Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.6 LAccepted-AOC | ₹31.6 L | 1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | 2₹36.3 L+₹4.7 L (14.9%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | ₹36.3 L+₹4.7 L (14.9%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹37.2 L+₹5.5 L (17.5%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹37.2 L+₹5.5 L (17.5%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹37.4 L+₹5.8 L (18.2%)Rejected-Finance | ₹37.4 L+₹5.8 L (18.2%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹37.5 L+₹5.9 L (18.5%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹37.5 L+₹5.9 L (18.5%) | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹35.6 L
EMD Value
₹71,300
Closing Date
25 Sept 2021, 6:00 pmClosed
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
SPECIAL REPAIR TO BUILDING NO P-5 AT OLD CANTT PATIALA MIL STN
2021_MES_471382_1
GE(N)/PAT-42/2021-22
Open Tender
Civil Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹71,300
Yes
13 Oct 2021
28 Aug 2021
27 Sept 2021
28 Aug 2021
25 Sept 2021
11 Sept 2021
Amount
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and directed.
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and directed. Note : WPC and chicken wire gauge will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and directed. Make : Pidilite/Sika
M & L Preparing New Surfaces of Walls and applying two coats of cement base paint complete all as specified and directed.
Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder complete all as specified and directed.
Applying wall care putty on walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring of size 580 x 580 mm each & 18-20 mm thick, set and jointed in cement slurry including border of 100mm wide baroda green/white mable as per pattern approved over & including screed of 20-22 mm thick in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed. Note : 1. All the edges of slabs shall be grinded/cutted at the right angle before laying, so that paper thin, smooth jointing to be obtained. 2. The colour of the slabs shall be uniform.
M&L for machine cut kota stone slab as in skirting of 18-20 mm thick, set and jointed in cement slurry over & including screed of 10 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified and directed.
Dismantling loose/disintegrated portion of RCC Chajjas, bands, shelves, beams, column or slab and similar work including support if required and stitching of cracks with MS U clamps of 8mm dia @ 150mm c/c with inserting concrete block strecthner with cement mortar 1:3 mixed with adhesive chemical (polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with 10mm thick plastering in CM 1:4 finished even & smooth without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Dismantling of asbetos/fibre cement corrugated/semi corrugated sheet in roof covering including ‘J’ or ‘L’hooks complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified Note : Fixing of sheets will be done strictly according as per manufacurer's instructions. Make : Tata Bluescope or equivalent as approved by AO
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F false ceiling of 12.5mm th gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer's instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by AO and including supply and fixing of items all as specified as below :- Note : The complete item shall be got executed through the authorised applicator of manufacturer only all as specified and directed. Make : Gyproc or equivalent as approved by AO
(a) S&F Suspended Plain Ceiling includes Perimeter Channel {Material-GI(IS513),YS-260Mpa, Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres. Make : Gypserra™ (b) S&F Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid. Make : Gypserra™ (c) S&F Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} Make : Gypserra™ (d) S&F Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c. Make : Gypserra™ (e) S&F Single layer of 12.5mm tapered edge Plain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. Make : Gypboard® (f) Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape. Make : Gyproc®
Demolition of RCC as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed.
M&L for RCC M-25 (20mm graded aggregates) Design mix in slabs supported on walls, beams and columns in floors, roofs, landing, balconies, canopies deck slabs and in shelves and the like complete all as specified and directed.
M&L for Form work to soffits of suspended slabs such as roof slabs not exc 200mm thick horizontal for flat roofs complete all as specified and directed.
S&F mild steel TMT bars but 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for cement plastering 5mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying acrylic thick wall care putty on internal surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.
Demolition of mud phuska on roof any thickness complete all as specified and directed.
Scarping surfaces of roof by wire brushing and removing all loose dust and cleaning and washing down the surfaces with water complete all as directed.
M&L for PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregates as in padding over roof, minimum thickenss at khurra as 25 mm to maintain a slope of 1:100, complete all as specified and directed.
M&L for Rendering 20 mm thick on top of roof in CM 1:4 incl mixed with WPC (Water proofing compound shall be paid separetly).
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
Applying membrane on primed surface by press application method with minimum 75 mm longitudinal wise lap and 100 mm over lap on the transverse direction duly sticked using 3 mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished non woven polyester reinforced (wt not less than 150 grams) over applying one coat of bituminous primer @ 0.4 kg per Sqm complete all as specified and directed.
M & L 22mm thick PCC tiles laid over cement mortar 1:3 mixed with water proofing compound and joints grouted flush in cement mortar (1:3) complete all as specified and directed. Note : WPC will be measured and paid for seprately.
M & L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in roof kerbs, benches and water troughs etc. including necessary moulding complete all as specified & directed.
S&F doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 500 Ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified.
Taking down of PVC water storage tank of any size/description/position located on terrace of the building all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
S&F powder coated sliding aluminium glazing/ doors & shutters made out of aluminium anodised section suitable for sliding shutter type & shutters made of size 81.25x38.10x1.75mm for side rails, top rails and bottom rails and including 5mm thick forsted glass above middle rail and below 5mm thick ACP sheet including EPDM gasket to render the glazing, air and water tight etc. & aluminium beads 20mm size and incl mortice lock with duplicate keys etc complete all as specified and directed by Engr-in-Charge including supply and fixing the following items: (a) Powder Coated Aluminium Butt Hinges 100mm - 3 nos per leaf (b) Powder Coated Aluminium Tower Bolt 200mm long - 2 nos per leaf (c) Powder Coated Aluminium Handles 150 mm - 2 nos per leaf
S&F powder coated aluminium glazing/ doors & shutters made out of aluminium anodised section 101.60x44.75x1.75mm for chowkats or frame & shutters made of size 81.25x38.10x1.75mm for side rails, top rails and bottom rails and including 12mm thick High Density Fibre Board pre-laminated on both sides (water proof) above and below middle/lock rail, and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including required nos. of pivots/hinges complete all as specified and directed by Engr-in-Charge including supply and fixing the following items: (a) Powder Coated Aluminium Butt Hinges 100mm - 3 nos per leaf (b) Powder Coated Aluminium Tower Bolt 200mm long - 2 nos per leaf (c) Powder Coated Aluminium Handles 150 mm - 2 nos per leaf
Taking down eaves, gutters and rain water pipes (any sizes or pattern) incl all fitting incl cleaning for refixing or removing to store yard.
S & F 150mm dia PVC(SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls with and including holder bat clamps made out of 40mm by 3mm FI and 12mm dia round iron stays and making good the disturbed portion in CM 1:3 to match with surrounding area, complete all as specified and directed
S & F PVC(SWR) bends for 150mm dia rain water pipes with rubber ring joints complete all as specified and directed
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M & L for point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core stranded copper conductor for one light/fan and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) MAKE:Plaza, finolex,polycab,havells,gloster.
All as per Sl item No 2 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed. MAKE:Plazafinolex,polycab,havells,gloster.
All as per Sl item No 2 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed. MAKE:Plaza, finolex,polycab,havells,gloster.
All as per Sl item No 2 above herein before but one socket out let 3 pin 15 Amp Independent with 2.5 sqmm wire including 1.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete all as specified and directed. MAKE:Plaza, finolex,polycab,havells,gloster.
S& F Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed. Make: Legrand-arteor/Indoasian-Elvira/Schneider-zencello
S & F Modular switch 1 way, 16 Amps, 1 module complete all as specified and directed. Make: Legrand-arteor/Indoasian-Elvira/Schneider-zencello
S & F Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed. Make: Legrand-arteor/Indoasian-Elvira/Schneider-zencello
S & F Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
S & F fan regulator modular type 2 module complete all as specified and directed.
Metal flush boxes mounting 1 module, made of MS chromium plated complete all as specified
Metal flush boxes mounting 8 module, made of MS chromium plated complete all as specified and directed.
Metal flush boxes mounting 3 module, made of MS chromium plated complete all as specified and directed.
Metal flush boxes mounting 6 module, made of MS chromium plated complete all as specified and directed.
Modular cover plate frame, 1 module complete all as specified and directed.
Modular cover plate frame, 8 module complete all as specified and directed.
Modular cover plate frame, 3 module complete all as specified and directed. Make: Legrand-arteor/Indoasian-Elvira/Schneider-zencello
Modular cover plate frame, 6 module complete all as specified and directed. Make: Legrand-arteor/Indoasian-Elvira/Schneider-zencello
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed. Make:Plaza,Havells,SSK.
S & F Lamp holder incl flexible wire 0.5 Sqmm copper cable all as specified & directed. Make:Havells,Plaza
Supply and fix tube light fitting LED type retrofit T-8,20 watt,4 ft long incl LED tube rod and incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed.
supply and fix tube light fitting LED type integrated 9/10 watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed.
supply and fix bulk head fitting LED type incl 1 x 9/10 watt LED lamp,with flexible wire 0.5 sqmm copper cable all as specified & directed. Note: Bulk head fitting will be issue from store yard of MES.
Supply and fix building security light 25 w led complete all as specified and directed.
Supply and fix ceiling light 2 ft x 2 ft 36 watt led complete all as specified and directed.
S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP42 protection complete all as specefied and directed. Make:Schenider,Seimens,Legrand
S&F MCB , SPN, 240 Volt , 40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. Make:Schenider,Seimens,Legrand.
S&F MCB, single pole 240 volts 6 to 32 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. Make:- Indo Asian,standard, havells,Schenider,Seimens,Legrand
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRls ,stranded copper conductor cable drawn through metallic concealed conduit 25 mm dia incl 4.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. MAKE: Kalinga, finolex,polycab,havells,gloster.
M&L for sub main wiring with four single core 10 Sqmm PVC insulated and unsheathed FRls ,stranded copper conductor cable drawn through metallic concealed conduit 25 mm dia incl 6 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. MAKE: Kalinga, finolex,polycab,havells,gloster.
Taking down ceiling fan and refixing after neccery cleaning complete all as specified and directed.
S&F sheet metal factory made box of size 50x50x18 cm flush mounting type proper locking arrangement apply two coat of syntetic enamel paint drilling holes for incoming and out going cable refixing electric meter and DB complete all as specified and directed.
S&F earth metal plug with MCB SPN 32 amp complete all as specified and directed.
S&F MCCB TPN,4 Pole,415 volts,100 amp, 16 KA rupturing capacity for fixing in DBs of including proper thimble connections complete all as specefied and directed. Make:Schenider,Seimens,Legrand
S&F MCCB DB TPN 4ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete with IP-42 all as specified and directed. Make:Schenider,Seimens,Legrand
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, charcoal and common salt mixed refilling of soil etc complete all as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out as directed.
Returing, filling in, including spreading excavated soil, leveling, watering and well ramming in layers not exceeding 25 cm thick each complete as specified and directed.
Removing excavated surplus spoil obtained from excavation to a distance not exceeding 50 mtr and depositing where direct as a level not exceeding 1.5mtr above the starting point complete all as specified and directed .
Sand cushioning for laying cable all as specified and directed
Supply and laying in trenches in bricks sub class 'B' old size burnt brick for cable protection complete all as specified and directed .
PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundations as mass concrete for poles, struct, stays etc including necssary form work and finishing the surface fair and even without using extra cement complete all as specified and directed .
M &L GI pipe light grade 50mm bore for road crossing/ along the poles for cable protection complete all as specified and directed .
M/S Mukesh Kumar Gupta
Buttar Construction Co.
Vipin Kumar and Brother
Arneja Builders
NORTON BUILDER
AR CONSTRUCTIONS
Swami Engineers
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .