Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.4 L+₹1.9 L (5.15%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹44.2 L+₹7.7 L (21.0%)Rejected-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹44.5 L+₹7.9 L (21.7%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹52.6 L+₹16.1 L (43.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Sept 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIRS RENEWAL OF APFC PANEL, AMF PANEL, ACBs, MCCBs, CAPACITOR, AMMETER AND CONNECTED ITEMS UNDER AGE EM NO II OF GE UTILITY SECUNDERABAD
2020_MES_367541_1
GE(U)/SEC/TOKEN/34 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE UTILITY SECUNDERABAD
₹70,000
Yes
18 Dec 2020
8 Aug 2020
7 Sept 2020
8 Aug 2020
5 Sept 2020
24 Aug 2020
Amount
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for capacitor banks, ( control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 400 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 45cm below ground level and 15cm above ground level and comprising of the following
(a) MCCB, 4 pole, 500 Amps with ultimate breaking capacity Icu - 50kA at 415 Volts and microprocessor release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 50kA, overload setting 70% to 100% - 01 Nos ( As Incomer) (b) MCCB, 3 pole, 125 Amps with ultimate breaking capacity Icu - 16kA at 415 Volts and thermal magnetic release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 16kA- 02 Nos (c) MCB, 3 pole, 40-63 Amps with ultimate breaking capacity Icu - 10kA at 415 Volts conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 10kA-03Nos. (d) MCB, 3 pole, 6-32 Amps with ultimate breaking capacity Icu - 10kA at 415 Volts conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 10kA-03Nos. (e) Capacitor Banks, 50kVAR (1X50kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos (f) Capacitor Banks, 50kVAR (1X50kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos (g) Capacitor Banks, 25kVAR (1X25kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos (h) Capacitor Banks, 25kVAR (1X25kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos (i) Capacitor Banks, 20kVAR (1X20kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos (j) Capacitor Banks, 15kVAR (1X15kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 120 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable at MH and comprising of the following:-
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm a and comprising of the following:-
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable at MH and comprising of the following:-
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable at MH and comprising of the following:-
Supply only 4 pole MCCB 200 amps 25kA,50Hz,440v with adjustable settings in new panel including necessary wiring & misc accessroies for satisfactory completion of job one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only 4 pole MCCB 160 amps 25kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only 4 pole MCCB 125 amps 16kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only 4 pole MCCB 100 amps 16kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only of 4 pole MCCB 32-63 amps 16kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only of 3 pole MCB 16-32 amps,C-curve,10kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only of 3 pole MCB 40-63amps,C-curve,10kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only heavy duty box type capacitors 5kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only heavy duty box type capacitors 10kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only heavy duty box type capacitors 15kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only heavy duty box type capacitors 20kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply only heavy duty box type capacitors 25kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing elimator push button in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
M& L for control wiring,relay programming and panel testing complete all as directed by Engr-in-Charge.
Supply&Fixing heavy duty box type capacitors 5kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 10kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 15kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 20kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 25kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 50kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing ultra heavy duty box type capacitors 20kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing APFC relay 6 stage in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:HPL/L&T/Schnieder
Supply&Fixing APFC relay 8 stages in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:HPL/L&T/Schnieder
Supply&Fixing of capacitor duty contactor suitable for capacitor rating 5 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing of capacitor duty contactor suitable for capacitor rating 10 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing of capacitor duty contactor suitable for capacitor rating 15 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing of capacitor duty contactors suitable for capacitor rating 25 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing of 6 No Auxiliray conactor ,50Hz,240v in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing of 200/5 Amps Current transformer in each phase including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
Supply&Fixing of 400/5 Amps Current transformer in Each phase including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
Shifting of existing APFC(Auto power factor correction) panel by disconnectioning of all electrical/mechanical connections & dismantling of exsiting PCC and install & commissioning in proposed location with suitable Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm complete all as directed by Engr-in-Charge.
SANJEEV CONSTRUCTIONS
omsai thermax engineers
STANDARD AGENCIES
POWER CONSTRUCTION COMPANY
Haasith constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .