Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹9.6 L+₹1.5 L (18.3%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹10.5 L+₹2.4 L (29.6%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹11.5 L+₹3.3 L (41.3%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
16 Nov 2023, 6:00 pmClosed
GE AF ADM AREA
GE AF ADM AREA GWALIOR-474020
REPAIR/MAINT OF INTERNAL ELECTRIFICATION WORKS IN OTM AND CHETAK COMPLEX AREA AND OTHER MISCELLANEOUS WORKS AT AF STATION GWALIOR
2023_MES_624028_1
8357/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE AF ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF ADM AREA
₹40,000
Yes
24 Jan 2024
19 Oct 2023
24 Nov 2023
19 Oct 2023
16 Nov 2023
2 Nov 2023
Amount
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and cost for refixing is deemed to be included in quoted rate. Old unserviceable fittings/fixtures/accessories shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.
Material and labour for point wiring for one light point or one fan point /bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, FRLSH 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE : (i) The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ.
Description all as per item No 2.00 here-in-before but point wring for two way switch.
Description all as per item No 2.00 here-in-before but point wiring for 5 pin switch socket outlet, 5 Amps on independent board.
Description all as per item No 2.00 here-in-before but point wiring for one 5 pin socket outlet, 5/6 Amps on same board with other switch.
Description all as per item No 2.00 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor
Material and labour for point wiring for one light point or one fan point /bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, FRLSH 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete incl taking out old u/s wring from conduit all as specified and directed NOTE :- (i) The quoted rates shall be deemed to be inclusive for provision of covering existing sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ.
Description all as per item No 7.00 here-in-before but point wring for two way switch.
Description all as per item No 7.00 here-in-before but point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.
Description all as per item No 7.00 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
Material and labour for point wiring for one light point or one fan point or bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, FRLSH 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ
Description all as per item No 11.00 here-in-before but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
Description all as per item No 11.00 but point wiring for one 5 pin socket outlet, on same board .
Description all as per item No 11.00 but point wring for two way switch.
Description all as per item No 11.00 but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
M & L for switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified.
M & L for switch flush type single pole two way 5 Amps, 240 volts, white ivory finish complete all as specified
M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified.
S&F switch socket combination multi purpose, 5 Pin 6 amps, flush type with Indicator complete all as specified and directed
S&F switch socket combination multi purpose, 6 Pin 6/16 amps, flush type with Indicator complete all as specified and directed.
M&L for ceiling rose surface Bakelite two to three terminal, 18 x 50 mm complete all as specified.
M&L for lamp holder insulated body with back plate for batten fitting complete all as specified.
Supplying & fixing for switch bell push, flush type, 5 Amps, single pole, one way , 230 volts AC circuit white ivory finish complete all as specified & directed by Engineer-in-Charge.
Supply and fixing bell Ding Dong, AC 230 V, single pole, complete all as specified and directed.
Supply and Fixing step type electronic fan regulator single phase ,230 volt, 100/120 watt . (Size of PT switch )
Supply & Fix in replacement decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose with using copper conductor 50/0.020 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge
S&F in replacement LED mirror light 1X10 Watt complete with lamp all as specified and directed by Engr - in Charge.
S&F in replacementLED bulk head fitting 10 watt energy saving new generation IP 65 luminatre with opel diffuser complete with lamp all as specified and directed by Engr - in Charge.
S&F in replacement LED porch light IP55 surface mounted led porch light in engineering plastic housing with clear prismatic diffuser 6w LED complete with lamp etc and all accessories pre wired and incl. connecting up with twin core twisted flexible copper conductor cable with suitable size. upto the ceiling rose e all as directed by Engineer-in-Charge.
Supply and fixing in replacement Street light fittings LED 35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washers all directed by Engineer-in-Charge.
Dismaintling & Taking out MCB DBs any size, any type and capacity
Supply and fixing of sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
Supply and fixing of sheet metal enclosureDouble door for DB’s 4 way 415 volts, triple pole and neutral supply complete, fixed properly on MS strips and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
Supply and fixing factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 100 /125 Amps as incomer and 12 SP MCBs (or any combination of SP/TP MCBs )outgoings complete all as specified & directed.
Dismaintling & Taking out MCBs and isolator sany size , any type and capacity
S&F MCB single pole 6 to 30 Amps, "C" Curve ,240 Volts complete all as specified
S&F MCB Single pole and neutral 40 Amps, 'C' curve, 240 Volts complete all as specified.
Supply and fix MCB TPN 63 Amps, 'C' curve, 10 KA, 240 Volts complete all as specified.
Supplying & fixing MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 35/36 KA with thermal magnetic release and adjustable overload setting having type DPX 125 conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified & directed.
Taking down sub main wiring any size any type complete from existing PVC/steel conduit surface/concealed all as specified .
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts FRLSH grade in existing steel / PVC conduit, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor all as specified and directed. NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per item No 41.00 here-in-before but 6 Sqmm and 6 Sqmm earth wire
All as per item No 41.00 here-in-before but 4 Sqmm and 4 Sqmm earth wire
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts FRLSH grade in and including conceled PVC conduit, medium grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor all as specified and directed NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per item No 44.00 here-in-before but 6 Sqmm and 6 Sqmm earth wire with PVC conduit 20mm dia medium grade
All as per item No 44.00 here-in-before but 4 Sqmm and 4 Sqmm earth wire with PVC conduit 20mm dia medium grade
M&L for sub main wiring using three single core PVC insulated, unsheathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts FRLSH drawn in and including surface PVC conduit med grade of dia not less than 25mm with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10.0 Sqmm as neutral & earth continuity conductor all as specified and directed. NOTE : Three run of single core PVC cable with two run of neutral & earth conductor and conduit shall be measured as one unit.
All as per item No 47.00 here-in-before but 6 Sqmm and 6 sqmm earth wire.and 20mm PVC conduit
All as per item No 47.00 here-in-before but 4 Sqmm and 4 sqmm earth wire and 20mm PVC conduit
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 10 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as required and directed by Engineer-in-Charge
S&F in replacement 34W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 595x595x70mm complete with LED tube with driver and all accessories specified and directed by Engr -in- Charge.
M & L for replacement of LED Tube light 18/20 watt crystal glass double side connection complete and inclu. taking out all as specified and directed.
M/s Yashika Enterprises
keerti enterprises
Achal Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .