Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹39.4 L+₹1.9 L (5.00%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹43.6 L+₹6.1 L (16.2%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹49.8 L+₹12.3 L (32.8%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-AOC Other than lowest bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
21 May 2021, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon NEAR ATUL KATARIA CHOWK GURGAON 122005
GE (P) AF/GUR 10/2021 22 PROVN OF ROOF TOP SOLAR SYSTEM AND CERTAIN SPECIAL REPAIRS TO INTERNAL WIRING LT POWER SYSTEM AND WATER SUPPLY PIPE LINES AT 27 ED AND 13 BRD AF STN PALAM UNDER GE(P) AF GURGAON
2021_MES_438063_1
GE (P) AF/GUR-10/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
AS SPECIFIED IN NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹99,000
Yes
2 Jun 2021
23 Apr 2021
24 May 2021
23 Apr 2021
21 May 2021
7 May 2021
Amount
Schedule-A
Excavation of trenches in soft/loose soil, not exceeding 1.5 meter wide & not exceeding 1.5 meter in depth and getting out, trimming the sides forming bottom surfaces top required level complete all as specified and as directed by E-in-Charge.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cms thick in each layer of solid complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance n’exc 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point all as specified and directed by Engineer –in-Charge.
Supply and fixing 90mm dia, 3 Layer (Inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/ceilings or laying in floors complete of size outer dia, including fittings as in replacement complete all as specified as directed by Engr-in-charge.
Supply and fixing 50mm dia, 3 Layer (Inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/ceilings or laying in floors complete of size outer dia, including fittings as in replacement complete all as specified as directed by Engr-in-charge.
Supply and fixing 32mm dia, 3 Layer (Inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/ceilings or laying in floors complete of size outer dia, including fittings as in replacement complete all as specified as directed by Engr-in-charge.
Supply and fixing 16mm dia, 3 Layer (Inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/ceilings or laying in floors as in replacement complete of size outer dia, including fittings complete all as specified as directed by Engr-in-charge.
Supply and fixing of PPR Fly Wheel gate valves (Brass Insert) outer dia 20mm as in replacement complete all as specified as directed by Engr-in-charge.
Supply and fixing of PPR Fly Wheel gate valves (Brass Insert) outer dia 32mm as in replacement complete all as specified as directed by Engr-in-charge.
Supply and fixing of PPR Fly Wheel gate valves (Brass Insert) outer dia 50mm as in replacement complete all as specified as directed by Engr-in-charge.
Supply and fixing of PPR Fly Wheel gate valves (Brass Insert) outer dia 90mm as in replacement complete all as specified as directed by Engr-in-charge.
Taking out old unserviceable galvanized iron tubing 50mm bore medium grade with all fittings laid in trenches floor/ road complete all as specified and directed.
Taking out old unserviceable galvanized iron tubing 25mm bore medium grade with all fittings laid in trenches floor/ road complete all as specified and directed.
Supplying and Fixing of sluice valve cast iron size 100mm bore PN 1.6 with brass spindle and fly nut flaged both ends and drilled for jointing wheel head type including two flanged joints with nuts, bolts and washer, rubber insertion packing etc as in replacement complete all as specified as directed by Engr-in-charge.
Supplying and Fixing replacement of sluice valve cast iron size 80mm bore PN 1.6 with brass spindle and fly nut flaged both ends and drilled for jointing wheel head type including two flanged joints with nuts, bolts and washer, rubber insertion packing etc complete all as specified as directed by Engr-in-charge.
Supply and fixing replacement of Gun Metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm bore complete all specified and as directed by Engr-in-Charge.
Supply and fixing as in replacement of Gun Metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm bore complete all specified and as directed by Engr-in-Charge. (Note :New work Pipe Cutting job paid seperately)
Supply and fixing as in replacement of Gun Metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm bore complete all specified and as directed by Engr-in-Charge. (Note :New work Pipe Cutting job paid seperately)
Material and labour for brick masonry valve pit of size 90cms x 90cms x 90cms (internal dimensions of chamber) depth to be reckoned from the top of PCC foundation to top of MS cover as shown on drgs with MS sheet cover 3 mm thick including frame of angle iron 40mm x 40mm x 6mm with locking arrangement including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in cement mortar 1:6 , 15mm thick plastering in cement mortar 1:4 (Internal and external) and necessary excavation and earth work in any type of soil returning, filling in disposal of surplus spoil to a distance not exc. 50 metres, 15cm thick PCC 1:4:8 type D-2 for base complete all as specified and directed by Engineer-in-charge.
Material and labour for cutting of existing CI/GI pipe line of size upto 100mm dia bore (supply main) and making connection by inserting CI Tee/CI collar etc and connecting to new PP-R Pipe line/GI Pipe line dia upto 90mm complete all as specified and directed by Engineer-in-Charge.
Excavation of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B2 using 40mm grade stone aggregate as in copping of electric pole or making good of disturbed surface complete all as specified and as directed by Engineer-in-charge.
M&L complete for driling hole hard standing / road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any complete all as specified and directed by Engineer-in-charge.
S&F GI Tubing medium grade of size 80mm bore for LT cable protection complete all as specified and as directed by Engineer-in-charge.
S&F GI Tubing medium grade of size 50mm bore for LT cable protection complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick masonry valve pit of size 40cms x 40cms x 40cms (internal dimensions of chamber) depth to be reckoned from the top of PCC foundation to top of MS cover as shown on drgs with MS sheet cover 3 mm thick including frame of angle iron 20mm x 20mm x 6mm with locking arrangement including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in cement mortar 1:6 , 15mm thick plastering in cement mortar 1:4 (Internal and external) and necessary excavation and earth work in any type of soil returning, filling in disposal of surplus spoil to a distance not exc. 50 metres, 15cm thick PCC 1:4:8 type D-2 for base complete all as specified and directed by Engineer-in-charge.
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed by Engr-in-Charge.
Taking out 95 Sqmm 3.5 core old serviceable /unserviceable underground cable of following sizes from excavated trenches /pipes complete as sepecified and directed by Engr-in-Charge. (Earth work, segregating cable cover measured separately).
Taking out 70 Sqmm 3.5 core old serviceable /unserviceable underground cable of following sizes from excavated trenches /pipes complete as sepecified and directed by Engr-in-Charge. (Earth work, segregating cable cover measured separately).
Taking out 50 Sqmm 3.5 core old serviceable /unserviceable underground cable of following sizes from excavated trenches /pipes complete as sepecified and directed by Engr-in-Charge. (Earth work, segregating cable cover measured separately).
Supplying , laying , passing through pipe , connecting and testing 95 Sqmm 3.5 core UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of Following size (Note:- Excavation & earthwork etc shall be measured and paid sepretaly) all as specified and as directed by Engr-in-charge.
Supplying , laying , passing through pipe , connecting and testing 70 Sqmm 3.5 core UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of Following size (Note:- Excavation & earthwork etc shall be measured and paid sepretaly) all as specified and as directed by Engr-in-charge.
Supplying , laying , passing through pipe , connecting and testing 50 Sqmm 3.5 core UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of Following size (Note:- Excavation & earthwork etc shall be measured and paid sepretaly) complete all as specified and as directed by Engr-in-charge.
Labour only for taking down old unserviceable ACB of rating 800 Amps to 2500 Amps complete with and from existing location in panel box after taking shutdown of power supply and taking all necessary precaution without damaging the existing panel board complete all as specified and as directed by Engr-in-charge.
S&F of Air Circuit breaker 800 Amps, 4 pole, 415 V, 50 Hz with Microprocessor release and drawout type with Neutral Overload Protection - OFF-50 %-100 % and Icu=Ics=Icw(1s)=50 kA,In Built Temperature Protection, specification as given below . (Make: HAVELLS CAT no IHAFE21080**# for (Manual) or equivalent make of ABB/Schneider/Legrand), complete all as specified and as directed by Engineer-in-charge and with provn of following:- (a) OFF(O)/ON(I) button. (b) Main contact position indicator. (c) Energy storage mechanism status indicator. (d) Reset Button. (e) LED Indicators. (f) Controller. (g) “Connection”, “Test” and “isolated” position stopper (the three-position latching/locking mechanism). (h) User-supplied padlock. (j) Connection “,” Test “and” separation “of the position indication.
(k) Connection (CE) Separation, (CD) Test (CT) Position indication contacts . (l) Rated Name Plate. (m) Digital Displays. (n) Mechanical energy storage handle. (o) Shake (IN/OUT). (p) Rocker repository. (q) Fault trip reset button. (r) Rotatable Terminals for Horizontal/Vertical Orientation . (s) Note: The fixing of the ACB in existing panel requires minor shaping, turning and welding work of the bus bar system which are deemed to be inclusive in the quoted rates. No extra payment whatsover is applicable for such work associated during fixing of ACB in replacement. The rates are also inclusive of testing and commissioning after fixing .
S&F of Air Circuit breaker 2500 Amps, 4 pole, 415 V, 50 Hz with Microprocessor release and drawout type with Neutral Overload Protection - OFF-50 %-100 % and Icu=Ics=Icw(1s)=75 kA,In Built Temperature Protection, specification as given below . (Make: HAVELLS CAT no IHAFE21250**# for (Manual) or equivalent make of ABB/Schneider/Legrand), complete all as specified and as directed by Engineer-in-charge and with provn of following:- (a) OFF(O)/ON(I) button. (b) Main contact position indicator. (c) Energy storage mechanism status indicator. (d) Reset Button. (e) LED Indicators. (f) Controller. (g) “Connection”, “Test” and “isolated” position stopper (the three-position latching/locking mechanism). (h) User-supplied padlock. (j) Connection “,” Test “and” separation “of the position indication.
(k) Connection (CE) Separation, (CD) Test (CT) Position indication contacts . (l) Rated Name Plate. (m) Digital Displays. (n) Mechanical energy storage handle. (o) Shake (IN/OUT). (p) Rocker repository. (q) Fault trip reset button. (r) Rotatable Terminals for Horizontal/Vertical Orientation . (s) Note: The fixing of the ACB in existing panel requires minor shaping, turning and welding work of the bus bar system which are deemed to be inclusive in the quoted rates. No extra payment whatsover is applicable for such work associated during fixing of ACB in replacement. The rates are also inclusive of testing and commissioning after fixing .
Supply, fixing, testing and commissioning of SMF Battery 65 AH/ 12 V (Make: HBL/Exide /Quanta) as in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F Sheet metal eoclosure for DBs when MCBs to be used triple pole neutral 8 way, double door 415 V rating including taking out unserviceable DBs by carefully disconnecting the existing connections, complete all as specified and as directed by Engr-in-charge.
M&L for cutting holes into or through brick walls built in brick walls, built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required n exc. 150 Sq. Cm in supreficial area all as specified and as directed.
Taking down copper/aluminium point wiring (light points) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed .
Taking down unserviceable/burnt, copper/aluminium submain wiring complete, including conduits of any kind, and removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (heavy grade), exposed to surface wherever required including conduit as specified, and making good to surface by using CM 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also, complete including modular metal flush box, modular white cover plate with frame and PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and as directed by Engr-in-charge.
All as per item No 42 hereinbefore but for 5/6Amp Socket outlet on independent board.
All as per item No 42 hereinbefore but for 5/6Amp Socket outlet on same board.
All as per item No 42 hereinbefore but for Power point 16/20 Amps wiring using 4 sqmm copper conductor PVC insulated and unsheathed cable with copper cable as earth wire 2.5 mm 2 PVC Insulated un sheathed multistranded complete all as specified and as directed by Engr-in-Charge.
M&L for wiring sub main wiring concealed along with earth wire with the following size of FRLSH PVC insulated and unsheathed multistranded copper conductor single core cables in concealed through 25 mm rigid non metalic PVC conduit heavy duty with 4 x 6 sqmm + 2 x 4 sqmm earth wire complete all as specified and directed by Engineer-in-Charge. including cutting chesses pinning in making good to facing and pointing in cement morter1:3 to the ends or cutting chesses for conceled point wiring and making good distrubed surface complete cutting not exceeding 4 cm girth and 4 cm width . Note:- Two run of cable and one length of PVC conduit with earth conductor shall be measured as a one length complete all as specified and as directed by Engr-in-Charge.
All as per item No 46 hereinbefore but with 4 x 4 sqmm + 2 x 2.5 sqmm earth wire.
M&L for recess/ surface mounting LED flat panel 2'X2' light fitting, fabricated out of CRCA sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffuser, IP20 complete with all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable with suitable size.Make: Halonix, CAT No: HLFPR22-02-36 CW-R or equivalent of Bajaj/Philips/CG)
M&L for energy LED corrossion resistant batten with polycarbonate housing and opal diffuser, IP 65 complete with suitable lamp, 40 Watt and all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable of suitable size.Make: Halonix, CAT No: HLB-04-40-CW or equivalent of Bajaj/Philips/CG)
M&L LED box channel luminarie made out of CRCA sheet suitable for 1 x 20 Watt LED T8 including LED T8 tube, IP 20 complete all as specified and as directed. (Make: Halonix, CAT No: HLIB-05-118 LED-1S or equivalent of Bajaj/Philips/CG)
S&F exhaust fans AC single phase 230/240 V of size 450 mm sweep with louver (HSN Code-8414,Make-Havells/Bajaj or equivalent) complete all as specified and as directed by Engr-in-charge.
S&F fans ceiling complete with electronic type regulator and accessories 230V, 1200 mm sweep, BEE 5 star rated (Model/Description-Zinger50,Make-Standard/Havells or equivalent) complete all as specified and as directed by Engr-in-charge.
S&F Switch modular 10 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular 16 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 6 Amps multtipurpose complete all as specified and directed by Engineer-in-Charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 16 Amps multtipurpose complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose,3 phase PVC polycarbonate complete all as specified and directed by Engr-in-Charge.
S&F Sheet metal enclosure for Load line DBs when MCCBs to be used triple pole neutral 4 way, double door 415 V rating complete all as specified and directed by Engr-in-Charge.
S&F industrial wall mounted plug socket suitable for IP 67 degree of protection 16 Amps rating 3P+N+E (CAT no-507862,Make-Legrand) complete all as specified and as directed by Engr-in-charge.
S&F RCBO for earth leakage, overload and short circuit protection, 32 A, four pole, 30 mA complete all as specified and as directed by Engr-in-charge.
S&F MCB, SP, Breaking capacity min 10KA,'C' curve 230V, 6 to 32 Amps complete all as specified and as directed by Engr-in-charge.
Supplying , laying , passing through pipe , connecting and testing 16 Sqmm 4 core UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of Following size (Note:- Excavation & earthwork etc shall be measured and paid sepretaly) and including taking out old unserviceable cable complete all as specified and as directed by Engr-in-charge.
M&L for LED post top lantern solar PV system, 20 Watt with remote embedded in die cast aluminium spigot, spun aluminium powder coated top cover, aluminium PDC heat sink, opal PDC diffuser and clear acrylic, IP 65, 115.4WH, 14.8V Li-ion battery complete all as specified and as directed with lamp complete (Make : Synergy wave system Ltd. CAT No SWLL-12 or equivalent make of Philips/Bajaj/CG).
S&F Thermoplastic Polycarbonate Insulated material for junction box with glass fiber reinforced. The Polycarbonate junction box shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid& anti corrosive, IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded.The junction box shall be complying the standards IEC 60670 – 1 & IEC 60670 – 22. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate. For better safety the Polycarbonate enclosure shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960ºC and the impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. (Make: HENSEL/Spelsgeberg/ Syntex) Size – (205 x 255 x 112) mm Cat part No – KF2500B of HENSEL or equivalent of Spelsgeberg/ Syntex Colour – Black Internals –4 Pole Terminal Suitable upto 25 sq mm along with one 6ASP MCB, Cable Gland – Size M32 - 2 nos ( cat no 1555.32.25 + 8232) of HENSEL or equivalent of Spelsgeberg/ Syntex, Size M25 – 1 no ( cat no 1555.25.17 + 8225) of HENSEL or equivalent of Spelsgeberg/ Syntex, complete all as specified and as directed by Engineer-in-Charge.
M&L for highly efficient LED street light made out of pressure die cast aluminium housing with high power LEDs, lens and toughened glasses, IP 66 with lamps complete all as specified and as directed by Engineer-in-Charge. (Make : Halonix, CAT no: HLSLD-06-150 CWL-R or equivalent make of Philips/Bajaj/CG)
Supply & Fix copper conductor single core FRLSH cable of size 2.5 sqmm stranded PVC insulated for connection of fittings(Street light and flood light) of street light poles complete all as specified and as directed by Engineer-in-Charge.
Design, Supply, Installation, Testing & Commissioning of on grid connected roof top solar pv plant for generation of 30.40 kwp(+2% extra spares), comprising of Design & provision of solar panel treated with anti glare coating with mono Crystalline PV Module, roof top structure power conditioning unit (Inverter, IP 41, Power evacuation equipment such as cable and Panels. Fire safety kit, earthing and lightening arrestors, all accessories etc including preliminary and pre-operative charges & Comprehensive Maintenance charges for 5 years including all essential civil and electrical works required for erection and commissioning of Solar PV plant. The inverters shall consist of online data loggers for monitoring of solar power generation and solar meters/bi directional meters of suitable specification to be installed for complete/ utilization of solar power generated on grid with in the desired location only complete all as specified and as directed by Engineer-in-Charge with the following materials and specifications:-
(a) Solar Module (390 Wp Mono Crystalline-78 Nos, Make Waaree Energies Ltd or equivalant out of makes specified in list of makes. (b) Solar Inverter (3Ph-30 kw)-01 No Make-Waaree Energies Ltd/ KS or equivalant out of makes specified in list of makes. (c) Module Mounting Structure (HDGI/AL.ANODISED)-01 Set, Make as specified in list of makes. (d) DC Wire (4Sqmm Cu)-500 mtr Make-Polycab or equivalanr out of makes specified in list of makes. (e) AC Cable -100 mtr Make-Polycab or equivalanr out of makes specified in list of makes. (f) ACDB (Poly Carbonate) -01 No Make as specified in list of makes. (g) RMS -01 No Make as specified in list of makes. (h) GI earthing with chemical compound-03 Nos Make as specified in list of makes. (j) Earthing strip (25x3mm / Copper wire)-100 Mtr Make as specified in list of makes. (k) Lightening arrester (conventional)-1 No Make as specified in list of makes. (l) PVC conduit (25/40mm) Heavy conduit-100 mtr Make- Kalinga or equivalanr out of makes specified in list of makes. (m) Water Pump 0.50 HP-01 No Make- Kirloskar/CG or equivalanr out of makes specified in list of makes.
NOTE No 1: The Plant shall produce minimum generated electricity of 46400 units per year. The work shall be carried out as per sound drawings including the following:- (a) Standard/Approved makes of auxilary transformer cables, cable trenches and covers, modules, inverters and all connected electrical items and solar power generation items, etc to be incorporated as per design. (b) Bidder Shall consider local geographical conditionss/meteorological data at the location for the required design period.
Note No 2: The Contractor shall submit design and drawing vetted from National Institute of Solar Energy Gurugram or by Govt Institute authorised by MNRE or NISE or any reputed Institute /Agency authorised for approval of GE. The cost of design and all other works shall be deemed included in the quoted rate of the item.
Note No 3: Comprehensive Maintenance of solar power plant shall start from next day after completion, installation and commissioning of solar power plant and all other civil, electrical/and mechanical work. The scope of Comprehensive maintenance shall be as under:- (a) Comprehensive maintenance shall include washing/ cleaning of Solar PV Modules Periodically as per pre-planned schedule. (b)Checking electrical parameter of the installed power plant. (c) Any other job other than above indicated jobs shall be covered under warrenty of Solar plant installed. (d) Keeping the area neat and clean free from vegetations growth.
Note No 4: Payment against Sch 'A' item No.67 shall be regulated as under :- (a) For material brought at site payment shall be done as per condition 64 of IAFW 2249. (b) After complete installation and testing :- 80% of rate quoted against Sch'A' item No 67 proportionally building wise as per SPV generation given here in above less retention money and payment already made. (c) After Comissioning : After complete installation, testing and comissioning 90% of rate quoted against Sch'A' item No.67 (less retention money and payment already made) (d) Comprehensive maintenance : Balance 10% of rate quoted against Sch'A' item No 67 hereinbefore. The payment for 05 years out of this 10% shall be 1.5%,1.75%, 2%, 2.25% and 2.5% respectively for 1st, 2nd, 3rd, 4th & 5th year of comprehensive maintenance. Half yearly payment shall be made proportionaly to the total amount due for the year (e) The payment against Comprehensive maintenance shall be further subject to satisfactory operation and meeting desired output on daily basis. This means that for each day when the SPV plant is not operational and meeting desired output on daily basis. This means that for each day when the SPV plant is not operational for any reason whatoever, no payment for those days, (on proportional basis) shal be made.
Comprehensive Maintenance of SPV System:- (a) The Comprehensive maintenance is for a period of 05 Years w.e.f. satisfactorily completion of the equipments installed under Item No 67 of BOQ hereinbefore. (b) The Contractor Shall be responsible for periodical maintenance as specified including renewal/replacement of parts fittings/fixtures filling of Solar modules, inverter, mounting structure etc. (c) Maintenance of log sheet and all maintenance record shall be responsibility of contractor and stationary shall be provided by the Contractor. Format of logsheet and maintenance records etc shall be decided by GE/Engr-In-Charge. (d) Solar Panel water servicing, panel Cleaning, Area cleaning surround the plant room etc shall be the responsibility of contractor. (e) The work covered under this schedule shall be ordered on the contractor by the GE every year through a separate work order at the rate quoted by the contractor till completion of five years comprehensive maintenance.
Note:- a) A firm other than OEM having rating of 1A/1B/1C/2A/2B/2C issued by CRISIL/SMERA/ICRA specified for solar firms shall submit the MOU from OEM within 15 days of acceptance of contract for Design, Supply, Installation, Testing & Commissioning of on grid connected roof top solar pv plant for generation and Comprehensive Maintenance of SPV System for 5 years against item No 67 hereinbefore.
Note The amount of Rs 73,485/- against Schedule of Credit on Page No 123 to 124 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
MAHABIR SINGH
SYNERGY WAVE SYSTEM LLP
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .