Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.6 L+₹36,864 (1.66%)Rejected-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹52.3 L+₹30.0 L (134.9%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
25 Oct 2022, 6:00 pmClosed
Garrison Engineer, St.Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS/MAINT OF REFRIGERATORS, WATER COOLERS, WINDOW, SPLIT AC ETC AT OTA, MH AND PALLAVARAM UNDER GE STM
2022_MES_554472_1
8320-REPAIRS/MAINT OF REFRIGERATORS, WATER COOLERS
Open Tender
Civil Works - Others
Item Rate
270 days
GE STM
As per tender documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹50,000
Yes
3 Dec 2022
27 Sept 2022
2 Nov 2022
27 Sept 2022
25 Oct 2022
11 Oct 2022
27 Sept 2022 - 5 Oct 2022
Amount
Taking down unserviceable items Supply and replacing with new items of following for water cooler 40/40 ltrs, 40/80 ltrs and 150/150 ltrs capacity including testing and commissioning etc complete all as specified and directed.
(a) Thermostat Make : Indfoss/Danfoss/Ranutrol/Electrolux
(b) Capacitor 36 MFD Make : Keil/Keltron/saha/sarold
(c) Capacitor 10 MFD Make : Keil/Keltron/saha/sarold
(d) Over load protector. Make : Ranutrol/Arvind/Shriram
(e) Fan motor capacitor 4/6 MFD Make : Keil/Keltron/saha/sarold.
(f) Condenser fan motor 1/32 HP. Make : Frog master/Aue/Himson
(g) Condenser fan motor 1/16 HP. Make : Frog master/Aue/Himson
(h) Fan blade assembly.
(i) PVC drain hose pipe size 32 mm dia
(j) Drain stainless steel tray with drain elbow and connector
(k) Top lid gasket
(l) PVC connections 15mm size with PTMT nuts of length 450mm
(m) Gate valve brass screwed both ends of size 15mm bore.
(n) Push cock brass chromium plated size 15mm.
(o) Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed of size 15mm.
M&L for servicing the water coolers of any make and models in situ, comprising cleaning of condensers and storage tanks with cleansing agent such as liquid detergent, lubricating the system with grease or oil as required tightening the bolts nuts etc complete all as specified and as directed.
(a) 40/80 ltrs capacity
(b) 150/150 ltrs capacity
All as per item No. 2, but for refrigerator 165 to 310 ltrs capacity.
(a) Door magnetic gasket
(b) Freezer door
(c) door lock with key
(d) Light switch
(e) PVC ice tray (Each set of two nos)
(f) Cooling coil
(g) Condenser coil
(h) Bulb pin/screw type 10/15watt. Make : Philips or equivalent
(j) 3 pin15amps plug top 240 volts
(k) Relay box type. Make : Ranutrol/Arvind/Shriram
(l) Relay 1/6HP Make : Ranutrol/Arvind/Shriram
(m) Over load protector 1/6HP. Make : Ranutrol/Arvind/Shriram.
(n) Thermostat defrosting type Make : Indfoss/Arvind/Shriram
(o) Defrost tray for Refrigerator Capacity 165 to 330 Ltr Make Suitable for Whirlpool/LG/Samsung/Godrej
All as per item No 2 but for Window / split type AC 1.5/2.0 Ton capacity
(a) Capacitor 50-60 MFD , Make: Keil/Keltron/saha/sarold
(b) Overload protector (OLP). Make : Ranutrol/Arvind/Shriram.
(c) Starting relay assembly . Make: Ranutrol/Arvind/Shriram
(d) Electronic PCB Board for non inverter AC
(e) Electronic PCB Board for inverter AC
(f) Wiring kit complete
(g) Fan motor capacitor 2-5 MFD. Make: Keil/Keltron/saha/sarold
(h) Outdoor unit Fan motor . Make : Frog master/Aue/Himson
(i) Condenser Fan blade metal or plastic
(j) Indoor unit blower motor.
(k) Indoor unit blower
(l) Cooling coil copper.
(m) Condenser coil copper.
(n) Standard outer cover
(0) Front panel with grill
(p) Copper pipe for suction and discharge line
(q) Drain pipe
(r) Thermostat Switch (Make : Shriram/Ranutrol/Arvind)
(s) Air filter
(t) Complete indoor unit set for split AC as per existing make.
(t) Complete outdoor unit set for split AC without compressor and fan motor as per existing make.
(u) Capillary and filter
(v) Suction valve for split AC
(w) Discharge valve for split AC
(x) Outdoor unit wall stand
(y) Regulator Knob Suitable for 1.5 TR/ 2.0 TR capacity window AC
(z) Remote control including battery for window / Split AC Cap 1.5/2.0 TR of make as per site requirement and replace of Old one complete all as specified and as directed (Make -LG/ Bluer Star/ Voltas)
(ab) Foam sheet of size 180 cm X 90 cm X 15mm thick complete all as specified and as directed
(ac) Hexagonal Flare nut made of Brass
(ad) Union Couple made of Brass
(ae) inverter type PCB circuit plate with sensors suitable for Outdoor unit of Split Aces of any Capacity
(af) inverter type PCB circuit plate with sensors suitable for Outdoor unit of Split Aces of any Capacity
(af) Swing Motor suitable for indoor unit of inverter type Split Aces of any Capacity
Dismantling the unserviceable sealed compressor unit from 1.5 TR Window AC / Split AC of any make and model, supply and fixing new sealed compressor unit including, connecting up complete and oil charging, etc., all as specified and directed Note: Refrigerant gas charged shall be measured under relevant item of Sch 'A' Make : Tecumseh/Hitachi/Panasonic/Highly.
All as per item No. 5 above but for Window /Split AC 2.0 TR capacity.
All as per item No 5 above but for Water cooler 40/80 ltrs capacity.
All as per item No 5 above but for Water cooler 150/150 ltrs capacity.
All as per item No 5 above but for Refrigerator 165 ltrs capacity.
All as per item No 5 above but for Refrigerator 286 to 310 ltrs capacity.
All as per item No 5 above but for Deep freezer 300 to 425 ltrs capacity.
M&L for pressure testing the Window ACs 1.5 Ton, with nitrogen gas after flushing out the system free from refrigerant checking for leakages if any in the refrigerant system making good the leaking spots with necessary brazing/welding, ensuring leak proof system charging the refrigerant gas including replacing the strainer & capillary etc with new items and testing for satisfactory performance complete all as specified and as directed. Note: Refrigerant gas charged shall be measured under relevant item of Sch 'A'
All as per item no 12 above but for Split AC 1.5/2.0 TR capacity
All as per item no 12 above but for Water cooler 40/80 ltrs & 150 ltrs capacity
Leak testing and gas charging the system after flushing, vaccumissing and dehydration as per standard practice including the cost of refrigerant, testing and detecting leakage in the system and arresting the same for 165 to 310 ltrs capacity of the refrigerator
Dismantling of existing repairable Refrigerators of any make and from its position after disconnecting electric connections transporting from site to Contractor workshop for carrying out repairs and renewal/ replacement of parts, reassembling and transporting back to the site including installation of the same on the Same Location and making electric connection etc complete all as specified and as directed. Note:- parts renewed shall be measured and paid separately
Supply and filling Refrigerant gas R-134 A in Refrigerators ?deep Freezers /Water Coolers of any Capacity, Model and make including detecting the leakage Gas at any Location and rectifying the defect to stop the Leakage by Gas welding or by other means including cutting and Brazing of copper tubes testing and commissioning complete in satisfactory working condition Make: Melfron/Floron/Refron
Material and Labour for cleaning filter and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out and fixing back its original position combing the fins for Window type Air conditioner 1.5 Ton/2.0Ton Capacity complete all as specified and as directed.
Material and Labour for cleaning filter and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out and fixing back its original position combing the fins for Split type Air conditioner 1.5 Ton/2.0Ton Capacity complete all as specified and as directed.
Disconnection and removing of serviceable window type AC of capacity 1.5TR/2.0TR of any make / Model along with Stabilizer from its position and fixing the same in other Location including all other fixing accessories and testing complete all as specified and as directed.
Disconnection and removing of serviceable Split type AC of capacity 1.5TR/2.0TR of any make / Model along with Stabilizer from its position and fixing the same in other Location including all other fixing accessories and testing complete all as specified and as directed.
Disconnecting and taking out deep freezer of capacity 300 litre to 425 litre of any make, cleaning the gas system with CTC / nitrogen and charging the refrigerant including the cost of refrigerant with anti moist substance and replacement of capillary tube and strainer including rectification of leakage in the system and refixing in the same position complete all as specified and directed.
Material and Labour for detecting of leakages of gases in water cooler , Refrigerator of any capacity at any Location and rectifying the defect to stop the Leakage by Gas welding or by other means including cutting and Brazing of copper tubes testing and commissioning complete in satisfactory working condition
Taking down existing worn out winding from fan motor , rewinding the blower fan motor of window / Split AC capacity of 1.5 TR with super enamelled copper wire of suitable gauge capacity, bringing back to worksite and refixing the same on its position including replacement of bushes all as directed.
All as per item no.24 above but for Water cooler 40/80 and 150/150 ltrs capacity.
Taking out of all rusted portion of Window AC ,making good the same with new MS sheet of approved gauge /existing gauge including iron supports by tinkering/welding and positioning back in original place including two anticorrosive black paint over a coat of primer all as specified as directed.
All as per item no 26 above but for Water cooler 40/80 & 150/150 ltrs capacity.
All as per item no 26 above but for Refrigerator 165 to 310 ltrs capacity.
Material and labour for applying two coats of anti corrosive black paint upto 15 cm height of old steel surfaces from the base all round including legs for inside of water cooler of capacity 150 ltrs all as directed
All as per item no 29 above but water cooler capacity 40/80 ltr
Supply and filling of gas R-22/R-410A/R-32/R-134A in window type/ Split Type AC Unit of Capacity 1.5/ 2 TR Deep Freezer, Refrigerator , Water Cooler of any Capacity Complete all as specified and as directed. Make: Melfron/Floron/Refron
Supply and fix new MS bottom base for fan motor of any given make for window type AC 1.5 tonne including dismantling the old unserviceable fan motor base all as directed
Supply and fix MS jointing plate for condenser / cooling coil housing for window AC of any make for 1.5 Ton capacity including dismantling the old unserviceable jointing plate all as directed.
Supply and fix ply wood 6mm thick , no of ply 6, grade BWR, type BB at the window AC places as fixed with nails etc and when the AC removed from site as a safety measure all as directed
Dismantling the transformer from the stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer as per existing make.
Replacement of following spare parts as per existing make for 1 KVA to 2 KVA capacity stabilizers
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Replacement of following spare parts as per existing make for 4 KVA to 5 KVA capacity stabilizers
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
(c ) Trigger Transformer of 500 MA to 750 MA Capacity suitable for 5 KVA voltage Stabilizer , 1 ph, 230 Volts
(d) Indicator Lamp , Red or Green Colour as required round shape suitable for 5 KVA voltage Stabilizer , 1 ph, 230 Volts
(e) Analogue type Voltmeter 0-300 Volts round or square shaped suitable for 5 KVA voltage Stabilizer , 1 ph, 230 Volts
(f) Digital type Voltmeter 0-300 Volts round or square shaped suitable for 5 KVA voltage Stabilizer , 1 ph, 230 Volts
(g) Relay of 30 Ampere capacity suitable for 5 KVA Voltage stabilizer , 1 ph, 230 Volts
M&L for rewinding of Main Transformer of 5 KVA Capacity voltage stabilizer with super enamelled copper wire of suitable size with including necessary varnishing and heating complete all as specified and as directed
Cold storage/Package type / Walk in cooler plants of capacity 5/5.5 try
Material and labour for cleaning filter, drain out pipe and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out including combing the fins for cold storage unit 5/5.5TR all as specified and as directed
Material and labour for cleaning filter, drain out pipe and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out including combing the fins for Package Type AC Unit 5/5.5TR all as specified and as directed
Material and labour for cleaning filter, drain out pipe and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out including combing the fins and replacement of minor parts as required for mortuary cabinet all as specified and as directed
M&L for Descaling of condenser unit 5.5 TR by circulating dilute hydrochloric acid solution and cleaning the tubes with wire brush by removing the side cover till the tubes are thoroughly cleaned and re-circulating the fresh water after fixing the side cover with necessary gasket and bolt and nuts.
Labour charge only for attending breakdown of cold storage/ mortuary cabinet and make it functional all as directed. Note : Spares shall be measured and paid separately.
Labour charge only for attending breakdown of Package Type AC and make it functional all as directed. Note : Spares shall be measured and paid separately.
Removing the defective sealed type compressor from the of cold storage AC plant/package type AC plant, supply and fix new sealed compressor including reconnecting and testing and commissioning at site all a specified and directed. Make : Tecumseh/Hitachi/Panasonic/Highly.
Testing leak in system, arresting leak, vacumising the system, flush out the system by nitrogen gas at 350 psi vacumising and testing and commissioning complete for 5/5.5TR capacity walk in cooler / cold storage / package type plants all as specified and directed. Note: Refrigerant gas charged shall be measured under relevant item of Sch 'A' as above
Replacement of electronic timer series ETR-350,240v AC 50/60 HZ Contact 240v AC/28VDC 5 A (Resistive) Star-Delta 3.30 second and 6-60 second cat No. Y 847D-1 Make : L&T or equivalent make
Replacement of single phase preventer. Make:- Minilac or equivalent.
Supply and fix orifice No 4 as per existing make for walk in cooler all as directed
Replacement of expansion valve for cold storage plant 5/ 5.5TR Make : Sporlan or equivalent
Replacement of condenser fan motor with blower set blade of 5 / 5.5TR capacity for cold storage all as directed. Make : Frog master/Aue/Himson
Replacement of LP and HP Cut out for cold storage plant 5 / 5.5TR Make : Indfoss or equivalent
Supply and fix for gasket entire door of walk in cooler capacity of 5.5 TR etc complete all as speci fied and as directed.
Supply and fix evaporator fan motor for walk in cooler capacity 5.5 TR complete all as specified and as directed. Make : Frog master/Aue/Himson
Supply and replacement of pillar block bearing for AHU blower motor of package type 5.5 TR capacity air conditioning all as directed. Make:- SKF/ABC/TATA.
Supply and replacement of liquid line filters, driers Type IDK 083 as per existing make of package type 5.5 TR capacity air conditioning all as directed
Supply and replacement of 'V' belt for blower of package type AC plant Make: Fenner, Cat Part No A 32 or equivalent
Supply and replacement of fan blade as per existing make heavy duty suitable for package type AC plant 5.5 TR
Replacement of suction valve unit for cold storage plant / Package Type AC Plant 5 / 5.5TR
Replacement of discharge valve unit as per existing make for cold storage plant / Package type AC Plant 5/ 5.5TR
Replacement of evaporator coil for fan motor complete with blade set suitable for cold storage plant/ Package type AC Plant 5 / 5.5TR. Frog master/Aue/Himson
Replacement of service valve Model scroll type Unit as per existing make for cold storage plant/ Package type AC Plant 5/ 5.5TR
Replacement of copper pipe 5/8" suitable for 5.5 Ton capacity sealed compressor of cold storage plant/ Package Type AC Plant of 5.5TR
Replacement of UNSV door lock and assembly for cold storage plant Make :- Blue Star of 5.5TR or suitable to existing one
Supply and replacement of condenser fan motor Make: GE or equivalent for package type AC plant 5 / 5.5TR
Replacement of thermostat for cold storage plant/ Package type AC Plant 5/ 5.5TR
Replacement of Air break (Power) contactor 3 TF 3200-OA AC 11 rating -16 Amps capacity Make : SIEMENS or equivalent
Material and labour for rewiring of control panel complete, providing inter lock system and serving of electronic PCB Board and display for package type AC plant Existing Make : Blue star 5 / 5.5TR
Supply and replacement of drier core for package type A/C plant 5 / 5.5TR. Existing Make Danfoss
Supply and replacement of starting relay 30 W of range 3.5 to 5 Amps. Make: Siemens or equivalent
Replacement of solenoid valve and cut-out switch with N2 testing for cold storage / package type 5/ 5.5 TR capacity air conditioning all as directed. Make : Danfoss or equivalent
Taking down old U/S copper wire and supply & fix three core flexible cord copper wire size 3 core 4 sqmm suitable for window type AC/split AC/water cooler etc complete all as specified and as directed.
Supply and fix Temperature controller assemble for cold storage plant/ Package type AC Plant 5.5 TR as per existing make.
Supply and fix MCB SP 06-32 Amps "C" Series. Make Standard/Havells/Indoasian
Supply and fix of water flow switches as per existing make of package type 5.5 TR capacity air conditioning etc complete all as specified and as directed.
Supply and fix dryer as per existing make 5/8 for walk in cooler capacity 5.5 TR complete all as specified
Supply and replace electronic control unit with display board for 5.5 TR package type AC and make the system functional all as directed.
Supply and fix PVC FR insulated copper wire single core, 1100volts, 10 sqmm size. Make : Finolex/Havells/Plaza.
M&L for Rigid non metallic PVC conduit of size 25mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tub ends and fixing accessories such as couples, lock nuts, saddle, pipe hooks in concealed position and making good disturbed surface etc.
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown of size 65 mm dia.
Replacement of MS flange having holes suitable for 65MM sizes of pipe including jointing material such as rubber gasket bolt units and washers etc in place of unserviceable all as directed
S&F rolled mild steel work in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc., cut to within 20mm of the length indicated, quality confirming to GDE Fe-410-S for cooling tower repair and pump mounting base complete all as specified and as directed.
Painting of cooling tower inner side and outer side one coating of Red oxide two coating of existing colour of synthetic enamel paint after cleaning and scrubbing of capacity 22TR.
Replacement of PVC honey comb fills (drift eliminators) suitable size of 22 TR plant all as specified and directed.
Servicing of LT AC plant panel board of any size including connected starter panels and wirings, cleaning of panel board internally and externally, tightening of all screws and nut & bolts, replacing of minor parts like screws, washers, lugs etc, checking of serviceability of all switch gears
Replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter. Make L & T or equivalent
Replacement of MNX 18 W contactor assy AC - 3 415 V 16 Amps . Make L & T or equivalent
Replacement of MNX 18 W contactor assy AC - 3 415 V 16 Amps . Make L & T or equivalent
S&F MCB TPN 20 Amps 415 volts with rupturing capacity 10 KA Make Havells or equivalent
S&F MCCB 3 pole 100A Amps 415 volts Fixed type with breaking capacity 16 KA
Supply and replace 3 Phase Flush Mounting Ammeter, Class 1 meter, 96X96 mm 3 Ph 4W 240V 5A Make : L&T /AE/Legrand.
Supply and replace 3 Phase Flush Mounting Voltmeter, Class 1 meter, 96X96 mm 3 Ph 4W 240V 5A Make :L&T /AE/Legrand.
Supply and replace standard universal LED indicators of colour RYB. Make: L&T /AE/Legrand.
Supply and fix MCB single pole 6-32 A, 230 volts, C series . Make : Havells /Indo Asian/ Legrand.
Dismantling the mono block pump set 3 HP with motor rewinding the motor with suitable enamelled copper wire, varnishing, providing sleeves and insulating materials including servicing of pump, repairing the defective spares and assembling and testing
Dismantling the Induction motor for AHU rewinding the motor with suitable enamelled copper wire, varnishing, providing sleeves and insulating materials including repairing the defective spares and assembling and testing
Painting of mono block pump set with motor of any capacity with two coats of synthetic enamel paint after cleaning and scrubbing.
S&F in replacement butterfly valve 65mm dia with handle
Supply and replace air filter suitable for 5.5 TR package type AC with frame all as specified and directed.
Painting of condenser pipe line inlet and outlet( length upto cooling tower basin) and chillier pump pipe line inlet and outlet(length up to plant room wall) one coating of existing colour of synthetic enamel paint after cleaning and scrubbing including marking and numbering complete all as specified and directed .
Dismantling and fixing the cooling tower service panel and drain out complete water cleaning of honey comb fills, drift eliminators, Nozzles by caustic soda and wire brush and cleaning the cooling tower tank and removed all algae from the basin and removing sediments from the GI pipes and cleaning the sump suction filter of capacity 22 TR
Supply and fix single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with and including single pole MCB 20 Amps. Make Standard/Havells/Indoasian
Servicing of Air Curtain of size 6' (Existing Make : Almonard), cleaning internally and externally, tightening of all screws and nut & bolts, replacing of minor parts like screws, washers, etc, including replacement of bush, checking of serviceability of all components. Note : Service shall be done through authorised service provider only.
Supply and replace motor single phase 4 pole, 1/5 HP.
Supply and replace Impeller metal bush.
Supply and replace Impeller pin bush.
Supply and replace Bush bearing set.
Supply and replace AS-3 smart Impeller.
S&F Rotational moulded polyethylene water storage tank (3 layered, cylindrical vertical with closed top) ISI marked, hoisted and fixed in position of capacity 5000 ltrs all as directed and specified. Make: Sintex/Ceat/Plasto/Polycon
Supply and Laying in replacement of Rubber mat of size 1 meter x 2 meter x 10 mm complete all as Specified and directed
Supply and fix GI Pipe medium grade of 25 mm dia with all fittings such as union, elbows tee , bend etc laid on wall/ ceiling complete all as specified and directed
Supply and fix GI Pipe medium grade of 40 mm dia with all fittings such as union, elbows tee , bend etc laid on wall/ ceiling complete all as specified and directed
General Notes for Srl item No.01 to 113 : 1. Repairs will be notified as complaints at complaint cell of GE STM Chennai. Complaints will be attended in all working days, holidays including Sundays. 2. The contractor shall report or shall deploy one rep or supervisor on all working days to report in the complaint cell by 0900 Hrs to receive the complaints. 3. Complaint slip should be submitted in the complaint cell by evening 1700 Hrs duly rectified the defect. 4. The rate quoted is deemed to include for receiving complaints, all materials and labour required for rectification of complaints and closing the complaints to the satisfaction of Engr-in-Charge/ GE.
RK ENTERPRISES
EVEREST ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .