Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹27.7 L+₹71,601 (2.65%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹31.9 L+₹4.9 L (18.0%)Rejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹32.5 L+₹5.4 L (20.2%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹32.5 L+₹5.5 L (20.5%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
1 Jul 2025, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIR REPLACEMENT OF SUB MAIN WIRING POINT WIRING SWITCHES SOCKETS FITTING SUPPLY AND FIXTURES REPAIR TO CEILING EXHAUST WALL MOUNTED FANS AT CABS STIR CEMILAC UNDER GE I R AND D EAST BANGALORE
2025_MES_708651_1
8607/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹92,000
Yes
4 Aug 2025
5 Jun 2025
8 Jul 2025
5 Jun 2025
1 Jul 2025
19 Jun 2025
5 Jun 2025 - 18 Jun 2025
Amount
Taking down carefully un serviceable aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, removing all material for reuse/ issued under sch of credit and making good the disturbed surface as the existing one, complete all as directed.
Material and labour for point wiring complete with multi stranded copper conductor size 1.5 sq.mm PVC insulated, unsheathed, FRLS cable, 1100 volts grade conforming to IS 694 multistranded, drawn in casing and caping fixed on wals / floors/ ceiling etc with and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sq.mm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasses to the walls / floors/ ceiling and repairing with existing surface after work complete all as specified and directed.
One light/ fan/exhaust fan point controlled by one way switch.
One three pin socket outlet 6 amps socket on the same board with other switches .
One 3 pin socket point 6 Amps on the independent board with other switches.
One bell point controlled by one bell push .
All as per Sl Item No 2 here-in-before but using copper conductor 2.5 sq.mm PVC insulated unsheathed FRLS cable with copper conductor size 1.5 sq.mmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 Amps socket outlet independently all as specified and as directed.
Supply and fix switch modular type single pole 1 way 6 Amps 230 volt complete all as directed.
Supply and fix socket 6 Amps 2/3 pin modular type, 230 volts all as directed.
Supply and fix switch modular type 1 way 16 Amps, 1 module all as specified and as directed.
Supply and fix Socket modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as directed.
Supply and fix modular switch bell push 6 Amps one module all as specified and directed.
Supply and fix modular type fan regulator 120 Watt two module complete all as specified and as directed.
Supply and fix bell music AC 230V single phase all as specified and directed.
Supply and fix ceiling rose surface bakelite two to three terminal complete all as directed.
Supply and fix angle holder polycarbonate/bakelite type with back plate complete all as specified and as directed.
Supply and fix in replacement of LED type 4 feet tube light batten fitting surface mounted of 20 Watts extruded aluminium housing high lumen output complete all as specified and as directed.
Supply and fix in replacement of LED mirror light fitting surface mounted of capacity of 10 Watt with plastic body and accessories complete all as specified including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and as directed.
Supply and fix in replacement of LED type surface mounted decorative bulk head fitting edge lit of 10 Watts complete including connecting to ceiling rose with twin copper conductor of size 0/0.24 all as specified and as directed.
Supply and fix LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete including taking down old one complete all as specified and as directed.
Supply and fix LED luminaire 300 mm x 300 mm, 24 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete including taking down old one complete all as specified and as directed.
Supply and fix LED luminaire 600 mm x 600 mm, 30/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete including taking down old one complete all as specified and as directed.
Supply and fix LED luminaire suspended type suitable for 36 watt, 1x4 ft, 220 V AC commercial surface type with complete fitting with driver, holders and LED lamp with fixing all arrangement in roof/ ceiling including all connecting up with driver three core flexible copper conductor cable of suitable size complete including taking down old one complete all as specified and as directed.
Supply and fix LED luminaire Recess type suitable for 36 watt, 1x4 ft, 220 V AC with complete fitting with driver, holders and LED lamp with fixing all arrangement in all type of spaces such as office reception area, meeting room and corridors including all connecting up with driver three core flexible copper conductor cable of suitable size complete including taking down old one.
Supply and fix LED round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
All as per Sl Item No. 21 above but12 watt.
All as per Sl Item No. 21 above but15 watt.
All as per Sl Item No. 21 above but18 watt.
Supply and fix High efficiency LED tube 4 pin with in built driver and superior lumens in lower wattage of 18 watt 220 volts AC complete with drivers, holders, LED lamp suitable for fixing in old tube light fitting including connecting up with three core flexible copper conductor cable of suitable size all as per Philips HSN Code : 85395000 or techno commercially equivalent in Havells / Crompton complete all as specified and as directed.
Dismantling the ceiling fan/exhaust fan/wall fan/air circulator complete of any type and size from various buildings and cleaning, servicing, greasing to bearings checking of nuts, bolts, safety split pin, bushes , capacitor and complete testing fans, blades, down rod etc and refixing the site / building with complete connections all as directed. NOTE :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted.
Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper winding from the rotor assembly and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling, greasing to bearing, replacing bushes, replacement of capacitor and two coats of white spray painting complete testing all as directed. NOTE :- (a) The spares like ball bearing, capacitor and GM bush required for repairing of the ceiling fan will be measured and paid separately under respective items of this BOQ. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
All as per Sl Item No.27 herein before but for 1400 mm sweep ceiling fan.
All as per Sl Item No.27 herein before but for 300 mm sweep exhaust fan .
All as per Sl Item No.27 herein before but for 450 mm sweep exhaust fan .
All as per Sl Item No.27 herein before but for wall fan upto 450 mm sweep plastic body .
All as per Sl Item No.27 herein before but for industrial fan/air circulator upto 600 mm sweep, 240 volt 1400 RPM metal body .
Supply and replace worn out fan bearings of the existing size of superior quality complete all as specified and directed .
Supply and replace capacitor 2.5mfd suitable for 1200mm sweep ceiling fan complete all as specified and directed .
Supply and replace capacitor 4.0mfd suitable for exhaust fan complete all as specified and directed.
Supply and replace rubber reel of superior quality along with gun metal frame and split pin complete all as specified .
Supply and fix exhaust fan with louvers on outside of the external wall suitable for 300/ 380mm sweep for G+4 buildings including all fixing arrangements like ladder / scaffolding required if any complete all as specified and as directed.
Supply and fix exhaust fan louvers on outside of the external wall suitable for 300/ 450 mm sweep for G+4 buildings including all fixing arrangement like ladder/scaffolding required if any complete all as specified and as directed .
Material and labour for submain wiring of 2 run 1.5 sq.mm size PVC insulated unsheathed multi stranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit with all accessories in surface type including one run of 1.5 sq.mm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge. NOTE :- 3 run of 1.5 sq.mm can]ble and one run of PVC conduit shall be measured as one RM.
Material and labour for submain wiring of 2 run 2.5 sq.mm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit with all accessories in surface type including one run of 2.5 sq.mm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge. NOTE :- 3 run of 2.5 sq.mm cable and one run of PVC conduit shall be measured as one RM.
Material and labour for submain wiring of 2 run 4 sq.mm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit with all accessories in surface including one run of 4.0 sq.mm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge. NOTE : 3 run of 4 sq.mm cable and one run of PVC conduit shall be measured as one RM.
Material and labour for submain wiring of 2 run 6 sq.mm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories in surface type including one run of 6.0 sq.mm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge. NOTE :- 3 run of 6 sq.mm cable and one run of PVC conduit shall be measured as one RM.
Material and labour for submain wiring of 4 run 10 sq.mm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit in surface type including accessories and one run of 10.0 sq.mm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge. NOTE :- 5 run of 10 sq.mm cable and one run of PVC conduit shall be measured as one RM
Material and labour for submain wiring of 4 run 16 sq.mm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit in surface accessories including one run of 16.0 sq.mm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge. NOTE :- 5 run of 16 sq.mm and one run of PVC conduit shall be measured as one RM.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one no 20 Amps MCB SP C curve type with complete connection all as directed and specified.
Supply anf fixing triple pole and earth enclosure with a three pin and earth plug with socket complete with one no triple pole MCB 20 Amps type with complete connection all as directed and specified.
Supply and fix triple pole and neutral enclosure with a three pin and earth plug and socket complete with one no 32 Amps MCB TP C curve type with complete connection all as directed and specified.
Supply and fix in replacement of MCB DB TPN 4 way DB double door type three phase 415 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 4 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 8 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed .
Supply and fix in replacement of MCB DB SPN 12 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed .
Supply and fix in replacement of MCB DB SPN 16 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed .
Supply and fix in replacement of MCB SPN 6-32 Amps C Curve type 230 Volts single phase all as specified complete including dismantling the old one.
All as per Sl Item No. 53 but capacity of MCB SPN (40-63) Amps
Supply and fix in replacement of MCB SP (6-32) Amps C Curve 230 Volts single phase all as specified complete including dismantling the old one complete all as specified and directed.
Supply and fix in replacement of MCB TP (25- 63) Amps C Curve type 415 Volts three phase all as specified complete including dismantling the old one complete all as specified and directed.
Supply and fix in replacement of MCB TPN (16-32) Amps C Curve 415 Volts three phase all as specified complete including dismantling the old one complete all as specified and directed.
Supply and fix in replacement of MCB TPN (40-100) Amps C Curve 415 Volts three phase all as specified complete including dismantling the old one complete all as specified and directed.
Material and labour for repair to existing broken switch board by taking out the old existing switches, sockets, regulators flush type and refixing the same after replacement of hylam sheet of required size under mentioned with complete electric connections and making screws and made functional with all electric connections as per specified and directed by Engr-in- charge. NOTE :- Switches , sockets, regulators, hylam sheet, if required at site then it will be measured and paid separately.
Supply and fix in replacement of Hylam sheet with not less than 3mm thick of size 4" x 4" complete all as specified and directed.
Supply and fixing in replacement of Hylam sheet with not less than 3mm thick of size 4" x 6" complete all as specified and directed.
Supply and fixing in replacement of switch piano flush type 6 Amps one way type including taking down old one complete all as specified and directed.
Supply and fixing in replacement of switch piano flush type 16 Amps one way type including taking down old one complete all as specified and directed.
Supply and fixing in replacement of socket 5 pin flush type 6 Amps including taking down old one complete all as specified and directed.
Supply and fixing in replacement of fan regulator flush type switch type 450 watt including taking down old one complete all as specified and directed.
Supply and fixing in replacement of fan regulator flush type socket type 100/120 watt including taking down old one complete all as specified and directed.
Supply and fixing in replacement of Switch socket combination 2 in 1, 6A flush type including taking down old one complete all as specified and directed.
Supply and fixing in replacement of Switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal type including taking down old one complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 4.0 mm dia GI wire up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB all as shown in electrical plate No. 3 of SSR Part I and all as specified including testing on completion, taking down old unserviceable earthing complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 32 x 6mm upto 7.5Mtr GI strip up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB all as shown in electrical plate No. 3 of SSR Part I and all as specified including testing on completion, taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm including taking down of old un serviceable complete all as specified and as directed.
Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of 4mm dia galvanised iron or steel wire incl taking down of old unsv complete all as specified and as directed.
Supply and fixing of aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground including taking down of old unsv complete all as specified and as directed.
Supply and fixing air termination, single pointed aluminium rod 12 mm dia and 300 mm long including taking down of old unsv complete all as specified and as directed.
Supply and fix copper strip 25x3.15 mm with saddles and fixing screws etc for roof/wall conductors and down conductors above ground including taking down of old un serviceable complete all as specified and as directed.
Supply and fix Flame proof cum Water proof LED Bulk Head light fitting 60 W, IP-66 rotection of Cast Aluminum alloy material and Heat and Impact resistance toughend 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable including taking down of old un serviceable complete all as specified and as directed.
Supply and fix LED light fitting 2x16/ 20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA and IIIB, Zone 1 and 2 and IP- 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including taking down of old un serviceable one complete all as specified and as directed.
Material and labour for cleaning of TPN DB box in each building by blower and checking the all incomer/outgoing MCBs/TPNs etc and tight the all electric loose connections and fixing of copper lugs through existing MCBs and after painting the complete the TPN DB Box as directed by Engr in charge
Taking down defective geyser/ storage water heater of any pattern/ capacities from existing position/place comprising of the following tasks:- (a) Inspecting, taking down (dismantling), descalling, brushing, cleaning of storage tank and painting internally with one coat of proprietary bituminous composition not liable to impart taste or odour or otherwise contaminated water (b) Examine water tightness of storage tank after cleaning (c) Carryout operation of all stop cock, pressure reducing valves etc to ensure free movement of the working parts (d) Replace washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow/vent pipes and remove blockages obstructions if any (f) Check and correct earth continuity of electrical parts (g) Check, maintain and adjust thermostats and tests its functioning (h) Checking and adjustment of pressure reducing valve (j) Checking of dead weight type high pressure release valve (HPRV) by removing dead weight position cleaning the seat and ensuring that the vent hole is not blocked /chocked.
Supply and fix in replacement of heating element of 2.0 KW rating as required at site (round and Triangle) including rubber washers of ISI marked complete all as specified and directed.
Supply and fix in replacement of thermostat for the geyser of following capacities with ISI marked -
Supply and fix in replacement of PVC connection pipe with two brass adaptors 450mm long and connecting up complete all as specified and as directed (as per sample).
Material and labour for chemical earthing complete with copper earth plate electrode 900 x 600 x 5 mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32 x 6 mm by means of riveting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, magnesium sulphate & vegetable soil all around the plate 15 cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge..
MAJ CONSTRUCTIONS (BID ID -3343288)
G K CONSTRUCTIONS (BID ID -3333064)
Varsha Enterprises (BID ID -3335636)
GS TRADERS (BID ID -3334685)
GKR and CO (BID ID -3341561)
SRI LAKSHMI ASSOCIATES (BID ID -3334928)
KRD ASSOCIATE (BID ID -3342741)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .