Executive Engineer
33/11KV S/S RDC Ghaziabad
Replacement of 33KV Overhead Line from 220KV SS NTPC to Dhoom Manikpur
2023_PVVNL_847066_1
30/ECWD/Gzb/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Noida
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
EE, EUCD (D), PVVNL, Gzb
₹2,600
27 Oct 2023
7 Oct 2023
13 Oct 2023
7 Oct 2023
13 Oct 2023
7 Oct 2023
Carriage of following material from PVVNL Store A.C.S.R. Panther Conductor (from Transmission Substation as per availaibility).
33KV Composite Polymeirc Pin insulator.
Disc fitting B&S type
33KV Polymer Disc insulator B&S 70KN
Complete Stay (GI stay rod 20x1800mm, stay wire 7/8SWG 10Kg, Stay clamp, bolt, nut & washer with concerte grouting.
33KV line isolator
33KV VCB 1250A
33KV CT 400/200/1-1-1A
33KV control & relay Panel differential relay for single T/F
Erection of following Material & Miscellaneous Electrical Works. Installation of 33 KV Isolators: Removal of old & damaged isolator and Assembling & installation of new line/Bus Isolator on existing isolator structure. Adjusting of operating mechanism in proper alignment so as to ensure smooth operation of the same. In case of Line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
Installation of 33 KV VCB Dismantling & Removal of existing 33KV VCB & Assembling and installation of 33 KV VCB on the VCB out door structure on existing plinth. Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes fabrication of addition arrangement for proper fixing and any Civil work if required.
Installation of 33 KV VCB Control Panel for single feeder T/F Control Panel. Dismantling & Removal of existing 33KV CRP Panel Carefully and safely shifting of new 33 KV control panel from outside of the switch gear room to inside of the switch gear room, grouting with anchor bolts in the floor, work also includes cutting & proper finishing of floor if necessary for completion of work. Placing and fixing of panel on foundation, bolts of proper size in proper position and alignment.
Installation of 33 KV C.T.’s: Dismantling & Removal of existing 33KV CT & Installation of 3 Nos. New C.T.’s on existing C.T’s structure. The work includes fabrication for proper fixing, if required to complete the work.
33 KV CT's Junction Box: Dismantling & Removal of existing 33KV CT junction box & Providing & fixing of junction box of size (400x400x150) mm made of M.S. sheet of 16 SWG in between 33 KV CT's & control panel. The work also include making proper connection on the junction box and making all connection in between CT's and control panel complete as per manufacture's panel drawing including testing and commissioning of work etc. complete the work.
Supply and Laying of different size of (2x2.5)mm2control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT’s to CT’s Junction Box, 33 KV CT, 33 KV PT, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment.
Supply and Laying of different size of (4x2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT’s to CT’s Junction Box, 33 KV CT, 33 KV PT, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment.
Supply & Fixing of P.G.Clamps of proper sizes, suitable for panther Conductor for Making Jumpers on Sectional Pole
Laying, spreading, lifting and final sagging of 3 phases ACSR Panther conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel. (Work will also include jumpering on D/P & supply and fixing of binding wire).
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.
Testing & commissioning of newly installed 33KV switchgears / Panels. providing required No. of technicians with proper testing equipments
Removal & Diamantling charges of damaged ACSR Panther Conductor from 33KV line & Making the bundles of removed conductors.
Climbing, Fixing & tightening of extra of 33KV Composite Polymeric Pin insulator on old existing poles in place of broken & damaged Pin insulator.
Climbing, Fixing & tightening of extra 33KV Polymeric Disc insulator B&S 70KN on old existing poles in place of broken & damaged Disc insulator
Climbing, Fixing & tightening of extra 33KV Disc fitting B&S 70KN on old existing poles in place of broken & damaged Disc fitting.
Climbing, Fixing & tightening of extra 33KV Stay on old existing poles in place of broken & damaged Stay.
Safe carriage of old received back material from site to store including loading & unloading at both end.
Krish Traders
M/S PAWAN CONTRACTOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .