Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹22.0 L+₹2.7 L (14.1%)Rejected-Finance NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | L2 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
19 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
OFFICE OF CHIEF ENGINEER COAST GUARD VISAKHAPATNAM MILITARY ENGINEER SERVICES D NO 39 4 2 2 PLOT NO 18 NEAR VARMA COMPLEX MURALINAGAR VISAKHAPATNAM 530 007
PROVISION OF LIFT FOR CGDHQ-5 (TN) CLIVE BATTERY BUILDING AT CHENNAI
2021_MES_429969_1
CE CG CHN TOKEN 20 OF 2020 2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chennai
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE I CG CHENNAI
₹58,000
Yes
7 Jun 2021
11 Mar 2021
21 Apr 2021
11 Mar 2021
19 Apr 2021
30 Mar 2021
60 days
Amount
Taking down/dismantling existing unserviceable lift at DHQ -5 (Clive battery) and hand over to user unit/Chennai Port Trust authroites all as specified and directed. Note:-(i ) contractor shall make good any damage caused to surface of lift shaft & machine room during the dismantling at his own cost and no seprate payment will be made on this account. (ii) Contractor/OEM should ensure that all safety condition/accessories as per latest IS/safety instruction on elevator are catered while quoting.
Design supply, install, testing and commissioning of 08 passengers Lift (544 Kg capacity) in the existing lift well, speed 1.0 metre/sec, lift with single speed motor suitable for 415 Volts, 3 phase, 50 Hz AC supply operation, conforming to IS-14665, suitable to serve Five upper floors (G+5) alongwith basement floor i.e. with 07 stops and 7 landings(Travel/rise 29 metre approx) with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system, 2D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room , Guard Room & near Ground floor landing door), complete all as specified and directed including all civil works required in connection with erection of lifts complete all as specified. Make: OTIS/Jhonson/IES elevators/KONE/Premier Engg Systems/Thyssen Krupp The lift shall be provided with and including the following :-
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity : Passenger elevator for 08 persons (544Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.0 metre per second. (iv) Travel: Suitable for passenger travel of Approx 29 metres (opening on same side). (v) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5% of Voltage). (vi) Car enclosure: SS false ceiling with stainless steel mirror finishes with CD-41 (base) and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail suitable dia. Mirror finish of 4mm thickness of suitable size recommended by Engr-in-Charge. Car size shall be in conformity with IS 14665 (Part-III):2000 varying from 1.13 Sqm to max 1.45 Sqm. Recommended car size 1.43Sqm (Length: 1.30 metre and Breadth 1.1 metre.) (vii) Flooring: Polished granite flooring. (viii) Electric light: LED Light fitting (Min 06 Nos). (ix) Fan: Cross flow fan – 01 No. (x) Car entrance: Automatic, centre opening, sliding doors. (xi) Clear opening: Not less than 800mm x 2000mm high. (xii) Door Operation: Automatic operation. (xiii) Control: Simplex full collective with and without attendant. (xiv) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors. (xv) TFT: LCD Display
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Specification plate with complete details (iv) Overloading device. (v) Nudging (buzzer if door is held open for more than 30 Sec). (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeble arrangement for battery. (xvi) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (xvii) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Coated steel belt with sensor of adequate size as per relevant IS and as per manufacturer specification. (xix) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes control panel, locks governer, car operational panel power control and trailing cables complete.
(c) ADDITIONAL FEATURES Automatic Rescue Device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LCD digital position indicator display. (vi) Fireman’s switch at main lobby. (vii) Manual rescue operation. (viii) Call register indicator in all landings. (ix) Attendant operation system in car panel. (x) Over load and floor announcement audio and visual arrangement. Note: Existing lift well dimensions are Length is 2590mm and Bredth is 1905mm and Floor to Floor height is 2920mm . Pit Depth= 1600mm; Lift Room SIzeL=7000mm;B=5000mm;H=2770mm
Earthing complete with GI earth plates electrode 600x600x6mm thick burried directly in ground earth pit not less than 4.5 mtr deep below ground level with top edge of earth plate not less than 1.5m below GL the plate surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate including 25 Kgs of bentonite using, using GI earth strip 32x6mm connected to earth plate by means of nut ,bolts and washers GI pipe light grade 50mm bore for protection of strips from edge of earth plate to transformer plinth including water pipe of size light grade 50 mm from earth chamber to edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick pre-cast RCC 1:2:4 type B-1 dully reinforced with MS bars 6mm dia @100 c/c both ways with 10mm dia MS bar including lifting handle excavation earth work etc all as directed in electrical plate No 3 of SSR pt I complete all as specified and directed.
Supplying and fixing GI strip 32 mm x 6 mm complete laid in trenches / ducts fixed on steel structure complete all as specified (in extn of earthings).
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, onefour core cable flat or circular16 sqmm. Make: Havells/Gloster/Polycab
PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as infoundation/coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair all as specifid and directed.
PREMIER ENGINEERING SYSTEMS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .