Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹33.0 L+₹83,445.50 (2.60%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹33.0 L+₹90,060 (2.80%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹36.8 L+₹4.7 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
Tender Value
₹40.5 L
EMD Value
₹81,100
Closing Date
30 Jun 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR - 63 OF 2019-20 SPECIAL REPAIRS TO BUILDING NO. T-776(A) TO T-776(H) AND P-814(A) TO P-814(F) (OR MARRIED ACCOMMODATION) AT MILITARY STATION FARIDKOT
2020_MES_317014_1
CA NO. CWE SGNR - 63 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
FARIDKOT
Class D
Category a(i)
10 documents required · 10 mandatory
₹500
GE FARIDKOT
₹81,100
Yes
14 Aug 2020
26 May 2020
2 Jul 2020
26 May 2020
30 Jun 2020
16 Jun 2020
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles(if any) to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
S&F Glazed ceramic tiles (coloured tiles) in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 on other than fair face of brick work complete all as specified and directed by Engineer-in-Charge.
S&F Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles 15mm thick screed bed or bedding layer CM 1:4 for laying finishes complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 6 here-in-before but as in vertical surfaces such as skirting, dados & risers to steps etc complete all as specified and directed by Engineer-in-Charge.
M & L for machine cut kota stone slab flooring 20-25mm thick over 20mm cement screed (CM 1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M & L for kota stone slab 20-25mm thick in skirting laid over 15mm cement screed (CM 1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 20mm (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in screed bed of cement mortar (1:4) 15mm thk including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 50mm thick type C2, 1:3:6 using 20mm graded aggregate as in plinth protection/path finishing surfaces even and fair (without using extra cement) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone wall etc. including raking out of joints, hacking for keys and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and Preparation of new surfaces plastered or unplastered and applying two coat of white wash on wall over on coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and Preparation of new surfaces plastered or unplastered and applying two coat of distemper oil emulsion on wall over on coat of primer over wall care putty on finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of old surfaces (complete removal) plastered or unplastered and applying two coat of distemper oil emulsion on wall over on coat of primer over wall care putty on finished surface complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including preparation of newly plastered or unplastered surfaces and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement including Preparation of new surfaces plastered or unplastered and applying two coat of white wash on ceiling over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L repair to RCC fillet beams in ceiling with cement mortar 1:3 over applying a coat of neat cement slurry @ 3kg/sqm and applying two coat of white wash including taking out old plaster complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement plaster 1:4 on surface other than fair face of brickwork or stone masonry surfaces or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp complete all as specified and directed by Engineer-in-Charge. : 1. SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non-moving cracks having width upto 5 mm must be filled with Polymer based crack filler. 2 APPLICATION: Apply the first coat of Roff Hydamp with a paintbrush directly on the prepared surfaces. Allow to dry for a minimum 2-3 hrs. Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Roff Hydamp on the entire surface.
M&L for preparation of old surfaces plastered or unplastered and applying two coat of white wash on ceiling over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plastered or unplastered surfaces of wall by mechanical method i.e. electric grinder and applying two coat of distemper oil emulsion white/tinted with a wall care putty finished surface over one coat of primer by mechanical roller / hand roller complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by mechanical method i.e. Electric grinder and applying two coat of distemper oil emultion white/tinted with a wall care putty finished surface over one coat of primer using mechanical roller / hand roller complete all as specified and directed by Engineer-in-Charge.
M&L Preparation of new surfaces plastered or unplastered and applying two coat of white wash on wall over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of white wash over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plastered or unplastered ceiling surfaces and applying two coat of distemper oil emulsion white/tinted on wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of distemper oil emultion white/tinted with a wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L complete removal of existing treatment such as white wash, colour wash, synthetic enamel paint etc of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge. Note: Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge. Note : Payment for providing grooves shall be made separately.
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-Charge.
S&F in repair MS powder coated decorative drapery rod (colour as approved) of 20mm dia approved pattern & design including decorative knobs (wall side and free side) & powder coated mild steel flat iron brackets fixed with steel screws & PVC rawl plugs / grips complete all as specified and directed by Engineer-in-Charge.
S&F in repair Rotational moulded polythylene 500 capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including PVC float valve 20 mm bore, high pressure with polythene ball & float including dismantling of old water tank complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing of dia 15mm alongwith connections, in any position complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore GI tubing medium grade with all fittings fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
Fixing only tube tubes of bore dia 15mm, any grade, to walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing of dia 20mm alongwith connections, in any position complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore GI tubing med grade with all fittings fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
Fixing only tube tubes of bore 20mm, any grade, to walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge.
S&F of 40mm bore galvanized iron tube medium grade with all fittings fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe with shower arm 15 mm size, 195mm long with bend of 45 degree with flange complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, 15mm fancy type chromium plated pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm fancy type chromium plated concealed type stop valve, screwed down high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S&F towel rail 450mm long of PTMT fixed with and including chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F cast iron or mild steel peg set 175mm to 250mm with hooks fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, lime concrete bedding, with 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level ,white, with inlet ball valve, float and handle including brakets, 100mm CI 'P’ trap, Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern and PVC connections 15 mm size, 450 mm long with PTMT nuts, etc alongwith 15 mm fancy type chromium plated angle valve, screwed down high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash basins, size 550x400mm white flat back including cutting for and pinning in ends of brackets or erecting stand including 32mm waste fittings and waste pipe, brass CP for galzed ware basins, etc. with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed with 15mm fancy type chromium plated pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, long screwed shanks and flynuts, screwed for iron pipe and chromium plated with long screwed shanks & fly-nuts, flange end and PVC connections 15 mm size, 450 mm long with PTMT nuts, etc. alongwith 15 mm fancy type chromium plated angle valve, screwed down high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash basins, size 550x400mm white flat back including cutting for and pinning in ends of brackets or erecting stand including 32mm waste fittings, waste pipe and 02 Nos PVC connection chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engineer-in-Charge.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel plate rack 1.25 mm thick of size of 900mm x 775mm x 250mm incl angle iron brackets and taking down of 19 mm thick particle board shelf and removal from site complete all as specified and directed by Engineer-in-Charge.
M&L in repair CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc complete all as specified and directed by Engineer-in-Charge.
S&F cast iron branch pieces, 100mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F cast iron branch pieces, 75mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F 75mm cast iron vent cowls complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete or PVC SWR drain pipes 110mm/100mm/75mm, jointed in cement mortar and taking out of trenches or from embeddment from wall, if required complete all as specified and directed by Engineer-in-Charge.
S&F Cast Iron soil, waste and vent pipes of 100mm, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 64 here-in-before but except pipe of 100mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in 100mm dia CI bends, diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge.
S&F Cast Iron soil, waste and vent pipes of 75mm, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 67 here-in-before but except pipe of 75mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in 75mm dia CI bends, diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge.
S&F CI vent cowl 100 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bend any radius 110 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) 'P' trap of 125 / 110mm bore complete all as specified and directed by Engineer-in-Charge.
Taking down of chowkats or frames exc 1.5 Sqm but n exc 4 sqm EACH with shutters (without taking of shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of door shutters in same opening exc. 1 sqm and n exc 2 sqm complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type B1 (using 20mm graded aggregate) as in benching, haunching around man hole cover including necessary form work and moulds complete all as specified and directed by Engineer-in-Charge.
S &F of Solid PVC Door Frame single side prelam PVC sheet used instead of plain colour PVC Sheet and edge will be painted to match with prelam sheet. of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, egdes will be painted to match printed sheets, in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S & F Factory made solid PVC Moulded door,shutteer, 28 to 30 mm thick stiles with particle board ,2,4 or 6 raised panel design with 2 mm thick moulded prelam PVC sheet on the front face and 2 mm plain colour PVC sheet on back side and supply and fixing in frame at site as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F of 35 mm thick 2nd class hard wood plain framed panel shutters (any number of pannels) with pannels of timber flat on both sides (feather edges) or of vaneered partical board medium desnsity, wood partical board with commercial face veneers fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F 25 mm thick flush shutter solid core construction with block board core and plywood face panels, commercial type on both side complete all as specified and directed by Engineer-in-Charge.
S&F for (125X60) mm pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges, lock strike plates etc. complete all as specified and directed by Engineer-in-Charge.
S&F for (105X60) mm pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges, lock strike plates etc. complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C0 using (12.5mm graded aggregate) as in back filling of pressed steel frames, bed blocks, coping, fixing of hold fasts etc including necessary formwork complete all as specified and directed by Engineer-in-Charge.
S&F pressed steel rectangular frames for built in cup board doors, made out of M.S. sheet 1.25mm thk with girth of frame 185mm including necessary MS rawl plugs and fixing 75mm long butt hinges med wt. cold rolled M.S. etc. including two coats of synthetic enamel paint over a shop coat of zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
S&F pressed steel door shutters including stiffeners made out of M.S. sheet 1.25mm thk cut to size, holes punched and welded seams including bending or turning up all around, mitred angle, one No. of locking arrangement etc. and applying 2 coats of synthetic enamel paint over a shop coat of zinc chromate primer all as per Godrej pattern complete all as specified. (Note: (i) Measurement of door shutter shall be taken as exact size of cup board opening (excluding frame) . (ii) Stiffeners of 150mm girth and height equal to height of shutter made to shape. Cost of stiffeners shall be deemed to be included in rate complete all as specified and directed by Engineer-in-Charge.
M&L block boards 18/19mm thick, grade 2 quality, interior grade, decorative type with decorative face veneer on one face fixed with screws to frame-work complete all as specified and directed by Engineer-in-Charge.
S&F of 100 mm long butt hinges, medium weight, cold rolled, mild steel and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm long butt hinges, medium weight, cold rolled, mild steel and fixed complete all as specified and directed by Engineer-in-Charge.
S&F of Aluminium anodized barrel tower bolt 150 mm size of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasps staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
S&F of Aluminium anodized cast type handle 125 mm size complete all as specified and directed by Engineer-in-Charge.
Taking down of chowkats or frames n. exc 1.5 Sqm with shutters (without taking of shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
S&F in repair Factory made box type mild steel ventilator with sash bars dovetailed or welded and with one shop coat of zinc chromate primer ready for wire mesh/glass pan fixing complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth 0.56mm nominal dia wire and average width of aperture 1.25mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed by Engineer-in-Charge.
M & L for water proofing treatment to RCC sunken slab as specified below complete all as specified and directed by Engineer-in-Charge.:- (a) Rendering 15 mm thick in cement mortar 1:3 using water proofing compound on raised vertical surfaces after demolition of PCC., (b) Cleaning the surface with wire brush / coir brush, removing loose material like dust particles, dirt etc., (c) Creating fillet covering of 50 x 50 mm with polymer modified mortar on the junction of slab and wall., (d) Apply first coat of two component modified polymer coating on the horizontal and vertical surface upto 300mm above wall surface., (e) Provision of Polyester reinforced coated net of 45 g/m2, 2.5 mm x 2.5 mm immediately on above coating., (f) Apply second coating of two component modified polymer coating after 72 hrs upto 300mm above wall surface., (g) Laying concrete 1:4:8 over the coating as per requirement., (h) Joining the sanitary pipes with the waterproofing tape having bridging ability of more than 1.5 mm, (j) Filling the gap between the wall opening and sanitary pipe with non shrink cementatious grout.
S&F sheet glass frosted 3mm thick ordinary quality as in glazing in Square not exceeding 0.5 Sqm in each pane and fixed in position with oil putty complete all as specified and directed by Engineer-in-Charge.
S&F in repair factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete with glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F in repair factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete without glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass plain 3mm thick ordinary quality as in glazing in Square not exceeding 0.5 Sqm in each pane and fixed in position with oil putty complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint to steel surfaces complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new or previously untreated surface of wood or wooden based surfce any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete(Unreinforced) of roof, any description and in any position not otherwise specifically provided for and cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cement mortar (1:3) with water proofing compound on raised vertical surface complete all as specified and directed by Engineer-in-Charge.
Laying concrete( 1:1.5:3) using 12.5mm aggregate over the top of sunken slab made to a slope of 1:20 towards outlet pipe of avg. thk. 25mm admixed with water proofing compound and creating a fillet coving of 50mm X 50mm on the junction of wall and floor surface, as per specification of manufacturer complete all as specified and directed by Engineer-in-Charge.
Preparation and cleaning of surface and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 Kg/Sqm over a coat of bituminous primer @ 0.30 Ltrs / Sqm complete all as specified and directed by Engineer-in-Charge.
Laying 3mm thick APP based polymeric membrane minimum weighing 3Kg/sqm , (mineral finish) reinforced with non woven polyster fabric, over bituminus surface by torch application. The overlapping while torching shall be 75mm on longitudinal direction and 100mm on the transverse direction complete all as specified and directed by Engineer-in-Charge.
Laying concrete (1:5:10) using broken brick aggregates over the membrane complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10 mm thick in cement plaster 1:4 with liquid WPC on roof finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only water proofing compound ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for roof treatment as specified below and complete all as specified and directed by Engineer-in-Charge. :- (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brushing or high speed water jet. Surface should be feree from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal / Epoxy. Primer / ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 Kg / Sqm (0.20 Kg BTD + 0.20 Kg Water) (d) Laying polyster reinforced fiber net / 50 GSM Geotextile mesh, upto 300mm on walls. (e) Applying three coats of HydroShield PUD microfiber reinforced UV resistant polyurethane (solid content 68%) / Damp Proof Ultra UV Stable fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers (Solid content 55%) / SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%) / Single Component Elastomeric Liquid Membrane Shaliurethane BTD White / Coloured (Elongation 400% + 50, Solid Contents > 80% and Specific Gravity @ 30 OC 1.5 + 0.03) @ total 2.00 Kg Per Sqm in two coats of maintaining thickness of 1.5mm with paint brush / roller upto 300mm on walls. Make : Dr. Fixit / Asian / STP
S&F Salt-glazed stoneware gully traps, size 150mm x 150mm, square or round mouthed, type 'P' complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft loose soil not exceeding 1.5m deep and 1.5m wide, for foundation etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks (old size bricks) straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 119 here-in-before but except bricks complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, sub base & mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L 150mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
S&F Reinforced concrete pipes class NP-2 laid and jointed complete with collar of size 150mm (internal dia) complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate )as in concrete bed to drain pipes, including packing under and haunching against the sides of pipes after they are laid, jointed and tested bore of pipes 150mm NP-2 pipes complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2) round pr 3/4 section in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Hardcore of broken brick aggregate gauge not exceeding 63mm deposited spread and leveled in layers not exceeding 15 Cm thick watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L Mild steel framed work of E-165(Fe-290) as in grills/guard bars shouldered with steel windows/ventilators frames,Cooler Stand, Ladder etc. including red oxide primer coat complete all as specified and directed by Engineer-in-Charge.
M&L machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
Providing factory made precast cement concrete solid block type B1, 1:2:4 (20mm graded aggregate) as in kerb stone of any size/thickness setting in cement mortar 1:4 for path edgings etc, embedded in positon including all necessary excavation, tamping ground arround blocks and removal of rubbish/surplus soil etc. complete all as specified and directed by Engineer-in-Charge.
Preparation of new concrete / plastered surface of any description, over 10cm width or girth and applying two coats of plastic emulsion paint including priming paints complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding. 25cm thick each complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as Switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface complete all as specified and directed by Engineer-in-Charge
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers / MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes including painted with one coat of red oxide primer all around for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem / Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for one light point / call bell point / fan point to be controlled by one number one way point switch complete all as specified and directed by Engineer-in-Charge
Switch socket combination 3/5 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 1.5 Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer-in-Charge
All as per item No. 136 here-in-before but on same board complete all as specified and directed by Engineer-in-Charge
One bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
One light point controlled by two 2-ways switches, with cables 1.5 Sqmm size complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 2.5 Sqmm single core multi standed copper conductor PVC insulated and unsheated, flame retardant Low Smoke (FRLS) cable of 3/6 pin 15 Amps socket outlet controlled by one switch on independent board with and including 2.5 Sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed by Engineer-in-Charge.
S&F bell AC 230 Volts single pole Ding Dong type complete all as specified and directed by Engineer-in-Charge.
S&F switch bell push button type 6 Amp single pole complete all as specified and directed by Engineer-in-Charge. Cat Part No F 902 for switch and F-919 for Switch frame of Make : SSK or equivalent in Legrand / Hager.
M&L for switch piano flush type single pole two way, 5/6 Amp fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan regulator 0-4 steps step 450 W hum free including 6A socket frame and including connections complete all as specified and directed by Engineer-in-Charge. Cat Part No. F 911 for regulator and F-920 for socket frame of make SSK or equivalent in Legrand / Hager.
S&F switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 900 for switch and F-919 for Switch frame of Make : SSK or equivalent in Legrand / Hager.
S&F socket 5 pin shuttered 6A 250 V AC including 6 A Socket frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 904 for socket and F- 920 for Socket Frame of Make SSK or equivalent in Legrand / Hager.
S&F Switch single pole mini with porcelain Base 16 A 250 V AC with ISI mark including switch frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 954 for Switch and F-919 for Switch Frame of Make SSK or equivalent in Legrand / Hager.
S&F socket 5 pin shuttered 6A/16Amp 250 V AC i2 in 1 ncluding 16 A Socket frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 951 for socket and F- 920 for Socket Frame of Make SSK or equivalent in Legrand / Hager.
S&F Ceiling rose having three terminals polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED mirror light fitting 1 x 5 watt including LED tube complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting 1 x 20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
S&F Decorative wall light fixture made up half cut frosted glass suitable for and including 1 x 9 W LED Lamp with B-22 base complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lamp holder with1 x 10 watt LED lamp B-22 base complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
S&F 1 x 10 Watt LED Bulk head luminaries with lamp, holders, 850 lm with an efficacy of 85 lm/w etc complete with accessories pre wired and including connecting with flexible cord 3 core 0.5 sqmm complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of ceiling fan 1200 mm sweep complete AC single phase 230 Volt 50 HZ connecting with new flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including spry painting, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.complete matching with existing colour and all hanging arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Exhaust fan light duty AC single Phase 230 V / 240V 50 Hz of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of Storage water heater 25 ltrs cap vertical mounting AC 230 Volts including connecting cord and plug, safety valve, nuts and bolts, complete including grouting of nuts and bolts complete all as specified and directed by Engineer-in-Charge.
M&L for distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S & F in repairs of MCB distribution board double Door of sheet metal TPN 4 way with 415 Volts complete with and including MCCB 63 Amps,16KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 40 Amps S & F as in replacement of MCB distribution board double Door of sheet metal TPN 6 way with 415 Volts complete with and including MCCB 63 Amps,16KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Isolator suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 63 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, Sub main wiring with 2 single core 6 Sqmm PVC insulated flame retardant low smoke cable with multistranded copper conductor cable ISI marked in and including suitable size of PVC conduit medium quality conforming to 3537 Part-I & conduit accessories with and including independent PVC insulated one single core 6 Sqmm flame retardant low smoke un-sheathed and multistranded copper earth wire complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring., (b) Three lengths of single core 6 Sqmm cable and suitable size of PVC conduit will be measured as one length)
Supply & laying in repairs, LT under ground cable XLPE insulated armoured and PVC sheathed 4 core 16Sqmm cross sectional area heavy duty electric with aluminium conductor 1100Volts grade in trenches / passing through pipes including including cable connecting lugs, glands, jointing fixing materials after taking out exisisting unserviceable cables complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry and clean fine river sand for underground cable 8cm before laying the cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge
Supplying and laying well burnt clay bricks old size class 'B' laid dry and flat for protection over the cable with equal to the length of cable, complete all as specified and directed by Engineer-in-Charge.
S & F PVC sleeves for connection of conductor to MCB DB any type any size complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth not less than 1.5 Mtr below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles upto equipment and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 20mm dia upto earthing test point / equipment fixed with 2 Nos. of mold steel clamps made out of 25mm x 3mm flat iron and preforated water pipe 20mm dia galvanized iron pipe heavy grade 2.25 Mtr long and top with socket and plug and bottom connected to earth plate by silt and two bolts / nuts / washers complete with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and cast iron cover with frame all as shown on electrical plate No. 3 of MES Schedule Part - I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Note : (i) Outer edge of earth pit will be 1 Mtr away from the outer edge of PCC Chamber. (ii) Galvanized iron earth wire 4mm dia upto earthing test point / equipment is encluded in this item. (iii) Water pipe shall be provided in slainting position. (iv) 20mm dia galvanized iron pipe for watering shall be provided with a socket and plug and shall be 10cm above the ground level.
S&F in repairs, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing LED street/Security light fitting of 25 watt including LED lamps complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall with 1.2 mtr long GI pipe 32 mm dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report complete all as specified and directed by Engineer-in-Charge.
Supply, installlation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, suitable for to operate on AC 220 V single phase having heating element of 2 KW capacity and high thermal cutout, energy saving BEE 5 star rating including fixed along walls and connecting up inlet/ outlet with cold water PVC connection pipes and electric connections with copper cable 3 core and 3 pin plug 15/16 amp, including making good the distributed surfaces matching with existing complete all as specified and directed by Engineer-in-Charge. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 80,236.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 37 & 38(R) (Schedule of Credit) of Tender document
M/s Surjit Singh and bros
M/S RAJESH KUMAR and CO.
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .