| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹9.6 L+₹36,060 (3.91%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹10.1 L+₹90,560 (9.82%)Rejected-AOC | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹11.0 L+₹1.8 L (19.6%)Rejected-AOC 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L4 | Rejected-AOC Quoted L4 | |
| 5 | L5₹11.1 L+₹1.9 L (20.6%)Rejected-AOC BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L5 | Rejected-AOC Quoted L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
6 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) Chandigarh
GE(AF) Chandigarh PIN-160003 C/o 56APO
REPAIR TO WINDOW TYPE AND SPLIT TYPE AC INSTALLED AT 12 WING AF STN CHANDIGARH
2023_MES_585107_1
GE(AF)/CHD/T-73/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
Chandigarh
₹30,000
Yes
13 May 2023
9 Mar 2023
12 Apr 2023
9 Mar 2023
6 Apr 2023
23 Mar 2023
9 Mar 2023 - 16 Mar 2023
Amount
REPAIR TO WINDOW TYPE AIR CONDITIONER 1.5/ 2.0 TON OF ANY MAKE AND TYPE
Dismantling & taking out unserviceable sealed unit from existing window type AC 1.5 ton capacity, Supply and fix reciprocating/rotary type company new compressor suitable for make Carrier/ Voltas/ Emersion/ Videocon including cleaning of condenser/ cooling coil, charging of compressor oil, testing, including replacement of new bushes, washers, mounting rubbers, nuts & bolts complete all as specified and directed.
Supply & refilling refrigerant R-22 after testing, rectification of leakage in the system with brazing/ welding complete all as specified and directed
Supply & fix liquid line strainer in repairs complete all as specified and directed
Supply & fixing thermostatic switch for air conditioner in repair complete all as specified and directed. Make: Indfoss/ Denfoss.
Supply & fix PVC condenser fan blade in repair matching with existing type & mode complete all as specified and directed.
Supply & fix blower drum in repair matching with existing type & model complete all as specified and directed.
Supply and fix in repair fan motor 1/5 HP single Phase 230 volts complete with base, nuts, bolts & washers to match with existing type and model complete all as specified and directed. Make: AUE/ Cool Home/ Universal/ Crompton.
Supply & fix in replacement air filter as per existing superior quality (Window type AC 1.5/ 2.0 ton) complete as specified & directed.
Supply and fix in replacement condenser coil 4-row fins type in repair as per existing type & model complete all as specified & directed.
Supply and fix in repair wiring kit as per original specifications with bronze thimbles and code marking complete all as specified & directed.
Supply and fix in repair cooling coil as per existing type and model complete all as specified and directed.
Supply only electronic type remote control suitable for 1.5 TR window type AC as per existing. Make: LG/ Videocon/ Voltas
Supply and fix in replacement panel circuit board electronic for split AC 1.5/ 2.0 ton complete all as specified and directed.
Supply and fix front grill of window type AC of capacity 1.5 Ton complete with knobs, PVC filter etc. all as per sample including taking down old unserviceable grill complete all as specified and directed.
REPAIRS TO SPLIT TYPE AIR CONDITIONERS 1.5/ 2.0 TR CAPACITY ANY MAKE AND MODEL
Dismantling and taking out unserviceable sealed unit from existing split type AC 1.5 ton capacity of make LG/ Emulsion Climate/ Tecumseh/ Carrier/ Videocon and supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/ cooling coil, charging of compressor oil, refrigerant as per existing, including replacement of new bushes, washers, mounting rubbers, nuts & bolts and & testing complete all as specified & directed.
Dismantling & taking out unserviceable sealed unit from existing split type AC 2.0 ton capacity of make LG/ Emulsion Climate/ Tecumseh/ Carrier/ Videocon and supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/ cooling coil, charging of compressor oil, refrigerant R-22 including replacement of new Bushes, washers, mounting rubbers, nuts & bolts and testing complete all as specified & directed.
Dismantling & taking out split type air conditioner of capacity 2.0/ 1.5 Ton of any make/ type from its original location, carrying out maintenance/ overhauling, greasing after cleaning thoroughly with vacuum cleaner, checking of connections, replacement of minor unserviceable parts such as rubber bushes, washers, mounting rubbers, nuts & bolts, clips etc. and testing, complete all as specified and directed. Note: Spare parts required for replacement shall be measured and paid for separately.
Supply and fix in repair contactor single phase 230 volts AC 40 Amps coil range 208/ 240 volts complete all as specified and directed. Make: USHA/ SIEMENS/ L&T.
Supply and fix in repair capacitor 4 MFD, AC 230 volts dry type complete all as specified and directed. Make: EPCOS/ BAJAJ/ USHA/ UNISTON.
Supply & fix in repairs fan motor 1/8 HP single Phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit of make Carrier complete all as specified and directed.
Supply & fix in repairs blower motor 1/20 HP single phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit of make Carrier complete all as specified and directed.
Supply only remote control electronic type suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed. Make: LG/ Videocon/ Voltas.
Supply and fix in repairs panel circuit board electronic for split AC 1.5/ 2.0 ton complete all as specified and directed.
Supply and fix in repairs Tee valve of size 5/8″ and 3/8″ complete all as specified and directed.
Supply and fix, Tee valve of size 3/8″ and 1/4″ in replacement complete all as specified and directed
Supply and fix in replacement wiring kit as per original specification with bronze thimbles and code marking complete all as specified & directed.
MISCELLANEOUS ITEMS FOR REPAIR TO WINDOW TYPE AND SPLIT TYPE ACS
Supply and fix in repairs running capacitor 36 MFD, AC 230 volts grade complete all as specified and directed. Make: EPCOS/ USHA/ UNISTAR/ SIEMENS.
Supply and fix in repairs running capacitor 45 MFD, AC 230 volts grade complete all as specified and directed. Make: EPCOS/ USHA/ UNISTAR/ SIEMENS.
Supply and fix in repairs starting capacitor 100-120MFD complete all as specified and directed. Make: KELTRON/ TESLA/ SIEMENS/ SPEED.
Supply and fix in repairs starting relay box type (suitable for off sizes split type ACs) complete all as specified and directed. Make: SHRIRAM/ RENUTROL/ HI-TECH.
Supply and fix in repairs copper tubing size 5/8″ including gas welding and making leak proof complete all as specified and directed.
Supply and fix in repairs copper tubing size 3/8″ including gas welding and making leak proof complete all as specified and directed
Material and labour for black foam 4mm thick and 50mm wide for insulation, suction and discharge line complete all as specified and directed.
Supply and fix in repairs thermostatic switch of split type air conditioner 1.5/ 2.0 TR complete all as specified and directed. Make: Indfoss/ Denfoss.
Supply and fix in repairs metal plug top 15 Amps, 3 pin 230 volts grade complete all as specified and directed. Make: Anchor/ SSK/ Kalinga/ Havells.
S&F sheet metal enclosure single pole and neutral with 2 pin and earth plug and socket complete with 1 No. single pole 20 Amps 240 volts MCB complete including necessary fixing arrangement and connecting all incoming and outgoing electric connection complete all as specified as directed. Make: INDOASIAN/ HAVELLS/ HPL/ POLICAB/ STANDARD/ ANCHOR BY PANASONIC.
Attending complaints of non functional air conditioner of any make/ model/ type and making them serviceable within 48 Hrs after taking the complaint from the office complete all as specified and directed. Note: Items/ spare parts required to attend the complaint shall be measured and paid for separately under respective item.
Supply & refilling refrigerant R-132, R-134 after testing and rectification of leakage in the system with brazing/ welding complete all as specified and directed.
REPAIRS TO VOLTAGE STABILIZERS ANY MAKE AND MODEL
Taking down unserviceable/ burnt voltage stabilizer of capacity 5KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed.
Taking down unserviceable/ burnt voltage stabilizer of capacity 4KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed.
SANJEEV ENTERPRISES
Sabhyata Electrical and Mechanicals
u and v engineers and consultants
L-7 Primewave Communications
shivrefrigeration
PAWAN KUMAR GOVT. CONTRACTORS
ASHWANI SETHI
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .