Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹6.9 L+₹1.5 L (29.1%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
27 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
PROVN OF CERTAIN MINOR AND REVENUE WORKS UNDER GE AF EM CHAKERI KANPUR
2021_MES_417613_1
8435/E8
Open Tender
Civil Works
Item Rate
60 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹14,000
6 Mar 2021
30 Jan 2021
5 Mar 2021
30 Jan 2021
27 Feb 2021
13 Feb 2021
60 days
Amount
Supply, installation, commissioning and testing of hi wall split type AC indoor & outdoor complete with cordless remote control unit and inbuild air ionizer and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.5 of capacity as shown electric driven (single phase (2.0 TR) outer unit shall be fitted with discharged cooled type rotory/ scrolled type compressor operating on non-CFC refrigerent R-410 A and copper tube type condenser including copper piping as required between both the units with suction pipe, discharge pipe, PVC drain pipe 15 mm diameter and electric cable from inner unit to outer unit shall be properly included, taped and covered with heavy duty PVC conduit and properly fixed on wall/ ceilings etc complete all as specified and directed.
Supply and Fix of Voltage stabilizer for copper wound automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage at 230 V with accuracy of + 2.5% and cap of 5 KVA complete all as specified and directed. Make: V Guard / Blue Bird/ Vintek
M&L for submain wiring with two single core FRLS PVC insulated unsheathed, multstranded flexible copper conductor 1100 Volts grade cables 4 Sqmm drawn through in and including rigid PVC heavy duty surface conduits not less than 20 mm bore including 4 Sqmm 1100 Volts grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Make- Havells/Finolex/Polycab.
Supply and fixing sheet metal enclosures with metal plug and socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed. Make- Legrand/Havells/IndoAsian/ABB.
Supply and fixing sheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) Triple pole and neutral 415 Volts 4 way with 200 Amps rated busbar complete all as specified and directed. Make- Legrand/Havells/Indo Asian/ABB
Supply, laying on wall surface and fixing properly by PVC rigid clip connecting with electric supply and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed. Make- Havells/Polycab/Finolex
S&F MCB single phase 32 Amps 10 KA, AC , 220V complete all as specified and directed. Make: Havells/Legrand/ABB.
S&F MCB TPN AC 415 V, 50 Hz 63 Amp, 10 KA complete all as specified and directed. Make: Havells/Legrand/ABB.
M & L for making high conductie, non corrosive, maintenance free yet repairable, Chemrod Electro Chemical Gel earth pit suitable for lightning conductor application using earth enhancing compound tecel ISOGEL of 20 Kg kit, CPRI tested ISOROD of 3 inch dia, 8 fit long and 0.12 inch thick made of 'K' type elctrolytic copper with top removal gel filling cap, seepage holes, Stainless steel fasterns , HDP lockable earth pit cover pit cover cum inspection/ termination chamber and all required accessories including design modification complete all as specified and directed. Note: (i) Earth work shall be included in this unit rate (ii) Connecting copper strip for equipment of 32 x6 mm upto 7.5 Mtr will be included in this unit rate. (iii) Test point to be made on insulation base i.e. poecelean insulator or burried in ground.
S&F copper strip 32 x6 mm on wall/ batten or recessed or buried in ground complete all as specified and directed.
Labour for transporation of Boom Barriers (02 Nos) from MES storeyard to work site in AFS Chakeri, Kanpur having distance not less than 4 Kms by engaging sufficient skilled manpower and machinery for safe and smooth relocation without any damage and installation of it after servicing so as to make it operational as per OEM's recommendation in any position/ place complete all as specified and directed. NOTE: Bidder must take note of the fact that any damage occuring to boom barrier due to relocation shall be born by contractor without any extra cost to Dept.
M&L for providing new earthing for bldg complete with galvanised GI steel earth plate of size 600 x 600 x 6.0 mm with G I earth strip of size 32 x 6 mm and earth pit not less than 2.25 mtr deep below normal ground level with top edge earth of the plate not less than 1.50 mtr below normal ground level connected to G I strip (32 x 6 mm ) from earth plate to test point by means of MS bolts, nuts, check nuts including char coal dust, common salt, funnel with wire-mesh, 20 mm dia light grade GI pipe for watering and 40 mm dia GI pipe light grade for protection of GI strip and excavation / earth work with PCC pit 1 : 3 : 6 type C2 using 40 mm graded stone aggregate and RCC cover of 40 mm thick with 1 : 2 : 4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel round bar 75 mm C/C both way with two Nos 12 mm dia MS handle complete all as shown in electrical plate No 3 of SSR Part I, the rates includes testing charges complete all as specified and directed. Note Earth GI strip, GI protection pipe beyond 7.5 m shall be measured and paid separately.
S&F 32 x6 mm galvanised iron strip as earth lead fixed to wall/ burred in ground/ drawn in conduit/ pipe or fixed to polies or any other indicated situation etc complete all as specified and directed.
M & L for hardcore of gauge n exc 63 mm broken stone or boulders, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified.
M & L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in foundations, coping including finished all exposed surfaces of concrete including weathering, slightly rounded or chamfered angle and throating including necessary form work filling and mass concrete complete all as specified and directed.
M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base floor with finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
Supply, laying and testing cable PVC Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 2.5 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for new dry well burnt standard brick sub class B size laying in trenches for cable protection complete all as specified and directed.
Taking down of DG set of 320 KVA capacity from its original location and shifting it to a new location within 1km distance by engaging sufficient manpower and machinery for safe loading, hoisting, transportation and unloading without any damage and fixing it to a new platform with 4 mm GI wire mesh over platform complete all as specified and directed. Note:- Bidders must take note of the fact that any damages occuring to DG set due to shifting work shall be rectified and borne by the contractor without any cost to the department.
S & F Rolled mild steel in angle or T section as post / column independently, without connecting plates including cutting & welding etc. and similar work confirm to FE -290 Gde E-165 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description exc 10 cm in width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide primer all as specified and directed.
S&F 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet "colour" having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with self tapping screws and bituminous washers complete all as specified and directed.
M & L for surface excavation in soft / loose soil not exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core complete all as specified and directed.
M & L for relocation of existing 12.5 Mtr High Mast system from one location to another location (Approx distance 5 KM) complete with control panel and connected accessories such as head frame alongwith lights, which motor, trailing cable, aviation light etc. Hight Mast shall have fixed on new platform with PCC (1:4:8) type D2 using 40 mm graded stone crushed aggregate, open raft shallow footing type foundation and foundation depth not less than 1.5 M below ground level including 04/06 Nos foundation bolts and length of foundation bolts is 26 mm dia, 750 mm long incluidng earth excavation & making good disturbed surface and necessary connection complete all as specified and directed. NOTE: Excavation, foundation material and transportation deemed to include in the quoted rate.
Supply & Laying jointing, testing and commissioning LT XLPE insulated, PVC sheathed armoured LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, duct, on ploles, in trenches etc of size 35 sqmm x 3.5 core cable complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 using 20 mm graded stone aggregate complete all as specified and directed.
Supply & fixing or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing etc of size 40 mm bore complete all as specified and directed.
Supply, fixing, installation and testing LT pannel out door (Kiosk type), wheather & vermin proof MS sheet housing 3.15mm thick, double door front & rear openable type mounted on 50x50x6mm to cover all corner and standing legs (Min 75cm) of angle iron work, with coloured horizontal Tinned aluminium bus bar 4 pole, mounted on insulators of rating 200 Amps, one MCCB, 4pole 100 Amps, 25 KA 415 volts at incoming supply. The panel size not less than 600x450x300mm with cable gland, duly powder coated, locking arrangement complete and including grouting in PCC block of suitable size complete all as specified and directed.
S & F Flame proof batton for twin LED tube of 2 x 20W CIMFR certified suitable for gas and vapour and IP 65 protected on wall / roof incl. all fixing accessories complete all as specified and directed.
S & F Flame proof and weather proof rotary type switch suitable for 240V, 10A parameters single pole with termination box in LM6 to be fixed on wall / roof complete all as specified and directed.
S & F Flame proof and weather proof exhaust fan AC single phase 240 V of size 600 mm sweep with louver to be fixed on wall / roof incl. cutting of holes, re-plastering it and making good the disturbed surface complete all as specified and directed.
M & L for point wiring using PVC FRLS copper conductor of size 1.5 sqmm for phase to be drawn in stove enamled steel conduit including earth wire PVC FRLS copper conductor of size 1.5 sqmm incl. fixing of clamps, nuts, bolts, washers etc. including stove enamalled steel conduit not less than 20 mm bore complete all as specified and directed.
PAWAN COOL CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .