Tender Value
₹44.0 L
EMD Value
₹88,100
Closing Date
9 Feb 2022, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
PROVN OF FIRE ALARM SYSTEM IN A AND B HANGER AND ANNEXE BLDG OF A FLT AT AF STN PALAM UNDER GE AF PALAM DELHI CANTT-10
2022_MES_500969_1
GENP-71/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹88,100
Yes
5 Apr 2022
11 Jan 2022
10 Feb 2022
11 Jan 2022
9 Feb 2022
27 Jan 2022
Amount
S&F detector complying with and type certified to EN 45 addressable type flame detectors with UV/IR detection capacity (Note:-addup cost of module to be a complete set the type of module shall be relay type module).Make-Ceasefire/Hochiki/siemens/honeybell
M & L for Addressable monitor module suitable for addressable type flame detector. Make: Siemens/Honeywell/ Ceasefire/Hochiki
S&F addressable control module HZM suitable for addressable type flame detector. Make: Siemens/Ceasefire/ Hochiki/honeybell
M & L for Active Full function Repeater Panel complies with EN54-2, Network up to 64 panels/repeaters,Programmable one touch test mode,Powerful and versatile cause & effect programming,Cause & effect wizard including:Cause & effect action,Disablement configuration,Test mode configuration 5.25 amp power supply to EN54 part 4,Large graphic display,In built help and alarm information screens,Real time clock,Stylish enclosure design,Soft-touch tactile buttons,2 programmable function buttons,3 programmable front panel mounted LED’s,Improved Front loading Printer (optional)Up to 512 programmable inputs/outputs perpanel via 2 wire RS485 serial link (optional).Simple Windows® graphical configuration utility.It has IP rating IP30. Make: Ceasefire/ Hochiki/ honeybell /siemens
S&F adopter for power supply to flame detector of capacity 24 volt complete, all as specified and directed by Engineer- in-Charge. Make: Philips/LG/Logitec/Ceasefire/Hochiki/siemens/honeybell
Supply , laying and fixing on wall or in trench/ducts, cable 4 Core 1.5 Sqmm FRLS suitale for power supply to UV/IR flame detector armoured cable copper conductor including steel saddles, screw for fixing of cable on wall /roof/ceiling and ducts in PVC heavy duty conduit ISI marked of size 25mm dia complete all as specified and as directed by Engr-in-Charge.(Note : Rate of PVC condute & steel saddle are deemed to be included in the quoted rate). Make :Havells /Finolex/Plaza
Supply ,laying and fixing on wall or in trench/ducts, cable 2 Core 1.5 Sqmm FRLS suitale for power supply to UV/IR flame detector armoured cable copper conductor including steel saddles, screw for fixing of cable on wall /roof/ceiling and ducts in PVC heavy duty conduit ISI marked of size 25mm dia complete all as specified and as directed by Engr-in-Charge.(Note : Rate of PVC condute & steel saddle are deemed to be included in the quoted rate). Make : Havells /Finolex/Plaza
Supply & fixing fire alarm control panel complying with BSEN 54 single loop panel of capacity from 99 detectors 200 detectors and module 1 loops networkable surface mounting FACP certified to EN54-2/EN54-4 norms can be Networkable capability of up to 64 Panels with 500 software zones. Large with 8x40 character LCD . The FACP shall be certified as meeting the requirements of EN54-2 and EN54-4 by a suitable, notified body. In order to facilitate re-configuration and system extension, the allocation of addresses to devices shall be independent of their physical arrangement on the loops and Sensitivity adjustment and Drift Compensation. The FACP shall capable analogue addressable wired and wireless sensors & modules Up to 127, plus 127 analogue base sounder / Beacon for total 254 point shall be configured on each addressable loop. The FACP shall have an event log capable of storing the last 500 events that have occurred. Loop powered sounders incorporated as a sensor bases shall be available. The FACP shall have the capability to support sub-addressing of addressable modules. The FACP shall monitor all critical system components and interconnections, internal and external, such that a failure, which would prevent the correct operation of the alarm functions, causes the FAULT indicator to light and a message to be given on the alphanumeric display within 60 seconds of occurrence. The FACP shall support minimum Four access levels,flash EPROM, programmable sounder circuits. The FACP Shall be housed in Ms Powder coated Cabinet, complete with exclusive Notification Circuits, and with Fire, Fault & Auxiliary Relays.The Panel shall support to programmed as a node on a peer to peer network with other Panels. Make: Siemens /HoneywellCeasefire/Hochiki
Supply, installation, testing and commissioning of Photo electronic type smoke cum heat detector IP67 rated , having removable high performance chamber with Twin fire LED's allow 360 degree veiwing, lock mechanism ( sensor to base), employ two heat sensing elements with different thermal characteristics to provide a rate of rise dependent response.Electronically addressed, approved by LPCB. Flat FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM).(EN-54 approved) conforming to IS-11360 -1985 having dual ionized chamber meant for easy detection of high carbonized fumes by means of light emitting principle complete with base, UL FM LPCB complete all as specified and directed by engineer in charge. Make: Ceasefire/Hochiki /siemens/ honeybell
Supply & fixing addressable manual call point/pull station single action type with gold plated SPST contacts Analogue Addressable Manual Call Point having status LED for Alarming & standby mode,inbuild short circuit isolator,Electronically addressed approved by LPCB as EN54-11: 2001 . Rapid response using operation of a call point to the system indicating fire condition is typically less than 1.5 seconds FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and Time saving complete all as specified and directed by engineer in charge. . Make: Ceasefire/Hochiki/siemens/honeybell
Suply & fixing UPS 1.0 KVA suitable for working on 230 volts 50 Hz AC supply with all connections in and including copper conductor complete all as specified and directed by engineer in charge. Make: Microtec/Sukam/APC
Supply & fixing of hooter with control moudle complete all as specified and directed by engineer in charge. Make: Ceasefire/Hochiki/siemens/honeybell
Supply, installation, testing and commissioning of microprocessor based 4 Zone conventional fire alarm control panel robustly designed and easy to operate, fully compliant with and tested to BS EN 54-2 and BS EN 54-4, Compatible for use on BS5839, Part 1, 2002 installation, 2 wire repeaters and ancillary boards, fully programmable using simple menu options, simple, single board construciton, installer friendly, compatible with Hochiki, conventional range of devices, two monitored sounder outputs, 3 Amp power supply, auxiliary power output, The control must be EN 54 approved, complete all as specified and as directed by Engr-in-Charge.Make : Ceasefire/Hochiki/siemens/honeybell.
M&L for drilling holes under road/hard standing by using manual tool for laying pipe for protection of cable etc without disturbing top suface and making good the disturb surface, complete all as specified and as directed by the Engr-in-Charge.
M&L for prepainted perforated MS cable tray of size 150mmX50mmX2 mm for conductor by means of proper size steel heavy duty fasteners of size 150 mm X 12 mm. The cable tray is required to be mounted on angle iron frames as per design in and including clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding. Each frame is required to be fixed on wall by means of 3 steel fasteners 150x12 mm size. The cable trays are to be jointed by factory made steel jointers of suitable size and shape all as specified and directed by Engineer- in -charge.
Continental Engineers and contractors
Third Wave Services Pvt Ltd
Satish Kumar Gupta
T.I.John and Sons
FIRE PROTECTION SYSTEM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .