Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | ₹7.0 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹7.4 LRejected-Finance | ₹7.4 L | L2 | Rejected-Finance Reject |
Tender Value
₹7.7 L
EMD Value
₹7,670
Closing Date
27 Jan 2026, 5:30 pmClosed
Shushil Katare
Municipal Corporation Gwalior
Construction of CC Road and Drain in Different Street at near Vaispayan Pathak and Dharamvir Khatik House Samadhiya Colony Ward No.49 Zone No.18.File No.708/25X3/6.
2026_UAD_474583_1
MPGMC/708/25x3/6/jan/2025-26
Open Tender
Civil Works - Others
60 days
Jankarya Department
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹7,670
6 Apr 2026
9 Jan 2026
29 Jan 2026
10 Jan 2026
27 Jan 2026
20 Jan 2026
2.5 Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200.
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.. 2.6.1 All kinds of soil Drain
1.0 Transportation By Mechanical means including loading, unloading and stacking where ever necessary (5km or Part thereof) 1.1 Excavated Earth
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plane and brass threaded fitting i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 15 mm nominal outer dia .Pipes.
20 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
Providing, laying, jointing & testing of following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect. 8 Kg/Cm290 mm dia.
110 mm dia.
Dismantling of manhole including R.C.C. top slab, cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps. 17.27.1.1 upto 45 cm deep
Providing & fixing of precast reinforced cement concrete manhole cover and frame including cost of transporting at site and all material etc. complete 17.23.7 600mm dia. Medium duty
Brick masonry work in 1:3 (1cement :3 sand) with well burnt chimney bricks (crushing strength not less than 40kg /sqcm and water absorption not more than 15%) in sub-structure complete excluding pointing and plastering, as per drawing and technical specifications.
Plastering with cement mortar (1:3) on brick work in sub-structure as per Technical specifications.
Providing and laying non-pressure NP3 class (Medium duty) R.C.C. pipes collar jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand).3.20(a) Size 300 mm dia meter
Providing and laying Cement Concrete grade M-10 Nominal mix 1:3:6 with 40 mm graded crushed stone aggregate, spreading the concrete by shovels mixing shall be in mechanical mixer, compacting by use of pin/plate/screed vibrators including form work by strong steel girders fixed by spikes. Drain
19.1 Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : 19.1.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
6.6 Providing and laying Cement Concrete grade M-20 (Nominal mix 1:1.5:3) with 20 mm graded crushed stone aggregate, mixing shall be in mechanical mixer, laying with paver compacting by use of pin, plate / screed vibrators including form work by strong steel girders fixed by spikes, separation membrane 125 micron thick, i/c cutting of joints @ 4 to 5 m interval & filling it with hot applied bituminous sealant (without dowel bars). (max. thickness 20cm) 6.7 Deduct from Item No.6.2, 6.3 and 6.6 above if paver with electronic sensor is not used and laying, compaction is done by any other method (Note :- The acceptance criteria regarding level, thickness, surface regularity, texture finish, strength of concrete and all other quality control measures shall be the same as in case of machine laid work.) This item is to be executed with Prior written permission of Engineer- in-charge
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_557958.pdf
techsummary_557958.pdf
finance_557958.pdf
BOQ Comparative Chart
xlsx
finsummary_557958.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
Document.pdf
Tender Documents • 3.26 MB
BOQ_557958.xls
BOQ • 0.27 MB
Drawing.pdf
Additional Documents • 3.37 MB
Estimate.pdf
Additional Documents • 4.14 MB
Download all tender documents and submit your bid