| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L1 | Accepted-Finance Being Lowest | |
| 2 | L2₹31.7 L+₹1.7 L (5.84%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹35.9 L+₹6.0 L (20.1%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹37.4 L+₹7.5 L (25.2%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹39.9 L+₹10.0 L (33.4%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
20 Jan 2020, 6:00 pmClosed
MR ARIZ AHMED
GE U ELECTRIC DELHI CANTT-10
Repair Replacement LT OH line into LT UG cable MCCB pole Box panel painting earthing and connected works at Signal enclave Sanjay Vihar APS coloney CGDA USI AWWA 1 CBPO Static wksp 5 Signal Gp Asmera Line Varuna Naval Mess and associated area in
2019_MES_298653_2
GE ELECT/D-76/2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
7 Feb 2020
9 Jan 2020
22 Jan 2020
10 Jan 2020
20 Jan 2020
15 Jan 2020
Amount
Dismantling/Taking down carefully existing ACSR conductors from 09 Mtr height PCC/Steel Poles incl all connections jumpers insulators,cross arms etc.. etc all as directed by Engineer in charge
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out for laying of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge
S&Laying sub class B bricks having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per Srl item No 6 here in before but using old bricks obtained under item No 1.
Taking down/up existing LT unserviceable cable of any size from trench/pole etc all as specified and directed.
Supply, laying, jointing, testing and commissioning LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete of size 630 Sqmm single core
Supply, laying, jointing, testing and commissioning LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete of size 300 Sqmm 3.5 core.
All as per srl item No 10 here -in-before but size of 3.5 core,185 sqmm.
All as per srl item No 10 here -in-before but size of 3.5 core,95 sqmm.
All as per srl item No 10 here -in-before but size of 3.5 core,120 sqmm.
All as per srl item No 10 here -in-before but size of 3.5 core,50 sqmm.
All as per srl item No 10 here -in-before but size of 3.5 core,35 sqmm.
All as per srl item No 10 here -in-before but size of 4 core,16 sqmm.
All as per srl item No 10 here -in-before but size of 4 core,10 sqmm.
All as per srl item No 10 here -in-before but size of 2 core,25 sqmm.
All as per srl item No 10 here -in-before but size of 2 core,16 sqmm.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade of size 35 to 120 Sqmm x 3.5 core complete all as directed.
All as per srl item No 20 here -in-before but size of 185 -300 Sqmm x 3.5 core
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1.1 KV LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 1.1 KV LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 50mm dia. complete all as specified and directed
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 40mm dia. complete all as specified and directed
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 80 mm dia. complete all as specified and directed
Demolition of PCC from path any position and M&L for PCC in foundation filling and mass concrete type C2 (1:4:8) using 40 mm grded stone aggregate for foundation of pole complete all as specified
Demolition of PCC from path any position and M& L for PCC type B1 (1:2:4) using 20 mm graded aggregate for pedestal of poles including use and waste of formwork complete all as specified
Supply and fix PVC insulated copper cable Three core of size 2.5 sqmm
M&L for regid non metallic PVC conduit of size 20 mm dia fixed to pole including all fitting accessories such as clamp, shaddles, nut, bolts, washer etc.
Supply and fixing KIOSK box weather proof made out of PVC make : Sintax or equivalent in universal made out of one piece mounted SMC base and door, pole mounted hinged door size 333 mm x 23mmx120 mm outside and 300 mm x 200mmx105 mm inside dimensions with top hung shutter comprising of aluminium bus bar 4 strips 3 phase and neutral 63 Amps and one 6 Amps MCB SP for control the light fitting including two numbers F1 clamps 30x4 mm with necessary MS nut,bolt and washer including embossing/painting convention skull and bones in red signal colour on front face of KISOK box.
Supply, installation, testing and commissioning in replacement (Including dismantling existing panel)LT panel board 415 volts, AC 3 phase, 50 Hz, factory made outdoor type, vermis proof made up of 3.15mm and cubical component 2 mm CRCA sheet, MS angle iron 50x50x6 mm base, cable entry from bottom conforming to degree of protection IP-65 . Gasketing ensuring IP protection, with powder coating and locking arrangements, LT panel mounted on PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) to cover the entire area of panel board, 15 cm deep in ground and 5 cm above ground minimum, with cable alloys. The LT panel shall be seprate chamber for bus bar, switch gear and cable entry/end connection duly prewired with proper spacing to accommodate to all accessories, cable connection with suitable size of cable glands, lugs/thimbles comprising of the followings :- (a) Aluminium bus bar 3 phase and neutral 600 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. Including connection existing cable 630 sqmm single phase with lugd etc( as incomming). (b) MCCB, 04 Pole, 400 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 01 No, (outgoing). (c )MCCB, 04 Pole, 160 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 04 No, (outgoing) (d) MCCB, 04 Pole, 100 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 01 No, (Out going) (e) Indication lamps R,Y,B LED type with 3 Nos of 5 A MCB SP – 1 set. (f) Multifunction meter with communication ports RS 485/232, 5 display, class-1. NOTE : All MCCBs should have Icu=Ics= 100% ..
Supply, installation, testing and commissioning in replacement (Including dismantling existing panel)LT panel board 415 volts, AC 3 phase, 50 Hz, factory made outdoor type, vermis proof made up of 3.15mm and cubical component 2 mm CRCA sheet, MS angle iron 50x50x6 mm base, cable entry from bottom conforming to degree of protection IP-65 . Gasketing ensuring IP protection, with powder coating and locking arrangements, LT panel mounted on PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) to cover the entire area of panel board, 15 cm deep in ground and 5 cm above ground minimum, with cable alloys. The panel should provision for cable entry/end connection duly prewired with proper spacing to accommodate to all accessories, cable connection with suitable size of cable glands, lugs/thimbles comprising of the followings :- (a) Aluminium bus bar 3 phase and neutral 600 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) MCCB, 04 Pole, 400 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 01 No, (Incoming). (c )MCCB, 04 Pole, 160 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 02 No, (outgoing) (d) MCCB, 04 Pole, 125 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 02 No, (Out going). (e) MCB SPN 40 Amps 230 volts - 02 Nos. (f) MCB 63 Amps SPN 230 volts - 02 Nos. (g) Indication lamps R,Y,B LED type with 3 Nos of 5 A MCB SP – 1 set. NOTE : All MCCBs should have Icu=Ics= 100% ..
Supply, installation, testing and commissioning LT feeder piller box/panel board 415 volts, AC 3 phase, 50 Hz, factory made outdoor type, vermis proof made up of 3.15mm and cubical component 2 mm CRCA sheet, MS angle iron 50x50x6 mm base, cable entry from bottom conforming to degree of protection IP-65 . Gasketing ensuring IP protection, with powder coating and locking arrangements, LT panel mounted on PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) to cover the entire area of panel board, 15 cm deep in ground and 5 cm above ground minimum, with cable alloys. The panel should provision for cable entry/end connection duly prewired with proper spacing to accommodate to all accessories, cable connection with suitable size of cable glands, lugs/thimbles comprising of the followings :- (a) Aluminium bus bar 3 phase and neutral 200 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) MCCB, 04 Pole, 160 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 01 No, (Incoming). (c ) MCB, 04 Pole, 40 Amps, with breaking capacity 16 KA at 415 volts - 02 No, (outgoing) (d) MCB SPN 40 Amps 230 volts - 06 Nos. (e) MCB SPN63 Amps 230 volts - 06 Nos. (f) Indication lamps R,Y,B LED type with 3 Nos of 5 A MCB SP – 1 set.
M&L for painting on old surfaces LT panel of size 2 to 4 Sqm by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint (light gray) shade No-631 to achieve good finish by applying two coats of paints by spray painting machine crefully after disconnection of power supply and covering the meters, indicators and switches to prevent from fall of paint drop on them and including writing number, letter etc with white paint on newly painted surfaces
Ditto all as per item No 34 above but of size 5 to 10 Sqm.
Disconnecting the existing unserveceable/burnt MCCB from the cable taking out from panel board & supply & fix new MCCB,3pole 400 Amp 35 KA breaking capacity Adjustable type suitable for 415 volts,50HZ 3 Phase supply thermal magnetic release, fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB andconnecting with existing cable including thimble,nut bolt and washers etc complete.
All as per item No 36 above but MCCB of rating 250 Amp 25 KA breaking capacity 3 pole
All as per item No 36 above but MCCB of rating 200 Amp 25 KA breaking capacity 3 pole
All as per item No 36 above but MCCB of rating 100 Amp 25 KA breaking capacity 3 pole
Material and labour earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 2.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm by means of electric arc welding of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point and the equipment to be earthed all as specified including testing and commissioning complete all as directed at site.
Vijay Electricals
M/s KUNDU CONSTRUCTION
MV Engineers And Contractors
A R construction
Ridhi engineers and builders
DHARYA ENTERPRISES
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .