Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.8 L+₹71,870 (2.76%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
28 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major A R Thakkar
GE (P) Dappar
Repair/Maintenance of LT distribution system at Adm/ domestic area at Mil Stn Dappar under GE (P) Dappar
2022_MES_549323_1
GE (P) DPR-14/2022-23
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹76,000
Yes
16 Dec 2022
1 Sept 2022
30 Sept 2022
1 Sept 2022
28 Sept 2022
12 Sept 2022
1 Sept 2022 - 12 Sept 2022
Amount
Disconnecting & taking out old unserviceable LT cable of any size.
Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 120 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 95 sqmm 3.5 core.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 70 sqmm 3.5 core.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 50 sqmm 3.5 core.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 35 sqmm 3.5 core.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 25 sqmm 4 core.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 16 sqmm 4 core.
Description all as per ser item No 2 here-in-before but size of LT under ground cable 10 sqmm 2 core.
Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge.
Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm.
Make bore to road width for providing GI pipe medium/light grade both end socketed for passing armoured cable complete all as specifed.
Material and labour for galvanized iron tubing size 50 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed. Make:- Jindal. Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for galvanized iron tubing size 40 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed. Make:- Jindal. Complete all as specified and as directed by Engineer-in-Charge.
M & L for earthing with galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth earth strip 32x6mm soldered & riveted toearth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutral or test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia 'Light grade' 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engr-in-Charge.
M & L earth continuity conductor GI of 32x6 mm of GI strip by means of bolts, nuts, check nuts and GI washers complete all as specified.
M & L Synthetic insulating mat (rubber matting), ISI Marked suitable for 1100 Volts electrical grade 2mX1mX2mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed.
M&L for Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20x15cm size.
M&L for application of two coats of aluminium paint on steel tubular/rail pole of 9/11/13/15 M long externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in blackbase & white letters paint and incld. painting five no. strips upto 30 cm on bottom of pole with black and yellow colour paint alternately all as specified and directed by Engr-in-Charge.
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 70 to 120 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 150 to 185 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 240 to 300 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB FP, 36kA, 400 AMPS with Thermal - Magnetic Release Type Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 1.5 - 8 x In, Make - L&T, Cat No. - CM98403OOROOG including spreader terminals (Make-L&T, Cat No.-ST98066OOOO). NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel.
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25kA, 250 AMPS with Thermal - Magnetic Release Type, Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OOPO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OONO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO)/Schneider or equivalent
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OOMO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 125 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OOLO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO)/ Schneider or equivalent
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, /Schneider or equivalent
Supply only fuse wire (Tin & Copper) 16/18/20 SWG complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable ACSR conductor and supply and fixing aluminium conductor steel reinforced any type complete all as specified and as directed by Engr-in-Charge.
Restringing and Fixing ACSR Conductor reinforced of any size to proper sag incl binding on insulator all as specified and as directed by Engr-in-Charge
Cutting & trimming of tree branches any girth and size around overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 40 mtrs span gap of HT/LT lines including clearing the site all as specified and directed by the Engr-in-Charge.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer including removing old unserviceable rusted ones complete all as directed by Engineer-in-Charge
M&L for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc complete all as specified & directed with diameter of stay 20 mm of stay rod complete all as specified & directed. Note: - Loop type insulator, PCC foundation, Exc & earth work & GI stay strand will be measured and paid seperately under relevent items of Sch 'A'
Supply and replace existing u/s indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and directed.
S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply
S&F in replacement Street light control junction box 280x170x130mm upto 16 sq mm 4 core cables made out of FRP sheet moulded and arrangement of incoming 3 phase 4 wire system and out going 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 2.5 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable to pole of any size including bolts nuts & washers.”NOTE: - The rates includes incoming & outgoing cables glands & lugs of size up to 16 sq mm 4 core.
M&L for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of factory fabricated of size as per the existing IEC 60439 Part 1 norms, floor mounted, IP 55 grade, outdoor type double door type LT cubical panel made out of CRCA MS sheet duly powder coated Form 4a type with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted on PCC (1:4:8) type D2 of size on as per the panel dimensions such that there should be 600 mm offsets all around th panel complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with CRCA sheets at all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :-
(i) MCCB 320 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM94105OOQ1OG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
(ii) MCCB 160 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOMO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
(iii) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOKOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - OUTGOING
(iv) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 05 Nos. - OUTGOING
(v) LED indicators - R/Y/B 240 V AC - 15 Nos per Incoming & outgoing MCCBs
(vi) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
(vii) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
(Viii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
(ix) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 03 Nos.
(x) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
M&L for dismantling, disconnecting connected cables of old unserviceable LT FPB, supplying, installing, testing and commissioning of factory fabricated CPRI approved, floor mounted, IP 55 grade, outdoor type LT cubical panel made out of 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 of size not less than LBW-0.60mX0.60mX0.40m, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 with 200 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :-
(i) MCCB 63 Amps ,415 V TP pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG-01 including spreader terminals set of 04 direct rotary handle -01Nos or equivalent in legrand/ABB/Schenider
(ii) LED indicator - R/Y/B 240 V AC - 18 Nos. per incoming and outgoing MCCBs.
(iii) Analogue Voltmeter having voltage of range : 0-500 V, MAKE - Legrand, CAT No. - 0046 60.
(v) Analogue Ammeter having AC range : 0 - 30 A (4 modules) with suitable size resin cast ring type CT-03 Nos. MAKE - Legrand, CAT No. - 0046 02.
All as per SL Item No. 48 above but panel with following components -
(i) MCCB 160 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOMO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
(ii) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOKOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 Nos. - OUTGOING
(iii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 05 No. - OUTGOING
(iv) LED indicators - R/Y/B 240 V AC - 03 Nos per Incoming .
(v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (for Incoming)
(vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
(vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
(viii) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 03 Nos.
(ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
Supply and fix in replacement after taking out the old one 7 mtr long pole decorative type with pole bottom of CI emblishment of dia 150mm .Pole should be PU painted finish( colour as approved by engr-in-charge) mild steel as per IS1161-pole paint having plasma cut & duly chamfered opening window of made up of size not less than 300 X 110 mm for terminal connections and mounting accessories with window cover fitted with allen screws to the elliptical poles of 41 X 90mm on 230mm PCD .The pole must be fitted with a base plate of 290 mm dia.Quoted rate is deemed to be inclusive of cost of minimum 04 nos of M12 bolts 20 X 60 mm. Quoted rate is also deemed to be inclusive of cost of decorative bracket having arm length of 1 mtr with PU painted finish. Total weight of pole should not be less than 120 kg. The bracket to be fixed should be fixed on the top of 7 mtr long pole .The height of pole should be 7 mtr from bottom to top without decorative bracket.
Supply and fix in replacement after taking out the old defective light classic look metal sheet housing with sealed clear acrylic cover LED fitting of 60 watt having dimensions as length not less than 516+- 5mm and width not less th +- 5mm IP 66with integrated constant current electronic driver having operating voltage range 120V -280Vwith APFC (SMPS based constant current supply),lower THD , Open circuit protection,over coltage protection,surge voltage protection > 4kV having SMD LED array technology having> 50000 burning hours,3000K (warm white),CRI>70 all as specified and directed by engr-in-charge. Make:- HPL Cat part no. HPLLEDDECSL008030B or equivalent
Material & Labour for cement concrete 1:4:8 type D- 2 using 40mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly complete all as specified and directed by Engr-in-Charge.
Material & Labour for cement concrete 1:2:4 type B - 1 using 20mm graded crushed stone aggregate in coping pedestal to poles including provision of necessary frame work finishing the expossed surface even and smooth complete all as specified and directed by Engr-in-Charge.
Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified abd specified.
S&F in repairs 1.1 KV current transformer of ratio 150/5 complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 1.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 6 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 1.5 sqmm pin type lugs complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 6 sqmm pin/fork/round type lugsr complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 6-32 A SP MCB, 10 kA 'C' series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 32 A TP MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 63A TPN MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
Dismantling of unserviceable insulator any type and any size.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade.
S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator having working pressure 1100 Volts, height 75mm and dia 90mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts.
Laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 95 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.(d) The XLPE Cable is issued under sch B
Laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 25/16 sqmm x 4 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.(d) The XLPE Cable is issued under sch B
Laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 50 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.(d) The XLPE Cable is issued under sch B
Laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 240 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.(d) The XLPE Cable is issued under sch B
Fixing only for 7 mtr pole decorative type pole bottom dia 150mm with CI emblishment and with and including decorative single bracket.Pole is painted with PU painted finish( colour as approved by engr-in-charge) mild steel as per IS1161-pole height 7 mtr having plasma cut & duly chamfered opening window of size not less than 300 X 110 mmfor terminal connections and mounting accessories with window cover fitted with allen screws to the elliptical poles of 41 X 90mm on 230mm PCD suitable for M!2 bolts 20 X 600mm inclusive of mild steel base plate of dia 290mm with single arm decorative bracket pf 1 mtr-MS pU painted pole- total weight of pole should be min 120Kg-.Make: Apollo/jindal Cat part No.- JPCD7M1DAB .Note:- (i) PCC work will be measured and paid separately. (ii) Poles will be issued uner schedule B
HARISH SALES CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .