Electrical License: The tenderer/Firm should have valid electrical contractor license on their own name or firm name issued by Electrical licensing board of any state. The license should have been issued on a date prior to the date of tender opening. Copy of License shall be uploaded online failing which offer will be rejected.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month before the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar nature of work: "Works of wiring/cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements, earthing etc. (with or without supply of items / equipment) for 230V, 1phase or 415V, 3phase system or higher voltages".
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-F, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
9 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer /s are required to submit a scanned / attested copy of following information along with their tender- 1. Bank Account No 2. Name of Bank 3. Indian Financial System Code {IFSC} 4.PAN No 5. Tenderers Contact No Contractor should provide firms PAN, issued by Income Tax Department with his quote or within30 {Thirty} days of award of contract. No payment will be released without submission of PAN. All taxes including surcharge and cess shall be recovered from his payment as per tax provisions in vogue.
The tenderer shall thoroughly go through the entire tender document and strictly adhere the instructions and directions given at different pages.
It is responsibility of the tenderer that they ensure to see any corrigendum of the tender to check the corrigendum on the website from time to time.
All the required/supporting documents should be scanned and uploaded.
In case the date of closing mentioned in the Notice Inviting Tender is declared a holiday/bandh/strike etc. on any account, the date of closing tender online will not be changed as the application in the website of IREPS does not permit submission of any offer after closing date and time of the tender. However, opening of tenders online will be on any convenient day after the closing date/time of tenders.
Opening of e-tender online:- The e-tenders will be opened online using the IREPS portal. No representative is required to be present for opening of tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders in the website after the opening of the tender.
Nanded Division -Provision of Ballast Less Track and Quick Watering System at Adilabad station - Electrical Arrangements.
NED-E-43-2025-26~SCR
NED-E-43-2025-26
Open
Works - General
12 Months
Nanded, Maharashtra
₹0
₹2.4 L
12 Feb 2026
20 Jan 2026
29 Jan 2026
178 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,47,47,367 | ||
| — | 1.00 | — | — | ||
| Supply, installation, testing and comissioning of Pump sets of 60 HP/45KH (1 set=3 no's) each along with IE 3 Electric Motor). Motor & Pump should be of standard manufacturer such as M/s Kirloskar or similar Positive suction and discharge capacity of 320 m3/hr. with minimum 35 meterhead. | — | — | — | 8,12,634 | |
| — | 1.00 | — | — | ||
| Supply, fixing and installation of Common Skid Mounting For Pump set | — | — | — | 84,028 | |
| — | 1.00 | — | — | ||
| Supply, fabrication and erection of MS Fabricated Suction manifold of 500 mms suitable for 3 no's of 60 hp pump sets for quick watering facility including fitment work. | — | — | — | 1,06,140 | |
| — | 1.00 | — | — | ||
| Supply, fabrication and erection of MS Fabricated Delivery manifold of 500 mm suitable for 3 no's of 60 hp pumpsets for quick watering facility including fitment work as per applicable standard IS specifications. | — | — | — | 1,06,141 | |
| — | 3.00 | — | — | ||
| Supply, installation , testing and commissioning of 200 mm Basket type in line Strainer for pump sets. Make: ZOLOTO/AUDCO/L&T/NVR | — | — | — | 2,19,618 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of Non return valve 150 mm. Make:ZOLOTO/AUDCO/L&T/NVR | — | — | — | 40,887 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of On Line Flow meter 400 NB Make: ABB/E&H/Emmeson | — | — | — | 4,86,475 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of On Line Flow meter 200 NB Make:ABB/E&H/Emmeson | — | — | — | 9,28,725 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of Electrical Operated solenoid Valve 400 mm with CI bolt, SS304 Disc Make: Sude Engg/Maarck/KOR India | — | — | — | 4,86,475 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of Electrical Operated solenoid Valve 200 mm with CI bolt, SS304 Disc Make: Sude Engg/Maarck/KOR India | — | — | — | 9,28,725 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Suction Pressure Transducer and Pressure Gauges With Fittings | — | — | — | 27,711 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing andcommissioning of Delivery PressureTransducer and Pressure Gauges With Fittings | — | — | — | 27,711 | |
| — | 1000.00 | — | — | ||
| Supply and running of of 1.5 sq.mm 6core copper cable for controls of flow meter and Auto Valves. | — | — | — | 1,10,000 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of Hydro Pneumatic Tank With Fittings | — | — | — | 54,768 | |
| — | 1.00 | — | — | ||
| Design, install, testing and commissioning of SCADA for 500 Tab data analysis including of desk top PC,LED display 32"" Keyboard, printer and licensed viewing system for Two integrated remote installed office PCs through team viewer through internet connection and allied accessories complete all as specified and as directed for controlling pumps and all electrical operated values. | — | — | — | 4,57,324 | |
| — | 1.00 | — | — | ||
| Supply, installation and commissioning of 2 KVA UPS with back up of minimum 2 hr. | — | — | — | 1,53,947 | |
| — | 4.00 | — | — | ||
| Supply, erection, testing and commissioning of all material,excavation, and casting of cement concrete foundation/ concreting in ratio 1:3:6. | — | — | — | 23,384 | |
| — | 1.00 | — | — | ||
| Supply, transportion, installation, testing and commissioning of 250 KVA DG set 3 phase with AFM control panel with CPCB -IV + compliance and Specification as per model No : M250DR of mahendra powerol or its equivalent | — | — | — | 31,46,666 | |
| — | 150.00 | — | — | ||
| "Supply, running and connecting of 4 core 16 sq.mm. PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS694 : 2010 or its latest amendment." | — | — | — | 1,61,850 | |
| — | 1.00 | — | — | ||
| Control panel with inclusion of the following (i) Design, fabrication,transportation, supply, erection and commissioning of LT cubical panel 3 phase and neutral 415 V, 4 wire,free standing floor mounted, LT panel made up of 14 SWG CRCA(Cold rolled Carbon Annealed) sheet after seven tank process and painting with EPOXY powder coating. TPN (Triple Pole Neutral) tinned copper bus bar supported with DMC/AMC barriers and colour coded with heat shrinkable sleeves.The metering shall be provided as specified. The panel shall have short circuit with standing capacity of minimum 50 KA (RMS)power frequency test and consist of the switch gear as mentioned below.The panel shall be mounted on channels including supply and fixing as per specification. The complete work has to be carried out by the contractor including masonry work after execution, all the feeder cables have to be connected to new panel with suitable cable hands as per the requirement of the Engineer at site.Air condition provision is to be made for entire control panel. Control panel should have microprocessor type PLC based with dedicated VFD for each pump( 60 HP capacity) for automatic Smart control panel SCADA enabled suitable for operation of system. The control panel will have protection like-over/under voltage, dry run protection, over/under current,phase reversal protection, single phasing protection.The control panel should be having remote monitoring/control system for operation and observation both through GSM/WIFI based communication. The control panel should be programmed in such a manner so that the VFD can operate upto 110% of total load condition if at any point of time on a multiple pressure variation water flow required. The contol panel shall have cascade bypass operation due to failure of drive the pump will operate on direct mode. HMI touch screen display will be on the control panel body for operation. All MCCB's will be microprocessor based The panel should consist of Incomer 400A Change over switch, 400 A microprocessor based MCCB with 50KA Icu=Ics= 100%, 3 no's VFD with3 no's 100A MCCBs with tinned busbar of 800A ( RYBN) as per as perIS 613: 2000 or latest amendment,Program logic controller, HMI and 60KVAr APFC bank with IP 43 protection with appropriate DMC /SMC barriers and colour coded with heat shrinkable sleeves, LT 3 Phase Digital Multi function energy meter with 3 lines LCD display for measuring all the parameters(Voltage/ Current/Power/Frequency/power factor/kw/kwh/ kvar/kvarh) , Current T/Fs, indication lamps for incoming& outgoing feeders. Support insulators, neutral links, Incoming & outgoing terminals, suitable cable termination glands , grommets,lugs, connecting wires and all other accessories suit with the following switchgear and accessories. The cables should be properly terminated in the switchgears with necessary lugs and all necessary accessories complete. The panel should conform to IS/IEC 61439 inall respects. The LT Control panel should manufactured by CPRI approved manufacturers only. | — | — | — | 10,58,206 | |
| — | 1.00 | — | — | ||
| Fabrication and erection of 14 SWG CRCA sheet steel enclosure of suitable size for outdoor distribution Panel with IP 54 protection, plinth mounted with Double Door, including cutting, bending drilling, welding and revetting etc, complete with cleaning with 7 tank process and painting with EPOXY powder coating including cost and conveyance of all materials and labour charges. The MDBs shall be mounted on suitable required size of CC plinth (CC plinth cost will be paid separately)/ wall mounted and secured with bolts, nuts and washers as advised by Engineer at site. The panel comprising of 1600A tinned Copper Bus Bar RYB & N of same size) as per IS 613: 2000 or latest amendment required shape supported with appropriate DMC / SMC barriers and colour coded with heat shrinkable sleeves, LT 3 Phase Digital Multifunction energy meter with 3 lines LCD display for measuring all the parameters( Voltage/ Current/ Power/Frequency/power factor /kw/kwh/ kvar/kvarh) , Current T/Fs, indication lamps for incoming & outgoing feeders. support insulators, neutral links, Incoming & outgoing terminals, suitable cable termination glands , grommets, lugs, connecting wires and all other accessories with the following switchgear and accessories. Suitable busbars has to provided for the incomings of all the MCCB's from main bus barThe cables should be properly terminated in the switchgears with necessary lugs and all necessary accessories complete. The panel should conform to IS/IEC 61439or its amendment in all respects. The panel should comprise of the following Switchgear: 1.Supply and installation of ACB 800 Amps 36KA-2 nos, 2. Supply and installation of on load change over switch of 800A of conforms to IS/IEC:60947-3 or its latest amendments -1 nos, 3.Supply and installation of microprocessor based release; Icu =50KA ; 400A 4 Pole MCCB conform to IEC 60947-2 or latest amendments communication capable for energy management with spreader links (2 sets), phase barriers-2 nos, 4. Supply and installation of 320 A 4P MCCB, 36 KA, Micro processor based adjustable with LSIG protection communication capable conform to IEC 60947-2 or it's equivalent with extended ROM, spreader links(2 sets)-2 nos. 5. Supply and installation of 250 A4P MCCB, 36 KA, Microprocessor based adjustable with LSIG protection communication capable conform to IEC-60947 -2 or its latest amendments model no 4205 39 of legrand make or its quivalent with extended ROM, spreader links (2 sets)-2 nos, 6. Supply and installation of DPX3 160 thermal magnetic based release; Icu = 36KA; 100A 4 Pole MCCB conform to IEC 60947 - 2 or its latest amendments of model no. 4200 95 of legrand make or equivalent make with extended ROM, spreader links (2 sets)-4 no. 7. Supply and installation of DPX3 160 thermal magnetic based release; Icu=36K; 63A 4 Pole MCCB conform to IEC 60947-2 OR ITS LATEST AMENDMENT OF MODEL NO. 4200 93 OF LEGRAND MAKE OR IT'S EQUIVALENT WITH EXTENDED rom, spreaser links (2 sets) -4 nos, 8. Supply and fixing of 40/50/63A A 4P MCB C Curve, 10 KA capacity with necessary connections and all accessories complete-2 nos, 9. Supply and erection of LT 3 phase Digital Multifunction energy meter with 3 lines LCD Display for measuring all the parameters ( Voltage/Current/Power/Frequency/power factor/kw/kwh/kvar/kvarh) on existing box panel board- 14 sets of 3 nos. The LT control panel should manufactured by CPRI approved manufactures only. | — | — | — | 9,04,673 | |
| — | 2.00 | — | — | ||
| Supply, Fixing, & Installation Of Open well submersible Pumps. The pump shall be of 20 hp 3 Phase 380 V with head range of 9 to 31 MTRS and flow range of 46 to 27 LPS.Pump Material of construction will be as follows: - Pump casing - SS304, pump impeller - SS 30 , Shaft -Duplex Steel . Make- Shakti,Crompton, Texmo or similar. | — | — | — | 2,25,238 | |
| — | 1.00 | — | — | ||
| Supply, Fixing, & Installation Of Fixed Speed smart starter for 20 hp pump (1w+1S) With Auto Cascading, Over voltage,under voltage, over load, dry run & other necessary protection. The starter will have gsm communication. | — | — | — | 1,12,619 | |
| — | 12.00 | — | — | ||
| Supply, fixing and Installation of 200 mm M.S Pipe with painting | — | — | — | 68,880 | |
| — | 6.00 | — | — | ||
| Supply, fixing and Installation of 400 mm M.S Pipe with painting | — | — | — | 53,232 | |
| — | 9.00 | — | — | ||
| Supply, fixing and installation of MS bends 200 mm | — | — | — | 26,298 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing and commisioning of Butter Fly Valve 200 mm. | — | — | — | 1,37,259 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of Butter Fly Valve 400 mm with gear and handle | — | — | — | 60,588 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of 200 mm MS Flanges as per standard or exact suit to pipes and fittings | — | — | — | 49,600 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of Set of Rubber gasket+ Nuts and bolts for 200 mm Flanges | — | — | — | 28,700 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of 400 mm MS Flanges as per standard or exact suit to pipes and fittings. | — | — | — | 37,572 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of Set of Rubber gasket+ Nuts and bolts for 400 mm Flanges. | — | — | — | 17,532 | |
| — | 250.00 | — | — | ||
| Supply, fixing/connecting of MS/GI/Fabricated Spacers like, Tee, Enlarger, reducer & spool pieces | — | — | — | 84,750 | |
| — | 1.00 | — | — | ||
| Supply of one computer tabel, two chairs and one small cup board | — | — | — | 30,789 | |
| — | 10.00 | — | — | ||
| Supply and fixing of 20 W LED Tube Light fittings conforming to specification Make: Havells/Syska /Crompton /Bajaj/Surya. | — | — | — | 3,660 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 28W 1200 mm BLDC Ceiling Fan, BEE 5 star rated with remote control and all connected accessories conforming to class 1 of IS:374/1979 with amdts1 to 6 including lobor charges. Make:Atomberg /Havells / CG/Bajaj/Orient. | — | — | — | 4,694 | |
| — | 4.00 | — | — | ||
| Supply and fixing of Ventilating Fans(Exhaust fan) of 4 pole 300 mm sweep size with metalic body with capacitor conforming to IS No.2312/67 (Reaffirmed 2005) complete with louver and all connected accessories. Make: Havells/CG/Bajaj/Khaitan. | — | — | — | 8,584 | |
| — | 16.00 | — | — | ||
| Provision of concealed wiring with two runs of 1.5 Sq,mm 1100 Volts and one run of flexible copper conductor 1.5 Sq,mm 1100 Volts FRLS PVC insulated wires ISI marked (Phase, neutral and earth)(upto 10 meters) in the PVC conduit pipe with 6A flush modular type switch including 2 way switches where ever required, ceiling rose, bulb holder and modular type plate cover to MS switch control box including all labour charges complete for light points, ceiling fans and exhaust fans points cat walk points and ioh service buidling points etc. accessories. | — | — | — | 11,888 | |
| — | 150.00 | — | — | ||
| Supply and run of 2 nos, 2.5 sq mm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of 1.5 sq mm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit Pipe conforming to IS 1554-part 1. | — | — | — | 16,950 | |
| — | 80.00 | — | — | ||
| Supply and run of 2 nos, 4.0 sq mm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of 2.5 sq mm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit pipe conforming to IS 1554-part | — | — | — | 13,600 | |
| — | 40.00 | — | — | ||
| Supply and run of 2 nos, 6.0 sq mm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of 2.5 sq mm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit/Casing and capping pipe. | — | — | — | 8,000 | |
| — | 220.00 | — | — | ||
| Supply and concealed laying of 25 mm dia 2 mm thick PVC pipe (ISI MARK) heavy mechanical stress FRLS with all required accessories including masonary work (chipping etc.) and labour charges etc. | — | — | — | 9,020 | |
| — | 4.00 | — | — | ||
| Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. Make: Legrand/Havells/ Schneider/GM/INDOASIAN . | — | — | — | 1,152 | |
| — | 10.00 | — | — | ||
| Supply and erection of modular type 5 pin 6A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. Make: Legrand/Havells/GM/INDOASIAN. | — | — | — | 1,210 | |
| — | 10.00 | — | — | ||
| Supply and erection modular type switch 6/10A ISI mark approved make duly erectedon provided plate and box with wiring connections complete. Make:Legrand/Havells/GM /INDOASIAN. | — | — | — | 470 | |
| — | 1.00 | — | — | ||
| Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 10 ways for outgoing SP MCB's on iron frame/laminated board as per specification No. SW-SWR/MCBDB Make: Legrand/Havells/L&T. | — | — | — | 1,528 | |
| — | 2.00 | — | — | ||
| Supply, erection and marking DP MCB 16-32A, 10 kA B/C-series in provided distribution board as per specification No. SW-SWR/MCB Make: Legrand /Havells/L&T | — | — | — | 964 | |
| — | 4.00 | — | — | ||
| Supply, erection and marking SP MCB 16-32A, 10 kA B-series in provided distribution board as per specification No. SW-SWR/MCBMake: Legrand /Havells/L&T | — | — | — | 720 | |
| — | 6.00 | — | — | ||
| Supply and erection of earth electrode as per the enclosed specification. | — | — | — | 21,444 | |
| — | 1200.00 | — | — | ||
| Supply and running of 8 SWG GI wire is to be laid for earth continuity. | — | — | — | 13,200 | |
| — | 1.00 | — | — | ||
| Supply and fixing of 30W 400 mm BLDC Wall Mounting Fan,Energy Efficient with remote control and all connected accessories conforming to class 1 of IS: 555/1979 with Amdts. including laborcharges. Make: Gorilla/Havells/CG/Bajaj/Usha. | — | — | — | 3,290 | |
| — | 1.00 | — | — | ||
| Supply, fixing and connecting of 2 pole 2 module 32A 30 mA Lexic RCBOs conforming to IEC 61009-2-1 as advised by the site supervisor with all necessary accessories complete or equivalent make. | — | — | — | 5,414 | |
| — | 6.00 | — | — | ||
| Supply and fixing of 40 W LED type weather proof street light fitting complete with all accessories and conforming to specification no. Make: Bajaj/Havells/ Philips. | — | — | — | 15,096 | |
| — | 2.00 | — | — | ||
| Supplying and erecting triple pole and neutral distribution board (TPNDB) with door surface/flush mounted with 4 ways for incoming and 12 ways for outgoing SP/TP MCB's on iron frame/laminated board as per specification No. SW-SWR/MCB DB with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner Make: Legrand/Havells/L&T. | — | — | — | 5,024 | |
| — | 2.00 | — | — | ||
| Supply, erection and marking TPN MCB 63A, 10 kA C-series in provided distribution board as per specification No. SW-SWR/MCB Make: Legrand/ Havells/L&T. | — | — | — | 2,792 | |
| — | 2.00 | — | — | ||
| Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. Make: Legrand/Havells/ Schneider/GM/INDOASIAN | — | — | — | 970 | |
| — | 100.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | 6.00 | — | — | ||
| — | 10.00 | — | — | ||
| — | 400.00 | — | — | ||
| — | 300.00 | — | — | ||
| — | 1200.00 | — | — | ||
| — | 1200.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureFrevised.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .