Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.9 L+₹5.9 L (28.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹26.9 L+₹6.0 L (28.4%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹29.0 L+₹8.0 L (38.1%)Rejected-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L4 | Rejected-AOC L4 | |
| 5 | L5₹29.3 L+₹8.3 L (39.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹29.9 L
EMD Value
₹60,000
Closing Date
24 Feb 2023, 5:00 pmClosed
XEN Electrical Division No. 1 Shimla
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
CO Himachal Niketan at Dwarka Sector19 New Delhi SH SITC of CCTV System therein
2023_PWD_68849_1
Electrical Division-I dated 10.02.2023
Open Tender
Electrical Works
Item Rate
730 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,500
₹60,000
5 Jul 2023
14 Feb 2023
25 Feb 2023
14 Feb 2023
24 Feb 2023
14 Feb 2023
Amount
Supply Installation and Commissioning of Microprocessor based Intelligent SITC of 5MP Dome Camera 1/ 2.8 inch or better, CMOS & Progressive Scan. Video Codec/ Compression H.265+, H.265, H.264 or better. 4mm Fixed Lens. WDR 120dB. Signal-to-Noise Ratio (SNR) 52dB or better. Internal Illuminator with visibility should be at least 30 meters. Video Resolution & Frame Rate 5MP (2592x1944) @ 20 FPS, 2MP (1920x1080) & 720P (1280x720) @ 25/30 FPS. Image Settings HLC, BLC, Defog, 2D/3D DNR, Privacy Mask & White Balance (Auto/ Manual). Video Streams Dual Stream, Individually configurable video streams (H.265+, H.265, H.264) At least 1 stream at 5MP @ 20FPS. Audio Interface Built-in Mic. Audio Codec G.711. Casing . IP67, IK10 with Built-in Surge & Lighting Protection. Certifications - UL 62368-1, CE, FCC, BIS. Make: Axis /Bosch /Pelco /Norden (eyenor) /Avigilion/Honeywell Or its Equivalent approved by Engineer-in-Charge
SITC of 5MP Bullet Camera 1/ 2.8 inch or better, CMOS & Progressive Scan. Video Codec/ Compression H.265+, H.265, H.264 or better. 4mm Fixed Lens. WDR 120dB. Signal-to-Noise Ratio (SNR) 52dB or better. Internal Illuminator with visibility should be at least 30 meters. Video Resolution & Frame Rate 5MP (2592x1944) @ 20 FPS, 2MP (1920x1080) & 720P (1280x720) @ 25/30 FPS. Image Settings HLC, BLC, Defog, 2D/3D DNR, Privacy Mask & White Balance (Auto/ Manual). Video Streams Dual Stream, Individually configurable video streams (H.265+, H.265, H.264) At least 1 stream at 5MP @ 20FPS. Audio Interface Built-in Mic. Audio Codec G.711. Casing . IP67, IK10 with Built-in Surge & Lighting Protection. Certifications - UL 62368-1, CE, FCC, BIS. Make: Axis /Bosch /Pelco /Norden (eyenor) /Avigilion/Honeywell Or its Equivalent approved by Engineer-in-Charge.
SITC of 64 channels Network Video Recorder with 48 TB HD. Should support 8 SATA hard disk slot and each should support 10TB HDD. Should support JBOD & RAID 0, 1, 5, 6, 10. Image and Video specification. H.265+, H.265, H.264 compression. Video Input – 64 IP camera minimum. Video Resolution support 12MP/8MP/ 6MP /5MP/4MP/ 3MP/1080P/ UXGA / 720P/ VGA/4CIF/DCIF/2CIF/CIF/QCIF. Adjustable Image Quality. VBR and CBR support. Each channel should support multi-level motion detection. Matrix Display: 1/3/4/6/8/9/10/13/16/20/25/32/36/40/64. OSD Display. Physical Ports. Video Output: 2ch VGA and 2ch HDMI. Audio Interface: 1ch In & 1ch Out. Serial Interfaces: 1# RS232, 2# RS485. Network: 2 RJ45, 10M/100M/1000M LAN port. Alarm Interface: 16ch In & 4ch Out. USB Port: 1# USB3.0, 2# USB2.0 ports. Recording and playback. Should support schedule, motion and alarm-based recording. Incoming /Outgoing Bandwidth should be 320 Mbps or better. Synchronous Playback. Time/Date based search mode. Alarm based search. VCA detection alarm should be supported. Should Supports data transfer via USB, e-SATA & Network for easy and fast backup of data. Support megapixel HD network video preview, storage and playback. Digital Zoom support on any user specified area in live screen. Should support digital zoom in both Live and Playback. Should support Playback and backup based on event search. Internet Explorer 6.0 or later. Multiple Language GUI. Iphone, Android Phone Support. Humidity: 10% to 90% (non-condensing) Certifications - UL 62368-1, CE, FCC, BIS. Make: Axis /Bosch /Pelco /Norden (eyenor) /Avigilion/Honeywell Or its Equivalent approved by Engineer-in-Charge
SITC of 8 Switch should be Web Manged, Should have 8 port 1000BASE-T with 2 Port 1000BASE-T PoE PoE power budget 120 Watt or higher, Maximum Per port PoE Power 30 WattIEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Ethernet,IEEE 802.3ab 1000BASE-T Ethernet, IEEE 802.3az EEE support,IEEE 802.3x flow control,IEEE 802.3z 1000BASE-X,IEEE 802.1p CoS,IEEE 802.3af PoE, IEEE 802.3at PoE Plus, IEEE802.1Q VLAN Tagging, Minimum 8 VLAN supportPort based VLAN, IEEE802.3ad link aggregation should be MAC based Switching Capacity 16 Gbps,Packet buffer 192KB,MAC address support 4K Jumbo frame support 9K, Should support loop detection,Should support Broadcast storm control QoS Support (WRR and strict priority) Port based QoS 20 Multicast group or higher, Maximum power consumption 72W,Operating temperature 0°C to 40°C Storage Temperature -40°C to 70°C Certification: CE, FCC, C-Tick, , LVD EN60950-1, ROHS compliant.Should be built-in IEEE 802.3az Energy Efficient Ethernet (EEE) Make:Cisco/Alied/Zyxel/Juniper/D-Link Or its Equivalent approved by Engineer-in-Charge
SITC of Layer-2 POE plus Gigabit Ethernet 1RU chassis with 24 PoE 10/100/1000 BaseT ports and 4 Gigabit SFP ports. Includes an internal AC power supply 370W atleast or higher power budget) with a power cord, manuals access card, and RJ-45 to DB-9 adaptor.The Access Switch should have 4 ports of 1 G SFP.The Access Switch should provide Non-Blocking switch fabric capacity of 56 Gbps or more. L-2 switch should provide wire-speed packet forwarding of 41 Mpps or more. L-2 Switch should support min 16K MAC addresses and min 4000 active VLANs. Make:Cisco/Alied/Zyxel/Juniper/D-Link Or its Equivalent approved by Engineer-in-Charge
SITC of 24-port 19" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19" 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated Make R&M/Systimax/Seimon/Norden/Honeywell Or its Equivalent approved by Engineer-in-Charge.
SITC of CAT6 UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m onforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 Make R&M/Siemon/Systimax/Juniper/D-Link Or its Equivalent approved by Engineer-in-Charge
SITC of 6U Rack with 2 side FAN with 3 socket PDU with 15 AMP DP for power surge safty. With pole mount accessories. Rack should be certified. Make: Valrack, Netrack, Comrack Or its Equivalent approved by Engineer-in-Charge
SITC of 19U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack Or its Equivalent approved by Engineer-in-Charge.
SITC of 55" LED Monitor, Full HD, HDMI Port, Component Video Inputs, 1 Digital Audio Out, Make: Sony/Panasonic/Samsung Or its Equivalent approved by Engineer-in-Charge.
SITC of 2 KVA Online UPS Overvoltage cut-off device (OVCD),Support for up to 42 AH external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for IndianEnvironmental Condition andfor Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup MAKE APC/ LIBERT EINOVA/DELTA/Emerson/Numeric Or its Equivalent approved by Engineer-in-Charge
SITC of CAT 6 UTP Cable.Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report. Make: Panduit/R&M/Systimax/Juniper/D-Link) Or its Equivalent approved by Engineer-in-Charge
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Vowels Technology and Services
RG Security Solutions Private Limited
Insat Techno Services
AVNET SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .