Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹23.8 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | ₹23.8 L Quoted ₹23.9 L | 1st | Accepted-AOC The M/s SBS Enterprises is L1 bidder being accepted pl. |
| 2 | 2nd₹23.9 L+₹7,051 (0.30%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹23.9 L+₹7,051 (0.30%) | 2nd | Rejected-Finance Not being L1 |
| 3 | 3rd₹24.5 L+₹62,000 (2.60%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹24.5 L+₹62,000 (2.60%) | 3rd | Rejected-Finance Not being L1 |
| 4 | 4th₹24.6 L+₹73,775 (3.09%)Rejected-Finance | ₹24.6 L+₹73,775 (3.09%) | 4th | Rejected-Finance Not being L1 |
| 5 | 5th₹26.2 L+₹2.3 L (9.75%)Rejected-Finance 101 GROUND FLOOR RAJASTHALI ENCLAVE DUMARDAGA RANCHI JHARKHAND 834012 | RANCHI | JHARKHAND | 834012 | ₹26.2 L+₹2.3 L (9.75%) | 5th | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/s Harshal Traders L4 | Shree Ayyappa Engineering L3 | Adinath Technical Services L2 | SBS Enterprises L1 | M/S SHRI SHYAM BUILDERS L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed by Engr-in-charge. | 5 | Cum | 150 ₹750 Lowest | 480 ₹2,400 | 400 ₹2,000 | 450 ₹2,250 | 150 ₹750 Lowest |
| 2.00 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in hard soil complete all as specified and directed by Engr-in-charge. | 40 | Cum | 240 ₹9,600 | 590 ₹23,600 | 400 ₹16,000 | 630 ₹25,200 | 200 ₹8,000 Lowest |
| 3.00 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge. | 35 | Cum | 65 ₹2,275 | 95 ₹3,325 | 200 ₹7,000 | 70 ₹2,450 | 50 ₹1,750 Lowest |
| 4.00 | Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed by Engr-in-charge. | 10 | Cum | 65 ₹650 | 195 ₹1,950 | 200 ₹2,000 | 90 ₹900 | 50 ₹500 Lowest |
| 5.00 | Supply and Laying DWC HDPE IS -16205 Pipe of outer dia of 160 mm and inner dia 135 polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends complete all as specified and directed. | 160 | RM | 240 ₹38,400 Lowest | 440 ₹70,400 | 450 ₹72,000 | 315 ₹50,400 | 600 ₹96,000 |
| 6.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and as directed. | 176 | RM | 2,500 ₹4,40,000 | 2,430 ₹4,27,680 | 2,606 ₹4,58,656 | 2,340 ₹4,11,840 Lowest | 3,000 ₹5,28,000 |
| 7.00 | Supply, install, commissioning & testing of diesel engine driven generating set complete with acoustic enclosure and control system for 100 KW/125 KVA output at site i.e AC 415 volts, 50 C/S, 3 phase 4 wire directly coupled complete with self starting system including accessories, equipment control panel etc as detailed below: (a) Alternator 100 KW output at 0.80 PF AC 3 phase 4 wire 415 volts 50 C/S, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 all as specified and directed . | 1 | Each Job | 18,40,000 ₹18,40,000 | 17,79,905 ₹17,79,905 | 17,52,300 ₹17,52,300 Lowest | 17,55,000 ₹17,55,000 | 19,00,000 ₹19,00,000 |
| 8.00(b) Diesel engine :- Diesel engine water cooled and electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load to full load complete with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and directed. (c) Control panel :- The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for mounting accessories, static energy meter with LED display, digital power factor meter, Digital frequency meter & Digital RPM meter, digital voltmeter 0-500 volts with inbuilt selector switch ,digital ammeter, CT’s operated of suitable rating with inbuilt selector switch, indicator lamps LED type, hours meter, low oil pressure indication, over speed indication and high water temperature indicator (d) Electric starter equipment :- The equipment will comprise the followings :-(i) Maint free Battery duly initial charged & Battery lead of adequate cap. (ii) Starter motor(iii) Starter gearing(iv) Start/stop push button(v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is in off position. (vii) PCC foundation for DG set all as per manufacturer recommendation or required at site or directed by Engineer-in-charge. | ||||||||
| 9.00(e) Auto mains failure panel 415 volts 50 HZ suitable for 125 KVA Gen set detailed at srl item above, made out of 16 gauge MS sheet cubical type floor mounted front and rear door open able with locking arrangement duly powder coated suitable for and including the followings:- | ||||||||
| 10.00(i) Microprocessor based electronic control box for automatic switching on and off of DG set and transfer of load equipped with microprocessor based controller 100% auto , 50% auto manual and 100% by pass arrangement adjustable time delay to engine start, standard setting 3 seconds adjustable 0-10 seconds, adjustable time delay on transfer to normal 0-30 minutes, time delay( adjustable) to engine cool down 0-5 minutes, adjustable time delay on transfer to emergency 0-15 seconds. | ||||||||
Tender Value
₹24.3 L
EMD Value
₹48,600
Closing Date
15 Jun 2026, 6:00 pmClosed
Shri Vinay Kumar, IDSE, SE (SAG), CWE
HQ Commander Works Engineer (Army) Mumbai, 24 Assaye Building Colaba, Mumbai-05
SPECIAL REPAIR /REPLACEMENT OF 125 KVA DG SET AGAINST BER FOR PUMP HOUSE, BAMBOLIM CAMP UNDER GE PANAJI, GOA
2026_MES_767526_1
85302/P/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
PANAJI GOA
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
GE PANAJI GOA
₹48,600
Yes
20 Aug 2026
25 May 2026
17 Jun 2026
25 May 2026
15 Jun 2026
8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed by Engr-in-charge. | 5 | Cum | - | - |
| 2 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in hard soil complete all as specified and directed by Engr-in-charge. | 40 | Cum | - | - |
| 3 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge. | 35 | Cum | - | - |
| 4 | Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed by Engr-in-charge. | 10 | Cum | - | - |
| 5 | Supply and Laying DWC HDPE IS -16205 Pipe of outer dia of 160 mm and inner dia 135 polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends complete all as specified and directed. | 160 | RM | - | - |
| 6 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and as directed. | 176 | RM | - | - |
| 7 | Supply, install, commissioning & testing of diesel engine driven generating set complete with acoustic enclosure and control system for 100 KW/125 KVA output at site i.e AC 415 volts, 50 C/S, 3 phase 4 wire directly coupled complete with self starting system including accessories, equipment control panel etc as detailed below: (a) Alternator 100 KW output at 0.80 PF AC 3 phase 4 wire 415 volts 50 C/S, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 all as specified and directed . | 1 | Each Job | - | - |
| 8 | (b) Diesel engine :- Diesel engine water cooled and electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load to full load complete with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and directed.
(c) Control panel :- The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for mounting accessories, static energy meter with LED display, digital power factor meter, Digital frequency meter & Digital RPM meter, digital voltmeter 0-500 volts with inbuilt selector switch ,digital ammeter, CT’s operated of suitable rating with inbuilt selector switch, indicator lamps LED type, hours meter, low oil pressure indication, over speed indication and high water temperature indicator (d) Electric starter equipment :- The equipment will comprise the followings :-(i) Maint free Battery duly initial charged & Battery lead of adequate cap. (ii) Starter motor(iii) Starter gearing(iv) Start/stop push button(v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is in off position. (vii) PCC foundation for DG set all as per manufacturer recommendation or required at site or directed by Engineer-in-charge. | - | - | - | - |
| 9 | (e) Auto mains failure panel 415 volts 50 HZ suitable for 125 KVA Gen set detailed at srl item above, made out of 16 gauge MS sheet cubical type floor mounted front and rear door open able with locking arrangement duly powder coated suitable for and including the followings:- | - | - | - | - |
| 10 | (i) Microprocessor based electronic control box for automatic switching on and off of DG set and transfer of load equipped with microprocessor based controller 100% auto , 50% auto manual and 100% by pass arrangement adjustable time delay to engine start, standard setting 3 seconds adjustable 0-10 seconds, adjustable time delay on transfer to normal 0-30 minutes, time delay( adjustable) to engine cool down 0-5 minutes, adjustable time delay on transfer to emergency 0-15 seconds. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tenderdocuments85302.pdf
Tender Documents • 1.03 MB
BOQ_859568.xls
BOQ • 10.01 MB
Corrigandom1.pdf
PDF • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .