Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹66.1 L+₹23.2 L (54.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹66.9 L+₹24.0 L (56.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹77.6 L+₹34.7 L (80.9%)Rejected-Finance HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to adverse remarks in WLR in SER No 77 of HQ CENC QE Mar 2022 vide letter No 42594/WLR/AtoD,S/1128/E8 dated 14 Jul 2023. |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
31 Jul 2023, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
PROVN OF CERTAIN LBW REVENUE MINOR WORKS AND SPECIAL REPAIR TO COOK HOUSE BUILDING UNDER GE 865 EWS LEH
2023_MES_607962_1
865/EWS(NIT-74)/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹99,800
Yes
12 Oct 2023
5 Jul 2023
8 Aug 2023
5 Jul 2023
31 Jul 2023
18 Jul 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits,manholes, pier holes, etc. N exc 10 sq m on plan and n exc1.5 m in depth and getting out hard/dense soil,complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits,manholes, pier holes, etc. N exc 10 sq m on plan and n exc1.5 m in depth and getting out in any type of soil,complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed by Engr-in-Charge.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n exc. 1.5 m above the starting point., complete all as specified and directed by Engr-in-Charge.
Supply only broken stone/boulders aggregate for loose filling, of gauge 80 mm to 150 mm graded complete all as specified and directed by Engr-in-Charge.
M & L for providing PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for RCC (nominal mix) Type B-1 , 1:2:4 (using 20mm graded aggregates) foundations, including rafts, footings, foundation, beams, plinth beams, bases for columns etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (nominal mix) Type B-1, 1:2:4 (using 20mm graded aggregates) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC (nominal mix) Type B-1, 1:2:4 (using 20mm graded aggregates) columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for formwork to rough finished flat surfaces of concrete, to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-in-Charge.
M&L for formwork to rough finished flat surfaces of concrete, sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge.
S&F mild steel TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No 14 here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as per specified and directed by Engr-in-Charge.
M&L for RCC (nominal mix) Type B-1, 1:2:4 (using 20mm graded aggregates) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to rough finished flat surfaces of concrete, to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-Charge.
M&L for formwork to rough finished flat surfaces of concrete, to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engr-in-Charge.
M&L for walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by Engr-in-Charge.
M&L for walling of random rubble uncoursed well bonded built in CM 1:6 in retaining walls , abutment , or similar works etc, complete all as specified and directed by Engr-in-Charge.
Dismantling plain or corrugated steel /fibre sheeting any guage thickness including nanital or similar pattern complete all as specified and as directed by Engr-in-Charge.
M&L for hard core of broken stone boulders of guage n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface for filling behind the weep holes complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) 75 mm diameter of outlet, floor trap, plain with grating including jointing to waste pipe with solvent cement complete all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete block masonary type with solid blocks exc. 10cm in width, C-1, (using 20mm graded crushed stone aggregate), set and jointed in cement martar 1:6 complete all as specifeid and directed by Engr-in-Charge.
M&L rendering 15mm thick in CM 1:4 on concrete or brick surfaces as in wall finishes even and fair w/o using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete, type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete, type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces setting in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed by Engr-in-Charge.
M&L for preperation of new concrete /plastered surface of wall any description and applying two coat of oil bound distemper over a coat of primer to obtain smooth finish complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L rendering 15mm thick in CM 1:6 on fair surfaces of concrete or brick surfaces as in wall finishes even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in floor complete all as specified by Engr-in-Charge.
M&L for 75mm thick PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in floor complete all as specified by Engr-in-Charge.
M & L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M & L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engr-in-Charge.
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165 complete all as specified and as directed.
S&F rolled mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections conforming to Fe.410. Gde-E-250 quality B complete all as specified and as directed.
S&F 2nd class soft wood plain, solid, straight chowkets and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as directed by Engr-in-Charge.
S&F for 30mm thick flush shutter solid core construction both side veneered, with block board core commertial type fixed to chowkhat frame complete all as directed by Engr-in-charge.
M&L PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in anchoring hold fast, bed plate etc all as specified and directed.
M&L for preperation of new or previously untreated wooden surface any description of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of Pink primer complete all as specified and as directed complete all as specified and as directed by Engr-in-Charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed by Engr-in-Charge.
S&F for Aluminium, anodised, barrel tower bolts, ISI Marked, of extruded section 200 mm long, complete all as specified and directed by Engr-in-Charge.
S&F for Aluminium, anodised, barrel tower bolts, ISI Marked, of extruded section 100 mm long, complete all as specified and directed by Engr-in-Charge.
S&F for Aluminium, anodized,door handle, ISI Marked, 150 mm long, fabricated type complete all as specified and directed by Engr-in-Charge.
S&F for Aluminium alloy, anodized, door handle, ISI Marked, 100 mm long, fabricated type complete all as specified and directed by Engr-in-Charge.
S&F 100mm long mild steel, medium weight butt hinges of cold rolled complete all as specified and as directed.
S&F 75 mm long mild steel medium weight butt hinges cold rolled complete all as specified and directed by Engr-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engr-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed by Engr-in-Charge.
S&F aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
M&L for plain sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each panes complete all as specified and directed by Engr in charge.
S&F Mild Steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed..
S&F powder coated aluminium anodized door/partly panelled particle wall and partly glazed with 4.5mm thick plain glass sheet/wire mesh and 12mm particle board interior grade both side laminated and aluminium section weight not less than 0.55 Kg/RM with self closing hydraulic door closer and floor spring etc with all fittings complete all as specified and directed by Engr-in-Charge.
S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed by Engr-in-Charge
S&F 9mm thick Prelaminated particle board, interior grade, prelaminated double side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed by Engr-in-Charge
M&L for 2nd class soft wood clean sawn as in scantling fixed with nails, timber framed and fixed as in framed work complete all as specified and directed.complete all as specified and directed.
M&L for 2nd class softwood plain fillets, square, rectangular or triangular in section of sectional area exceeding 13Sqcm and n.exc 25 Sqcm, clean sawn, secured with nails or brads complete all as specified and as directed.
M&L for 2nd class softwood clean sawn, as in battens for grids of ceiling and lining fixed with nails sectional area exceeding 13 Sqcm and n.exc 25 Sqcm, secured with nails or brads including dismantling framed timber scantling under 40 sqcm in section, in fillets, rails, posts, rafters, purlins etc at any position, complete all as specified and as directed.
M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws complete all as specified and as directed
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
M&L for GI powder coated micro preforated micro look false ceiling with fleece lay-in-type, 0.50mm thick, suitable for grid/frame module of 600mm x 600mm size complete with GI powder coated grid consisting of silhonthe main T runner 15mm suspended at 1200mm centre to centre and cross T runner of 15mm size suspended at 600mm centre to centre suspended by 4mm GI rod from roof slab including steel fastner wall angle and T with interlocking arrangement as required for framing grid suitable for module size 600x600mm celing etc complete including dismantling existing wall and ceiling boards (Fiber, pulp insulation and blankets) any thickness including covered fillets and supporting members all as per specified and directed by Engr-in-Charge.
M & L for Gypsum board false ceiling tile 7-8 mm thick with PVC film on the face side and other side metalised polyster flim as in ceilings placed on GI ceiling suspension system powder coated snap grid frame work of size 605 x 605 mm channel supports/ angles/ 'T' (Main tee 35 x 25 x 1.5 mm, cross tee 25 x 25 x 1.4 mm and wall angle 32 x 32 x 2 mm) fixed with screws/ plugs etc including GI suspenders of 6mm dia upto 1200 mm length adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size as per approved pattern and design complete including dismantling existing wall and ceiling boards (Fiber, pulp insulation and blankets) any thickness including covered fillets and supporting members all as per specified and directed by Engr-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. each shutter shall be of 02 Nos -Aluminium handle, 03 Nos of Aluminium hinges, 02 Nos of Tower complete all as specified and directed by Engr-in-Charge.
S&F plain sheet glass 4.80 mm thick, ordinary quality and glazing with oil putty in square or fixed with aluminium section including rubber beads exceeding 0.5 Sq. m in each pane complete all as specified and directed by Engr-in-Charge.
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugations side lap, fixed with J or L hook and washers as in roofs /walls etc. with grade of zine coating 275 complete including dismantling plain or corrugated steel sheeting of any guage thickness including nanital or similar pattern all as specified and directed by Engr-in-Charge.
S&F rolled mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with anglefor 1.50mm thick wall care putty on wall surface complete Fe-410- W(Gde- E-250) quality-B including dismantling existing structural steel work including doors and gates of any description all as specified and directed by Engr-in-Charge.
M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses,columns, pillars, boundary pillars and post complete all as specified and as directed by Engr-in-Charge.
S&F mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engr-in-Charge.
M&L Machine cut pre polished Kota stone slab flooring 20-25 mm thick over 20mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing (granite finish) and exposed edges of kota stone shall be rounded complete all as specified and directed by Engr-in-Charge.
Excavation in post holes (or similar holes) in hard/dense soil ,each n exc 0.5 cum,getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering,and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
Surface dressing n exc 15 cm deep and site clearance in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe 410-W (Gde- E- 250) quality-A complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out hard/dense soil complete all as specified and dire
Excavation over area exc 1.50 m deep and n exc 3.00m in depth and getting out in hard/dense soil complete all as specified and directed.
M & L for Non-Skid coloured ceramic coloured tiles, first quality, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:4 for laying floor finishes complete all as specified and directed.
M & L for Non-Skid coloured ceramic coloured tiles, first quality, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surfaces of size (300mm x 200mm x 7mm thick/ first quality, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments. (Note: Any disturbed surfaces shall be matched w/o any extra cost to the govt) including 10mm thick screed bed below tile for dado/skirting CM 1:4 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surfaces of size (350mm x 250mm x 7mm thick/450x350x7mm) first quality, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments. (Note: Any disturbed surfaces shall be matched w/o any extra cost to the govt) including 10mm thick screed bed below tile for dado/skirting CM 1:4 complete all as specified and as directed.
M&L for vitrified tiles light shade of 10 mm thick (square/rectangular) polished bright, area of tiles not exc 0.36 Sqm as in floors/skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in cement mortar 1.6 complete all as specified and directed by Engr-in-Charge. Make as per PS.
S&F 25mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings like elbow, socket, FTA, MTA etc fixed complete to walls, ceilings or in floors etc. including all fittings for fixing to walls and taking down old existing steel tubing and connections complete all as specified and directed.
S&F 32mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings like elbow, socket, FTA, MTA etc fixed complete to walls, ceilings or in floors etc. including all fittings for fixing to walls and taking down old existing steel tubing and connections complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore single socketed ,in any length with rubber ring joints, laid in trenches or in floors cement complete all as specified by Engr-in-Charge.
S&F PVC (SWR) pipe 110 mm bore single socketed ,in any length with rubber ring joints, laid in trenches or in floors cement including concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) and including dismantling old existing Cast iron/PVC or reinforced concrete pipes jointed in cement mortar complete all as specified by Engr-in-Charge.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate)to drain pipe of bore 100mm dia complete all as specified and directed by Engr-in-Charge.
S&F 35 mm thick 2nd class HW rail and style plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified by Engr-in-Charge.
S&F 30mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge. Make as per PS.
M&L for plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane including hacking out old broken glass (any thick ness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and directed by Engr in charge.
S&F in repair galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engr-in-Charge.
S&F Grating round 140 mm size of PTMT.(Minimum weight 50gms) complete all as specified and directed.
S&F in repair grating 125 mm dia with waste hole size of PTMT.(Minimum weight 40gms) complete all as specified and directed.
S&F chromium plated, brass bib tap, fancy type, screwed down , screwed for iron pipe or for brass ferrule 15 mm bore etc (Min weight 350 gms) complete all as specified and directed by Engr-in-Charge.
S&F in repair 15mm bore bib tap, (minimum weight 350 gms), chromium plated, fancy type, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed
S&F waste coupling for 32mm bore dia of discharge pipe of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and directed.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm with plug washers and wastes including bedding in CM on to dwarf wall or including fixing cantilever bracket and connection union to waste pipe upto 0.5 Sqm each complete all as specified and directed.
S&F 500 litres rotational moulded polyethylene water storage tank, inner and out white, triple layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, including dismantling of old broken water tank n.exc 500 litres capacity complete all as specified and as directed by Engr-in-Charge.Make as per PS.
S&F in repair 110mm bore PVC (SWR) pipe bends any radius complete all as specified and directed by Engr-in-Charge.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillers, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with the shade of granite over 20 mm thicm screed bed in CM 1:4, including rounding and moulding wherever required edges of granite as directed complete all as specified and directed by Engr-in-Charge.
Demolition of precast concrete block/Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in wall panelling, shelves/boarding including dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation, blankets) any thickness including covered fillets and supporting members complete all as specified and as directedcomplete all as specified and as directed by Engr-in-Charge.
M&L for 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling work including dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation, blankets) any thickness including covered fillets and supporting members complete all as specified and as directedcomplete all as specified and as directed by Engr-in-Charge.
S&F in repair PPR gate valve 25mm (brass insert) conforming to ISO 2000 screw down end for PPR pipe or for union and fixed complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick PCC 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) as in flooring and finished surface as in to receive tiles complete all as specified by Engr-in-Charge.
Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc complete all as speciifed and directed by Engr-in-Charge
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated FRLS copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth folly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No 114.00 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No 114.00 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No 114 here-in-before but One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for 3 pin 15 Amps socket outlet independent with FRLS copper conductor cable PVC insulated multistandard 2.5 sqmm with 1.5 Sqmm PVC copper conductor as earth wire connected to earth dolly and including PVC casing caping with sunk cast iron complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to underground cables 8cm below the cable before laying and 15cm above the cable after laying complete all as specified in clause 19.75 of SSR PART -I complete all as specified and directed. Note: Punned thickness of 18cm shall be measured and paid under this item.
Supplying and laying un-reinforced, factory made, machine pressed,precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
S&F switch piano flush type single pole one way 6 Amps ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement switch piano flush type single pole one way 5 Amps ISI marked complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 3 pin 6 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F in replacement socket outlet 3 pin 6 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface backlite two or three terminal complete all as specified and directed by Engr-in-charge.
S&F in replacement ceiling rose surface backlite two or three terminal complete all as specified and directed by Engr-in-charge.
S&F decorative durable LED batten fittings with LED tube 20 watts, 4 feet long with decorative and caps, powder coated CRCA decorative for LED tube including LED retrofit, 4 feet long (white colour) tube of 28 watt having driver, connector block etc with all accessories prewired and connecting to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.copper conductor cable of size 0.75 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. complete all as specified and directed by Engr-in-Charge.
S&F LED bulk head light fitting of 1x9 watts including necessary connection prewired and making connection with 3 core copper flexible cable of appropriate size from ceiling rose /PVC connector to light fittings complete all as specified and directed by Engr-in-Charge
S&F switch socket combination, 5 pin, 6 & 16 Amps piano flush type single pole ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement switch socket combination, 3 pin, 2 in 1 5 Amps piano flush type single pole ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement switch socket combination, 3 pin, 2 in 1, 5 and 15 Amps piano flush type single pole ISI marked complete all as specified and directed by Engr-in-Charge.
S&F recessed mounting white LED luminaries 34 watt, including separate electronic driver and high brightness SMD LEDs ultra modern suitable for amrstrong/grid/POP ceiling in MS housing with high brighness 4000 K LEDs suitable for 230 Volt 50 Hz diffused type optics 2'x2' in size complete with all accessories internally prewired and including connecting up twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
&F in replacement 2' x 2' recessed mounting low depth white LED luminaires 36 W with 36 W lamps white powder coated CRCA sheet housing LEDs front frame with translucent cover fixed to the housing fixed in front frame 36W LED extruded aluminium heat sink projected in false ceiling complete with all accessories internally prewired and including connecting up twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclousure SPN DBs with 200 Amps rated bus bar of 8 way 240 volts with blank plate complete with single door complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal enclousure SPN DBs with 200 Amps rated bus bar of 8 way 240 volts with blank plate complete with single door complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal enclousure SPN DBs with 200 Amps rated bus bar of 4 way 240 volts with blank plate complete with single door complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal enclousure TPN DBs for MCCB 160 Amps rated bus bar of 4 way 415 volts with blank plate complete with double door complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB TPN 160 Amps, 36 KA, 415V, AC ISI marked complete complete all as specified and directed by Engr-in-Charge.
S&F for MCB SPN 40-63 Amps 'C' series, 230 volt, 10 KA complete all as speciied and directed by Engr-in-Charge
S&F MCB SP 6-32 Amps 'C' series complete all as speciied and directed by Engr-in-Charge
S&F in replacement MCB SP 6-32 Amps 'C' series complete all as speciied and directed by Engr-in-Charge
S&F in replacement MCB SPN 40 Amps 'C' series, 230 volt, 10 KA complete all as speciied and directed by Engr-in-Charge
S&F in replacement MCB SPN 63 Amps, 'C' series, 230 volt, 10 KA complete all as speciied and directed by Engr-in-Charge
M&L in replacement for sub main wiring with two run of 6.00 Sqmm (2x6.00 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x6.00 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6.00 Sqmm (2x6.00sqmm), one run of 6.00 Sqmm (1x6.00 sqmm) cable and one metre of PVC casing caping will be measured as one unit.
M&L in replacement lamp holder, PVC/polycarbonate type with black plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge.
M&L for Sub main wiring with two run of 6.00 Sqmm (2x6.00 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x6.00 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down old existing submain wiring complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6.00 Sqmm (2x6.00Sqmm), one run of 6.00 Sqmm (1x6.00 Sqmm) cable and one metre of PVC casing caping will be measured as one unit.
Supply and laying, jointing and testing cable, LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor in size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. Make as per PS.
Supply and laying, jointing and testing cable, LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor in size 25 Sqmm 4 core including taking down old existing cable complete all as specified and directed by Engr-in-Charge. Make as per PS.
S&F in replacement of sheet metal enclosure with 20 Amps 240 V Single pole and neutral enclosure with a two pin and earth plug and socket with one single pole 20 Amp MCB complete with one single pole MCB complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead wire 4 mm dia by means of nuts, bolts, washers etc made of galvanised iron or steel and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including testing on completion and excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix street light brackets 1.5 metre long 40mm bore, GI light grade, with MS clamps complete all as specified and directed.
S&F PVC insulated , PVC sheathed copper conductor cable 1.5 Sqmm 3 core complete all as specified and directed by Engr-in-Charge
SHUBHAM ENGINEERS & BUILDERS
M/S GEE GEE ENTERPRISES
M/S Behl Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .