Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance 47 MURUGESA NAICKER COMPLEX GREAMS ROAD THOUSAND LIGHTS CHENNAI TAMIL NADU 600006 | CHENNAI | TAMIL NADU | 600006 | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹1.5 L (1.01%)Admitted-Finance | ₹1.5 Cr+₹1.5 L (1.01%) | L2 | Admitted-Finance |
| 3 | L3₹1.7 Cr+₹12.6 L (8.25%)Admitted-Finance 606 ABHIJEET BUILDING I MITHAKHALI SIX ROAD NR ELLISBRIDGE AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹1.7 Cr+₹12.6 L (8.25%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ARCOY INDUSTRIES (INDIA) PVT. LTD. L3 | Beardsell Limited L1 | SRI SAI PROTECTIVE COATINGS L2 |
|---|---|---|---|---|---|---|
| 1.00Preparation of surface, supply and application of requsite coats of primer and paint as specificied including providing ground/ base colour and colour coding bends in piping, making arrows, fluid description and line number and hazard signs on piping stencelling names and number on vessels tools consumable, all hieght, supply of all material, tools consuable, testing appliances, labour supervisior, etc to complete the painting work in all respect and per direction on Towers, Columns, Vessels, Tanks, pipelines Heat Exchangers, Machinary etc as given below : | ||||||
| 1.10 | Primer and paint suitable for temp.above 65 Deg.C. and upto 120Deg C with one coat of Epoxy Red Oxide Zinc Chromate permier and two coats of Epoxy finish paint Refer to Table-I S. no P2 and F1. | 20,750 | M2 | 205.54 ₹42,64,955 Lowest | 280 ₹58,10,000 | 283 ₹58,72,250 |
| 1.20 | Primer and paint suitable for Temp.upto 120 Deg C one coat of Red Oxide Zinc Chromate and Two coats of synthetic enamel finish paint Ref Table -I S. no P1 and F6 | 30,000 | M2 | 238.01 ₹71,40,300 Lowest | 253 ₹75,90,000 | 245 ₹73,50,000 |
| 1.30 | Primer and paint suitable for Temp.upto 120 Deg C with one coat of Red Oxide Zinc Chromate and two coat of heat resisting Aluminium paint, Ref Ref Table -I Sr no F3 | 700 | M2 | 276.43 ₹1,93,501 | 232 ₹1,62,400 Lowest | 232 ₹1,62,400 Lowest |
| 1.40 | Paint with two coat of heat resisting Aluminium paint suitable for temp. above 120 Deg C and upto 250 Deg CRef Table I Sr no F4 | 200 | M2 | 158.64 ₹31,728 Lowest | 201 ₹40,200 | 186 ₹37,200 |
| 1.50 | Primer and paint with one coat of Zinc Phospate perimer and two coats fo Chlorinated rubber paint of finish surface Ref. Table-I S.No.P3 and F2. | 600 | M2 | 279.03 ₹1,67,418 | 243 ₹1,45,800 | 230 ₹1,38,000 Lowest |
| 1.60 | Primer and paint one coat of red oxide zinc chromate primer and two coats of anti corrosive black bitumen(IS-158)Ref.Table-I S.No. P1 and F5 | 2 | MT | 6,995.57 ₹13,991.14 | 764 ₹1,528 Lowest | 7,106 ₹14,212 |
| 1.70 | Paint with two coat of heat resisting Aluminium paint suitable for temp. above 250 Deg C and upto 600 Deg CRef Table I Sr no F7 | 400 | M2 | 295.48 ₹1,18,192 Lowest | 305 ₹1,22,000 | 350 ₹1,40,000 |
| 2.00 | Preparation of surface of Towers, columns, vessels, tanks,heat exchangers, piping rotors,impellers,diffusers etc.by sand, ash & grid blasting process and including arrangement of sandash & grid blasting equipment/ tools,tackles labour supervision etc. and by buffing wheel on : | 500 | M2 | 472.8 ₹2,36,400 | 67 ₹33,500 Lowest | 302 ₹1,51,000 |
| 3.00Application of one coat of suitable paint on Towers, column, vessels, tanks, heat exchanger, pipnig and steel structures etc.: | ||||||
Tender Value
₹1.8 Cr
EMD Value
₹1 L
Closing Date
21 Apr 2025, 3:00 pmClosed
DGM Mechanical
NFL Bathinda
ARC of Painting jobs for the year 2025-26
2025_NFL_231649_1
NFB/MECH/MPC/013/ARC/2025-26
Limited
Paint / Enamel Works
Works
365 days
NFL Bathinda
Please refer tender documents
3 documents required · 3 mandatory
₹0
₹1 L
Yes
13 Jun 2025
29 Mar 2025
22 Apr 2025
29 Mar 2025
21 Apr 2025
29 Mar 2025
29 Mar 2025 - 21 Apr 2025
Amount
Preparation of surface, supply and application of requsite coats of primer and paint as specificied including providing ground/ base colour and colour coding bends in piping, making arrows, fluid description and line number and hazard signs on piping stencelling names and number on vessels tools consumable, all hieght, supply of all material, tools consuable, testing appliances, labour supervisior, etc to complete the painting work in all respect and per direction on Towers, Columns, Vessels, Tanks, pipelines Heat Exchangers, Machinary etc as given below :
Primer and paint suitable for temp.above 65 Deg.C. and upto 120Deg C with one coat of Epoxy Red Oxide Zinc Chromate permier and two coats of Epoxy finish paint Refer to Table-I S. no P2 and F1.
Primer and paint suitable for Temp.upto 120 Deg C one coat of Red Oxide Zinc Chromate and Two coats of synthetic enamel finish paint Ref Table -I S. no P1 and F6
Primer and paint suitable for Temp.upto 120 Deg C with one coat of Red Oxide Zinc Chromate and two coat of heat resisting Aluminium paint, Ref Ref Table -I Sr no F3
Paint with two coat of heat resisting Aluminium paint suitable for temp. above 120 Deg C and upto 250 Deg CRef Table I Sr no F4
Primer and paint with one coat of Zinc Phospate perimer and two coats fo Chlorinated rubber paint of finish surface Ref. Table-I S.No.P3 and F2.
Primer and paint one coat of red oxide zinc chromate primer and two coats of anti corrosive black bitumen(IS-158)Ref.Table-I S.No. P1 and F5
Paint with two coat of heat resisting Aluminium paint suitable for temp. above 250 Deg C and upto 600 Deg CRef Table I Sr no F7
Preparation of surface of Towers, columns, vessels, tanks,heat exchangers, piping rotors,impellers,diffusers etc.by sand, ash & grid blasting process and including arrangement of sandash & grid blasting equipment/ tools,tackles labour supervision etc. and by buffing wheel on :
Application of one coat of suitable paint on Towers, column, vessels, tanks, heat exchanger, pipnig and steel structures etc.:
Applicatio of one coat of Synthatic enamel finish paint Ref. Table-ISr.No. F6.
Aplication of one coat of Epoxy finish paints Ref. Table-ISr.No. F1
Application of one coat of Aluminium paint on fencing of single barbed wire up to 2m height Ref Table no-1 Sr No-3
Painting of following transformers with synthetic enamel ready mix grey colour after preparation of surface by rubbing/ scrapping of surface, cleaning of all dust, dirt & other foreign material and application of primer including supply of all types of consumables/ non-consumable materials, tools & tackles as specified in scope of work, General Terms & Conditions of contract, Special Terms & Conditions of contract and applicable Indian Standards & CPWD Specifications of following ratings & capacities at various locations in Plant & Township
132/11 KV,20/26.5 MVA and / or 25/31.5 MVA Power Distribution Transformer including NGR
11/3.3 KV, 10 or 6.3 MVA Power Distribution Transformer including NGR
11KV/415 Volts, 2 MVA/1.6 MVA Power Distribution Transformer
11KV/415Volts, 1000/500 KVA Power Distribution Transformer
Lighting Transformer above 50 KVA & upto 200 KVA
Lighting Transformer upto 50 KVA
E S P Transformers
Painting of following motors with two coat of Epoxy painting after application of epoxy primer and strictly as per job specifications and instructions of Engineer in charge
11KV Motor
3.3KV Motor upto and including 350 KW
3.3 KV Motor above 350 KW upto and including 750 KW
3.3 KV Motor above 750 KW
LT motor upto 1 KW
LT motor above 1 KW but upto and including 3.7 KW
LT motor above 3.7 KW but upto and including 11 KW
LT motor above 11 KW but upto and including 37 KW
LT motor above 37 KW but upto and including 75 KW
LT motor above 75KW but upto and including 125 KW
LT motor above125KW
Painting of folloing motors with synthetic enamel paint after application of primer and strictly as per job specifications and instructions of Engineer in charge
3.3KV Motor upto and including 350 KW
3.3 KV Motor above 350 KW upto and including 750 KW
3.3 KV Motor above 750 KW
LT motor upto 1 KW
LT motor above 1 KW but upto and including 3.7 KW
LT motor above 3.7 KW but upto and including 11 KW
LT motor above 11 KW but upto and including 37 KW
LT motor above 37 KW but upto and including 75 KW
LT motor above 75 KW but upto and including 125 KW
LT motor above125KW
Painting of various sizes of poles of 11KV over head lines, street light, flood light masts with aluminium paint after cleaning and preparation of surface and application of primer strictly as per Scope of work and instructions of Engineer in charge
11KV overhead line rail poles/MS channel box type, flood light masts of height about 30 feet
Steel tubular street light poles of height about 25 feet
Light mast of height above 10 feet & upto15 feet
Light mast of height above 8 feet & upto10 feet
Light mast of height upto & including 8 feet
Railway yard/Coal yard Tower
Painting of PCC pole with water proof cement paint after surface preparation ,cleaning and application of primer strictly as per job specfication and instruction of Engineer In charge
Painting of switch yard/transformer yard, fencing of height upto 2.50 MR with two coats of aluminium paint after aplication of one coat of primer strictly as per job specifications and instruction of Engineer In charge
Painting of ladder type cable trays with one coat of Epoxy primer & 2 coats Epoxy paint
Upto 200 mm width
Above 200 mm and upto 400 mm width
Above 400 mm and upto 600 mm width
Above 600 mm and upto 800 mm width
Above 800 mm and upto 1050 mm width
Above 1050 mm width
For lettering/stenciling
up to 10 meter height of equipments walls
From 10 meter to 20 meter height of equipments/walls
From 20 meter to 30 meter height of equipments/walls
Mandays
Painter
SRI SAI PROTECTIVE COATINGS (BID ID -840873)
ARCOY INDUSTRIES (INDIA) PVT. LTD. (BID ID -840920)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
NITPainting.pdf
Tender Documents • 4.65 MB
BOQ_261553.xls
BOQ • 0.27 MB
NFLBathindaBankdetails.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .