Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC INDIRA HATIA BIRBHUM | BIRBHUM | WEST BENGAL | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹14.6 L+₹16,430 (1.14%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹15.3 L+₹86,675 (6.02%)Rejected-Finance 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹15.5 L+₹1.1 L (7.70%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L4 | Rejected-Finance 4th lowest | |
| 5 | L5₹15.7 L+₹1.3 L (9.13%)Rejected-Finance | L5 | Rejected-Finance 5th lowest |
Tender Value
Refer Docs
EMD Value
₹29,004
Closing Date
19 Oct 2022, 12:30 pmClosed
EE/BKED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Electrical Installation Work at Paribahan Bhaban, Bankura including AC, DG, Glow Sign Board and lift_ External E.I work for SITC of LED Glow Sign Board, UV water cooler, LC, DG at Parribahan Bhaban, Bankura.
2022_WBPWD_412621_1
WBPWDTE/EE/BED/NIQ_93/Q of 2022-23
Open Tender
MISC ELECTRICAL WORKS
Item Wise
45 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹29,004
22 Nov 2022
29 Sept 2022
21 Oct 2022
29 Sept 2022
19 Oct 2022
29 Sept 2022
Amount
S&F Lighting conductor Air- terminals made of 15 mm. dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia.6 mm. thick base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC motar(4:2:1)
S&F of 4 SWG GI (Hot Dip) wire on Parapet/Roof/Plinth/ Surface of wall for lighting conductor as required(Horizental runs) 40 mm.long GI Stapes space not exceeding 1300 mm. to GS.(J-1,It.-2)
S&F of 4 SWG GI (Hot Dip) wire on wall for lighting conductor as required(Vertical runs) with 40 mm.long GI Stapes space not exceeding 1 mt. to GS.(J-1,It.-3)
Cutting comices/steps etc incluiding cutting recess in the buildings etc. & supply & fixing 15 mm. bore (ISI- Medium)GI pipe protection as and mending good the damages to the building works: a)Length up to 0.5 mt
b)Length above 0.5 mt
Making soldered joints beteen conductors and down pipes/ orther metalic object (J-1, it-6)
Supply, Installation ,Testing and Commissionning of silent type 62.5 KVA DG set confirming to CPCB -II norms as per the following specification. A) Diesel Engine : Liquid Cooled Diesel Engine, devloping 1500rpm having blower fan of adequate capacity, fanguard, fan belts etc. the Diesel Engine shall be vertical, Electric start, compression ignition, 4 stoke, continuous run at 1500 rpm conforming to IS 10002, ISO-3046, BS 5514 standard with an permissible over load capacity of 10% for one hour in 12 hour in every 12 hrs. of operation complying present CPCB norms: B) Alternator: make Alternator suitable to deliver rated output of 62.5KVA at 1500 rpm, 415V, 0.8 PF(lag), 50 HZ, 3 phase,in SPDP enclosure, self excited & self regulated, brushless. The Alternator should be IS: 4722/BS EN 60034-1 & & will be suitable for tropical condition having full load efficiency above 90%. Class of insulation shall be H, and encloser shall be IP23. C) Gen set Controller : i)Having indication/LCD display for lub oil pressure, battery voltage, engine rpm, fuel level in the dry tank, engine running hrs. indication, AC current, AC Voltage, AC frequency, AC power metering with suitable CTs for dispalying the electrical parameters. ii) Safety Alarms for High engine temperature, low lub oil pressure, low raditor water level, low fuel level, battery high voltage, under/over speed alongwith safety trips for High Engine temperature, low lube oil. D) With AMF control Panel suitable for 62.5KVA DG Set. E) Base frame, F) Fuel Tank having atleast 8 hrs capacity for 03 (three) Shifts, G) 12 Volt battery with leads, E) Canopy. Make:Kirlosker Green /Jackson Cummins/Ashok leyland/Mahindra /Greevs N.B. 1) Rate should be cotated inclusive of all taxes, duties, installation, Testing and commissioning charge (if any) at site). 2) The DG set is to be delivered at site free of cost. 3) Necessary warranty certificate, Testing and Commissioning report are to be submitted duly counter signed by the concern SAE/AE. 4) Necessary Connecting cable req. in between AMF panel & DG set-5 Mtrs. to be supplied free of cost. 5) A deceleration from engine manufacturer about no engine power direction upto 50C ambient temp. should be uploaded during e-filling of Quotation, Full tank of fuel should be provided after final commissioning.
Base foundation for the Installation of DG ( Appx . Base Size - L-3000 mm x W-1500 mm x H-800 mm ) i) Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed (50 Sq mtr).{ Ref Page-1 Item No- 1) ii) Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge (26.32 Cu mtr).{ Ref Page-12 Item No- 13) iii) Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. (21 Cu Mtr) { Ref Page-1Item No- 2) iv) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) (a) Do - by Silver sand (foundation & plinth) (21 .39 Cu Mtr) { Ref Page-2 ,Item No- 4) v) Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. (Wall & base) (30 Sq Mtr) { Ref Page-14 ,Item No- 1) vi) Ordinary Cement concrete (mix 1:2:4) with graded stone chips....... floor as per relevant IS codes(d) With local hard blackstone variety chips (crusher broken (4.50 Cu Mtr) { Ref Page-10 ,Item No- 27) vii) Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (iv) With local hard blackstone variety chips (crusher broken) (2.70 Cu Mtr) { Ref Page-12 ,Item No- 33)
Supply and Laying of 3.5 core 95 Sqmm XLPE Al/Ar cable laid through UG Trench as per GS. (Make - POLYCAB/GLOSTER/RR Cable)
Supply and Laying of 10 core 2.5 Sqmm Copper Control cable laid through UG Trench as per GS. Make - POLYCAB/GLOSTER/RR Cable)
S/F compression type gland for 3.5 core 90 Sq.mm. Al/Ar cable complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC cables and finishing the end by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS.
S/F earth busbar of galvanized (Hot Dip) MS flat 25 mm x3 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts-- For morum soil
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode (for soft soil / morrum soil) for Genarator Neutral Earthing
Supply and installation of acrylic lettering (imported 3 mm ) signages made of 22 SWG stainless steel 304 grade ,enclosed except the facia. The facia should be made of acrylic. provision should be as such that Inside each letter LED lights(defused type ,waterprof) will glow throughout the letter.The led connect through Driver S/F of 28'x8'x10" ACP sheet of 4mm thickness fixed on iron frame, on which the letters will be fixed. The Letters will be as follows:- Size 10'x6'
BAMBOO STRUCTURE arrangement for scafolding & support the new board by iron structure grouted on fame , painting the iron structure with R.O. primer and final Asian Paint and internal wiring connection as per direction of E.I.C
SITC of Green Model Cooler cum Purifier ( Intregrated inbuilt with cooler and purifier in a single unit ) 80 ltrs storage capacity. with external diamensions 640 mm x 450 mm x 1350 mm ( ± 10% ) , (W x D x H ) , Operating Power Supply - 230 ± 10 % v AC, 50 Hz, running current in amps (max)-3.2 ± 10 %, Power in watts-625 ± 10 %,Water storage tank capacity-80 ltr,capacity with comfort level water outlet temperature at 17 deg c-60 lph,refrigent-r134 ( Green Gas ) 22, Compressor make- Emerson,thermal insulation for storage tank- puf,total no. of faucets-02 (1 normal+1 cold), recommendd max water flow rate through the faucets in lpm-1.5,no of stages for filter cum purifier-03,no of purifier circuits-03,purifier fault indication (buzzer),visual control (leds),water flow swith,10 minutes UV auto shut off,storge tank material & body material- front SS 304 & rest pre coated steel,working with -0.4 kg/cc min. water input pressure and 2 kg/cc of max. water input pressure, integrated water cooler cum purifier with end point/last point purification technology, including one year warranty as per condition. make EUREKA FORBES /KENT / UNILEVER
M/S. S. D. CHATTERJEE AND CO.
MAHESWAR ELECTRICAL INDUSTRIES
GHANASHYAM ELECTRIC STORES
M/S N. C. HORE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .