, Item No-2.3.3,vol-6, Each 175.1 12
22 Item Code : PWD-2023-24, Page No-44, Item No-11.4. 2,vol-6, 1307.07 12 No --- 15684.84 22 Supplying and mounting 2Nos. of 2 Way 6A flush type switches either surface /flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854, PWD-2023-24, Page No-8, Item No-3.2,vol-6, Each 1307.07 12
23 Item Code : KPWD Elec SR 2023-24-Page No.54,Item No.12.56 3615.3 8 No --- 28922.4 23 Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts andother equipment'son the meter board using 40mm di 2.90mm thick GI pipe 2.5m long buried in a pit .The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification 7.3.3.of IS732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia No 3615.3 8
24 Item Code : ESCOMs SR 2023-24 - Page No 13, Item No. -32.05 146097.26 1.2 No --- 175316.71 24 Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975, 4 core 16 sqmm Km 146097.26 1.2
25 Item Code : BESCOM-2023-24, Page No-5, Item No-7.02 47621.02 1.5 No --- 71431.53 25 Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM Km 47621.02 1.5
26 Item Code : BESCOM-2023-24, Page No-3, Item No-1.01 7288.28 15 No --- 109324.2 26 RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785,BESCOM-2023-24, Page No-3, Item No-1.01,vol-06 No 7288.28 15
27 Item Code : BESCOM-2023-24, Page No-5, Item No-6.01 85.49 36 No --- 3077.64 27 11 kV Ceramic Pin Insulator (Shell only) BESCOM-2023-24, Page No-5, Item No-6.01, vol-06 No 85.49 36
28 Item Code : BESCOM-2023-24, Page No-3, Item No-1.05 3809.97 6 No --- 22859.82 28 PSCC Pole - 8 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/49 Dtd 24.11.2018) as per REC Standards No 3809.97 6
29 Item Code : BESCOM-2023-24, Page No-3, Item No-2.01 383.16 75 No --- 28737 29 11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018) No 383.16 75
30 Item Code : BESCOM-2023-24, Page No-3, Item No-2.05 297.67 60 No --- 17860.2 30 LT 4 Pin Cross Arm - MS (Dwg No. BESCOM/GM/QS&S/32 Dtd 24.11.2018) No 297.67 60
31 Item Code : BESCOM-2023-24, Page No-4, Item No-5.01 87.55 15 No --- 1313.25 31 RCC Pole Clamp - MS (Dwg No. BESCOM/GM/QS&S/30 Dtd 24.11.2018) No 87.55 15
32 Item Code : BESCOM-2023-24, Page No-4, Item No-5.03 75.19 6 No --- 451.14 32 PSCC Pole (140 Kg WL) Clamp - MS (Dwg No. BESCOM/GM/QS&S/31 Dtd 24.11.2018 No 75.19 6
33 Item Code : BESCOM-2023-24, Page No-5, Item No-6.09 525.3 60 No --- 31518 33 DISC Insulator 45 kN Porcelain No 525.3 60
Descrp Unit Qty Rate
1 Category : Vol - 3 -Chapter -2- SITE CLEARANCE --- 719 754.95 325.13 245456.89 Dismantling of Structures - Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead - Lime /Cement Concrete - By Mechanical Means - Cement Concrete Grade M-15 & M-20 m³ 325.13 754.95 245456.8935
2 Category : Vol - 1 -Chapter -I- Earth Work --- 95 108.82 600 65292 Mechanical Means - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth m³ 600 108.82 65291.99999999999
3 Category : Vol - 1 -Chapter -I- Earth Work --- 102 116.84 184.13 21513.75 Mechanical Means - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m m³ 184.13 116.84 21513.7492
4 Category : Vol - 1 -Chapter -I- Earth Work --- 363 415.79 828.77 344594.28 Mechanical Means - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth m³ 828.77 415.79 344594.2783
5 Category : Vol - 1 -Chapter -II- Concrete Works 0 5918 6778.74 82.88 561821.97 Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates m³ 82.88 6778.74 561821.9711999999
6 Category : Vol - 1 -Chapter -II- Concrete Works 0 6227 7394.22 126.33 934111.81 Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 126.33 7394.22 934111.8126000001
7 Category : Vol - 1 -Chapter -II- Concrete Works 0 6227 7786.52 160 1245843.2 Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 160 7786.52 1245843.2000000002
8 Category : Vol - 1 -Chapter -II- Concrete Works 0 6227 7786.52 141.27 1100001.68 Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 141.27 7786.52 1100001.6804000002
9 Category : Vol - 1 -Chapter -II- Concrete Works 0 6227 7786.52 149.1 1160970.13 Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 149.1 7786.52 1160970.132
10 Category : Vol - 1 -Chapter -II- Concrete Works 0 6734 8420.5 39.12 329409.96 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 39.12 8420.5 329409.95999999996
11 Category : Vol - 1 -Chapter -II- Concrete Works 0 6734 8420.5 69.37 584130.08 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 69.37 8420.5 584130.0850000001
12 Category : Vol - 1 -Chapter -II- Concrete Works 0 6734 9127.57 204.54 1866953.17 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 204.54 9127.57 1866953.1678
13 Category : Vol - 1 -Chapter -II- Concrete Works 0 87305 91670.25 13.2 1210047.3 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Foundations of Bridges t 13.2 91670.25 1210047.3
14 Category : Vol - 1 -Chapter -II- Concrete Works 0 87532 91908.6 34.4 3161655.84 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Sub structure of Bridges t 34.4 91908.6 3161655.84
15 Category : Vol - 1 -Chapter -II- Concrete Works 0 87758 92145.9 19.6 1806059.64 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Super structure of Bridges t 19.6 92145.9 1806059.6400000001
16 Category : Vol - 3 -Chapter -12- SUB-STRUCTURE OF BRIDGES --- 2677 2810.85 348.07 978372.56 Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Ref to MoRT&H : IRC - 710.1.4. of IRC :78 & 2200 m³ 348.07 2810.85 978372.5595
17 Category : Vol - 3 -Chapter -12- SUB-STRUCTURE OF BRIDGES --- 1168 1226.4 702.13 861092.23 Back filling behind abutment, wing wall and return wall complete including compaction as per drawing and Technical Specification - Granular material. Ref to MoRT&H : IRC - 710.1.4. of IRC :78 & 2200 m³ 702.13 1226.4 861092.2320000001
18 Category : Vol - 1 -Chapter -I- Earth Work --- 266 279.3 176.72 49357.9 Manual Means - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. m³ 176.72 279.3 49357.896
19 Category : Vol - 3 -Chapter -13- SUPER-STRUCTURE OF BRIDGES --- 6727 7063.35 9.87 69715.26 PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification. Ref to MoRT&H : IRC - 2700 m³ 9.87 7063.35 69715.2645
20 Category : Vol - 3 -Chapter -13- SUPER-STRUCTURE OF BRIDGES --- 11201 11761.05 19.74 232163.13 Reinforced cement concrete M30 grade for approach slab including reinforcement and formwork complete as per drawing and Technical specification (Batching Plant). Ref to MoRT&H : IRC - 1500, 1600, 1700 & 2704 m³ 19.74 11761.05 232163.12699999998
21 Category : Vol - 3 -Chapter -13- SUPER-STRUCTURE OF BRIDGES --- 13087 13741.35 24.72 339686.17 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. (Batching Plant). Ref to MoRT&H : IRC - 2702 m³ 24.72 13741.35 339686.172
22 Category : Vol - 3 -Chapter -13- SUPER-STRUCTURE OF BRIDGES --- 2126 2232.3 72.44 161707.81 Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, c/c spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. Ref to MoRT&H : IRC - 2703, 1500, 1600 & 1700 m 72.44 2232.3 161707.812
23 Category : Vol - 3 -Chapter -13- SUPER-STRUCTURE OF BRIDGES --- 3271 3434.55 18 61821.9 Drainage Spouts using 100 mm GI pipe complete as per drawing and Technical specification. Ref to MoRT&H : IRC - 2705 No 18 3434.55 61821.9
24 Category : Vol - 3 -Chapter -13- SUPER-STRUCTURE OF BRIDGES --- 137 143.85 47.08 6772.46 Filler joint - Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Ref to MoRT&H : IRC - 2605 m 47.08 143.85 6772.458
25 Category : Vol - 3 -Chapter -12- SUB-STRUCTURE OF BRIDGES --- 138 144.9 42.8 6201.72 Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications. Ref to MoRT&H : IRC - 2706 & 2200 m 42.8 144.9 6201.72
26 Category : Vol - 3 -Chapter -2- SITE CLEARANCE --- 1096 1150.8 45 51786 Removing all type of Hume Pipes and Stacking including Earthwork and Dismantling of Masonry Works. - Above 600 mm to 900 mm dia m 45 1150.8 51786
27 Category : Vol - 3 -Chapter -17- ROAD & BRIDGE WORKS TESTING & MAINTENANCE --- 1250 1312.5 112 147000 Bridge Maintenance & Testing - Providing and fixing 25mm diameter steel anchor dowel in hard rock including drilling hole of 32 mm diameter up to 0.75 mtrs depth, placing the dowel in position and effectively grouting the hole with CM 1:1 proportion etc. complete. No. 112 1312.5 147000
Descrp Unit Qty Rate
1 Category : Vol - 1 -Chapter -I- Earth Work --- 474 497.7 598.38 297813.73 Manual Means - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. m³ 598.38 497.7 297813.72599999997
2 Category : Vol - 3 -Chapter -3- EARTH WORK, EROSION CONTROL AND DRAINAGE --- 493 517.65 571.2 295681.68 Construction of Subgrade and Earthen Shoulders - Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2. Ref to MoRT&H : IRC - 305 m³ 571.2 517.65 295681.68
3 Category : Vol - 3 -Chapter -4- SUB-BASES, BASES (NON-BITUMINOUS), SHOULDERS AND STABILIZATION METHODS --- 2359 2476.95 561 1389568.95 Granular Sub-Base - By Mix in Place Method - Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 - For Grading -V Material. Ref to MoRT&H : IRC - 401 m³ 561 2476.95 1389568.95
4 Category : Vol - 3 -Chapter -4- SUB-BASES, BASES (NON-BITUMINOUS), SHOULDERS AND STABILIZATION METHODS --- 2559 2686.95 637.5 1712930.62 Wet Mix Macadam (Plant Mix Method) - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory rollerto achieve the desireddensity. Ref to MoRT&H : IRC - 406 m³ 637.5 2686.95 1712930.625
5 Category : Vol - 3 -Chapter -5- BASES AND SURFACE COURSES (BITUMINOUS) --- 63 66.15 2550 168682.5 Prime Coat over WMM/WBM - Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. Ref to MoRT&H : IRC - 502 m² 2550 66.15 168682.5
6 Category : Vol - 3 -Chapter -5- BASES AND SURFACE COURSES (BITUMINOUS) --- 22 23.1 2550 58905 Tack coat on Granular surface treated with primer - Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m2 on Granular Surface. Ref to MoRT&H : IRC - 503 m² 2550 23.1 58905
7 Category : Vol - 3 -Chapter -5- BASES AND SURFACE COURSES (BITUMINOUS) --- 9897 10391.85 127.5 1324960.88 Bituminous Macadam Grading - II for traffic <20 MSA - Providing and laying Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.4% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. Ref to MoRT&H : IRC - 504 m³ 127.5 10391.85 1324960.875
8 Category : Vol - 3 -Chapter -5- BASES AND SURFACE COURSES (BITUMINOUS) --- 13601 14281.05 63.76 910559.75 Semi Dense Bituminous Concrete - Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. Ref to MoRT&H : IRC - IRC-37:2018 m³ 63.76 14281.05 910559.7479999999
9 Category : Vol - 3 -Chapter -8- TRAFFIC CALMING MEASURES, ROAD SIGNAGES & MARKING (ROAD FURNITURE) --- 530 556.5 68 37842 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface - Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 g/m2 area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35:2015.The finished surface to be level, uniform and free from streaks and holes. Ref to MoRT&H : IRC - 803 m² 68 556.5 37842
10 Category : Vol - 3 -Chapter -8- TRAFFIC CALMING MEASURES, ROAD SIGNAGES & MARKING (ROAD FURNITURE) --- 365 383.25 60 22995 Supplying and Fixing of Molded Shank Raised Pavement Markers / Cats Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 cm2 on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturers recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. Ref to MoRT&H : IRC - MoRTH 806 No. 60 383.25 22995
11 Category : Vol - 3 -Chapter -8- TRAFFIC CALMING MEASURES, ROAD SIGNAGES & MARKING (ROAD FURNITURE) --- 4735 4971.75 2 9943.5 Retro-Reflectorised Traffic Signs - Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class C Type XI retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022. - 90 cm equilateral triangle each 2 4971.75 9943.5
12 Category : Vol - 3 -Chapter -8- TRAFFIC CALMING MEASURES, ROAD SIGNAGES & MARKING (ROAD FURNITURE) --- 733 769.65 80 61572 Boundary pillar / Guard Stone - Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting. Ref to MoRT&H : IRC - 807 each 80 769.65 61572
13 Category : Vol - 3 -Chapter -3- EARTH WORK, EROSION CONTROL AND DRAINAGE --- 6 6.3 700 4410 Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material by Mechanical Means using Hydraulic excavator with in all lifts and lead. Ref to MoRT&H : IRC - 305.4.3 m² 700 6.3 4410
Descrp Unit Qty Rate
Descrp Unit Qty Rate
1 Item Code : item no 1.2.1 p.no 2 66 900 No --- 59400 Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary19/20 mm dia 2 mm thick m 900 66
2 Item Code : item no 1.2.2 p.no 2 78 100 No --- 7800 Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 25 mm dia 2 mm thick m 100 78
3 Item Code : item no 1.3.1 p.no 2 68 347 No --- 23596 Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fishwire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick m 347 68
4 Item Code : item no 1.3.2 p.no 2 79 280 No --- 22120 Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fishwire run throughout the conduit wherever necessary.25 mm dia 2 mm thick m 280 79
5 Item Code : item no 1.4.5 p.no3 179 5 No --- 895 Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200x90x65mm Each 5 179
6 Item Code : item no 1.5.1 p.no3 49 112 No --- 5488 Supplying and fixing PVC/metal conduit accessories Deep junction box. 19/20mm deep junction box Each 112 49
7 Item Code : item no 1.5.2 p.no3 56 50 No --- 2800 Supplying and fixing PVC/metal conduit accessories Deep junction box. 25mm deep junction box Each 50 56
8 Item Code : item no 1.7.1 p.no3 29 10 No --- 290 Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete. up to 50mm conduit in brick wall m 10 29
9 Item Code : item no 1.7.2 p.no3 69 10 No --- 690 Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete. up to 50mm conduit CC floor m 10 69
10 Item Code : item no 1.9.1 p.no4 19 10 No --- 190 Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mm m 10 19
11 Item Code : item no 1.9.2 p.no4 22 10 No --- 220 Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm m 10 22
12 Item Code : item no 1.13 p.no 4 117 17 No --- 1989 Supplying And Fixing Metal Fan Box with Round Hook. No 17 117
13 Item Code : item no 2.2.1 p.no 5 269 49 No --- 13181 Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Point 49 269
14 Item Code : item no 2.2.2 p.no 5 379 44 No --- 16676 Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let viaswitch box Point 44 379
15 Item Code : item no 2.2.3 p.no 5 555 18 No --- 9990 Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let viaswitch box Point 18 555
16 Item Code : item no 2.3.2 p.no 5 26 1050 No --- 27300 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 m 1050 26
17 Item Code : item no 2.3.3 p.no 5 42 2100 No --- 88200 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 m 2100 42
18 Item Code : item no 2.3.4 p.no 5 63 30 No --- 1890 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 m 30 63
19 Item Code : item no 2.3.5 p.no 5 92 25 No --- 2300 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 m 25 92
20 Item Code : item no 2.3.6 p.no 5 167 15 No --- 2505 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 10 mm2 m 15 167
21 Item Code : item no 2.3.7 p.no 5 318 10 No --- 3180 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 16 mm2 m 10 318
22 Item Code : item no 3.2 p.no 6 170 4 No --- 680 Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required IS 1293 Each 4 170
23 Item Code : item no 3.14.6 p.no 6 71 60 No --- 4260 Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6 Amps lamp holder No 60 71
24 Item Code : item no 3.4.1 p.no 8 138 6 No --- 828 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall1-2 Way Each 6 138
25 Item Code : item no 3.4.3 p.no 8 177 17 No --- 3009 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way Each 17 177
26 Item Code : item no 3.4.4 p.no 8 220 2 No --- 440 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way Each 2 220
27 Item Code : item no 3.4.5 p.no 8 261 2 No --- 522 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way Each 2 261
28 Item Code : item no 3.4.6 p.no 8 319 15 No --- 4785 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way Each 15 319
Descrp Unit Qty Rate
1 Category : Vol - 1 -Chapter -II- Concrete Works 1 6734 11909.15 54.11 644404.11 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 54.11 11909.15
2 Category : Vol - 1 -Chapter -II- Concrete Works 1 6734 11208.6 55.31 619947.67 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 55.31 11208.6
3 Category : Vol - 1 -Chapter -II- Concrete Works 1 6734 10508.07 120.86 1270005.34 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 120.86 10508.07
4 Category : Vol - 2 -Chapter -6- Masonry Works 1 7978 8299.51 182.41 1513913.62 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. m³ 182.41 8299.51
5 Category : Vol - 1 -Chapter -II- Concrete Works 1 90464 94109.7 40.71 3831205.89 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings t 40.71 94109.7
6 Category : Vol - 2 -Chapter -11- Steel and Aluminium Work 1 2633 2739.11 204.33 559682.35 supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. m² 204.33 2739.11
7 Category : Vol - 2 -Chapter -11- Steel and Aluminium Work 1 3086 3210.37 19 60997.03 Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. each 19 3210.37
8 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 98815 102797.24 0.19 19531.48 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m³ 54.11 11909.15
9 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 4300 4473.29 3.78 16909.04 Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 40 mm thick one side teak and one side commercial m² 3.78 4473.29
10 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 1015 1055.9 2 2111.8 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. No. 2 1055.9
11 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 3635 3781.49 7.56 28588.06 Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. - 35 mm thickness m² 7.56 3781.49
12 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 6734 7005.38 19.5 136604.91 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of Glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float Glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) m² 19.5 7005.38
13 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 5719 5949.48 9.99 59435.31 Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head Glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) m² 9.99 5949.48
14 Category : Vol - 2 -Chapter -11- Steel and Aluminium Work 1 183 190.37 934.29 177860.79 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. kg 934.29 190.37
15 Category : Vol - 2 -Chapter -8- Finishing 1 382 397.39 320.32 127291.96 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. m² 320.32 397.39
16 Category : Vol - 2 -Chapter -8- Finishing 1 253 263.2 1541.54 405733.33 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. m² 1541.54 263.2
17 Category : Vol - 2 -Chapter -9- Flooring 1 1141 1186.98 852.61 1012031.02 Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm m² 852.61 1186.98
18 Category : Vol - 2 -Chapter -9- Flooring 1 2848 2962.77 87.18 258294.29 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. m² 87.18 2962.77
19 Category : Vol - 2 -Chapter -8- Finishing 1 100 104.03 705.7 73413.97 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. m² 705.7 104.03
20 Category : Vol - 2 -Chapter -8- Finishing 1 138 143.56 17.55 2519.48 Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m² 17.55 143.56
21 Category : Vol - 2 -Chapter -8- Finishing 1 139 144.6 494.01 71433.85 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m² 494.01 144.6
22 Category : Vol - 2 -Chapter -8- Finishing 1 127 132.12 2247.24 296905.35 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m² 2247.24 132.12
23 Category : Vol - 2 -Chapter -8- Finishing 1 53 55.14 320.32 17662.44 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. m² 320.32 55.14
24 Category : Vol - 2 -Chapter -11- Steel and Aluminium Work 1 138 143.56 1269.54 182255.16 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. kg 1269.54 143.56
25 Category : Vol - 2 -Chapter -11- Steel and Aluminium Work 1 565 587.77 319.5 187792.52 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. kg 319.5 587.77
26 Category : Vol - 2 -Chapter -13- Water Supply & Plumbing Work 1 318 330.82 100 33082 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 25 mm nominal dia Pipes m 100 330.82
27 Category : Vol - 2 -Chapter -13- Water Supply & Plumbing Work 1 385 400.52 100 40052 Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - 110mm nominal dia pipes m 100 400.52
28 Category : Vol - 2 -Chapter -14- Sanitary and Bath Fittings 1 4838 5032.97 4 20131.88 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid each 4 5032.97
29 Category : Vol - 2 -Chapter -14- Sanitary and Bath Fittings 1 8642 8990.27 6 53941.62 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern each 6 8990.27
30 Category : Vol - 2 -Chapter -10- Cladding Works 1 2785 2897.24 1.88 5446.81 Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. m² 1.88 2897.24
31 Category : Vol - 2 -Chapter -14- Sanitary and Bath Fittings 1 3082 3206.2 2 6412.4 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps each 2 3206.2
32 Category : Vol - 2 -Chapter -13- Water Supply & Plumbing Work 1 242 251.75 10 2517.5 Providing and fixing PTMT bib cock of approved quality and colour - 15 mm nominal bore, 90 mm long, weighing not less than 93 g No. 10 251.75
33 Category : Vol - 2 -Chapter -13- Water Supply & Plumbing Work 1 131 136.28 20 2725.6 Providing and fixing PTMT stop cock of approved quality and colour - 15 mm nominal bore, 86 mm long, weighing not less than 88 g No. 20 136.28
34 Category : Vol - 2 -Chapter -13- Water Supply & Plumbing Work 1 220 228.87 4 915.48 Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete 1 Nahani trap 4 228.87
35 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 243 252.79 18 4550.22 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. - 125mm No. 18 252.79
36 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 1114 1158.89 2 2317.78 Providing and fixing aluminium die cast body tubular type universal hy- draulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. No. 2 1158.89
37 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 120 124.84 2 249.68 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. No. 2 124.84
38 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 59 61.38 2 122.76 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. No. 2 61.38
39 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 990 1029.9 12 12358.8 Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. No. 12 1029.9
40 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 130 135.24 4 540.96 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete No. 4 135.24
41 Category : Vol - 2 -Chapter -12- Wood and PVC Works 1 44 45.77 12 549.24 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125mm each 12 45.77
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
kw4_bid_document_wi_37152.doc
Tender Document • 3.08 MB
loc format.pdf
Others - LOC • 1.73 MB
technical specifications.zip
Others - specification • 0.27 MB
Royalty Order.pdf
Others - Royalty • 4.03 MB
formats-bldg.xlsx
Others - specification • 0.04 MB
Circular.pdf
Others - Govt Circular • 2.53 MB
Milestones 37152.xls
Others - mile stone • 13.59 MB
Tech Spec doc.zip
Others - specification • 0.27 MB
Road-Bridge Spec doc.zip
Others - specification • 1.19 MB
Debarment circular.pdf
Others - Govt Circular • 0.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].