COMPLETION OF BALANCE LEFT OVER WORK FOR PROVN OF OTM ACCN AMENITIES ALLIED FACILITIES FOR COAST GUARD RHQ NE AND OTHER CG UNITS AT 05 ACRES LAND AT RAJARHAT KOLKATA (RISK COST CONTRACT AGAINST CA NO CEKZ/KOL/23 OF 2018 19)
2022_MES_543307_1
CE CG / VIZ /KOL / TOKEN11 OF 2022-23
Open Tender
Civil Works
900 days
Kolkata
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer I CG and N Kolkata
₹15 L
Yes
1 Dec 2022
4 Aug 2022
15 Oct 2022
4 Aug 2022
13 Oct 2022
30 Sept 2022
Amount
Sch 'A' Part-I (BuIlding Works) Note : This Sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Completion of incomplete/leftover work for construction of a Block of (G+15) consisting of Single living accn, recruiting office, office accn, MI room, store rooms, JCO’s mess, OR institute, library, servant qtrs etc with all circulation areas, lift area, passage etc per line plan, fitting and fixtures etc for RHQ (NE), ICGS Kolkata, CGRPT Kolkata, complete all as specified and as shown in drawings.
Completion of incomplete/leftover work for construction of a Block of Guard room (G+1) for RHQ (NE) and ICGS Kolkata complete all as specified and as shown in drawings.
Completion of incomplete/leftover work for construction of a Block Store room for RHQ (NE), ICGS Kolkata and CGRPT Kolkata complete all as specified and as shown in drawings.
Construction of Parade cum enrolling shed complete all as specified and as shown in drawings.
Completion of incomplete/leftover work for construction of Sub Station Bldg complete all as specified and as shown in drawings
Construction of Sentry Post complete all as specified and as shown in drawings
Construction of Incinerator complete all as specified and as shown in drawings
Construction of Flag staff complete all as specified and as shown in drawings
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II.
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-III.
Lumpsum price worked out by the tenderer for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part-IV.
Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for EARTHWORK, EXCAVATION, SITE CLEARANCE AND DEVELOPMENT as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for ROAD/ PATH /CULVERT/ HARDSTANDING as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for AREA DRAINAGE & SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-X
Sch 'A' Part- II (A) INTERNAL WATER SUPPLY Note : This Sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
S&F 15mm bore chromomum plated wall mixture with provision for overhead shower with flange screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F 25mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F 50mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
Supply and fixing Forged brass Pressure reducing valve for 15mm dia pipe in vertical water supply line to reduce the Velocity as specified.
Supply and fixing Forged brass Pressure reducing valve for 20mm dia pipe in vertical water supply line to reduce the Velocity as specified.
Supply and fixing Forged brass Pressure reducing valve for 40mm dia pipe in vertical water supply line to reduce the Velocity as specified.
Supply and fixing Forged brass Pressure reducing valve for 50mm dia pipe in vertical water supply line to reduce the Velocity as specified.
Supply and fixing CP two way Bib tap 15mm bore, srewed diwn for iron pipe or brass ferrules and fixed.
Supply and fixing CP health faucet with 01 meter flexible connector pipe 15mm size PTMT nuts.
Supply and fixing of forged brass pressure reducing valve for 80 mm dia pipe in vertical water supply line to reduce the velocity as specified.
S&F 80mm bore sluice valve with flanged ends
S&F 150mm bore sluice valve with flanged ends
Sch 'A' Part- PART III (A) INTERNAL ELECTRIFICATION Note : This Sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable mult-istranded conductor 1100 volts grade controlled by one 1 way modular switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multi-stranded conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including ERW concealed steel conduit and terminated to modular box. (Note: Red/Blue/Yellow coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (all earth circuit of the wiring will be finally terminated through distribution board and to Main LT panel board installed on that floor)
All as per item No 12.01 above but for 2 way switches for stair case.
All as per item no 12.01 above but with 2.5 sqmm copper wire and 2.5 sqmm copper earth wire to be controlled by MCB from UPS distribution board not by switch board (i.e. switch not required)
All as per item No 12.03 but loop from the point made against item No 3. (Note item No 3 & 4 are separate wiring circuit and to be connected with UPS DB)
All as per item No 12.01 here-in-before but for 5 pin 6 Amps socket outlet on the independent board with 1.5 sqmm cable complete as specified and directed.
All as per item No 12.01 here-in-before but for one 5 pin 6/16 Amps socket outlet on independent board with 2.5 Sqmm PVC insulated unsheathed copper cable multistrand conductor 1100 volts grade and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
M&L for 6A indicator lamp for switchboard, Make-Crabtree, model Athena, cat No-ACPITIW060/LEGRAND/ANCHOR
M&L for blank plate for Switch Board. Make-Crabtree, Cat No-ACAPXBWX01/LEGRAND/ANCHOR
M&L for GI box for switch socket mounting, 8 module, Make-Crabtree, Cat No-ACTXMIIX08/LEGRAND/ANCHOR
M&L for Brush Less DC (BLDC) ceiling fan with the following specifications: - (i) Motor: - Brushless DC 32 W, with operating voltage 140V-240V AC, 50 Hz. (ii) Max RPM: - 360 RPM (iii) Sweep: - 1200mm (iv) Remote control operated (v) colour:- white (vi) 5 STAR energy saving rating. Make: - Surya, model- SS-32/Havells/Bajaj/CG
M&L for exhaust fan 250mm sweep with polycarbonate blades flush mounting, square type body case, operated on 230V, single phase Ac, 50 Hz complete with connection. Make:- Havells/Bajaj/CG
Supply and fixing distribution board (DB) SPN 6 ways, with bus bar 200 A rating 230 Volts, double door, recessed with wall surfaces by chase cutting and making good disturbed surfaces of wall complete all as specified and as directed by the Engr-in-Charge.
M&L for single pole blanking plate for distribution board
Supply and fixing surface & wall mounted LED Bulk head light fittings with 9/10 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate/glass cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
M&L for 6W LED "EXIT" signage of box size 325X425X365mm complete with LED , driver and connection. Note :- To be connected with UPS DB
Supply and fixing surface & wall mounted LED tube light fittings 4 feet with 18/20 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply and fixing recess mounted LED down light fittings round/square type with 15/16 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 16 W/Total system lumen not less than 1600 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply and fixing surface mounted LED wall bracket fittings with 12/13 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: (i) System Watts/lumens: - Max 13 W/Total system lumen not less than 1300 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply and fixing surface mounted LED mirror fittings with 9/10 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply and fixing surface mounted LED 2X20W, 4 feet tube light fittings with 2X20 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 2x20 W/Total system lumen not less than 2000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply and fixing surface mounted LED down light fittings round/square type with 18/20 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply and fixing recess mounted LED down light fittings square type (2feet X 2feet) with 40/42 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 42 W/Total system lumen not less than 2000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
M&L for LED twin globe aviation obstruction light, Make : Bajaj, Cat No - MLED-60/Binoy Opto Electric/Havells complete with all fixing arrangement comprising of aluminium housing and polycarbonate enclosure with 302 LED.
Supply and fixing recess mounted LED down light fittings with 70/72 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 72 W/Total system lumen not less than 7200 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply, fabrication and fixing of steel frame work in position for cable tray/Panels fabricated out of 10 mm die GI rods, ISA-40 MS angle iron, ISMC-50 channels, flats etc.complete with providing of Anchor fasteners and all necessary hardwares as required for fixing, including cutting, bending, welding, drilling, bolting etc. as per design as required and painted with one coat of primer and two coats of enamel paint of approved shade.
Supply and fixing of Perforated type 2mm thick Hot dip Galvanised G.I. cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. as required for fixing and including the cost of providing loop earthing with 2 nos. 25 mm x 6 mm GI earth strips complete as per specifications, as required and as below.
(a) 150 mm wide 40 mm depth.
(b) 300 mm wide 40 mm depth.
(c ) 600 mm wide 40 mm depth.
Supply and fix compact air insulated rising main with copper busbar 1000 Amps having, breaking capacity of 35 KA and IP 54 protection, suitable for 415V AC, 3 phase 4 wire & double earth,(3 Phase+ 100% Neutral+2X50% Integral Earth) with rated operational voltage up to of 1000V, AC. The item include cost of separators, flexible joints, tap off boxes, end feed units etc. The quantities of end feed units, tap off boxes is to be included in the Item rate with the following salient features: - (from ground floor to top floor in main RHQ building) (a) Bus Bar should be supported with rigid and shock proof construction with minimum every 250mm distance. (b) Bus Bar enclosure should head tight, and should not easily slide even in vertical run. (c) Automatic polarity must be maintained during installation. (d) Bus Bar should be installed in two section which can be electrically isolated during maintenance in installed condition without dismantling or removal of an section. (e) Standard: IEC 60439 (1&2) & IS 8623 (1&2) (f) Certification: CPRI (g) nsulation: Air insulated type. (h) Material: main bus bar and earth bus bar all are Copper. (i) Rating 1000A (j) Configuration: 3 Phase+ 100% Neutral+2X50% Integral Earth (k) Rated operational and insulation voltage up to: 1100V AC (l) Enclosure Material: 1.6mm GI/equivalent. (m) Surface coating on enclosure: Epoxy polyester powder coated. (n) Bus Bar insulator: Glass filled Noryl/Polyester (Class F) (o) Protection: IP 54 (p) Joints: Uniblock joint (q) Plug in Box: up to 400A Make : C&S/ABB/SIEMENS/L&T
Supply, commissioning and testing of LT Indoor panel (Prewired) made with CRCA sheet minimum 3.15mm thick suitable for 415 Volt, 50 Hz, the panel should hold Type Test certificate (CPRI) with switchgear complete with, dust and vermin proof, hinged double door front and back, switchgear and all busbar covered with sheet metal, handle on door, locking arrangement both front and back door, anti rust coating, suitable cable entry hole, necessary PCC platform below panel, danger plate, 04 nos legs for standing, all as per IEC60 439-1 with following accessories (for item No 12.32 to 12.50):-
(a) GROUND FLOOR PANEL INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-100A) Ammeter with ASS with 3 nos. 100/5A CT's BUS-BAR 1 Set of 160A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 2 Nos.63A(10kA) 4P MCB . 3 Nos.40A(10kA) 4P MCB . 3 Nos.25A(10kA) DP MCB .
(b) FIRST FLOOR PANEL INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 160A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 1 Nos.63A(10kA) 4P MCB . 6 Nos.40A(10kA) 4P MCB .
(c) SECOND FLOOR PANEL INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 6 Nos.40A(10kA) 4P MCB .
(d) THIRD FLOOR PANEL INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 160A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 6 Nos.40A(10kA) 4P MCB .
(e) FOURTH FLOOR PANEL INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 160A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 4 Nos. 40A (10kA) 4P MCB 1 Nos.63A(25kA) TPN MCCB .
(f) FIFTH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 3 Nos. 40A (10kA) 4P MCB
(g) SIXTH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 2 Nos. 63A (10kA) 4P MCB 1 No. 40A (10kA) 4P MCB
(h) SEVENTH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 3 Nos. 40A (10kA) 4P MCB
(j) EIGHT FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 3 Nos. 40A (10kA) 4P MCB
(k) NINTH FLOOR PANEL INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 160A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 1 No. 63A (10kA) 4P MCB 2 Nos. 40A (10kA) MCB
(l) TENTH FLOOR PANEL INCOMER 1No. 200A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 300A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 2 Nos. 40A (10kA) MCB 1 No. 63A (10kA) 4P MCB 1 No. 160A (25kA) TPN MCCB.
(m) ELEVENTH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 3 Nos. 40A (10kA) 4P MCB
(n) TWELEVETH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 3 Nos. 40A (10kA) 4P MCB
(o) THIRTEENTH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 2 Nos. 40A (10kA) 4p MCB 1 No. 63A (10kA) 4P MCB
(p) FOURTEENTH FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 2 Nos. 40A (10kA) 4P MCB, 1 No. 63A (10kA) 4P MCB
(q) FIFTEEN FLOOR PANEL INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 1 No. 40A (10kA) 4p MCB, 1 No. 63A (10kA) 4P MCB
(r) LIFT PANEL 1 INCOMER 1No. 63A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 Nos. 2A SP MCB 1 nO (0-63A) Ammeter with ASS with 3 Nos 60/5A CT's BUS-BAR 1 Set of 100A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 1 No. 40A (10kA) FP MCB 2 Nos. 40A (25kA) FP MCB
(s) LIFT PANEL 2 INCOMER 1No. 100A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 Nos. 2A SP MCB 1 No (0-100A) Ammeter with ASS with 3 Nos 100/5A CT's BUS-BAR 1 Set of 160A TPN copper Bus Bar with colour coded PVC Sleeves OUTGOING 1 No. 40A (10kA) FP MCB 4 Nos. 40A (25kA) FP MCCB
(s) UPS PANEL INCOMER 1No. 160 amps 4P MCCB (16 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 Nos. 2A SP MCB 1 No (0-160A) Ammeter with ASS with 3 Nos 160/5A CT's BUS-BAR 1 Set of 200A 4P Copper Bus Bar with colour coded PVC Sleeves OUTGOING 20 Nos. 40A 4P MCCB (16KV)
Note (For item No 12.32 to 12.50): - All cable termination with the switchgear should be made with suitable size copper lugs and all cables should be minimum looped before entry in the panel for future requirements, and every incoming and outgoing cable/MCCB etc should be marked with marking plate accordingly they are connected with the buildings/loads, interconnection of switchgear should be made with suitable size busbar with proper colour code, all cable should be with cable gland suitable size in the entry point of the panel and required proper earthing of armour of the cable with panel, two Nos earthing point in each panel should be available for earthing.
M&L 50 sqmm 4 Core copper cable, PVC insulated flexible unarmoured, 1100V rating, suitable for 415V, AC, 3 phase 4 wire system from Bus Riser to Panel board (10th floor, and UPS panel)
M&L 35 sqmm 4 Core copper cable, PVC insulated flexible unarmoured, 1100V rating, suitable for 415V, AC, 3 phase 4 wire system from Bus Riser to Panel board (Ground floor, 1st floor, 2nd floor, 3rd floor, 4th floor, 9th floor and lift panel 2)
M&L 25 sqmm 4 Core copper cable, PVC insulated flexible unarmoured, 1100V rating, suitable for 415V, AC, 3 phase 4 wire system from Bus Riser to Panel board (5th floor, 6th floor, 7th floor, 8th floor, 11th floor, 12th floor,13th floor, 14th floor, 15th floor, and lift panel 1)
Supply, installation, testing & commissioning of Earthing complete with Copper earth plate electrode 60×60cm.× 3.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead as required by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point all as specified or indicated including testing on completion. (these earth pit will be connected to 2 Nos earth Bus riser inside the Bus riser system) including necessary excavation of earth work, provn of PCC pit of cement concrete (1:3:6) type C1 with 50mm thick pre cast RCC (1:2:4) type B1 cover slab (Re inforced with 8mm dia TMT bar @ 10cm c/c both way and suitable handle of 10mm dia round bar) including copper lugs and provn of charcoal/ coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore GI watering pipe (light grade), wire mesh, earth lead protection pipe 40mm bore (GI medium grade) etc. complete in all respect, disposal of surplus spoil at a distance not exc 50mtr and testing on completion all as specified and as directed (for transformer and panel).
Supply and installing control cable, PVC insulated 1100 V grade complete for the followings:-
(a) 2.5 Sqmm 4 core control cable
(b) 2.5 Sqmm 12 Core
All as per item No 12.01 above but with metal conduit (ERW) for flame proof wiring.
Supply and fixing flame proof rotary switch CMRI cerified suitable for 250V, 50Hz, AC, single phase, 6A current rating. Make : Sudhir switchgear, model-RI/A/146/Equivalent make of Baliga/Flexpro.
Supply and fix surface & wall mounted LED batten 2 feets with 1x10 w indoor decorative luminaries with and including Electronic driver and 1 x10 Watt LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 2000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate/glass cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 100 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 and third part NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
S&F Fluorescent tube light fitting, 1x36W flame proof CMRI certified type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. and all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete
SCH 'A PART IV (A) LIGHTENING PROTECTION Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead as required by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32 x 6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including taking down old one eathing complete all as specified and directed. Schedule 'A' Part-IV(A)-10 Nos and Sch 'A' Part-VII(A) - 04 Nos)
SCH 'A PART V (A) HOT WATER SUPPLY Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Supply, Install, Testing and Commissioning of storage water heater/Geyser 25 litres with all standard accessories complete with 2 Nos. inlet and outlet pipes for hot and cold water as standard fittings and complying the following specifications: - (i) Type: - Vertical (ii) Capacity of inner tank: - 25 litres (iii) Colour: - White (iv) Temperature sensitive LED indicators (v) Feather touch digital temperature control (vi) Shock proof 3 pin plug (vii) Up to 8 bar pressure resistant inner tank (viii) Multifunctional safety valv (ix) IPX4 technology to protect electrical parts from water splash (x) Earth leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shock (xi) Built in Thermostat (xii) Built in thermal cut-off (xiii) Tank: - Made with ultra thick super cold rolled steel plates dry powder coating finish and energy saving high density PUF insulation (xiv) Heating element: - Glass coated heating element with resistant to oxidation and carbonation at high temperature of 2000W capacity. (xv) Heave duty magnesium anode rod with steel core to protect enamelled tank from rust and corrosion (xvi) 230V, single phase, 50 Hz Ac power supply operated Make : - Havells/Crompton/Bajaj/ Racold/
Supplying, erecting, testing and commissioning of Solar Water Heating System with heat exchanger for cold & warm regions respectively with Solar flat plate collector conforming to IS: 12933 (part 1) with amdt.no.1 and IS: 12933 (Part 2)/2003 suitable for inlet water with chlorine and fluorine content up to 100 ppm and meeting specifications as under and comprising of followings:- (i) Supply and fixing Rotational Moulded Polyethylene water Storage Tank(Cylindrical Vertical with closed lockable top with lid and locking arrangements) hoisted and fixed in position all as specified in SSR Part-1 of capacity 250 Litres complete for storage of cold water feeding to Solar Water Heater, including 3 Meter Staging made out of MS Angle iron 50X50X6 mm all as specified and directed at site by Engineer-in-Charge- 1 No. (ii) Material : 1 Solar water heating system: Comprising of solar flat plate collector, collectors stand assembly, stainless steel insulated hot water storage tank with heat exchanger and various other components. Solar flat plate collector component shall have: • Solar flat plate collector cover plate made of toughened glass • Sheet for absorber made of copper • Absorber made of copper sheet and copper tube.
(iii) Solar Flat Plate Collector: Solar flat plate collector shall conforming to IS: 12933 (Part 1) with amdt.no.1 and IS: 12933 (Part 2)/2003 and various components shall be as under: Cover plate: Cover plate shall be toughened glass and thickness of 4.0 mm (min.) conforming to section-1 of IS: 12933(Part-2)/2003. The solar transmittance of the cover plate shall be minimum 82 percent at near normal incidence. Collector Box: Collector box shall be made of Aluminium sections only. Type, grade, size, workmanship and finish of the material used shall be as per section-2 of IS: 12933(pt2/2003. The minimum thickness of Aluminium shall be as under: (a) Channel section for sides 1.6 mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm. (d) Sheet for entire body 1.0 m (e) The number of flat plate collectors shall be consummate with required capacity of 200 Litres per day (iv) Absorber (a) Sheet for absorber : Sheet for absorber shall be made of copper only. Type, grade, size, workmanship and finis of the material used shall be as per sectiob-3 of IS: 12933 (pt2)/2003. A sample piece of the absorber for having minimum area of 400 square cm. shall be heated in an oven at temperature of 175 degree C for 2 hours. After heating, the sample shall be taken out from the oven and cooled at room temperature. The cooled sample shall be inspected visually for damages, if any. There shall not be any appearance of blistering/rupture/peeling off of the coated/painted surface and of weakening of the bonding between absorber sheet and risers/headers
(v) Collector box insulation: Insulation shall be provided at back and sides. This shall be derived after determining thermal conductivity (K) value at 100º C mean temperature in accordance with IS:3346.Collector box insulation shall conform to sec.4 of IS:12933(Part-2)/2003 (vi) Gaskets and Grommets: Gaskets and Grommets shall conform to sec.5 of IS: 12933 (Part-2)/2003. (vii) Insulated hot water storage tank: The thickness of the water storage tank shall be uniform. Material: Insulated hot water storage tank shall be non-pressure type and made of stainless steel grade (X04Cr19Ni9 or X07Cr18Ni9 of IS: 1570(part 5) /1985), TIG welded. Insulation: Solar water heating system (SWHS) up to and including 500 LPD shall be insulated with 40mm thermal grade PUF insulation of 32 Kg/ meter cube or higher density.PUF insulation could be pre extruded type fitted with FRP exterior cladding or alternatively injection moulded in a twin walled steel tank and PPE end cap. Other systems shall be insulated with 100 mm thick Rock wool of 48Kg/m3 density with 22swg Aluminium cladding. Systems up to 500 LPD may also alternatively be installed with 100 mm thick Rock wool of same specifications with aluminium or GI powder coated cladding. Tank stand: Tank stand assembly shall be made of MS angle of size (min) 40x40x4 mm duly pre-treated and stove enamelled with black Colour paint. Alternatively tubular structure with Powder coating could also be provided.
(viii) Additional tank of 200Ltr capacity at the outlet for Hot water supply with not less than 3KW electrical backup. (IX) Heat Exchanger: Heat Exchanger shall be cage type and made of copper/stainless steel tubes of grade X04Cr19Ni9 or X07Cr18Ni9 of IS: 1570(part 5)/1985 .Heat exchangers shall have a minimum of 0.24 sq. meters heat transfer area per 100 LPD capacities. (X) System inter connecting piping: ISI marked G.I. pipes, medium class of IS: 1239 duly insulated with 50mm thick rock wool of 48 Kg/m3 density and 26swg Al cladding. EPDM hose pipes can also be used for systems up to and including 500LPD. (XI) Collector stand: Collector stand assembly shall be made of MS angle of size 40x40x4 mm duly pre-treated and stove enamelled with black Colour paint. Alternatively tubular structure with Powder coating could also be provided. (XII) Make up water tank: The capacity of make up tank shall be up to 500 LPD. (XIII) Electrical heaters: Electrical heater shall be ISI marked. Electrical heater backup shall be two nos. each of rating 3 KW for 500 LPD.
(XIV)Temperature Gauge: Dial type, duly calibrated and suitable for temperature range from 0 degree C to 120 degree C and shall be provided for capacity above 500 LPD. (XV) Valves: 3 valves, one for inlet, outlet, and make up tank each. MAKE :-TATA BP SOLAR/ M/S SUPREME SOLAR SYSTEM OR EQUIVALLENT Notes : The Contractor shall submit schematic arrangements of all components of SWH and get it approved from Garrison Engineer. The exact location of SWH on roof top of the Building shall be decided by the Garrison Engineer.
Supplying, erecting, testing and commissioning of Solar Water Heating System with heat exchanger for cold & warm regions respectively with Solar flat plate collector conforming to IS: 12933 (part 1) with amdt.no.1 and IS: 12933 (Part 2)/2003 suitable for inlet water with chlorine and fluorine content up to 100 ppm and meeting specifications as under and comprising of followings:- (i) Supply and fixing Rotational Moulded Polyethylene water Storage Tank(Cylindrical Vertical with closed lockable top with lid and locking arrangements) hoisted and fixed in position all as specified in SSR Part-1 of capacity 500 Litres complete for storage of cold water feeding to Solar Water Heater, including 3 Meter Staging made out of MS Angle iron 50X50X6 mm all as specified and directed at site by Engineer-in-Charge- 1 No. (ii) Material :1 Solar water heating system: Comprising of solar flat plate collector, collectors stand assembly, stainless steel insulated hot water storage tank with heat exchanger and various other components. Solar flat plate collector component shall have: • Solar flat plate collector cover plate made of toughened glass • Sheet for absorber made of copper • Absorber made of copper sheet and copper tube.
(iii) Solar Flat Plate Collector: Solar flat plate collector shall conforming to IS: 12933 (Part 1) with amdt.no.1 and IS: 12933 (Part 2)/2003 and various components shall be as under: Cover plate: Cover plate shall be toughened glass and thickness of 4.0 mm (min.) conforming to section-1 of IS: 12933(Part-2)/2003. The solar transmittance of the cover plate shall be minimum 82 percent at near normal incidence. Collector Box: Collector box shall be made of Aluminium sections only. Type, grade, size, workmanship and finish of the material used shall be as per section-2 of IS: 12933(pt2/2003. The minimum thickness of Aluminium shall be as under: (a) Channel section for sides 1.6 mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm. (d) Sheet for entire body 1.0 m (iv) Absorber Absorber shall consist of riser, header, and sheet for absorber. The Diameter of header shall be 25.4 +/-0.5mm and thickness 0.71mm. The Diameter of riser shall be 12.7 +/- 0.5mm and thickness 0.56mm and made of copper only. The distance between the risers from centre to centre shall be 120mm. Type grade, size, workmanship and finish of the material used shall be as per section-3 of IS:12933 (Part 2)/2003. Riser and header assembly designed for working pressure up to 24.5 K Pa (2.5 kg/cm2 shall be tested for leakage at a minimum hydraulic pressure of 490 K Pa (5 kg/cm2). (a) Sheet for absorber: Sheet for absorber shall be made of copper only. Type, grade, size, workmanship and finis of the material used shall be as per sectiob-3 of IS: 12933 (pt2)/2003. A sample piece of the absorber for having minimum area of 400 square cm. shall be heated in an oven at temperature of 175 degree C for 2 hours. After heating, the sample shall be taken out from the oven and cooled at room temperature. The cooled sample shall be inspected visually for damages, if any. There shall not be any appearance of blistering/rupture/peeling off of the coated/painted surface and of weakening of the bonding between absorber sheet and risers/headers
(v) Collector box insulation: Insulation shall be provided at back and sides. This shall be derived after determining thermal conductivity (K) value at 100º C mean temperature in accordance with IS:3346.Collector box insulation shall conform to sec.4 of IS:12933(Part-2)/2003 (vi) Gaskets and Grommets: Gaskets and Grommets shall conform to sec.5 of IS: 12933 (Part-2)/2003. (vii) Insulated hot water storage tank: The thickness of the water storage tank shall be uniform. Material: Insulated hot water storage tank shall be non-pressure type and made of stainless steel grade (X04Cr19Ni9 or X07Cr18Ni9 of IS: 1570(part 5) /1985), TIG welded. Insulation: Solar water heating system (SWHS) up to and including 500 LPD shall be insulated with 40mm thermal grade PUF insulation of 32 Kg/ meter cube or higher density.PUF insulation could be pre extruded type fitted with FRP exterior cladding or alternatively injection moulded in a twin walled steel tank and PPE end cap. Other systems shall be insulated with 100 mm thick Rock wool of 48Kg/m3 density with 22swg Aluminium cladding. Systems up to 500 LPD may also alternatively be installed with 100 mm thick Rock wool of same specifications with aluminium or GI powder coated cladding. Tank stand: Tank stand assembly shall be made of MS angle of size (min) 40x40x4 mm duly pre-treated and stove enamelled with black Colour paint. Alternatively tubular structure with Powder coating could also be provided. (viii) Additional tank of 300Ltr capacity at the outlet for Hot water supply with not less than 4KW electrical backup.
(IX) Heat Exchanger: Heat Exchanger shall be cage type and made of copper/stainless steel tubes of grade X04Cr19Ni9 or X07Cr18Ni9 of IS: 1570(part 5)/1985 .Heat exchangers shall have a minimum of 0.24 sq. meters heat transfer area per 100 LPD capacities. (X) System inter connecting piping: ISI marked G.I. pipes, medium class of IS: 1239 duly insulated with 50mm thick rock wool of 48 Kg/m3 density and 26swg Al cladding. EPDM hose pipes can also be used for systems up to and including 500LPD. (XI) Collector stand: Collector stand assembly shall be made of MS angle of size 40x40x4 mm duly pre-treated and stove enamelled with black Colour paint. Alternatively tubular structure with Powder coating could also be provided. (XII) Make up water tank: The capacity of make up tank shall be up to 500 LPD. (XIII) Electrical heaters: Electrical heater shall be ISI marked. Electrical heater backup shall be two nos. each of rating 3 KW for 500 LPD.
(XIV) Temperature Gauge: Dial type, duly calibrated and suitable for temperature range from 0 degree C to 120 degree C and shall be provided for capacity above 500 LPD. (XV) Valves: 3 valves, one for inlet, outlet, and make up tank each. MAKE :-TATA BP SOLAR/ M/S SUPREME SOLAR SYSTEM OR EQUIVALLENT Note : The Contractor shall submit schematic arrangements of all components of Solar Water Heater and get it approved from Garrison Engineer. The exact location of Solar Water Heater on roof top of the Building shall be decided by the Garrison Engineer.
SCH 'A PART VII (A) EXTERNAL WATER SUPPLY Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Supply and laying of ductile iron pipe K9 with spigot and socket ends, centrifugal cast, laid in trenches, of 100 mm(4") dia with all pipe accessories complete all as specified and direted.
Supply and laying of ductile iron pipe K9 with spigot and socket ends, centrifugal cast, laid in trenches, of 150 mm(6") dia with all pipe accessories complete all as specified and direted.
Material and Labour for construction of brick masonary pit chamber of internal size 600 x 600 X 600 mm with locable MS cover fabricated with angle iron frame of size 20 mm x 20 mm x 6 mm thick, with Mild Steel plate cover 6mm thick, painted with two coat of synthetic enamel paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work. Chamber foundation constructed with 80 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate over 100 mm thick hardcore using broken bricks aggregate in foundation and finished in cement mortar 1:6 and 15 mm thick cement plaster in cement mortar 1:4 in internal surface of wall and outside upto 150 mm deep upto ground level complete all specified and directed by Engineer-in-Charge.
Supply, installation, testing and commisioning of Horizontal Centrifugal Pumping set (One Working and One Standby) as per DIN 24256 and ISO 2588, back pull out type, suitable for operation on 2850/2900 RPM, comprising of , centrifugal pump capable of delivering 60 Cubic meter per hour at 80 Meter Head, 2850/2900 RPM directly coupled with TEFC squireel cage induction motor 3 Phase, 415 Volts, 50 Hz AC supply IP 55 Protection, of HP/Wattage sutable to drive the pump, suitable for operation at up to 50 degree centigrade, Class "F" insulation, with temperature rise limited to Class "B"confirming to IS: 325, complete pump and motor assembled with base plate , coupling, coupling guard and foundation as per OEM's specifications cpmplete with suction pipe in suitable size and specifications as per OEM recommendations upto 3 meters in lenght, header and foot valve etc . Casing shall have axial suction and top centre line delivery. Impellers shall be of enclosed type. Shaft shall be supported with antifriction bearing, grease lubricated.
Providing and fixing On line chlorinator, chemical dozing system consisting of 2 nos. electronic dosing pumps (1W+1S) of approved make with all accessories, suitable to doze chemical solution upto 1 ppm doze (of Sodium Hypo-chloride solution) to a filtered water flow of 60,000 lph. against a pressure of 1.5 kg/cm2 complete with FRP moulded solution holding tank of min. 200 litre with all standard accessories & structural arrangement including suitable foundation bolts & other accessories etc.complete as required and as specified.
SCH 'A PART VIII (A) EXTERNAL ELECTRIC SUPPLY Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
M&L for Drop Out (DO) fuse assembly for 11 KV, 3 Phase system, 15A dropout fuse with the following specifications: - (a) Out door, Drop Out expulsion type Shall conform to IS:9385 (part I&II) following the latter amendments (b) Rated Voltage - 12 KV (c ) Single vent having front connected fuse carrier suitable for angle mounting. (d) All ferrous parts shall be hot deep galvanised. (e) The fuse carrier assembly shall be made with bronze casting opening eye (pull ring) type suitable for operation with Hook stick from the ground level to pull out or close the fuse carrier by manual operation (f) The fuse base shall be bird proof with single unit with two Nos. porcelain insulators with a creep edge distance (to earth) not less than 320mm from the 11 KV line. The porcelain insulators, the beam strength shall not be less than 1000 KG (i.e. mechanical falling load).
(g) The fuse tube shall be made of fibre glass coated with ultraviolet inhibitor on the outer surface and having arc quenching bone fibre liner inside. The tube shall have bursting strength to sustain high pressure of the gases during fault interruption. The inside diameter of the fuse tube shall be 17.5mm. The solid cap of the fuse carrier shall clamp the button head of the fuse link, closing the top end of the fuse tube and allowing only the downward venting during fault interruption. (h) The fuse and insulators assemblies shall be provided with suitable arrangement for mounting on 75X40mm or 100X50mm channel cross arm in such a way that the centre line of the fuse base is at an angle of 15° to 20° from the vertical and shall provide the necessary clearance from the supports. (j) The terminal connection of the cut-out shall be provided with two aluminium alloy connectors conforming to IS 617-1975 and amendments.
Design, fabrication, assembly, wiring, supply, installation and testing and commissioning of front operated dead front cubicle type compartmentalised LT Indoor panel board , rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hz system, fabricated from not less than 3.15 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, panel should hold Type Test certificate (CPRI) with switchgear assemblies as per IEC60 439-1 with following accessories :-
(a) Air Circuit breaker (ACB) 1200/1250A, 415V AC, 50 Hz, 50 KA, 4 pole with microprocessor release, manual draw out type, with ground fault protection, function check facility, current and time setting, monitoring and measuring actual current, close and precise protection, no external power supply, LED indicators etc -02 Nos one for DG set incoming and one for Main supply from transformer (i) Standard: IS/IEC 60947-2 (ii) Rated operating Voltage: 690V AC (iii) Rated insulation voltage: 1000V AC (iv) Rated Impulse voltage: 12KV (v) Utilization Category: B (vi) Rated frequency: 50/60 Hz (vii) Operating altitude: 2000M (viii) Humidity: 0-90% (ix) Ampere rating: 1200/1250 A (x) Pole: 4 pole (xi) Breaking capacity: 50 KA (xii) Fixed Type (xiii) Manual Draw out type and manual operation (b) 01 No of Automatic Transfer Switch (ATS), with necessary contactor, protection and interlocking arrangements suitable for 415V Ac, 50 Hz, 1200/1250A complete to be connected with the above 02 Nos ACBs and common output to be connected to primary Bus Bar.
BUS BAR: - 1600 A, 04 Nos (primary bus bar) and 400A, 04 Nos (secondary bus bar) aluminium Bus Bar with suitable length, suitable for 415V, AC system complete with necessary chromium plated steel nut bolts, washers, mounting insulators, necessary holes for nut bolts laminated with colour code. Outgoing: - (a) Air Circuit Breaker (ACB) as described above 1200/1250A-01No for main supply of RHQ building to be connected to primary Bus Bar Note: - Housing for the ACB for main out going supply of the RHQ building needs to be spacious because 04 Nos 1000 sqmm single core cable will be connecter with the out going terminal of the ACB, if extension of leads required it is also included in the item rate (b) 01 No Multi function meter for showing necessary electrical parameters (i.e. Voltage, Current, PF, KW, KWH, KVA, KVAR, Frequency Etc) with necessary CTs and PT. (c ) 02 Nos 63A, 4 pole, 415V Ac 50 Hz, 16 KA MCCB with thermal and over current protection are to be connected with the secondary bus bar one for Garage and one as spare (d) 02 Nos 63A, 4 pole, 415V Ac 50 Hz, 16 KA MCCB with thermal and over current protection are to be connected with the primary bus bar one for water supply panel and one spare
(e) 05 Nos 32A, 4 pole, 415V Ac 50 Hz, 16 KA MCCB with thermal and over current protection are to be connected with the secondary bus bar for guard room, sub stn supply, storage Accn, parade cum enrolling shed and one spare (f) 01 No 320A, 4 pole, 415V Ac 50 Hz, 35/36KA MCCB with thermal and over current protection are to be connected with the primary bus bar for fire fighting panel (g) Automatic Power Factor Correction capacitor bank with separate chamber (APFC) for 433V, 50 Hz AC system connected Parallel with primary Bus Bar (1600A bus bar), with automatic operation, microprocessor based 300 KVAR (25KVARX12) complete with 400A, TPN, 415V, 50 Hz AC, 35/36KA MCCB with thermal and overload protection (h) 01 No Automatic street light control unit complete with all accessories like MCCB, Contactor, timer etc of 12 KW capacity for controlling street light to be connected with primary bus bar. (j) All internal connection of the panel should be made with suitable size/rating aluminium strips. (k) Cable glands with suitable size needs to be provided for each cable (l) 02 Nos Earthing point for earthing strip connection. (m) Panel will be floor mounted without legs, hence base whole structure of the panel should be supported with high strength C channel. (n) Two sets of LED indicator lamp (RYB) for DG set and main supply. (o) Marking/name plate for all individual incoming and out going connection. Note: - The DG set supply and Main supply from Transformer will be connected to two separate ACB then ACB to Automatic Transfer Switch (ATS) then from ATS common out put to Primary Bus Bar (i.e.1600A) and one separate connection main supply ACB to be connected to secondary Bus Bar (i.e.400A) (i.e. the secondary bus bar is not the standby bus bar/not to be connected with DG set) (details drawing of the panel board needs to submit to GE for prior approval)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 1000 sq mm single core for main building supply and transformer to main LT distribution panel incoming ACB
Supplying and making end termination with aluminium lugs for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as follows :-
(a) 1000 sqmm.
(b) 70 sqmm.
(c ) 16 sqmm.
M & L earthing complete with Copper electrode 600x600x3.15 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate not less than 1.50 metre below normal ground level connected to Copper strip 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm Gl tubing light grade and necessary fitting for protection of Gl strip including laying of charcoal, dust and common salt PPC (1:2:3) type Cl using 20graded stone aggregate earth pit with 40x40x6mm MS angle iron frame RCC cover 40mm thick (1:2:4) type B20 using 12.5mm graded stone aggregate reinforced with 8mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6:) internally and up to 150mm below ground level externally. PGL funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed.
Supply and Fixing on walls with insulated saddles Copper Strip 50 X 6 mm for grid earthing of all Electrical Equipments (Note; Earth Grid shall be created on all three walls of Sub Station Building by 2 Nos. Of Copper strips 50X6mm and 4 No copper earthings. All earth able points of Transformer, DG sets, LT Panel, Pumps etc shall be connected to Earth Grid)
M&L for earthing complete with galvanized steel plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.50 m below ground level connected to Galvanized Iron wire 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including excavation and earth work and disposal of surplus soil including 15 mm GI tubing medium grade and necessary fitting for protection of GI wire including laying of charcoal dust and common salt PCC (1:2:3) type C-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia, plastering 15mm thick CM (1:6) internally and up to 150mm below ground level externally, PGI funnel with 20mm dia GI pipe light grade for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009 ) and connected to earth test including testing complete all as specified and directed.
Supply and Fixing LED street light fittings on poles /walls and including necessary GI brackets made with 40 mm dia light grade GI pipe with necessary clamps and nuts bolts suitably bended and up to 1.40 M length all as conforming to the following parameters: (i) System watt/Lumens: - Max-36 watts/total system lumen not less than 3600 lm (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt.
(ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 74 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design (xvi) (a). Bidder has to compulsorily submit the LM-79 and LM-80 and third party NABL accredited lab test report conforming of technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence. Make: - PHILIPS/HAVELLS/BAJAJ/WIPRO/GE LIGHTING
Supply, commissioning and testing of LT Panel board/feeder pillar outdoor type modular/combinable polycarbonate insulated which should be shock proof, safe, IP 54 according to IEC 60529 (the panel should be hold type test certificate in accordance with IEC 60439-1 (IS-8623), IEC-60439-3, the panel should have ASTA certification by CPRI and manufacturer routine test certificate should be provided), weather proof, rust proof, UV resistance, halogen free, silica free, corrosion proof, protection class-II, totally insulated, having internally embedded, polyurethane gasket with provision for cable entry through glands and/or grommets, flame retardant, self extinguishing with glow wire test at 960 degree C according to IEC-60695-2-11. Chemical resistance towards acid, and other chemicals, oils,, EMC compliant Bus Bar system, impact strength IK-08 in accordance with DIN EN 50102. (For pump house) The manufacturer shall submit a type test report in accordance with IEC-60-439-1
Supply and Fix Octagonal/Conical pole, 7M in length, single section, with Top dia 70mm, Bottom dia 130/135mm, thickness 3mm, base plate size (225X225X16)mm, with 4X20mm nut bolts, Hot deep galvanized 65micron, BSEN 10025-S355J0 or equivalent grade steel and base plate as per IS 2062, maximum wind speed resistance 169KM/Hr, single arm complete with Base PCC foundation of size 300x300x900mm duly bolts grouting 04 Nos with 40mm street light arm all as directed b the Eng-in-Charge. make: - NEZONE/WIPRO/SHAKTI/TATA
Supply and fix outdoor type cable junction box made of PVC complete with knockout for cable entry and 04 nos connectors, and 01 no of 5A SP MCB. Make Hensel, model No-KF2500B or equivalent make.
Supply, laying & testing PVC insulated, PVC sheathed electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade. (for street lights)
M&L for Double Wall Corrugated (DWC) pipe 100 mm with approx inner dia 98mm and approximate outer dia 116mm, complete with high flexibility and glass smooth design, with stiffness class SN2.
Supply & fixing GI strip 32mm x 6mm complete with saddles and fixing screws for fitting the strip.
M&L for Rubber Mat 1M X 2M X 20mm.
SCH 'A PART XI DG SET Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Supply, erecting, testing and commissioning of silent (Sound proof enclosure) type Diesel Engine Driven Generating Set capable of delivering 600 KVA, (480 KW at 0.8 Power Factor) Water&coolant cooled, 415 Volts (AC three phase, 4 wire system of supply) 50 HZ 1500 RPM complete with Automatic on Mains Failure (AMF) control panel. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel suitable for climatic conditions prevelanet at Kolkata with suitable derating factors as applicable and meeting specifications as elaborated here-in-after.
(i) ENGINE (Prine Mover) : Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, confirming to ISO3046/BS 5514, water and coolant cooled, naturally turbo charged, capable of giving adequate power to drive alternator capable of delivering 600 KVA at outdor atmospheric conditions at Kolkata, (Taking all derating factor into consideration), 24 Volt battery electric start complete with fly wheel all standard fittings / fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system with electronic governor and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc.) fuel tank and first fill of lub oil and other consumables etc and self starting system incl batteries etc complete. (ii) ALTERNATOR : Brushless AC alternator, 3 phase, 415 Volt, 4 wire, rated for output of 600 KVA,(480 KW at 0.8 Power Factor) 1500 RPM, IP 23 Protection class enclosure, insulation class "H", saliet pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
(iii) BASE PLATE : Made out of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE : Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 dB (A) at a distance of 1 M at 75% load under field condition 70 dB at 3 M from Gen set when DG set is working at full load along with testing conformance, lebeling certification etc as laid down in GSM No 371 (E) dt 17 May 2002 and amendements thereof. (v) Foundation/Plinth/Base : Shall be providedf as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the set and height of plinth shall not be less than 0.5M (vi) MISC : Tool kit, operation and maintenance catalogue, spare part list, overhaulling manuals, guarantee card etc shall be provided as per manufacturer standard parctices. (viii) Fully automatic AC operated additional battery charger of suitable capacity incl suitable size twin core copper wires fixed with copper lugs shall be provided from charger to batteries for charging of batteries without extra cost. Make of the complete DG set: - Kirloskar (KOEL GREEN) Model No- KG1-600WS, or equivalant model of Jakson-Cummins/Sudhir-Cummins/Greaves Power/Mahindra Powerol.
SPECIFICATIONS : (i) Voltage : 415 Volts, 3 Phase, 4 Wire (ii) Voltage : 415 Volts, 3 Phase, 4 Wire (iii) Power Factor : Not less than 0.8 Lagging (iv) Governing Class (as per ISO 8528 Part-V) : G3 (v)Noise Level : Less than 75 dBA (vi) Fuel Consumption : Not more than 135 liters per hour at 100% load, 100 Liters per hour at 75% load and 68 Liters per hour at 50% load. (vii) Fuel Tank Capacity : Not less than 990 Liters (viii) Height including silenser : Not exceeding 3500 mm. ENGINE (ix) Engine Rated output (Prime contineous as per ISO 8528-1) : Not less than 723 HO/532 KW (x) No of cylinders : 12 (xi) cubic capacity : Not less than 23.88 liters (xii) Bore X Stroke : 130 X 150 mm (xiii) Raterd speed : 1500 RPM (xiv) Aspiration : TA (xv) Lube oil change period : 500 Hours (xvi) Lube oil sump capacity : 50 liters (xvii) Coolant capacity : 135 Liters
ALTERNATOR (xviii) Insulation Class : Class H (xix) Ingress Protection : IP23 (xx) Alternator Efficiency : Not less than 95.5% at 100 % load and 95.8% at 75% load (0.8pf). (xxi) Permissible Voltage dip at full load 0.8pf lag < = 19% (xxii) Time permitted to build rated voltage at Rated RPM : < 5 Sec (xxiii) Short Circuit Ratio : 0.37 (xxiv) Short circuit withstand time : < 3 Sec (xxv) Overload withstand capacity : 10 % overload for one hour in 12 hour duration (xxvi) Canopy insulation shall confirm to UL-94 HF1 Class for flammability (xxvii) Controller shall be microprocessor based fully configured with garphical LCD display, monitoring features for all electrical parameters, lub oil parameters, Battery parameters and self diagnostics faeatures for all important parameters.
SCH 'A PART XII LIFT Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Design, supply, installation, testing and commissioning, of electrically operated, automatic passenger lift of capacity to carry 08 passengers (544 Kg) at a speed of 1.0 metre/sec, suitable to serve for G+14 floors(15 Floor, 15 Stops) with AC Variable Frequency Regenerative(Closed loop) control drive, equipped with low noise Gearless machine, installed in machine room on roof top complete with all standard accessories and control panel, Full collective Group operation (with Four lifts in one group i.e. 2X 8 Passenger and 2X 13 Passenger in separate shafts opening on same sides ) with or without attendant, centre opening doors with door drive automatic operation, stainless steel landing doors. Automatic Rescue Device (ARD), 3D infrared sensor in full height of door, built in announcing system with intercom (in machine room and near ground floor and in car), stainless steel car enclosure complete all as specified and directed with the following :-
(a) Controller Type : Micro Processor controlled Drive VR Ergative (Closed Loop) ACD3-MR (b) Drive : VF Regenerative (Closed Loop) (c )AC Power Supply : 400/415 Volts (3 Phase 4 wire system) (d) Operation : Full Collective Group Operation ( with Four lifts in one group i.e. 2 X 8 Passenger and 2X 13 Passenger in separate shafts opening on same sides) (e) Car Group : Four cars (f) Machine PM (Permanent Magnet) Gearless (Located above shaft in machine room) (g) Traction media : Polyurethane coated steel belts /Steel wire ropes. (h) Car Finish: Stainless steel # 4 (Hairline) for Rear Middle. Rear Corner, side, Front & False ceiling panels. Full size mirror to be provided at the rear side of car inside above hand rails. (j) False ceiling type : Stainless steel # 4 (Hairline) along with fitment of car lights LED light fittings. (k) Ventilation : Axial flow fan. (l) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. (m) Flooring : Aluminium Chequered Plate with vinyl flooring (n) Car Door / Land Doors Finish : Stainless steel # 4 (Hairline). (o) Car Dimensions (internal) (W x D x H - mm) : 1300 x 1100 x 2200 mm. (p) Car and Hoist way Door type : Central Opening Doors.
(q) Door Opening (WxH-mm) : (800x2000) mm. (r) Door operator : DC door operator. (s) Car operating panel : Square flush painted buttons in stainless steel # 4 (Hairline). (t) Car position indicator : Dot matrix (Red LED) scrolling display. (u) Hall fixtures : 16 segment display hall button. (v) Hall fixtures face plate : Pan type in Stainless steel # 4 (Hairline). (w) Hall button arrangement : Hall button with FPI. (x) Automatic Rescue Device with maintenance free batteries (ARD). (y) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (z) Intercom arrangement between ground floor machine room and car. (aa) One hour fire rating for all landing doors. (ab) Voice Synthesizer. Make : OTIS/KONE/SCHINDLER/MITSUBISHI
Design, supply, installation, testing and commissioning, electrically operated, automatic passenger lift of capacity to carry 13 passengers (884 Kg) at a speed of 1.0 metre/sec, suitable to serve for G+14 floors with AC Variable Frequency Regenerative(Closed loop) control drive, equipped with low noise Gearless machine, installed in machine room on roof top complete with all standard accessories and control panel, Full collective Group operation (with Four lifts in one group i.e. 2X 8 Passenger and 2X 13 Passenger in separate shafts, opening on same sides ) with or without attendant, centre opening doors with door drive automatic operation, stainless steel landing doors. Automatic Rescue Device (ARD), 3D infrared sensor in full height of door, built in announcing system with intercom (in machine room and near ground floor and in car), stainless steel car enclosure complete all as specified and directed with the following :-
(a) Controller Type : Micro Processor controlled Drive VR Regenerative (Closed Loop) ACD3-MR (b) Drive : VF Regenerative (Closed Loop) (c )AC Power Supply : 400/415 Volts (3 Phase 4 wire system) (d) Operation : Full Collective Group operation (with Four lifts in one group i.e. 2X 8 Passenger and 2X 13 Passenger in separate shafts, opening on same sides ) (e) Car Group : Four cars (f) Machine PM (Permanent Magnet) Gearless (Located above shaft in machine room) (g) Traction media : Polyurethane coated steel belts /Steel wire ropes. (h) Car Finish: Stainless steel # 4 (Hairline) for Rear Middle. Rear Corner, side, Front & False ceiling panels. Mirror : Full size mirror to be provided at the rear side of car inside above hand rails. (j) False ceiling type : Stainless steel # 4 (Hairline) along with fitment of car lights LED light fittings. (k) Ventilation : Axial flow fan. (l) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. (m) Flooring : Aluminium Chequered Plate with vinyl flooring (n) Car Door / Land Doors Finish : Stainless steel # 4 (Hairline).
(o) Car Dimensions (internal) (W x D x H - mm) : 1100 x 2000 x 2200 (p) Car and Hoist way Door type : Central Opening Doors. (q) Door Opening (WxH-mm) : 800 mm X 2000 mm (r ) Door operator : DC door operator. (s) Car operating panel : Square flush painted buttons in stainless steel # 4 (Hairline). (t) Car position indicator : Dot matrix (Red LED) scrolling display. (u) Hall fixtures : 16 segment display hall button. (v) Hall fixtures face plate : Stainless steel # 4 (Hairline). (w) Hall button arrangement : Hall button with FPI. (x) Automatic Rescue Device with maintenance free batteries (ARD). (y) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (z) Intercom arrangement between ground floor machine room and car. (aa) One hour fire rating for all landing doors. (ab) Voice Synthesizer. Make : OTIS/KONE/SCHINDLER/MITSUBISHI
Design, supply, installation, testing and commissioning, electrically operated, automatic passenger lift of capacity to carry 13 passengers (884 Kg) at a speed of 1.0 metre/sec, suitable to serve for G+14 floors with AC Variable Frequency Regenerative(Closed loop) control drive, equipped with low noise Gearless machine, installed in machine room on roof top complete with all standard accessories and control panel, Full collective operation (Duplex) with 1X 13 Passenger in separate shafts, opening on same sides,) with or without attendant, centre opening doors with door drive automatic operation, stainless steel landing doors. Automatic Rescue Device (ARD), 3D infrared sensor in full height of door, built in announcing system with intercom (in machine room and near ground floor and in car), stainless steel car enclosure complete all as specified and directed with the following :-
(a) Controller Type : Micro Processor controlled Drive VR Regenerative (Closed Loop) ACD3-MR (b) Drive : VF Regenerative (Closed Loop) (c )AC Power Supply : 400/415 Volts (3 Phase 4 wire system) (d) Operation : Full Collective Group ( duplex ) operatin with one in 13 passenger in separate shafts, opening in the same side. (e) Car Group : two cars (f) Machine PM (Permanent Magnet) Gearless (Located above shaft in machine room) (g) Traction media : Polyurethane coated steel belts /Steel wire ropes. (h) Car Finish: Stainless steel # 4 (Hairline) for Rear Middle. Rear Corner, side, Front & False ceiling panels. Full size mirror to be provided at the rear side of car inside aabove hand rails. (j) False ceiling type : Stainless steel # 4 (Hairline) along with fitment of car lights LED light fittings. (k) Ventilation : Axial flow fan. (l) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. (m) Flooring : Aluminium Chequered Plate with vinyl flooring (n) Car Door / Land Doors Finish : Stainless steel # 4 (Hairline).
(o) Car Dimensions (internal) (W x D x H - mm) : 1100 x 2000 x 2200 (p) Car and Hoist way Door type : Central Opening Doors. (q) Door Opening (WxH-mm) : 800 mm X 2000 mm (r ) Door operator : DC door operator. (s) Car operating panel : Square flush painted buttons in stainless steel # 4 (Hairline). (t) Car position indicator : Dot matrix (Red LED) scrolling display. (u) Hall fixtures : 16 segment display hall button. (v) Hall fixtures face plate : Stainless steel # 4 (Hairline). (w) Hall button arrangement : Hall button with FPI. (x) Automatic Rescue Device with maintenance free batteries (ARD). (y) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (z) Intercom arrangement between ground floor machine room and car. (aa) One hour fire rating for all landing doors. (ab) Voice Synthesizer. Make : OTIS/KONE/SCHINDLER/MITSUBISHI
Notes For Item No 18.01 to 18.09 above: (i) All lifts shall be obtained from one OEM only. The installation, testing and commissioning of lifts shall be got done from the same OEM (ii) Contractor needs to submit the certificate that lifts are installed by OEM or their accredited agencies. (iii) A safety certificate by safety division of OEM needs to be submitted after final commissioning of the lifts. (iv) Contractor shall note that the defects liability period for lift shall be one years from the certified date of completion on as certified by GE: During the said defects liability period, and all consumable items shall also be provided by contractor for running of the lift. (v) One Electrical Panel with adequate rated incomer MCCB and 6 No. adequate rated MCB/MCCB shall be provided in one of the lift Control room at Terrace level. This Panel shall be measured and paid for separately under different schedule of this Contract. All control cabling from this panel onward is deemed to be included in the unit rate quoted for lift. (vi) Lifts and other associated electrical items shall be earthed as per relevant IS Code/NBC-2016. Cost of the above provisions shall be deemed to be included in the rates quoted by contractor. One Bus truncking system with two independent earth strips are being provided in the building. Contractor may connect earth leads to earth strips in this Bus Bar. (vii) The lift shall be inspected and commissioned by the lift inspector and it shall be the responsibility of the contractor to get the lift inspected & commissioned without any extra cost to the government.
SCH 'A PART XIII TELEPHONE AND TV CONNECTION Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Supply, installation, testing & commissioning of plug-in type telephone socket outlet in existing G.I outlet box and cover plate complete as required in existing conduit. RJ-11
Supply, installation, testing & commissioning of plug-in type television socket outlet in existing G.I outlet box and cover plate as required in existing conduit.
Supply, installation, testing & commissioning of Cats 6 information outlets (Tolless) that should confirm or exceed component specifications TIA/EIA-568-C standards for physical & electrical specifications, should be fully unshielded type. Measurement of components & links, validated by independednt 3P Third pary testing & ETL, have highlighted its triple performance, All products are RoHS compliance. All products are UL approved. ISO 11801 ED 2.0, amendement 2, EN 50173-2.
Supply, installation, testing & commissioning of the following sizes of annealed tinned electrolytic copper conductor PVC insulated unshielded twisted 2 pair (0.61mm) telephone wires in existing conduit and making connection on both the ends.
Supply and drawing the following sizes of annealed tinned electrolytic copper conductor PVC insulated unshielded T.V. Co-axial cable RG-11 in existing conduit/shaft/riser
Supply, installation, testing and commissioning of 4 pair Category 6 LAN cable consisting of 23 AWG solid copper conductors in existing conduit.
SCH 'A PART XIV CENTRAL AIR CONDITIONING, COOLING APPLIANCES AND REFERIGERATION Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Supply , installation, testing and commissioning of Variable Refrigerant Volume / Flow Air-conditioning System (Heating & Cooling both) and air pressure system on turnkey basis and performance gurantee basis, comprising of sub-systems, measurable items and specifications as elaboarted here-in -after for Item No 20.02 to 20.37. The complete system is to be got executed on turnkey basis under the supervision of OEM of VRF System. The Performance gurantee is with respect to achiving the Indoor conditions, for ambient conditions prevelent at Kolkata, as Under: (a) Offices- Temperature-22 +/- 2 Degree Centigrate, Relative Humidity- < 55%, Waiting Areas-Temperature-25 +/- 2 Degree Centigrate, Relative Humidity- < 55%, .All Areas- Noise Level- As per National Building Code-2016 Norms.
Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll compressor controlled by individual inverter complete with indoor and outdoor units with individual wired and wireless/wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items :-
All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control, which should be refrigerant cool. Machines shall be suitable for working with BMS system. It is mandatory that each compressor shall have inverter technology separately i.e. outdoor units shall have all inverter based compressor. Following capacities of ODUs are at standard operating condition as defined above and Vendor to indicate COP at 100% load & at part loads i.e. 75% & 50% in the data sheets/ shop drawings :- Notes:- (i) Air conditioning system control panel needs to be inter connected with the fire alarm and dictation control panel with necessary control cable in such a way that in case of fire incidents air-conditioning system should be switched OFF. Necessary switch gear and logic panel is deemed to be included in the item rate. (ii) Air conditioning system to be installed by authorized Original Equipment Manufacturer (OEM) or accredited agencies. (iii) Contractor needs to be submitted the certificate that air conditioning systems are installed by OEM. (iv) After post installation shall be got tested from OEM before offering for departmental test. Makes:-Daikin/Mitsubishi/Hitachi/Toshiba/ Bluestar/Trane
High wall unit Supply, Assembly, Erection, Testing and Commissioning of High wall Units with fittings. Three speed motor, turbo fans of multi blade type, duly statically and dynamically balanced to give the required air flow, filter, coil section with DX coil, fresh air intake connector wherever required, outer cabinet, insulated drain pan, built-in high head fail-safe drain pump with safety cut-outs, drain water lift-up mechanism, air distribution panel & panel shall have removable return air core for cleaning air filter and maintaining motor etc including all accessories. Cable from unit to socket and headers etc. complete as required for the following capacity :-
VRV/VRF Cordless Remote Controller Supply, installation, testing & commissioning of wireless Remote controllers suitable for above indoor units to operate, monitor, ON/OFF, temperature setting, 3 step air flow changing etc. The remote controller shall be suitable for wall mounting with bracket.
REFRIGERANT & AC DRAIN PIPING Supply, installation, testing & commissioning Refrigerant 'Y'Joint required for distribution of refrigerant in copper piping etc. complete as per specifications.
Supplying & Installation of interconnecting following sizes of Refrigerant Copper Pipe work of following outer diameter, insulated with 19/13 mm thick closed cell electrometric nitrile rubber tubular insulation between Each set of indoor & outdoor units with 2 coats of Starbond 30-36 Super ,an Acrylic polymer to offset impact of UV rays .Alternatively Starbond30-36 Super to be used In conjunction with 7 mil woven fibre glass cloth to offset the impact of mechanical injury and scratch resistance for all pipes as per specification all piping inside the building shall be properly fixed/supported with suitable size of clamp/ M.S. hanger for the following :-
(a) 6.4 mm dia with 13mm thick nitrile rubber insulation
(b) 9.5 mm dia with 13mm thick nitrile rubber insulation
(c )12.7 mm dia with 13mm thick nitrile rubber insulation
(d) 15.9 mm dia with 13mm thick nitrile rubber insulation
(e) 19.1 mm dia with 13mm thick nitrile rubber insulation
(f) 22.2 mm dia with 19mm thick nitrile rubber insulation
(g) 28.6mm dia with 19mm thick nitrile rubber insulation
(h) 34.9 mm dia with 19mm thick nitrile rubber insulation
(j) 41.3 mm dia with 19mm thick nitrile rubber insulation
CONDENSATE DRAIN PIPING Supply installation, testing and fixing of Class’B’ PVC pipes ISI as per IS 4985-2000,SDR 11, drain piping complete with insulation fittings, supports as per specifications as follows :-
(a) 32 mm dia
(b) 25 mm dia
Providing & fixing control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable 25 mm dia heavy duty PVC conduits or wall chase or refrigerant piping between indoor units and outdoor units and indoor units and wired controllers.
(a) 40A MCCB for 5.0 HP
(b) 63A MCCB for 7.5 HP
(c ) 63A MCCB for 12.5 HP
Refrigerators/Deep Freezers Supply and fix refrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308-315 litres capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor, with minimum BEE 4 star rating and inbuilt voltage stabilization system complete . Make Godrej Model No. RT EON 311 SC or Equivalent of LG/Samsung/HITACHI
Supply and fix refrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 180-185 litres capacity, conforming to IS 1476 for direct cool, with power saver compressor, with minimum BEE 4 star rating inbuilt voltage stabilization system complete . Make Godrej / LG/Samsung/HITACHI
Supply and fix refrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 270-280 litres capacity, conforming to IS 1476 for direct cool, with power saver compressor, with minimum BEE 4 star rating inbuilt voltage stabilization system complete . Make Godrej / LG/Samsung/HITACHI
M&L for Deep Freezer 320 Litres, Hard Glass Top, single phase electric driven, 230V AC, 50 Hz, with minimum BEE 4 star rating inbuilt voltage stabilization system complete complete. Make VOLTAS Model 320 LSD or Equivalent of Blue Star, LG/Samsung/HITACHI
WATER COOLERS Supply, Installation, testing and commissioning of water cooler electric driven (single Phase) inbuilt voltage stabilization system complete having approximate storage capacity of 80 Liters and Nominal cooling capacity of 40 Liters per Hour, body made up of non-corrosive stainless steel material, complete comprising of water storage tank of approx 80 Liters capacity made of hygienic stainless steel having lockable lid with proper rubber sealing for protection against ingress of dust, dirt and insects, thermal insulation of water tank with PUF material, Energy Efficient hermetically sealed compressor working on Non-CFC, Non Toxic, Non-Inflammable, environment friendly refrigerant R-32 or R-22, with suction gas cooled. Equipped with Over-load protector, relay and other accessories, Condenser fan –noiseless propeller type, with thermostat for automatically control of temperature with 15 Amps 3 Pin Plug top, 3 core cable and earth terminal, inlet water connection with 15 mm flexible pipe having female nut on both ends with efficient float valve for control of water, water outlets with two push types cocks, drainage arrangement complete all as specified.
Supply, Installation, testing and commissioning of water cooler electric driven (single Phase) inbuilt voltage stabilization system complete having approximate storage capacity of 120 Liters and Nominal cooling capacity of 60 Liters per Hour, body made up of non-corrosive stainless steel material, complete comprising of water storage tank of approx 120 Liters capacity made of hygienic stainless steel having lockable lid with proper rubber sealing for protection against ingress of dust, dirt and insects, thermal insulation of water tank with PUF material, Energy Efficient hermetically sealed compressor working on Non-CFC, Non Toxic, Non-Inflammable, environment friendly refrigerant R-32 or R-22, with suction gas cooled. Equipped with Over-load protector, relay and other accessories, Condenser fan –noiseless propeller type, with thermostat for automatically control of temperature with 15 Amps 3 Pin Plug top, 3 core cable and earth terminal, inlet water connection with 15 mm flexible pipe having female nut on both ends with efficient float valve for control of water, water outlets with two push types cocks, drainage arrangement complete all as specified.
SCH 'A PART XV FIRE FIGHTING AND FIRE ALARM SYSTEM Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
FIRE ALRAM AND DETECTION SYSTEM NOTE : All items of work under this schedule from Item No 21.02 to 21.97 shall be executed in accordance with recommendations of Centre for Fire, Explosives & Enviornmenr Safety,(CFEES) New Delhi. These recommendations are available with Garrison Engineer. The contractor are advised to familiarize himself with the CFEES recommendations in addition to the enclosed drawings fot fire fighting. The complete fire alarm and detection system shall be got executed from any of the OEM (Notifier/Ravel/Edard) or their accredited agencies. The complete fire detection and alarm system and fire fighting system shall be got tested from "West Bengal Fire and Emergency Department". All charges fir getting the system tested shall be borne by the contractor. The unit rate quoted for item No 21.02 to 21.97 shall be deemed to be inclusive of this provision.
Supply, Installation, Testing and commissioning of ARM Cortex Microprocessor Based Intelligent Fire Alarm Panel UL listed 9th edition , 40 x 4 Characters LCD display, Maximum 4 number of loop cards with Class A Style 5,6 or 7 / Class B style 4 wiring, 254 devices per loop, Day / Night Mode Facility, USB 2.0 Interface for PC connectivity, RS 485 Communication facility for Network / Repeater, Programmable Auto Silence Facility, Programmable Trouble Reminder Facility, Programmable AC Loss Delay, Programmable Silence Inhibit, Two no’s of Programmable Inputs, Loop wise test facility, Battery low visual warning with audible tone, Three Programmable Form C relay for Fire, Fault and supervisory, Two nos. of Supervised Notification Appliance Circuits, Auto dialler / GSM Module, Ethernet Module, Printer Interface Module, Loop card : 4 Nos. Maximum, Number of Devices per loop : 254, Loop resistance : 40 (Max.), Loop capacitance : 0.6 μf (Max.), Loop Current : 300mA (Max.), One conventional zone Class B Style B/C operation, Normal Operating Voltage : 14 - 21 VDC, Alarm Current : 15 - 30mA Short Circuit Current : 45mA Maximum, Loop resistance : 100 Maximum, End-Of-Line Resistor : 4K7, 1/2watt, Standby Current : 7mA (2mA for Detectors) with battery backup of 30 minutes in alarm condition and 24 hours in Normal Condition 8 loop panel complete Make:- Notifier, Ravel, Edward
Supply, Installation, Testing and commissioning of Analogue Addressable Multi-criteria Detector, UL listed 9th edition, Dual LED’s for 360 visibility, Advanced detection and communication protocol, Regular 100mm base, Address setting by 8 digit DIP switch, Operating Voltage17 ~ 28V DC, Reset Voltage, less than 3V, Start-Up Current, 500 μA Alarm Current, 5 mA, Remote Output, 2mA maximum open collector, Thermal Rating : 59C,Rate of Raise of Temp : 11.1C / min, Humidity-0 - 95% RH, non-condensing, Smoke Sensitivity : (2.12 ± 0.61) % / ft, High : 1.1% ft, Middle : 1.4% ft, Low : 2.3% ft, Air Velocity : 0 - 4000 fpm,IP Rating : IP – 42 Make Notifier, Ravel, Edward
Supply, Installation, Testing and commissioning of Analogue Addressable Monitor Module UL-Listed (9th Edition), Modular Construction, Module Status by RED LED, Module Addressing by 8 way DIP switches, Low Standby Current, Available with suitable back boxes o Operating Voltage : 24 VDC Nominal, Alarm Current : 2.7 mA Max.(Latched), Standby Current : 0.7 mA, End of Line Resistor : 47K Ohms, Communication Line, Loop Impedance : 40 Ohms, IDC wiring Resistance : 100 Ohms Max, IDC Voltage : 8 V Max, Temperature Range : 0oC to 49oC / 32 - 120 F. Make Notifier, Ravel, Edward
Supply, Installation, Testing and commissioning of Addressable Manual Pull Station, UL listed 9th Edition, Type A Indoor Use, Resettable by an align key, shall painted by Die casting Housing, shall have a break Glass Rod, Shall have Single gang Mounting, Shall be RED in colour, Shall have corrosion free gold Contact with 10 A rating ,Shall be integrated with addressable panel thru Monitor Module (UL Listed) : Make Notifier, Ravel, Edward
Supply, Installation, Testing and commissioning of Sounder cum Strobe with addressable control Modules, UL Listed 9th Edition, Operates on 24VDC, 100db, Ceiling / Flush Wall Mount, Input Voltage : 24V DC (15-30V), Current : 100 mA @24V, Relative Humidity : 93 ± 2 @ 32 C, Operating Temperature : -10 to 50 C, Sound Level : 112 db +/- 5dB @ 30cm, Tone Type : Sweep Siren, Size : 126(W)*126(H)*55(D)mm Make Notifier, Ravel, Edward
Supply installation testing & commissioning of fireman master control panel with 8 zone location with alarm indication , phone jack and hand set. Shall we monitor for open short circuit failure, master to remote and remote master calling facilty. Operating voltage 220 V AC 50 Hz with inbuilt charger facilty. Make Notifier, Ravel, Edward
Supply, Installation, Testing & Commissioning of Fireman's Phone Jack with all mounting accessories, complete with MS Powder coated Junction Box for mounting on Surface, Cable Lugs at Ends and all required accessories for mounting at site complete as requried. Make Notifier, Ravel, Edward
Supply, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Handset. Complete as required as per technical specification. Make Notifier, Ravel, Edward
GRAPHIC CONTROL STATION Supply ,Installation and Commissioning of Graphic Software - to monitor & control the status of the FACP from the windows based system - with Visual & Sound alerts for the fire and fault conditions - with Three Level multi users access. Make Notifier, Ravel, Edward
Supply ,Installation and Commissioning of Configuration Software - GUI Based - Location Programming for each device - Monitor & Control the status of the FACP's from the PC. Make Notifier, Ravel, Edward
CPU comprising of Intel 1-5 processor, 4G RAM, 500GB hard disk, Intel mother board of 3000 MHZ, 19" LED monitor, Keyboard, Mouse, network adaptor , graphics card connected to fire alarm panel . The CPU shall be suitable to integrate no of FACPs located in various locations with software to display location of fire / activated device monitoring on the map of entire facility and windows 8 multitasking software with license. CPU shall be suitable to connect single mode optical fibre cable and along with require modules/convertors to the added for OFC cables required in complete.
Laser Jet Printer (A3 size) as per Specification
21" colour monitor flat screen LCD display with accessories as per specifications.
CONDUITS AND CABLES Supplying and drawing fire survival control cable through ERW steel conduit necessary size, with class-2 copper conducter twin twisted with ceramiflable silicon insulation alongwith drain wire, aluminium tape and Low Smoke Zero Halogen (LSZH) outer sheath as per BS-7629 part-I, outer should be Anti Rodent. Fire test in accordance with BS:6387 - 1994 CWZ.
(a) 2 x 1.5 sq. mm
(b) 4 x 1.5 sq. mm
Supplying and fixing of following sizes of Rigid steel conduit, welded of 25 mm size
PUBLIC ADDRESS SYSTEM Supply ,Installation, Testing and Commissioning of Ceiling Mountable ABS plastic grille with metal punched net Speaker , Flush mount 14cm dynamic cone speaker, Shall be Easy to install with spring catch mount, Shall have Connectors with screw for hooking up the wires tightly, Shall have 100V power taps, shall have Protective dust cover at rear, A circular template for marking a hole is accompanied with the speaker, Shall have Line Matching Transformer with the Tapping of 1.5,3 and 6 watts, shall be white in Colour, Shall give the Music Power of 10 watts with the impedance of 100V with 92 dB Maximum. Make Notifier, Ravel, Edward
Supply, Installation, Testing and Mounting of Wall mounted Horn speaker for announcement and paging. Shall be Made of Aluminium body, Shall be equipped with the Five tapping transformer to deliver 100V,2.5w,5w,7.5w,10w,12.5w,15w and 25 watts(max) output, Output shall be maximum of 106dB,Shall be grey In colour. Make Notifier, Ravel, Edward
Supply, Installation, Testing and Commissioning of Digital Signal Processing Based Voice Alarm Controller ,Shall have 4 inputs, Shall supports Paging Unit thru RS485,shall have Digital Amplifier inbuilt of 250 watts, Shall have 8 zones inbuilt, each zones shall supports maximum of 250 watts, Zones shall be expandable in the multiples of 8 up to maximum of 64 zones, Shall Support Remote Paging Unit ,shall be integrated with Fire Alarm system, Shall have Emergency Inputs ,Shall supports 12 nos of Built in Programmable Digital Voice Alert message ,Shall have 160 characters LCD display, Shall have USB connectivity, Shall have PC based Router Configuration, Shall have 3 levels of password protection, Shall have Event Log facility, Shall have Overriding Facility for Emergency Condition, Shall have ALL CALL facility, Shall have Zone paging facility, Shall have inbuilt MIC ,shall be 19" Rack Mountable. Shall works on 230 VAC ,Shall have volume control features for all the zones, Shall Supports maximum of 7 slaves with each of 8 zones. Make Notifier, Ravel, Edward
Supply, Installation, Testing and Commissioning of Digital Amplifier of 250watts output, Class D amplifier, Low Heat dissipation, Shall be integrated with Slave console ,Shall have Power ON LED indiactions, Shall be 19" RACK Mountable. Make Notifier, Ravel, Edward
Supply installation, Testing & Commissioning of Professional CD/DVD player with USB flash port & 19" Rack mount arrangement.
Supply installation, Testing & Commissioning of Volume Controller for Office and Cabins
Supply, Installation, Testing and Commissioning of Suitable Rack for the required height of 19 " width with Exhaust fans and Power Sockets and Door with Lock arrangements, etc.,
Supply and drawing twin twisted 32/0.2mm PVC insulated copper conductor speaker wire in existing conduit including earth wire complete as required (for speakers). This includes wiring for the amplifier as well.
Supplying and drawing 2 Nos of 1.5 Sq mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of Rigid steel conduit, welded of size 25 mm
Supply, installation, testing and commissioning of remote responce indicator unit
FIRE FIGHTING SYSTEM NOTE : All items of work under this schedule shall be executed in accordance with recommendations of Centre for Fire, Explosives & Enviornmenr Safety,(CFEES) New Delhi given in Particular Specifications.
Supply, installation, testing and commissioning of fire hydrant landing valve type B (double head outlet) of 63 mm dia conforming to IS : 5290 with twin 63 mm female coupling instanataneous outlet ISI marked IS:5290 including cost of MS flanges washer, cutting, welding etc at all height and all as directed by Engineer-in-Charge. Make: Newage/Omex/Supermex/ Getech.
Supply and fix hose box indoor type flush mounting or least protruding type of suitable size for keeping 2 Nos hose pipe of length 15 meter each, with 1 No. fire hydrant landing valve type B (double head outlet) of 63 mm dia branch pipe.nozzle, coupling etc made of MS sheet of Thickness not less than 1.6 mm having central opening glazed door (4 mm thick clear glass) including necessary locking arrangement with handle for housing two Nos, 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (one coat of primer and two coats of fire red colour). The cabinet shall be mounted on MS Angle iron frame as directed by engineer-in-charge. The words "FIRE" to be painted on the box complete all as specified and directed. Make: Getech/Minimax/Newage.
Supply installation testing and commissioning of First-aid fire hose reel wall mounting swinging type complete with drum, bracket, 25 mm dia. Ball (stop) valve and 20 mm dia. X 36 m long polymer 'light duty' high pressure hose reel tubing as per IS:444 with gun-metal triple purpose nozzle . The hose reel shall strictly confirm to IS: 884 : 1985.
Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness
Supply and fix 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS : 903
Supply and fix 63 mm dia 15 meter long hose non percolating type conforming to IS 636 complete with male and female coupling conforming to IS: 903
Supply and fix 63 mm dia 30 meter long hose non percolating type conforming to IS 636 complete with male and female coupling conforming to IS: 904
Supply, installation, testing and commissioning of fire hydrant landing valve suitable for hard hydrant , Single headed outlet of 63 mm dia conforming to IS : 5290 with 63 mm female coupling instanataneous outlet ISI marked IS:5290 including cost of MS flanges washer and provision of 80 mm dia MS pipe for tee, cutting, welding etc at all height and all as directed by Engineer-in-Charge. Make:Newage/Omex/Supermex/Getech
Supply, install, test and commissioning of weather proof standard hose cabinet outdoor type suitable for accommodating single headed hydrant valve made of not less than 16 SWG MS sheet having central opening glazed door (4 mm thick clear glass) including necessary locking arrangement with handle for housing two Nos, 30 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (one coat of primer and two coats of fire red colour). The cabinet shall be mounted on suitable raised brick masonry platform or on MS Angle iron frame as directed by engineer-in-charge. The words "FIRE" to be painted on the box complete all as specified and directed. Make: Getech/Minimax/Newage
Supply and fix 80mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set . Butterfly valve shall be cast iron body confirming to IS: 13095 with following details: (a) Disc shall be CI heavy duty electro less nickel-plated abrasion resistant. (b) The shaft shall be EN-8 Carbon Steel with low friction nylon bearings. (c) The seat shall be drip tight constructed by bonding resilient elastomer inside a rigid backing. (d) Built-in flanged rubber seals. (e) Actuator to lever operated for valves above ground and „T‟ keys operated valves below ground. Manufacturer's details on fixing and installation will be followed.
Supply and fix 100mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set . Butterfly valve shall be cast iron body confirming to IS: 13095 with following details: (a) Disc shall be CI heavy duty electro less nickel-plated abrasion resistant.b) The shaft shall be EN-8 Carbon Steel with low friction nylon bearings. c) The seat shall be drip tight constructed by bonding resilient elastomer inside a rigid backing. d) Built-in flanged rubber seals. e) Actuator to lever operated for valves above ground and „T‟ keys operated valves below ground. Manufacturer's details on fixing and installation will be followed.
Supply and fix 150mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set .Butterfly valve shall be cast iron body confirming to IS: 13095 with following details: a) Disc shall be CI heavy duty electro less nickel-plated abrasion resistant. b) The shaft shall be EN-8 Carbon Steel with low friction nylon bearings. c) The seat shall be drip tight constructed by bonding resilient elastomer inside a rigid backing. d) Built-in flanged rubber seals. e) Actuator to lever operated for valves above ground and „T‟ keys operated valves below ground. Manufacturer's details on fixing and installation will be followed.
Supply and fix 200mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set .Butterfly valve shall be cast iron body confirming to IS: 13095 with following details: a) Disc shall be CI heavy duty electro less nickel-plated abrasion resistant. a) Disc shall be CI heavy duty electro less nickel-plated abrasion resistant. b) The shaft shall be EN-8 Carbon Steel with low friction nylon bearings. c) The seat shall be drip tight constructed by bonding resilient elastomer inside a rigid backing. d) Built-in flanged rubber seals. e) Actuator to lever operated for valves above ground and „T‟ keys operated valves below ground. Manufacturer's details on fixing and installation will be followed.
Supply and fix Dual plates CI wafer type check valve, 80 mm bore tested to pressure of 15Kg/ Sqcm complete set
Supply and fix Dual plates CI wafer type check valve, 150 mm bore tested to pressure of 15Kg/ Sqcm complete set
Supply and fix Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm including all required accessories.
Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
Supply and fix Gun metal fire brigade inlet connection (suction collecting head) consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia sluice valve (one no 150mm dia NRV), and 150mm dia flanged outlet complete with all accessories.
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete
Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete
Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete
Supply and fix Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete
Supply, installation & testing of mild steel flanged pipe (IS:1239 part-I) heavy class (class 'C' ) including cutting, screwing, welding supporting of pipe etc. Complete with forged steel / butt welded fittings viz. Tees, bends, elbows, flanges, reducers, clamps / hangers etc. Including cutting holes and chases in brick or RCC walls/slabs and making good the same complete including painting of pipes, fittings & steel work with one coat of primer and two or more coats of synthetic enamel paint of approved make, shade and dia of following size :-
(a) 25 mm dia
(b) 32 mm dia
(c) 40 mm dia
(d) 50 mm dia
(e) 65 mm dia
(f) 80 mm dia
(g) 100 mm dia
(h) 150 mm dia
(j) 200 mm dia
(k) 250 mm dia
Supply and Fix ICV / Alarm gong (Intermittent hydraulic alarm with alarm gong and water motor Alarm) 150 mm
Supply and fixing Universal/differential type pressure switch of required calibration for Automatic operation of fire fighting System complete with all accessories. Make: Danfoss/Indfoss.
Supply and Fixing Flow switch 80mm dia
Supply and Fixing Flow switch 100mm dia
Supply and Fixing Flow switch 150mm dia
Supply and Fixing Pipe Support for all types of pipes including hangars / fastners / elbows/ supports / tees
Supplying and fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926.
Providing & fixing of heavy class M.S. pipes of 150 mm dia conforming to IS: 1239/3589 in trench (external work) Providing thrust block at distance specified as per specifications. (Pipe shall be provided with anti corrosive protective treatment with coal tar/asphalt tape confirming to IS: 10221 standard complete as per specification). All work complete as per specification and as directed by Engineer-In-Charge.
Supplying, fixing, testing and commissioning of resilient rubber neoprene lined single arch vibration eliminators suitable for raw water upto 45 deg. C. temperature working pressure 7 kg/ sq.cm and test pressure 14 kg/sq.cm for the following :-
(a) 80mm dia
(b) 100mm dia
150 mm dia
Supplying, installation, testing and commissioning of annunciation panel made out of not less 1.6 mm thick CRCA sheet powder coated in approved colour with locking arrangement, audio and visual indication of fault and operation of automatic sprinkler, system monitoring including providing and fixing the following i/c connections interconnections etc. complete as required. The panel shall be Micro-processor type/solid state type. Monitoring 31Nos. of flow switches. Monitoring the open circuit, short circuit and earth fault in control cable between panel and flow switches. Battery charger trickle cum boost to take complete load of annunciation panel complete with indication of low Battery voltage, mains failure and other accessories including providing and fixing of 2 Nos. 12 volts 24 AH each sealed maintenance free batteries and with audible alarm as required.
Providing and fixing 25 mm dia inspecting & testing assembly with gunmetal valve, gunmetal sight glass(if required), bypass valve & connected to drain line. (Make- GIACOMINI, AGF, Newage)
Providing and fixing mechanical foam type ISI marked (AFF) type fire extinguishers fitted with forged brass squeeze lever discharge valve, confirming to IS : 15683 : 2006, complete with initial refill consisting of ISI marked cartridge of 60 gms capacity conforming to IS 4989, suitable for operating between +50 degree centrigrade to +55 degree centrigrade, fire rating Class -3A & 34B of capacity 9 Liters.
Providing and fixing fire extinguisher ISI marked carbon dioxide type confirming to IS 15683 :2006 (old IS : 2878) made from seameless cylinder confirming to IS : 7285 duly approved by chief controller of explosive, Nagpur, fitted with ISI marked controlled valve confirming to IS : 3224, Hogh pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, suitable for operating between -30degree centrigrade to +55 degree centrigrade, fire rating class -138. of 4.5 Kg capacity cylinder
Providing and fixing water stored pressure CO2 type extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge with internal discharge tube, discharge nozzle suspension bracket confirming to IS : 15683 : 2006 (old IS :6234) duly charged with purged water and pressurized with nitrogen gassuitable for operating between +50 degree centrigrade to +55 degree centrigrade, fire rating class -3A of capacity 9 Liters
Providing and fixing stored pressure fire extinguisher ISI marked, Powder type suitable for Class A, B, C Fire consisting with discharge hose and nozzle of welded cylider, squeeze lever discharge valve fitted with pressure indicating gauge, intyernal discharge tube, discharge nozzle suspension bracket confirming to IS : 15683 : 2006 (old IS :6234) duly charged with ISI marked Mono Ammonium Phosphate base ABC powder confirming to IS : 14609 and pressurized with nitrogen gassuitable for operating between -30 degree centrigrade to +55 degree centrigrade, fire rating class 1A & 13B. of Capacity 4 Kg
(WET RISER SYSTEM - PUMPING EQUIPMENTS) Supply, Installation, Testing and Commissioning of Electric Driven Main Fire and Sprinkler Pump suitable for auto operation & consisting of following: complete in all respect as required. Horizontal Split casing type, centrifugal, multistage, pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at specified flow of 2850 LPM at 100 Mtr. head confirming to IS 1520-1980.Suitable HP squirrel cage induction motor, TEFC synchronous speed 1450 RPM (with permissible slip), suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-' F' insulation, confirming to IS-325-1978Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation (minimum 6" above from ground floor) duly plastered, with anti vibration pads etc. complete as per manufacturer's design & standards and as per detailed specifications. (Make- lubi, wilo & grundfoss).
Supply, Installation, Testing and Commissioning of Diesel Engine Driven Main Fire Pump suitable for auto operation and consisting of following: complete in all respect as required. Horizontal Split casing type, centrifugal, multistage pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2850 LPM at 100 Mtr. head confirming to IS 1520-1980.Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories / system, fuel oil filter, lubricant oil pump with filter, 2 Nos. starting batteries of 180 AH capacity each with suitable angle iron stand, engine starting panel having all the controls meters, gauges, tachometer, hour meters, starting switch with keys for manual starting, auto starting mechanism, 24 Volts electric starting equipment, Diesel Tank for 8 hrs continuous running of diesel engine, having minimum capacity of 200 Ltrs. (tank made out of 3mm thick M.S. Sheet with filling Cap, drain Cock, diesel indicator duly mounted on M.S. angle) exhaust pipe extended upto 1 mtr. outside pump house, duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, exhaust residential silencer, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories / system, fuel oil filter, lubricant oil pump with filter, 2 Nos. starting batteries of 180 AH capacity each with suitable angle iron stand, engine starting panel having all the controls meters, gauges, tachometer, hour meters, starting switch with keys for manual starting, auto starting mechanism, 24 Volts electric starting equipment, Diesel Tank for 8 hrs continuous running of diesel engine, having minimum capacity of 200 Ltrs. (tank made out of 3mm thick M.S. Sheet with filling Cap, drain Cock, diesel indicator duly mounted on M.S. angle) exhaust pipe extended upto 1 mtr. outside pump house, duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, exhaust residential silencer, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S. fabricated Common base frame, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation (minimum 6" above from ground floor) duly plastered, with anti vibration pads etc. complete as per manufacturer's design & standards and as per detailed specifications.
Supplying, Installation, Testing and Commissioning of Electric Driven Pressurization Pump (Jockey Pump) suitable for auto operation and consisting of following: complete in all respects as required.Horizontal type, centrifugal end suction type pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal, gland packing and flow of 180 LPM at 100 Mtr. head confirming to IS:1520-1980.Suitable HP squirrel cage induction motor TEFC type 2900 RPM suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class -'F' insulation, confirming to IS:325-1978.Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation (minimum 6" above from ground floor) duly plastered, with anti vibration pads etc. complete as per manufacturer's design & standards and as per detailed specifications. (Make- lubi, wilo & grundfoss)
Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards, For automatic control of Fire Pumps, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.
1. Supporting rigid steel framework. 2.Cubicle type, 14 gauge CRCA sheet steel enclouser. 3. Complete with interconnections and distribution bus bars. 4.Proper bonding to earth. 5. Painting/lettering on Breakers and distribution boards, the location they. 6.Providing cable clamps / supports within distribution boards cable alley 7.TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate 8.All MCB’s shall be of minimum 10 KA breaking capacity. 9.All motor feeders MCCBs shall be of motor duty. 10.Distribution panels shall be Powder Coated with Siemens gray paint shade 11.. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. 12.IP 42 for indoor panels. 13. IP 54 for kitchen and laundry panels. 14.IP 55 for outdoor panels. 15.All MCCB’s shall be provided with operating mechanism for door interlock. 16.Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars.
17. Tinned copper earth bus shall be provided through out the length of each board. 18.All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS. 19.All hinged door shall be earthed through 4.0 sq mm tinned braided copper wire. 20.All panels shall have provision of the following: 21.Pad locking of Switch board doors. 22.Pad locking of MCCB’s handles in “OFF” Position. 23.Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor. 24.All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. 25.All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. 26.All PTs / control transformer shall be provided with centre tap earth secondary. 27.All DOL & Star-Delta Starters shall be provided with SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor. 28.The Panel fabricator shall provide Al./ Copper Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers.
29.Readymade 16 SWG Sheet steel Enclosure with cutout For MCBs. 30. The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. 31. Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as described below . (A) Protection Release Microprocessor Based (PRMB-1) Over-current/long time protection range 40% - 100 % with Time setting short circuit /short time protection range 100% - 1000 % with Time settingInstantaneous short circuit Protection range 150% - 1200 % with Time setting Earth Fault Protection range 20% - 100 % with Time setting Under voltage & over voltage protection Reverse power Current unbalance Phase sequence Measurements Voltage Current Power (Active,Reactive & Apparent) Energy ((Active,Reactive & Apparent) Power factor Frequency (B) Protection Release Microprocessor Based (PRMB-2) Over-current/long time protection range 40% - 100 % with Time setting short circuit /short time protection range 100% - 1000 % with Time setting Instantaneous short circuit Protection range 150% - 1200 % with Time setting Earth Fault Protection range 20% - 100 % with Time setting Measurements Current .
Supplying, Installation, Testing and Commissioning of Quartz Bulb Quick Responce Residential type GM Sprinkler head, as per IS : 15105/TAC Guidlines suitable to operate at 68 Degree Centigrade.
Supplying, Installation, Testing and Commissioning of Corrugated stainless steel, AISI-304, unbraided, flexible sprinkler pipe drops of Rosseette 25 mm dia, of following length and maximum working pressure of 175 PSI with all accessories and clamps as required. The Flexible pipe drop shall be UL approved. The pipe drop shall be of 0.7 Meter length..
Supply and fixing swing flap non return valves 100 mm size suitable for water application type PN 14 with short overall length, angle when flap is fully open 60 degree, metal hinged , two springs suitable for fittings with flange pipe metal to metal sheet complete.
SCH 'A PART XVI (ARBORICULTURE) Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
supplying and stacking of good earth (fresh garden soil) site including royalty and carriage with any lead complete all as specified.
supplying and stacking of farmyard manure at site including royalty and carriage with any lead complete all as specified.
Material and labour for planting and developing lawn grass (phospolen) including following (a) Preparing of soil base by excavtion/ploughing and loosening of ground upto 15cm and removing unwanted material grass stone etc to a distance exceeding 50m but not exceeding 250m (b) Mixing good earth (fresh garden soil) & farm yard manure throughly in 2:1 proportion and filling excavate area to a height of 15cm and levelling including suitable quantity of oil cake, bone dust, anti termite powder completely. (c) Watering on previous night and planting required variety of lawn grass and maintaining for a minimum period of 180 days or till formation of well established lawn grass whichever is later blanket to the satisfacation of Engg-In-Charge by watering. weeding clipping and rolling etc complete.
Material and labour for planting and developing different type hedge palnts naming alternathera. Codiaeim, maranta etc including following (a) Preparing of soil base excavation/ploughing and loosening of ground upto 30cm and removing unwanted material, grass stone etc to a distance exceeding 50m but not exceeding 250m and 250m width of edge. (b) Mixing good earth (fresh garden soil) & farm yard manure thoroughly in 2:1 proportion and filling excavate area to a height of 15cm and levelling including suitable quantity of oil cake, bone dust, anti termite powder completely. (c) Watering on previous night and planting required variety of lawn grass and maintaining for a minimum period of 180 days or till formation of well established lawn grass whichever is later blanket to the satisfaction of Engg-In-Charge by watering, weeding, clipping and rolling etc complete.
Material and labour for planting Raphis/Pritchardia Palm for area beautification or landscape including following (a) Digging hole of size 600mm dia x 600mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting of Orange/Crape/Tagar Jasmine including following:- (a) Digging hole of size 600mm dia x 600mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting different colours of bogun baily including following (a) Digging hole of size 600mm dia x 600mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting different type coconut (Ganga bandhan) including following (a) Digging hole of size1200mm dia x 1200mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting different colours of oleander (Hindi-Kaner, Bengali-Kabirei) of 2 feet height including following (a) Digging hole of size 600mm dia x 600mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting and developing pyramid type Ahoka tree (Bengali-Deodar)/different type Champa tree of 2 feet height including following (a) Digging hole of size 900mm dia x 900mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting different type Araceae (philodendron/Alocasia)/Ficus star light including following (a) Digging hole of size 300mm dia x 300mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting different type Araceae (philodendron/Alocasia)/Ficus star light including following (a) Digging hole of size 300mm dia x 300mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
Material and labour for planting different type and different colours of Russelia including following (a) Digging hole of size 600mm dia x 600mm depth, removing and conveying excavated soil to a distance exceeding 50m and not exceeding 250m. (b) Filling the hole with fresh garden soil and farm yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-In-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed.
SCH 'A PART XVII (COMPREHENSIVE MAINTENANCE, MANNING AND OPERATION OF LIFT, HVAC, FIRE FIGHTING AND FIRE ALARM SYSTEM DURING DLP AND THREE YEARS BEYOND DLP) Note : This sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
COMPREHENSIVE MAINTENANCE, MANNING AND OPERATION OF LIFT
Manning and operation during defect liability period (DLP) for one year for lifts installations complete all as specified and as directed during first year commencing from the next day after completion of the work providing requisite manpower all as per OEM recommendation of operation. (the operator should have own conveyance and communication system like mobile etc) LIFT: (08 passenger 02 Nos and 13 passenger 04 Nos) (i) Operation would include any defective equipments/parts of the lifts shall be replaced without any extra cost during defect liability period. (ii) Regular cleaning, lubrication, adjustment and adequate servicing by authorized competent persons at such intervals as the type of equipments and frequency of service demand. (iii) Fortnightly Maintenance: - Each lift is required to be visited by designated maintenance team from OEM and carry out specified maintenance activities to ensure upkeep of lift is user work condition. (Details of fortnightly maintenance schedule is available with MES Technical Instruction (TI-02/2012) at MES website as Appx-A). (iv) Monthly Maintenance: - Each lift is required to be visit by designated team from OEM comprising skilled mechanics shall check all electrical components which are required to be kept in controlled condition. Details of check are listed required to be carried out are listed at Appx-B with MES Technical Instruction (TI-02/2012). A proper visit required to be maintained duly counter signed by supervisory staff with their remarks in monthly maintenance record in respective lift. (v) Quarterly maintenance: - Each lift is required to be provided specific maintenance every quarter (by OEM). Details of check are listed required to be carried out are listed at Appx-C with MES Technical Instruction (TI-02/2012). (vi) Annual maintenance Schedule: - Certain specified maintenance is required to be performed on each lift to ensure longevity and useful life working of lift details of maintenance required to be done and person responsible is provided in Appx-D at MES Technical Instruction (TI-02/2012). (vii) Providing of one skilled lift mechanic cum lift operator per shift for daily operation with ITI certification and minimum 3 years experience in the relevant field for two shifts of 08hrs duration for each day including Sunday and holidays.
Comprehensive maintennce, Manning and operation after defect liability period (DLP) for one year for lifts installations complete all as specified and as directed during first year commencing from the next day after completion of the defect liability period providing requisite manpower with all consumable items all as per OEM recommendation of operation. (the operator should have own conveyance and communication system like mobile etc) LIFT: (08 passenger 02 Nos and 13 passenger 04 Nos) (i) Operation would include any defective equipments/parts shall be replaced without any extra cost. (ii) Regular cleaning, lubrication, adjustment and adequate servicing by authorized competent persons at such intervals as the type of equipments and frequency of service demand. (iii) Fortnightly Maintenance: - Each lift is required to be visited by designated maintenance team from OEM and carry out specified maintenance activities to ensure upkeep of lift is user work condition. (Details of fortnightly maintenance schedule is available with MES Technical Instruction (TI-02/2012) at MES website as Appx-A). (iv) Monthly Maintenance: - Each lift is required to be visit by designated team from OEM comprising skilled mechanics shall check all electrical components which are required to be kept in controlled condition. Details of check are listed required to be carried out are listed at Appx-B with MES Technical Instruction (TI-02/2012). A proper visit required to be maintained duly counter signed by supervisory staff with their remarks in monthly maintenance record in respective lift. (v) Quarterly maintenance: - Each lift is required to be provided specific maintenance every quarter (by OEM). Details of check are listed required to be carried out are listed at Appx-C with MES Technical Instruction (TI-02/2012). (vi) Annual maintenance Schedule: - Certain specified maintenance is required to be performed on each lift to ensure longevity and useful life working of lift details of maintenance required to be done and person responsible is provided in Appx-D at MES Technical Instruction (TI-02/2012). (vii) Providing of one skilled lift mechanic cum lift operator per shift for daily operation with ITI certification and minimum 3 years experience in the relevant field for two shifts of 08hrs duration for each day including Sunday and holidays.
All as per Item No 23.03 but for second year after completion of first year. (i.e after completion of Item No 23.03).
All as per Item No 23.03 but for third year after completion of second year. (i.e after completion of Item No 23.04).
COMPREHENSIVE MAINTENANCE, MANNING AND OPERATION OF HVAC
Manning and operation during defect liability period (DLP) for one year for Air Conditioning Plants complete all as specified and as directed during first year commencing from the next day after completion of the work providing requisite manpower all as per OEM recommendation of operation. (the operator should have own conveyance and communication system like mobile etc) AC PLANT (VRF TYPE WITH 38 INDOOR HIGH WALL UNITS) & VENTILATION SYSTEM: Operation would include any defective equipments/parts of the AC plant and ventilation system shall be replaced without any extra cost during defect liability period. (i) Daily maintenance: - Inspection of all indoor and outdoor unit and carryout necessary preventive maintenance if required. (ii) Weekly Maintenance: - (a). Cleaning of water line pot strainer, if required. (b). Checking of electrical connections. (c) Cleaning of nozzles of water cooled air pressurization blower. (d). Checking of water logging. ( e) Checking of system for lockage of gas. (f). Washing cleaning of filters (iii) Monthly Maintenance: - (a). Cleaning of oil filters of compressor. (b). Cleaning of suction line strainer of compressor. (c) Checking and tightening of foundation bolts of equipments. (d). Cleaning of liquid line strainer. Checking of correctness and calibration of all safety and automatic controls. Replacement of defective ones. (iv) Seasonal Maintenance: - (a). Changing of compressor oil (b). Checking of all pumps ©. Checking of bearing clearance (d). De-scaling of condenser tubes and oil coolers tubes. ( e). Cleaning and greasing of all bearings (f). Painting of compressor, motor, pipe lines pumps etc. (g). Maintenance of all electrical switchgears in the control panel. (v) Providing of one skilled AC mechanic cum Air conditioner operator per shift for daily operation with ITI certification and minimum 3 years experience in relevant field for two shifts of 08hrs duration for each day including Sunday and holidays
Comprehensive maintennce, Manning and operation after defect liability period (DLP) for one year for AC plant installations complete all as specified and as directed during first year commencing from the next day after completion of the defect liabilit period providing requisite manpowerwith all consumable items all as per OEM recommendation of operation. (the operator should have own conveyance and communication system like mobile etc) AC PLANT (VRF TYPE WITH 38 INDOOR HIGH WALL UNITS) & VENTILATION SYSTEM: Operation would include any defective equipments/parts shall be replaced without any extra cost. (i) Daily maintenance: - Inspection of all indoor and outdoor unit and carryout necessary preventive maintenance if required. (ii) Weekly Maintenance: - (a). Cleaning of water line pot strainer, if required. (b). Checking of electrical connections. (c) Cleaning of nozzles of water cooled air pressurization blower. (d). Checking of water logging. ( e) Checking of system for lockage of gas. (f). Washing cleaning of filters (iii) Monthly Maintenance: - (a). Cleaning of oil filters of compressor. (b). Cleaning of suction line strainer of compressor. (c). Checking and tightening of foundation bolts of equipments. (d). Cleaning of liquid line strainer. (e) Checking of correctness and calibration of all safety and automatic controls. Replacement of defective ones. (iv) Seasonal Maintenance: - (a). Changing of compressor oil (b). Checking of all pumps ©. Checking of bearing clearance (d). De-scaling of condenser tubes and oil coolers tubes. ( e). Cleaning and greasing of all bearings (f). Painting of compressor, motor, pipe lines pumps etc. (g). Maintenance of all electrical switchgears in the control panel. (v) Providing of one skilled AC mechanic cum Air conditioner operator per shift for daily operation with ITI certification and minimum 3 years experience in relevant field for two shifts of 08hrs duration for each day including Sunday and holidays
All as per Item No 23.08 but for second year after completion of first year (i.e after the completion of Item No 23.08).
All as per Item No 23.08 but for third year after completion of second year (i.e after the completion of Item No 23.09).
COMPREHENSIVE MAINTENANCE, MANNING AND OPERATION OF FIRE FIGHTING AND FIRE ALARM SYSTEM
Manning and operation during defect liability period (DLP) for one year for fire fighting and fire alarm system complete all as specified and as directed during first year commencing from the next day after completion of the work providing requisite manpower all as per OEM recommendation of operation. (the operator should have own conveyance and communication system like mobile etc) Operation would include any defective equipments/parts of the lifts shall be replaced without any extra cost during defect liability period. (i) The checks and maintenance specified in the Technical Instruction (TI-01/2012) needs to be strictly followed, executed and recorded. (TI is available in MES website) (ii) The maintenance chart available in the Technical instruction (TI-01/2012) is required to be followed and a report is to be submitted accordingly. (iii) Providing of two skilled (One operator qualified for the fire fighting system and trained by OEM and one operator qualified or fire detection and alarm system and trained by OEM) fire fighting system operator per shift for daily operation with minimum 3 years experience in relevant field for three shifts of 08hrs duration for each day including Sunday and holidays
Comprehensive maintennce, Manning and operation after defect liability period (DLP) for one year for fire fighting and fire dectation installations complete all as specified and as directed during first year commencing from the next day after completion of the defect liability period providing requisite manpowerwith all consumable items all as per OEM recommendation of operation. (the operator should have own conveyance and communication system like mobile etc) Operation would include any defective equipments/parts shall be replaced without any extra cost. (i) The checks and maintenance specified in the Technical Instruction (TI-01/2012) needs to be strictly followed, executed and recorded. (TI is available in MES website) (ii) The maintenance chart available in the Technical instruction (TI-01/2012) is required to be followed and a report is to be submitted accordingly. (iii) Providing of two skilled (One operator qualified for the fire fighting system and trained by OEM and one operator qualified or fire detection and alarm system and trained by OEM) fire fighting system operator per shift for daily operation with minimum 3 years experience in relevant field for three shifts of 08hrs duration for each day including Sunday and holidays
All as per Item No 23.13 but for second year after completion of first year (i.e after completion of Item No 23.13)
All as per Item No 23.13 but for third year after completion of second year (i.e after completion of Item No 23.14)
NOTE (Applicable for all items /parts) :- The bidders /contractors are advised to refer Notes on BOQ/SCH'A' before entry /quoting the rates. SCHEDULE 'A' PART-XVIII PROVISIONAL LUMP SUM for RCC Canopy in front portion of main building, a Block of Garage(G+1), pump house building including underground sump, National Flag Post, Safety Hook on the roof Top and Antena Bases complete all as directed. Note : Provisional Lump Sum inserted in this Sch will be considered as one item priced at per SSR 2010. The bidder shall quote lump sum amount against this item and accordingly percentage shall be derived automatically by the system in the Excel Sheet BOQ based on the amount quoted against this item by the bidder.
Removal of following items (unfit for construction activities) from the work site and disposal of the same outside MOD Land or Coast Guard land complying the instructions of local civil authorities in the matter all as directed: --- (i) MS Finisher- 1 Nos (ii) Cement Bags - 56 Nos (iii) Bentonite Power - 50 Nos (iv) Fan regulator - 3 Nos (v) 15 Amps Switch (Anchor) - 1 Nos (vi) 5 Amps Scoket -3 Nos (vii) AC Starter (Crabtree Make) -1 Nos (viii) Old metal halide flood light-500W -4 Nos
SOOD ASSOCIATES PVT LTD
surendra infrastructure pvt ltd
Hariom Projects Pvt Ltd
Komal Buildcon Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid