Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹23.0 L+₹18,401 (0.81%)Rejected-Finance | L2 | Rejected-Finance HIGHER QUOTED BIDDER | |
| 3 | L3₹23.5 L+₹73,700 (3.24%)Rejected-Finance CB 288 RING ROAD NARAINA NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | L3 | Rejected-Finance HIGHER QUOTED BIDDER | |
| 4 | L4₹23.9 L+₹1.1 L (4.95%)Rejected-Finance | L4 | Rejected-Finance HIGHER QUOTED BIDDER | |
| 5 | L5₹25.5 L+₹2.7 L (11.8%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L5 | Rejected-Finance HIGHER QUOTED BIDDER |
Tender Value
₹35.9 L
EMD Value
₹71,800
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jaisalmer
HQ CWE (AF) Jaisalmer
PROVN OF STABILIZERS FOR MAFI PROJECT AT FBSU AT AF STN UTARLAI
2020_MES_346042_1
80100/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Utarlai
Class D category b (I)
7 documents required · 7 mandatory
₹500
GE (AF) Utarlai
₹71,800
Yes
4 Sept 2020
19 May 2020
18 Jul 2020
19 May 2020
16 Jul 2020
29 Jun 2020
60 days
Amount
Supply, installation, testing and commissioning of servo voltage stablizer (conforming to BIS 9815:1994) for automatic operation, three phase, naturally oil cooled, copper wound, metallic body duly powder coated with lifting hooks 2 nos, digital display type relay free smooth and silent operation indoor type of capacity 630 KVA complete all as specified and directed. (i) Applicable standard - IS 9815:1994 (ii) Input Voltage range -300-480 Volts, 3 Phase, 50 Hz, 4 wire & earth (iii) Output Voltage - 415+-1% VAC accuracy, 3 phase, 50 HZ 4 wire & earth (iv) Line regulation - Line to load regulation 1% (v) Type of load - Three phase unbalanced type (vi) No distortion in wave form. (vii) Correction range - 8V/Sec for single phase and 13 V/Sec for phase to phase. (viii) Efficiency - Above 95% (ix) Response time not to be exceed 20 mili second. (x) Noise level - <55 db at a distance of 1 meter (xi) Monitoring and Electronic circuit - Microcontroller and DSP based electronic card with inbuilt LCD Display, Input L/L and L/N Voltage monitoring, output L/L and L/N Voltage monitoring, Load current phase wise monitoring, Input line indication. (xii) Protection - Input 3 pole MCCB with shunt release coil for high/low voltage protection and overload and short circuit protection, output 4 pole change over switch for bypass, 10 Sec on time delay, RF filter, spike buster, reverse phase protection, single phasing protection, Earth protection & Neutral protection circuit, spike & surge protection. Note : 1. Amount for 1st filling of transformer oil up to level deemed to be included in quoted rates. 2. XLPE unamoured 1100 volts copper conductor cable of 300 Sqmm single corer (four run of length 20 RM each) with copper lugs (from transformer to voltage stabilizer to APSC at MAFI PS-I) required as per site will be included in quoted rates.
Supply, installation, testing and commissioning of servo voltage stabilizer (confirming to BIS 9815:1994) for automatic operation, three phase, naturally oil cooled, copper wound, metallic body duly powder coated with lifting hooks 2 nos, digital display type relay free smooth and silent operation indoor type of capacity 200 KVA complete all as specified and directed. (i) Applicable standard - IS 9815:1994 (ii) Input Voltage range- 300-480 Volts, 3 phase, 50 HZ, 4 wire & earth. (iii) Output Voltage - 415+-1% VAC accuracy, 3 phase, 50 Hz 4 wire & earth. (iv) Line regulation - Line to load regulation 1%. (v) Type of load - Three phase unbalanced type. (vi) No distortion in wave form. (vii) Correction range - 8V/Sec for single phase and 13 V/Sec for phase to phase. (viii) Efficiency - Above 95% (ix) Response time not to be exceed 20 mili second. (x) Noise level - <55 db at a distance of 1 meter (xi) Monitoring and Electronic circuit - Microcontroller and DSP based electronic card with inbuilt LCD Display, Input L/L and L/N Voltage monitoring, output L/L and L/N Voltage monitoring,Load current phase wise monitoring, Input line indication. (xii) Protection - Input 3 pole MCCB with shunt release coil for high/low voltage protection and overload and short circuit protection, output 4 pole change over switch for bypass, 10 Sec on time delay, RF filter, spike buster, reverse phase protection, single phasing protection, Earth protection & Neutral protection circuit, spike & surge protection. Note : 1. Amount for 1st filling of transformer oil up to level deemed to be included in quoted rates. 2. XLPE unarmoured 1100 volts copper conductor cable of 70 Sqmm four core (length 20 RM) with copper lugs (from transformer to voltage stabilizer to APSC at MAFI PS-II) required as per site will be included in quoted rates.
Supply, installation, testing and commissioning for automatic phase sequence corrector automatically correct input supply reverse phase also protection against single phasing voltage unbalancing, low voltage, high voltage with time delay of rating 600 KVA type complete all as specified and directed. It includes following:- (i) Control unit of capacity 600 KVA for operation- 02 Nos (ii) Contractors suitable for 600 KVA rated current- 02 Nos (iii) Interlock arrangement for contractors of 600 KVA – 02 Nos (iv) Copper busbar suitable for 600 KVA rating – 12 Nos (v) Connectors for Neutral, Control unit and LED – 02 Nos (vi) Indicator lamp for indication of ON – 04 Nos (vii) Toggle switch, 3 way for ON/OFF/ON 10 Amps – 02Nos Note:- XLPE unarmoured 1100 volts copper conductor cable of 300 sqmm single core (four run of length 10 RM each) with Copper lugs(from transformer to voltage stabilizer to APSC at MAFI PS-I) required as per site will be included in quoted rates.
Supply, installation, testing and commissioning for automatic phase sequence corrector automatically correct input supply reverse phase also protection against single phasing voltage unbalancing, low voltage, high voltage with time delay of rating 200 KVA type complete all as specified and directed. It includes following:- (i) Control unit of capacity 200 KVA for operation- 02 Nos (ii) Contractors suitable for 200 KVA rated current- 02 Nos (iii) Interlock arrangement for contractors of 200 KVA – 02 Nos (iv) Copper busbar suitable for 200 KVA rating – 12 Nos (v) Connectors for Neutral, Control unit and LED – 02 Nos (vi) Indicator lamp for indication of ON – 04 Nos (vii) Toggle switch, 3 way for ON/OFF/ON 10 Amps – 02Nos Note:- XLPE unarmoured 1100 volts copper conductor cable of 70 sqmm single core (four run of length 10 RM) with Cu lugs ( From APSC to ACB Panel at MAFI PS-II) required as per site will be included in quoted rates.
M& L for chemical earthing complete with plate 90cm X 60cm 5mm thick copper plate electrode buried direct in ground vertically not less than 3.15 mtr deep below ground lever with connected to copper strip of size 32 X 6 mm as earthing lead by means of bolts nut and brazing, check nut and washers all as directed to test point including necessary excavation and earth work (in any type of strata) and providing charcoal dust 250 Kgs common salt 200 Kgs magnesium sulphate 100 Kgs and all around the plate 15 cm depth and wide and upto 2 mtr height continuous layers, balance pit will be filled with vegetable soil to ground level including watering pipe medium grade of 20 mm dia and 50 mm dia pipe medium grade for earth pit strip protection up to 7.5 mtr PCC (1:3:6) type C1 chamber, cast iron chamber frame heavy duty and RCC pit cover complete all as specified and directed.
Supply and fix test point terminal box made of gun metal or phosphorus bronze 75X75X25 mm, drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex, head screw including jointing and jointing materials complete including taking out old test point terminal box complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall/on suitable insulators, on batten or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to pole on any other indicated situation of size 20X3 mm copper strip complete all as specified and directed.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm X 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete all as specified and directed.
CHIME ELECTRONICS
Electro Tech Systems
Godara Construction and General Suppliers
RASAM ENGINEERING COMPANY
M/s Pankaj Enterprises
Jagdish Prashad and Company
MORESHWAR ELECTRICALS CORPORATION
Anil Builders
Hariom Construction Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .