Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.9 L+₹24,940.08 (0.87%)Rejected-Finance VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Highest | |
| 3 | L3₹30.6 L+₹1.9 L (6.68%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Highest | |
| 4 | L4₹30.6 L+₹2.0 L (6.85%)Rejected-Finance | L4 | Rejected-Finance Highest | |
| 5 | L5₹37.6 L+₹9.0 L (31.3%)Rejected-Finance SUBHASH CHOWK BARMER RAJSTHAN 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Highest |
Tender Value
₹37.9 L
EMD Value
₹75,760
Closing Date
15 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BARMER
Military Engineer Services, Jalipa Military Station, Garrison Engineer (Army), Barmer, PIN 344001
SPL REPAIR TO MAG NO 08 BLDG NO P 50 OF 25 AMN COY AT MIL STN JASAI UNDER GE ARMY BARMER
2023_MES_633290_1
8740/E8
Open Tender
Civil Works
Item Rate
240 days
GE ARMY BARMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY BARMER
₹75,760
5 Feb 2024
18 Dec 2023
20 Jan 2024
18 Dec 2023
15 Jan 2024
1 Jan 2024
Amount
Taking down cement plaster on stone masonry/Brick Masonry incl racking out joints, hacking for key scrubbing down with water complete all as specified and directed.
M&L for 15 mm rendering in CM 1:4 on fair face of wall or on concrete surfaces finished even with water profinfing compound (WPC) and smooth without using extra cement complete all as specified and directed. (WPC will be measured and paid separately)
Supply only liquid water proofing compound ( For external new plaster surfaces).
M&L for 15 mm rendering in CM 1:6 on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5 mm rendering in CM 1:4 on fair face of ceiling or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying two coats of oil emulsion distempering over a coat of interior wall primer complete all as specified and directed.
M&L for Preparing of new plastered/unplastered surfaces of walls and applying Two coat of cement base paint over one coat of Primer as camouflage pattern complete all as specified and directed .
M&L for Preparing New plaster surface of Ceiling and applying Two coat of oil emulsion distemper on ceiling of approved tints complete all as specified and and directed
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level ), complete all as specified and directecd.
M&L for PCC (1:3:6) type C-1, 75mm thick, as in plinth protection, using 20mm agg and other similar work including necessary form work complete all as specified and directed.
Demolition of stone masonry built in cement mortar including all quoins or pillars etc complete all as specified and directed.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for stone masonry walling of random rubble, uncoursed , well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone complete all as specified and directed.
M&L Extra over stone walling for hammer dressing with maximum depression on face straight edge held against the dressed surface not exceeding 20mm of sand stone to face stones and dressing of face beds and joints, as specified for random rubble walling, uncoursed or brought up to courses complete all as specified and directed.
M&L for 15 mm rendering in CM 1:4 on fair face of wall or on stone masonary surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 as in Coping, using 20mm agg and other similar work including necessary form work complete all as specified and directed.
Demolition of cement concrete (unreinforced) in roofs, floors (other than ground floors), beams, staircases,landing, chajjas and similar suspended work complete all as specified and directed.
M/L plain cement concrete 1:2:4 type B1 using 12.5 mm graded aggregate as in roof for maintaining the uniform slope etc of any thickness at any height and in any position complete all as specified and directed.
M&L APP based polymeric modified membrane minimum weighing not less than 3kg / Sqm and minimum 3mm thick reinforced with polyester non woven fabric weight not less than 150 gms / Sqm and on primed surface of one coat of approved bituminous [email protected] Ltr per Sqm by torch application method with 150mm over lap on length side & 100mm on width side complete all as specified and directed.
M&L Cement concrete tiles 20cm x 20xm x20mm thick, machine pressed, set, jointed and pointed in net cement shurry with grey cement and no pigment in Roof, (Over 15 mm thick Screed bed CM 1:6) and cut and polished complete all as specified and directed.
Supply only Integral water proofing compund( for screed bed )
M&L for complete removal of existing treatment of wall or roof surfaces, removing unnecessary nails including filling of cracks/holes by crack filler and applying two coats cement based paint over a coat of with alkali resistant primer complete all as specified and directed.
M&L for Complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks/holes by crack filler, removing unnecessary nails applying two coats of oil bound distemper/ emulsion over a coat of interior wall primer complete all as specified and directed.
M&L for Complete removal of existing treatment, plastered or unplastered old surfaces of ceiling and applying two coat of oil emulsion distemper on ceiling over a coat of primer of approved tints complete all as specified and and directed
M and L for complete removal of existing treatment from old decorated steel surfaces of any description, not otherwise described over 10cm width & girth and applying two coat of synthetic enamel paint camouflage pattern over a coat of red oxide primer complete all as specified and directed .
Taking down carefully from roof/ wall of the building loose/ hanging/ de-shaped, aluminium strips of any size & type including unserviceable insulators etc complete all as specified and directed.
Refixing serviceable aluminium strips of any size as obtained from srl item No. 26 above with porcelin insulators of 15 BMD size 'T' type placed not more than 50cm apart with screws /nut/bolts etc complete all as specified and directed.
S&F aluminium strip 25mm x 3.15mm fixed with saddleS& Fixing screws of size not less than 4 mm dia and 32 mm long for roof conductors and down conductors above ground with porcelin insulators of 15 BMD size 'T' type placed not more than 50cm apart with screws /nut/bolts etc complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75 mm X75 mm X25mm drilled and screwed including 4 nos. 8mm dia 25 mm long hexagonal head brass screws, and screwed to wall for protection of test point including 80 mm x 80 mm x 40 mm PVC box for Gun made block fix to the wall by means of screws and nuts including taking down old unserviceable test terminal point complete all as specified and directed.
M&L for Air termination, single pointed, Aluminium rod 12mm dia and 300mm long fixed with the roof in and including all fittings, fixtures shaddles insulators etc. including taking down old unserviceable Air termination rod of any size complete all as specified and directed.
Taking down carefully from wall / surface of the building loose/ hanging/ de-shaped, GI strip of any size type including unserviceable Galvanised iron pipe of any dia bore complete all as specified and directed.
Refixing serviceable GI strips of any size as obtained from item above with GI pipe of any size on wall/floor with clamps and nuts and bolts of suitable size etc complete all as specified and directed.
M&L Galvanised iron strip 32 mm x 6 mm burried in ground/PCC hard standing /fixed on wall including all necessary excavation and earth work, connecting at ends, jointing etc complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green) suitable for flame proof (FLP) cross for zone 192 gas group 11A and 11B with 2.5 sqmm nominal cross sectional area, multi standerd flame retrdant low smoke (FRLS) insulated unsheathed copper conductor cable 1100V grade IS-694 marked TAC and FIA approved in and including surface mounted with saddles rual plug and fixing screws etc heavy duty electric resistance welded (ERW) stove enameld steel conducts ISI marked as per IS:9537 (Pt-1) 1980 of 20/25mm size with all flame proof conduit accessories such as bends, elbows tees etc certified by CMRI dhanbad as suitable for flame proof areas and sealad with teflon tape on all conduits accessories and the sectional area multi stranderd flame retardant low smoke (FRLS) insulated, unsheathed copper conductor cable of size 2.5 sqmm 1100V grade IS-694 marked TAC and FIA approved as earth continiuty conductor connected to common earth all as specified including taking down old wirings etc and deposited to MES store yard and as directed for the followings: (a) Three light point controlled by one MCB provided in main DB.
All as per srl item No 34 above but Four / Five light point controlled by one MCB provided in main DB.
Material and labour in repair for flame proof steel conduit and material and labour for cable drawn through flame proof conduits complete with 4 sqmm single core multistranded copper conductor PVC insulated, and unsheathed cable 1100 volts grade on sunk cast iron terminal boxes with 4.0 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly with and including necessary connection to MCB/Flame proof switch/Flame proof light fittings/Flame proof Sockets etc all as directed. Note:- 2 runs of 4 sqmm and 1 run of 4 sqmm cable as earth wire and 20/25mm dia conduit shall be measured as 1 RM
Supply and Fix in replacement CIMFR certified LED flame proof Bulkhead/ Wellglass luminaire recommended for Gas/ Vapour Group of 11A & 11B and Zone 1&2, Die cast Aluminium Housing with heat resistant toughned glass IP65 protection all as per Cat Part No. FWL1315-60-CDL of Crompton or techno commercially equivalent make of Philips/ Sudhir Switchgear complete all as specified and directed.
Supply and Fix in replacement CIMFR certified flame proof LED batten/tubelight fittings designed for twin T8 tube of 16W/20W which can be replaced and easily serviceable from bottom for hazardous area Group of 11A & 11B and Zone 1&2, Die cast Aluminium Housing with heat resistant toughned glass IP65 protection including 02 Nos. T8 tube rod 16/20 Watt LED all as per Cat Part No. EXTN2LT8-16/20 of Crompton or techno commercially equivalent make of Philips/ Sudhir Switchgear complete all as specified and directed.
M & L for replacement of U/S plate earthing with bore well earthing by drilling bore with bore machine for lightening protection system using GI pipe heavy duty 50 mm dia as earth electrode driven up to a depth of 50 meters below ground level, duly made holes at 20 cm intervals, along the length of GI pipe and providing the charcoal salt mixture incl GI pipe 150 mm dia light grade as protection upto a depth of 12 meters and GI strip of 32x6 mm so as to acheive desired earth results with testing and commissioning complete all as specified and directed. (Earth strip of size 32x5mm upto a length of 7.5m is deemed to incl in this item rate).
m/s jogaram sujaram
M/s Malinath Electricals
m/s sai construction company,bijarar
Paliwal Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .