Loading…
Loading…
Tender Value
₹5.0 L
EMD Value
₹10,100
Closing Date
27 Apr 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
EL/MTC
3 conditions · 2 needing a document upload
I/we have read the General Conditions of Contract (GCC) with all Correction Slips up to date, NIT, Tender Document, Corrigendum (if issued) carefully and submitted all the relevant documents as per the requirement of Tender Document. I/we understand that if I/we failed to submit any required document, my bid will be liable for summarily rejection.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor has to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with a supervisor competency certificate as per Regulation 29 of the Central Electricity Authority (Measure relating to Safety and Electric Supply) Regulation 2010 or latest / as per Rules 45 of the Indian Electricity Rules 1956 along with the tender documents, failing which the offer is liable to be rejected.
Electrification work for Provision of Cabin in Memu shed and MFS Shed in RCF Workshop Kapurthala
RCF-EL-MTC-85-ET-25-26
RCF-EL-MTC-85-ET-25-26
Open
Works - General
120 Days
Kapurthala, Punjab
₹0
₹10,100
27 Apr 2026
4 Apr 2026
13 Apr 2026
27 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,04,545 | ||
| — | 62.00 | — | — | ||
| Supply wiring, testing & commissioning of L/F Point wiring with 2x2.5Sqmm 1100 volt grade multi stranded Copper wire conforming to IS 694-2010 and 1 Sq.mm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply, fixing, testing and commissioning of modular face plate and grid plate as required at site, 5/6amp 1 way modular switch on suitable GI recess/PVC box/flush wall box. All points to be connected with earth wire. Also keep loop to 150 mm long on every end point circuit and point wiring. Make: CPL, SSk, L&T, Anchor, Havels, Hager, Schneider, KEI, Rallison Only. | — | — | — | 24,800 | |
| — | 18.00 | — | — | ||
| Supply, wiring, testing ,fixing and commissioning of 6 pin 16 Amp. Plug point wiring with 2x4Sqmm 1100volt grade multistranded Copper wire conforming to IS 694-2010 and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply, fixing ,testing and commissioning of 16amp.240volt switch socket modular type with modular face plate and grid plate ISI marked to be fixed on suitable GI recess /PVC BOX /Flush wall box. 10amp 1 way modular switch on suitable GI recess/PVC box/flush wall box. All points to be connected with earth wire.Also keep loop to 150 mm long on every end point circuit and point wiring. Make: CPL, SSk, L&T, Anchor, Legrand, Havells, Hager, Schneider, KEI,Rallison only. | — | — | — | 8,820 | |
| — | 54.00 | — | — | ||
| Supply ,wiring ,testing ,fixing and commissioning of 6 Amp. Plug point wiring with 2x2.5Sqmm 1100volt grade multistranded Copper wire conforming to IS 694-2010 from SPN DB with 2x4 Sqmm copper wire conforming to IS 694-2010and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply, fixing ,testing and commissioning of 5 pin socket and 6amp.240volt switch socket modular type with modular face plate and grid plate ISI marked to be fixed on suitable GI recess /PVC BOX /Flush wall box. 6amp 1 way switch on suitable GI recess/PVC box/flush wall box .All points to be connected with earth wire.Also keep loop to 150 mm long on every end point circuit and point wiring.Make: CPL, SSk,L&T, Anchor, Havells. Standard, Hager Only. | — | — | — | 21,600 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing and commissioning of prefabricated 4-way SPN distribution board of sheet enclosed with DP MCB 32Amp.1 nos.,SP MCB 16A-02 nos . Make: L&T,Havells , Legrand, SSk,Anchor,C&S,Siemens,Hager, ABB,Schneider. | — | — | — | 14,760 | |
| — | 450.00 | — | — | ||
| Supply & laying of PVC conduit pipe (Medium Mechanical Strength) /casing Capping of 25mm dia, ISI marked in/on wall including bends, junction boxes and MS saddles etc and repair the same in original shape including whitewash/ distemper after laying of pipe. Make should be ISI Marked Anchor ,Finolex only. | — | — | — | 27,000 | |
| — | 36.00 | — | — | ||
| Supply Installation and commissioning of LED tube Light 18/20 Watt .Make Cromption, Hevells, wipro, Philips, Bajaj. | — | — | — | 7,200 | |
| — | 9.00 | — | — | ||
| Supply, Fixing, testing and commissioning of ventilation fan with grill size 10'', FRP body and grill suitable for single phase 230-volt AC 50HZ supply. Make of Khaitan,Usha, Crompton,Havells, Orient. Note: To fixing of Ventilation Fan in cabin by cutting the wall of sheet of proper size will be in the scope of contractor. | — | — | — | 11,700 | |
| — | 9.00 | — | — | ||
| Supply, fixing, commissioning and testing of evaporate air cooler, Fan size 450 mm copper motor 220-240 AC volt, 50 Hz. Tank capacity 80 ltr,Make Cromption, Khaitan,Usha, Bajaj. | — | — | — | 43,965 | |
| — | 18.00 | — | — | ||
| Supply, fixing, testing and commissioning of oscillating, multi speed 400 mm sweep Bracket fan of make Crompton Greaves including connection etc. Make of Khaitan, Usha,Crompton,Havells,Orient only. | — | — | — | 36,900 | |
| — | 500.00 | — | — | ||
| Supply, laying wiring, testing and commissioning of FRLS Circuit wiring with 2x4sq.mm multi stranded copper conductor wire, conforming to IS -694-2010, with 1sqmm green multi stranded copper wire as earth in existing conduit 25 mm dia. Make: Polycab, L&T,RR kable, KEI, Rallison, Havells,ECKO , Finolex only. | — | — | — | 1,67,000 | |
| — | 9.00 | — | — | ||
| Supply, Installation and commissioning of Surface Mounted Occupancy / presence Sensor indoor type. Make Hager, Scheineder, Legrand. | — | — | — | 58,500 | |
| — | 2.00 | — | — | ||
| Split Air Conditioner 1.5 Ton, Inverter type, eco-friendly refrigerant, wall mounted, star rating 3 star or above, with free standard installation & Commissiong and suitable wall mounted stand for outdoor unit. The Condenser coil, Evaporator coil and other accessories should be copper. The Comprehensive warranty period of air conditioner unit should be 1 year, warranty period of both outdoor and indoor PCB should be 5 years, and warranty period of compressor should be minimum 5 years | — | — | — | 59,800 | |
| — | 9.00 | — | — | ||
| Supply, Installation, Commissioning & testing of SPN 32 amp with Enclosure Make L&T, Havells, Legrand, SSK, Anchor, C &S, Siemens Hager & ABB. | — | — | — | 22,500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderforcabininMHshop.pdf
ATTACHMENT
GCC2022withcorrecionslipupto09.pdf GCC 2022 of works
ATTACHMENT
GCC2022withcorrecionslipupto09.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .