Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5.2 L
Closing Date
25 Nov 2026, 4:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
15 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows:
The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.[Ref:- GCC April 2022 Para 10.1 of Tender Form (Second Sheet) of Annexure I of ITT. Further 'Explanation for Para 10 of the Tender Form (Second Sheet) including Para 10.1 to 10.5 - Eligibility Criteria' shall be as per GCC April 2022].
Defination of Similar Work :- Any work involving outdoor or Indoor signalling work. Signalling work-All works which are directly related to the interlocking of the core Signaling System. OR Any MACLS work involving outdoor & indoor work or alteration in existing Indoor/outdoor signaling system. OR Any work involving outdoor/indoor signalling works including MACLS/EI/PI/RRI/IBS/IBH/LC Gate/DAC/ELD and ELD for Signalling Cable, Quad Cable, Fuse Auto Changeover system etc.
48 conditions · 1 needing a document upload
The bidder has to submit the Annexures attached with tender:- I/A,I/B,II, III,IV/A,IV/B , tender first Sheet duly fill-up and signed (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Mode of Payment from Railway through a "Letter of Credit(LC)" arrangement. If yes, attach beneficiary Bank details. Details available in Special condition.
The Balance Sheet and all other Financial documents attested/certified by the Chartered Accountant (CA) to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN failing which the offer shall be considered as incomplete and will be summarily rejected without any further reference.
(Special Condition of Contract for mandatory updating of Labour data on Railway's shramikkalyan portal by Contractor (Ref:- Railway Board letter no.-2018/CE-I/CT/4, Dated 17.10.2018.)
A. Contractor is to abide by the provisions of Payment of Wages act &Minimum Wages act in terms ofclause 54 and 55 of Indian Railway GeneralCondition of Contract. In order to ensure the same, anapplication has beendeveloped and hosted on websitewww.shramikkalyan.indianraihwars.gov.in'.Contractor shall register his firm/company etc. and uploadrequisite details oflabour and their payment in this portal. These details shall be available inpublicdomain. The Registration' updation of Portal shall be done as under:(a) Contractor shall apply for onetime registration of his company/firm etc. inthe Shramikkalyan portal with requisite details subsequent toissue of Letter ofacceptance. Engineer shall approve the contractor's registration within 7 daysof receiptof such request. (b)Contractor once approved by any Engineer, cancreate password with login ID (PANNo.) for subsequent use of portal for allLOAs issued in his favour. (c) The contractor once registered onthe portal,shall provide details of his Letter of Acceptances (LOA)/Contract Agreementson shranikkalyanportal within 15 days of issue of any LOA For approval ofconcerned engineer. Engineer shall update (ifrequired) and approve thedetails of LOA filled by contractor within 7 days of receipt of such request.(d)After approval of LOA by Engineer, contractor shall fill the salient details ofcontract laboures engagedin the contract and ensure updating of each wagepayment to them on shramikkalyan portal on monthlybasis. (e) It shall bemandatory upon the contractor to ensure correct and promt uploading of allsalientdetails of engaged contractual labour & payment made thereof aftereach wage period. B. Whileprocessing payment of any 'ON account bill' or'Final bill' or relese of 'Advance ' or 'PerformanceGuarantee/Security deposit' contractor shall submit a certificate to the Engineer orEngineer'srepresentative that " I have uploaded the correct details of contract laboursengaged inconnection with this contract and payment made to them during the wage period in Railway'sShramikkalan portal at www.shramikkalyan.indianrailways.gov.in till _____, month,______ Year.".
Special Conditions for inclusion of 'Letter of Credit' as Mode of Payment in works Tender or Service tender. (Authority: - Railway Bd. letter no.2018/CE-I/CT/9, dated: 04.06.2018).
For all the tenders having advertised cost of Rs.10 lakh or above, the contractor shall have the option to take payment from Railways through a letter of credit (LC) arrangement.
This option of taking payment through LC arrangement has to be exercised in IREPS (Indian Railway Electronic Procurement System - the e-application on which tenders are called by Railways) by the tenderer at the time of bidding itself, and the tenderer shall affirm having read over and agreed to the terms and conditions of the LC option.
The option so exercised, shall be an integral part of the bidder's offer.
The above option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract.
In case tenderer opts for payment through LC, following shall be the procedure to deal release of payment through LC:
The LC shall be a sight LC.
The contractor shall select his Advising/Negotiating bank for LC. The incidental cost towards issue of LC and its operation thereof shall be borne by the contractor.
SBI, New Delhi, Main Branch will be the nodal branch for issue of LCs based on online requests received from Railway Accounts Units for tenders opened in financial year 2018-19. SBI branches where the respective Railway Accounts Office has its Account (local SBI branch) will be the issuance/reimbursing branch for LC issued under this arrangement. The Bank shall remain same for this tender till completion of contract. The incidental cost @ 0.15% per annum of LC value, towards issue of LC and operation thereof shall be borne by the contractor and shall be recovered from his bills.
The LC shall be opened initially for duration of 180 to 365 days in consultation with contractor. The LC shall be extended time to time as per the progress of the contract, on the request of the contractor. The value of LC to be opened initially as well as extended thereafter shall be finalised by the engineer in consultation with the contractor on the basis of expected progress of work.
The LC terms and conditions shall inter-alia indemnify and save harmless the Railway from and against all losses, claims and demands of every nature and description brought or recovered against the Railways by reason of any act or omission of the contractor, his agents or employees, in relation to the Letter of Credit (LC). All sums payable/borne by Railways on this account shall be considered as reasonable compensation and paid by contractor.
The LC terms and conditions shall inter-alia provide that Railways will issue a Document of Authorisation (format enclosed as Annexure 2) after passing the bill for completed work, to enable contractor to claim the authorized amount from their bank.
The acceptable, agreed upon document for payments to be released under the LC shall be the Document of Authorisation.
The Document of Authorisation shall be issued by Railway Accounts Office against each bill passed by Railways.
On issuance of Document of Authorisation, a copy of Document of Authorisation shall be posted on IREPS for download by the contractor. A digitally signed copy of Document of Authorisation shall also be sent by Railway Accounts Office to Railway's bank (Local SBI Branch).
The contractor shall take print out of the Document of Authorisation available on IREPS and present his claim to his bank (advising Bank) for necessary payments as per LC terms and conditions. The claim shall comprise of copy of Document of Authorisation, Bill of Exchange and Bill.
3.5.11 The payment against LC shall be subject to verification from Railway's Bank (Local SBI Branch).
The contractor's bank (advising bank) shall submit the documents to the Railway's Bank (Local SBI Branch).
The Railway's bank (issuing bank) shall, after verifying the claim so received w.r.t. the digitally 3.5.13 signed Document of Authorisation received from Railway Accounts Office, release the payment to contractor's bank (advising bank) for crediting the same to contractor's account.
Any number of bills can be dealt within one L.C, provided the sum total of payments to contractor is within the amount for which LC has been opened.
The LC shall be closed after the release of final payment including PVC amount, if any, to the contractor.
The release of performance guarantee or security deposit shall be dealt directly by railway with 3.5.16 the contractor i.e., not through LC.
Payment Terms:
For Purely Supply Items:-90% of the value of each Supply Item of Schedule of Works will be Paid after supply of Items and on production of the following documents: - (i) Receipt of Material at Consignee's depot. (ii) Original inspection certificate / waiver of inspection issued by Inspecting Officer.(iii)Manufacturers' inspection certificate that the materials are in accordance with the specifications of the contract. Invoice in duplicate. A certificate that the materials supplied are as per the contract and the amount claimed in the invoice is correct as per terms of the contract. (vi) (a) Store receipt certificate issued by Railway official/Representative as per format as Annexure - R of existing Tender document(Copy enclosed). 5% percent payment for purely Supply Items against tender schedule of works will be made after successful commissioning of the Station. (b) The balance 5% percent payment for purely Supply Items against tender schedule of works will be made after Completion of Work, with Final Bill of the Contract.
For Purely Execution/Installation items: - 90% of the value of each Purely Installation Item of Schedule of Works will be paid after Installation & Testing of the Item. (a)5% percent payment for Purely Execution /Installation items against tender schedule of works will be made after successful commissioning of the station. (b)The balance 5% percent payment for purely Execution /Installation Items against tender schedule of works will be made after successful commissioning of the Station. Note: In case commissioning of station is delayed by more than 06 months on Railway Account and the physical work has been completed by the contractor in totality then 5% payment on account of commissioning of the station shall be released to the contractor.
For Supply & Installation items: - 90% percent payment for Supply &installation Items against tender schedule of works will be made after successful installation & testing and on production of the documents mentioned above in Para 1. on account bill shall be paid only on production of certificate by the site Engineer that relevant portion of installation has been completed. (a) 5% percent payment for Supply &Installation Items against tender schedule of works will be made after successful commissioning of the Station. (b)The balance 5%percent payment for supply & installation items against tender schedule of works will be made after completion of work with final bill of the contract.
All payments shall be made on the certificate of the Engineer within a reasonable time of the submission of the necessary bills by the contractor. Payment shall be made through cheques/NEFT/RTGS/LC payment in the name of the Contractor.
Scope of Work (i) "Rehabilitation and reliability improvement of S&T gears in Samastipur Division." (ii) Railway reserves the right to change, alter, add, or delete any site/location based on operational requirements, feasibility, availability of site, site conditions, or any other reason deemed necessary. (iii) The latest specifications and amendments thereto shall apply to all drawings and specifications. (iv) Technical Specifications, Inspection, Terms and Conditions: The detailed technical specifications, inspection requirements, term, and conditions for execution and supply shall be as per the tender document and applicable technical specifications (as applicable). Inspection for each item are specified in the schedule. However, for any safety item requiring Third-Party Inspection (TPI) by RDSO/RITES, shall be supplied with such TPI inspection, irrespective of the inspection agency mentioned in the schedule. (Inspection-Consignee, subject to total item value < 05 Lakh, Non safety critical items). TPI (RITES) inspection charge to be borne by contractor. Note: All the materials (schedule items) shall be supplied as per railway requirement. There should be no any compatibility/suitability issues for supplied materials to the existing/New equipment. (v) The work shall be executed and materials supplied as per the instructions of the site engineer. (vi) The quantities/items indicated in the schedule may vary according to Railway or site requirements. Railway reserves the right to change, alter, add, or delete any item or quantity at any stage of the contract. Railway does not guarantee execution of work under every item or the quantities specified in the schedule. (vii)The rates quoted by the tenderer shall include the cost of materials and all incidental charges, including transportation, loading, unloading, handling, and any other associated expenses. The quoted rates shall also include all applicable taxes (including GST), duties, royalties, levies, octroi, and other statutory charges (as applicable). (viii) Recovery of taxes from bills shall be made as per the extant rules in force. (ix) The contractor shall be responsible for the carriage, safe transportation, loading, unloading, storage, protection, and safe handling of all materials required for the execution of the work. (x) All relevant standard guidelines and instructions issued by Railway Board,HQ/East Central Railway regarding contract management, technical aspects/requirements, execution of work, and prevailing Railway practices, E. C. railway practice inforce etc. shall be apply in this contract (as applicable).
Transportation of Materials:-
All materials specifically supplied by contractor to be supplied to the SSE/Signal or Tele/Store/SPJ or as specified by competent authority.
Contractor will carry all the materials (contractor supplied) from SSE/Signal or Tele/Store/SPJ or as specified by Competent authority to the site of work at his own cost and arrangement.
Execution of AMC:- Not applicable.
Rehabilitation and reliability improvement of S&T gears in Samastipur Division.
SPJ-SnT-S-17-2026~ECR
SPJ-SnT-S-17-2026
Open
Works - General
12 Months
Samastipur, Bihar
₹0
₹5.2 L
3 Nov 2026
3 Nov 2026
11 Nov 2026
237 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,98,79,319.83 | ||
| — | 15000.00 | — | — | ||
| "Excavation of Trench in all kinds of soil and refilling oftrenches (1.2 Mtr, Depth, 300 mm Width) - without bricks.Note:-(I) Payment will be made as per actual work done on pro rata basis, if required depth is not available at site.(II) If the depth of trench is not uniform in a span of 100mtr.or shorter length, if site condition demands along thecable run minimum depth will be taken for that particular stretch for payment. " | — | — | — | 21,95,550 | |
| — | 15.00 | — | — | ||
| "Laying cables of different sizes as per cable route planapproved by Railway and meggering of all main & tail cablesas per technical specification of tender.2 core to 12 core signalling cable" | — | — | — | 1,76,353.8 | |
| — | 5.00 | — | — | ||
| "Laying cable of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender.Telecom Cable 5 Prs./10 Prs./Quad. " | — | — | — | 63,648.05 | |
| — | 250.00 | — | — | ||
| Reinstatement of platform and repairing to orginal state after cable laying work. | — | — | — | 99,905 | |
| — | 200.00 | — | — | ||
| "Supply of G.I. Pipe with threaded collars of 100 mm nominalbore specn. No. IS 1239 medium grade. Perforated of requiredlength on bridge / below metaled road/ L-xing /Culvert as pertechnical specification of tender.A) Supply portion for the G. I. Pipe & collars.Inspection by-Consignee" | — | — | — | 2,48,346 | |
| — | 200.00 | — | — | ||
| "Fixing of G.I. Pipe with threaded collars of 100 mm nominalbore specn. No. IS 1239 medium grade. Perforated of requiredlength on bridge / below metaled road/ L-xing /Culvert as per technical specification of tender.B) Execution with remaining miscellaneous materials." | — | — | — | 18,744 | |
| — | 400.00 | — | — | ||
| "Supply of PBT ARA terminal as per IRS SPECN No. IRS:S- 75-91i)6 way.Inspection by-RDSO" | — | — | — | 2,43,388 | |
| — | 10.00 | — | — | ||
| "Casting, Concreting and Curing of foundation and erection forfull apparatus case(GKP- type) as per DRG No.SGW/MGS/L1/91 including cost of all materials required forfixing holding down bolts, casting, concreting and fixing of""E"" type lock.Note :i) The contractor will provide holding down bolts, ii)Bottom of apparatus cases should be filled with sand and thetop surface covered with masonry work and neat cementing." | — | — | — | 71,312.7 | |
| — | 5.00 | — | — | ||
| "Casting, Concreting and Curing of foundation and erection forHalf apparatus case (GKP- type) as per DRG No.SGW/MGS/L1/91 including cost of all materials required forfixing holding down bolts, casting, concreting and fixing of""E"" type lock.Note: i) The contractor will provide holding down bolts,ii) Bottom of apparatus cases should be filled with sand andthe top surface covered with masonry work and neatcementing.." | — | — | — | 32,097.1 | |
| — | 10.00 | — | — | ||
| "Casting, concreting and curing of foundation for Main signaland as per DRG.No.SGW/MGS/S1/91 including COST of allmaterials required for casting and concreting and provision of holding down bolts & nuts." | — | — | — | 94,238.3 | |
| — | 5.00 | — | — | ||
| "Casting, concreting and curing of foundation for Shunt signaland as per DRG.No.SGW/MGS/S1/91 including COST of allmaterials required for casting and concreting and provision ofholding down bolts & nuts." | — | — | — | 19,821 | |
| — | 20.00 | — | — | ||
| "Supply of Battery Charger - Track Feed Up to 10 Amp, Spec.No.IRS:S-89/93 (Amd.-2) or Latest.Inspection by-RDSO" | — | — | — | 1,43,368 | |
| — | 20.00 | — | — | ||
| "Supply of B-Type choke coil having anneled enamelled copperwire for DC track circuit Spec. No. IRS-S- 65/83(Latest).Inspection by-RDSO " | — | — | — | 1,27,615.6 | |
| — | 150.00 | — | — | ||
| "Supply of PBT fuse block with inserts cartridge type, to bemounted inside the location Box/ Relay Rack. Fuse Base(DRG No. SA - 23748, IRS: S-75/91).Inspection by-RDSO" | — | — | — | 39,316.5 | |
| — | 150.00 | — | — | ||
| "Supply of PBT fuse block with inserts cartridge type, to bemounted inside the location Box/ Relay Rack. Fuses (2A, IRS: S-78/92).Inspection by-RDSO" | — | — | — | 24,412.5 | |
| — | 10.00 | — | — | ||
| "Installation wiring, testing and commissioning ofSingle/Doublerail DC track circuit as per approved track circuiting plan. Thework includes track battery charging and installation, trackbonding (double ) with 8 SWG soft GI Wire laying of tail cable with track lead junction box, rail connector with Galvanised iron wire tracklead junction box, rail connector with Galvanised iron wire track jumpering with supporting arrangement for holding as per IYD plan. It also includes installation and wiring of track feed chargers, track relays, track circuit, equipment in the location box including fuses and ARA terminals required for the purpose as per Drg.No.SK/10/95(NKG) including drilling of 9/32"" Hole on rails where required fixing of track lead junction boxes provision of tail cable terminations etc.1.) Track Circuit (Beyond 200 Mtrs.)" | — | — | — | 57,761.1 | |
| — | 5.00 | — | — | ||
| "Installation wiring, testing and commissioning of Single/Doublerail DC track circuit as per approved track circuiting plan. The work includes track battery charging and installation, track bonding (double ) with 8 SWG soft GI Wire laying of tail cable with track lead junction box, rail connector with Galvanised iron wire track lead junction box, rail connector with Galvanised iron wire track jumpering with supporting arrangement for holding as per IYD Plan. It also includes installation and wiring of track feed chargers, track relays, track circuit, equipment in the location box including fuses and ARA terminals required for the purpose as per Drg.No.SK/10/95(NKG) including drilling of 9/32"" Hole on rails where required fixing of track lead junction boxes provision of tail cable terminations etc.ii) Short length track circuit upto 200 mts." | — | — | — | 23,337.6 | |
| — | 5.00 | — | — | ||
| "Installation wiring, testing and commissioning of track circuitinvolving points & crossing as per Track circuiting plan. TrackBattery charging and installation including drilling 9/32'' hole on rails. Installation of bonding, double with 8 SWG soft GI Wire insulation of strecher bars double with 8 SWG soft GI Wire insulation of strecher bars (leading & following), guage/crossing tie plates involving cutting &rivetting/welding of angle clit, split stracher bars, fixing of cable with track lead junction box, rail connector with GI wire track jumpering with Including series jumpers, Jumper wire terminals, track feed set (track charger adjustable resistance, choke, coil, fuses, battery etc.) as per approved IYD for point zone track circuit." | — | — | — | 35,887.6 | |
| — | 20.00 | — | — | ||
| "Supply of complete ground fittings for point machine, including insulated stretcher Bar Switch extension piece etc. Piece etc. and all other accessories required for installation -DRG No. SGW/S/2/HWH/1/92, Inspection Consigneeii) For IRS point machine (Spec. IRS -24/90)a) Turn out (RDSO DRG. No. SA - 8800-01)Inspection-Consignee ," | — | — | — | 2,90,513.8 | |
| — | 20.00 | — | — | ||
| "Dismantling of existing point fittings drilling of holes in stockrail/tongue rail /guage tie plate and installation of electricpoint machines on MS plate fixed on wooden / concretesleepers complete with fixing of junction boxes, groundconnection including smithy works involved, insulation of MSplate on which the point machine is to be fixed from the guagetie plate involving revetting/welding of angle cleats,installation of point JB, Termination of cable, Priliminaryadjustment for operation of points by crank handle paintingand lettering as required including wiring testing andcommissioning as per technical specification.Note:- MS plate / Flat/ Anglle/ Angle cleats, paints, bolts &nuts and washers of sizes as required for fixing the pointmachine shall be supplied by the contractor except pointmachine .ie) For IRS point machine (Spech..IRS 24/90)a) Turn out(Note- MS plate/flat/anglle/Angle cleats, paints, bolts & nutsand washers of sizesas required for fixing the point machine shall be supplied by the contractor except point machine)" | — | — | — | 2,39,772.2 | |
| — | 180.00 | — | — | ||
| "Supply of lead acid secondary cell to IS-1651 and RDSO letter no STS/E/Cells/Secondary with intercell connectors, level indicator porcelain insulator, for mounting and ceramic vent plugs 80 AH. (Number means Cell).Inspection by-RDSO" | — | — | — | 8,14,062.6 | |
| — | 15.00 | — | — | ||
| "Charging of lead acid secondary cells of various capacities as per manufactures instruction/ railway engineer's instructions. Acid & distilled water will be supplied by the contractor's)80 AH (12 Cell)" | — | — | — | 59,552.55 | |
| — | 3.00 | — | — | ||
| Supply of CT rack (DRG.N0.S&T/C-19/ 2001/ER) complete with all fittings including 6 way/8 Way PBT Terminals as per Spec No. IRS-79/92.or Wagoo terminals as decided by site in charge. Note: PBT terminals to be inspected by RDSO and CT- Rack, Wagoo by Consignee. | — | — | — | 1,79,829.18 | |
| — | 3.00 | — | — | ||
| "Installation of cable termination Rack with scaffolding materials; ladder for supporting outdoor cable; wire guide; complete with other necessary hardwares as per requirements of Rly. & erection materials. (Station Wise Qty. to be specified by the tenderer.)I) Upto 4 to 5 Line Station" | — | — | — | 17,982.93 | |
| — | 50.00 | — | — | ||
| "Supply of earth electrode material to be procured as per E.Rlysketch No. SGW/T/3/G/8/89.Inspection by- Consignee" | — | — | — | 99,636 | |
| — | 50.00 | — | — | ||
| "Fixing of Earth electrode including earth wire as per DRG.No. S&T/C- 41(NKG)for apparatus cases, signal post and other equipment as per instruction of site engineer all materials except earth ." | — | — | — | 55,361.5 | |
| — | 50.00 | — | — | ||
| "Supply and laying of earth lead wire soldering of lead wire to earth electrode and apparatus case/signal post as per instruction on earthing and providing cement enclosure for earth electrode as per DRG. No. S&T/C-36(NKG). This includes supply of all materials by the contractor.Inspection by-Consignee" | — | — | — | 68,889 | |
| — | 500.00 | — | — | ||
| — | — | — | 5,80,100 | ||
| double walled with IS inner dia | : - "Supply of power/communication/Signal/OFCprotection outer dia 175mm and | DWC pipe 16205 part-24:2018 148mm.Inspection | for and T-Joint | ||
| — | 500.00 | — | — | ||
| "Installation of Double Wall Corrugated (DWC) pipe withsocket coupler. This includes trenching 1.2 mtr. Depth and back filling. " | — | — | — | 54,590 | |
| — | 100.00 | — | — | ||
| "Filling earth around location box/signal post for a width of 0.5 m on all sides, upto a level of 150 mm below the foundationtop. This work includes consolidation of earth by watering(Unit CUM means per CUM)watering." | — | — | — | 22,495 | |
| — | 300.00 | — | — | ||
| "Supply of Non deteriorating type low voltage cartridge fuse as per Spec. No. IRS/S/78/92. Round head type. 6 Amp. Capacity. Inspection by-RDSO" | — | — | — | 36,387 | |
| — | 500.00 | — | — | ||
| "Supply of Non deteriorating type low voltage cartridge fuse as per Spec. No. IRS/S/78/92. Round head type. 16 Amp. Capacity "Inspection by-RDSO | — | — | — | 56,565 | |
| — | 250.00 | — | — | ||
| "Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils. Spec.no, IRS- S-76/89 material to be procured from RDSO approved firm only with performance guarantee. 16/0.2 sq mm.Numbers means per coil.Inspection by-RDSO" | — | — | — | 2,96,160 | |
| — | 100.00 | — | — | ||
| "Relay, AC Immune plug - in type, Style 'QTA2', DC Neutral track, 9ohm, 2F/1B contacts, front and back contacts metal to carbon complete with plug board, retaining , clip & connectors conforming to BRS : 939A,BRS:966 (Appendix F2), IRS:S 34 & IRS : S 23 (as applicable ). The interlocking code for this unit shall be FGHKX. Inspection by-RDSO" | — | — | — | 7,60,898 | |
| — | 100.00 | — | — | ||
| "Relay, plug in type, Style QL1, magnetically lactified, Neutral line, 24VDC 11F/4B contacts, front and back contacts metal to carbon, complete with plug board, retaining clip & connectors confirming to BRS: 935A, IRS S 345 IRSIS 23 (As applicable). The interlocking code for this unit shall be ABDEG.Inspection by-RDSO" | — | — | — | 7,75,822 | |
| — | 50.00 | — | — | ||
| "Relay, Non-AC Immune plug-in type, Style 'QNN1"", Twin DC Neutral ling, 24V, 6F/2B , 25 contacts each for LH and RH, front and back contacts metal to carbon,. Complete with plug board, 24 retaining clip &corinectors conforming to BRS: 960, IRS S 348 IRS:S 23 (as applicable). The interlocking code for this unit shall be ACDEK.Inspection by-RDSO" | — | — | — | 3,05,528 | |
| — | 75.00 | — | — | ||
| "Supply of fail safe electronic time delay device mounted on Q series relay base & covered with fixed timing of 120 sec. As per RDSO Spec.no.IRS-5-61/2000, IRS-S-34 & IR5-5-23 (as applicable). Interlocking code for this relay shall be AFGKY.Inspection by-RDSO" | — | — | — | 8,73,073.5 | |
| — | 100.00 | — | — | ||
| "Relay, AC immune, plug in type, Style'QBCA1', DC biased point contactor, 24V, 2F(HD).4B contacts, front contacts (Heavy duty) and back contacts metal to carbon complete with plug board retaining clip and connectors confirming to BRS 943, IRS 534 & IR5:5 23 (As applicable). The interlocking code for this unit shall be BC.Inspection by-RDSO" | — | — | — | 9,12,730 | |
| — | 250.00 | — | — | ||
| "Carrying out alterations to the existing relay wiring at relay rack/location as per the circuit diagram. The work includes releasing the existing unused wires and wiring the relays using wire PVC 16/0.02 mm copper. (Wire PVC 16/0.02 mm copper, paint, soldering materials and all other miscellaneous materials required for the work shall be supplied by the contractor. " | — | — | — | 1,25,805 | |
| — | 2800.00 | — | — | ||
| "Termination of cable cores on ARA terminals or on 8 way terminals in the cable termination rack. " | — | — | — | 53,144 | |
| — | 50.00 | — | — | ||
| "Installation, commissioning & testing of LED signals.(Qty unit Numbers means or aspect). " | — | — | — | 57,583 | |
| — | 20.00 | — | — | ||
| " Supply of Track feed resistance Disc type 0 to 15 Ohm as per drawing no. SA-20165/M .Inspection by-RDSO" | — | — | — | 16,814.4 | |
| — | 5.00 | — | — | ||
| "Dismantling & Releasing of following S&T gears. The work includes transportation of the released material to the store of respective Consignee's store (will be mention in Tender documents.) and properly stacking the same in the store.The rate shall cover the cost of tools and plants, ladders, scaffoldings, all other adjuncts required for the works.Signal post which includes dismentalling of unit, ladder, base mounted shunt signals and fitting, (units numbers means per signal) " | — | — | — | 9,193.2 | |
| — | 5.00 | — | — | ||
| "Dismantling & Releasing of following S&T gears. The work includes transportation of the released material to the store of respective Consignee's store (will be mention in Tender documents.) and properly stacking the same in the store.The rate shall cover the cost of tools and plants, ladders, scaffoldings, all other adjuncts required for the works. Location box /Junction box which includes releasing of terminal board, relays, terminals, batteries and chargers. " | — | — | — | 4,959.15 | |
| — | 2500.00 | — | — | ||
| "Painting of two coats of enamel paints lover one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary. Primer and paints both Asian paint make are to be supplied by the contractor. Numbering is to be as per practice of the ECR and directives of the site Engineer. (i) Location boxes inside and outsided surfaces with Aluminum paint. Single case." | — | — | — | 23,10,875 | |
| — | 150.00 | — | — | ||
| "Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary. Primer and paints both Asian paint make are to be supplied by the contractor. Numbering is to be as per practice of the ECR and directives of the site Engineer. (i) Location boxes inside and outsided surfaces with Aluminum paint. Half case. " | — | — | — | 1,11,387 | |
| — | 700.00 | — | — | ||
| "Painting of two coats of enamel paint over one coat of redoxide primer and there after numbering on the following itemsafter scraping and cleaning of the surface where evernecessary. Primer and paints both Asian paint make are to besupplied by the contractor. Numbering is to be as per practiceof the ECR and directives of the site Engineer.Main signal post, signal unit, Surface base and completefitting as per E.C.Rly standard practice." | — | — | — | 7,75,894 | |
| — | 59.00 | — | — | ||
| "Painting of two coats of enamel paint over one coat of redoxide primer and there after numbering on the following itemsafter scraping and cleaning of the surface where evernecessary. Primer and paints both Asian paint make are to besupplied by the contractor. Numbering is to be as per practiceof the ECR and directives of the site Engineer.Shunt signal post." | — | — | — | 27,023.77 | |
| — | 500.00 | — | — | ||
| "Painting of two coats of enamel paint lover one coat of redoxide primer and there after numbering on the following itemsafter scraping and cleaning of the surface where evernecessary. Primer and paints both Asian paint make are to besupplied by the contractor. Numbering is to be as per practiceof the ECR and directives of the site Engineer. Point machinewith ground connections complete.Point machine with black enamel only outside and groundconnection with red oxide" | — | — | — | 1,68,185 | |
| — | 50.00 | — | — | ||
| "Lettering & numbering of details and description writings ofparticulars of termination and equipments on relay rack,relays, cable termination rack, etc. constituting entire systemwith contractors own paint and writing materials. (""Asian""make enamel paint only to be used.). This includes supply &fixing of Teflon strips 3mm thick and 25 mm wide for eachrow of relays and cable as per extant practice on E.C.Rly andinstruction of Rly engineer at site." | — | — | — | 32,511.5 | |
| — | 35.00 | — | — | ||
| "Supply of 32 ft long octagonal booms as per RDSO spec no. RDSO/SPN/208/2012 (ver 2.0) with latest amendment.Inspection by-RDSO" | — | — | — | 17,09,919.05 | |
| — | 500.00 | — | — | ||
| "Timing belt as per RDSO Spec no. RDSO / SPN/ 208/ 2012 (ver 2.0) with latest amendment.L98 -L277 =300 Set ,L98 - L285 =100 set ,L98- L300 = 100 set.Inspection by-RITES" | — | — | — | 7,06,685 | |
| — | 50.00 | — | — | ||
| "Supply of LC Gate road user warning Alarm hooter along with accessories.(15 watt) Inspection by-RITES" | — | — | — | 12,23,921 | |
| — | 500.00 | — | — | ||
| Transportation of HDT machine with accessories includin ghandling of stores materials, preparation of site and boring of110 mm dia or above to suit site requirement and placing HDPE pipe of size 63 to 50 mm in single / double /triple etc required for crossing/laying of Railway S&T cables in a combination of quad & signalling cables etc. as per requiredcomprising upto 72 cores in any HDD section on land/bridges/ culverts / track /pucca road crossing and blowing pulling ofQuad /S&T cables within HDPE pipe. Boring of trench shall be minimum 3 (three) meter or more below the river bed, 01(one) Mtr below or more the track and 1.5 (one point five)meter below or more other lands including road /pucca road crossing area. This includes supply of permanently lubricated HDPE pipe of size 63 to 40 mm dia& its accessories suitablefor HDT as per Specification No.RDSO/SPN/TC/45/2013Rev.2.0 with Amdt. 3 or latest amendment & cost of the fueland all other items which will be required for laying of cable through it.Inspection : Consignee for HDPE pipe NOTE: The number of HDPE pipes (of any dia as mentioned above) to be pulled in any HDD section will depend upon the numbers of S&T cables to be pulled through that HDD section as per site requirement. At a particular site, the second /additional HDD is to be done only after completing thepullingof 72 cores of cable through 1st HDD other wise thesecond / additional HDD will not be counted as anew/additional HDD for the purpose of billing. Only S&Tcables to be supplied by Railway. Printed Cable sketch plan showing dirversion & depth, which shall be generated by machine to be submitted by firm just after every boring & tobe submitted while billing. | — | — | — | 8,65,990 | |
| — | 25.00 | — | — | ||
| "Providing and laying in position cement concrete of 1:3:6 (1cement 3 sand: 6 graded stone aggregate 20 mm nominal size)Including cement." | — | — | — | 1,34,811.5 | |
| — | 20.00 | — | — | ||
| "Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. Nos.RDSO/SPN/197/2016 Ver 1.0 or latest, bondingconnections drawing Nos. SDO/ RDSO/E&B/002 or latest areas under,(a) Copper bonded steel electrodes of 3.0 m long,17.0 mm diameter with copper bonding thickness of min 250micron and UL listed and marked -1 Nos. (b) EarthEnhancement compound supplied in sealed bags of min 30-35Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x6mm toexothermically welded to Earth electrode- 1 Nos.(d)Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 Nos. (e)Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 Nos. Italso includes supply of (i) 35 Sq. mm Multi-strand SingleCore PVC insulated Copper Connector as per IS:694 forconnecting Main Earth Electrode to MEEB in the equipmentroom in duplicate.-10 meter (ii) 16 Sq. mm Multi-strandSingle Core PVC insulated Copper Connector as perIS:694 for connecting MEEB to SEEB and SPDs toMEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single CorePVC insulated Copper Connector as per IS:694 forconnecting various equipment to SEEB- 10 meter.Inspection by-RDSO" | — | — | — | 4,17,640 | |
| — | 500.00 | — | — | ||
| "Supply of PVC insulated 35 Sq. mm Single core Multistrandscopper conductor as per Specification Nos.IRS:S-76/89 or latest conforming to IS: 694/2010 orlatest. Wire Colours shall be decided by engineer-in-Charge.Inspection by-RDSO" | — | — | — | 1,27,000 | |
| — | 500.00 | — | — | ||
| "Supply of PVC insulated 16 Sq. mm Single core Multistrandscopper conductor as per Specification Nos.IRS:S-76/89 or latest conforming to IS: 694/2010 orlatest. Wire Colours shall be decided by engineer-in-Charge.Inspection by-RDSO" | — | — | — | 74,500 | |
| "Installation of Single Maintenance Free Earth pit as per RDSODrawing Nos. SDO / RDSO/ E&B/001 which includes thefollowing,a) Digging/Auguring/Boring of single earth pit of100mm to 125mm dia. to the depth of approx. 3 meter.b) Insertion of 3.0 meter electrode and penetrating itminimum 150 mm by pushing gently with sledgehammer where the natural soil is assumed. (c) Filling of earthpit with Earth Enhancement Compound (EEC) in slurryform and backfilling. (d) Carrying out exothermic weldconnection on single earth electrode to a copper tape of 200x 25 x 6 mm. (e) Carrying out exothermic weldconnection on the copper tape of 200 x 25 x 6 mm on EarthElectrode for connecting two 35 Sq. mm cables forredundancy. (f) The exothermic welding material for bondingthe earth system shall be procured from RDSO approvedfirms, which includes graphite modules, clamps, weldmetal powders etc. (g) The dimension of the chamber willbe of 300 x 300 x 300 mm (inside dimension) of RCCwith 50mm thick and fine finish, Inspection chambershould be as per IEC 62561-5 or latest. The top RCCcover size shall be 400 mm X 400 mm X 50mm. The date oftesting and earth resistance value shall be written on the coverwith black base with yellow paint or as per instruction of siteengineer." | — | 20.00 | — | — | |
| — | 1000.00 | — | — | ||
| "Supply of Disconnect type Terminal, screwless, 2 IN 2 OUT (as per spec. no. RDSO/SPN/189/2004 or latest) along with all accessories including separators for fixing on Cable Termination Rack/Location boxes for Cable Termination Purpose.Inspection by-RDSO" | — | — | — | 1,04,750 | |
| — | 200.00 | — | — | ||
| "Supply of screwless end stop, 10mm/0.394 in wide carmer rail din 35, grey similar to Wago part No. 249- 117.Inspection by-Consignee" | — | — | — | 4,124 | |
| — | 200.00 | — | — | ||
| "Supply of steel carrier rail 35 x 7.5mm, 1mm/0.039 in thick,unslotted similar to 23 Wago part No. 210- 229/PW11- 0000.Inspection by-Consignee" | — | — | — | 35,424 | |
| — | 2250.00 | — | — | ||
| "Supply of channel Pin with single groove 7.2 mm Dia for 4 mmDiabond wire to DRG. No. S-69/M & IRS Spec no. IRS:S-S17.Inspection by-Consignee" | — | — | — | 12,487.5 | |
| — | 20.00 | — | — | ||
| "Supply of Thermo-shrink jointing (TSF) kits for jointingunderground Quad cable of size 0.9mm/1.4mmdiameter conductor for straight/condenser/Y-(Derivation)/Loading Coil/Transformer Joints as perSpecification Nos. IRS-TC-77/2012 Rev.3 with Amd. 3.0or latest.Inspection by-RDSO" | — | — | — | 65,200 | |
| — | 20.00 | — | — | ||
| "Execution of Straight joint on Quad cable/ jelly filledTelecom cable using Thermo-shrink/Universal jointing kit(RTSF). This includes excavation of cable joint pit of size1.5 m X 1.5 m X 1.2 m for jointing of cables, back fillingand ramming after jointing. After jointing, the cablethrough test such as insulation test, continuity test etc.to be carried out jointly with Railway Engineer. If anydefect or any damage is observed during jointing thecontractor has to redo the joint free of cost.Note: In casejointing is required to be done in the Location boxes,then 80% payment will be released." | — | — | — | 29,960 | |
| — | 1.00 | — | — | ||
| "Supply of PVC Insulated Multicore copper conductorIndoor Cable of size 60 Core x 0.6mm diaMeter as perSpecification Nos. IRS:S-76/89 or latest.Inspection by-RDSO" | — | — | — | 1,36,874 | |
| — | 100.00 | — | — | ||
| "Supply of MS number plate (200mmx300mmx3 mm ) withfixing calmps. Letter shall be of black colour in the white background. Details of description shall be given by site engineer.The plate & clamps shall be painted before lettering of signalnumbers.Inspection by-Consignee" | — | — | — | 95,489 | |
| — | 5.00 | — | — | ||
| "Supply of AC/DC digital true RMS clamp meter 3-3/4digit(6000 count) AC/DC Amp 0-200 Amp AC/DC voltage 0- 600V resistance0-60 MEGA Ohms frequency 0-999 KHz.Inspection by-Consignee" | — | — | — | 38,052.1 | |
| — | 5.00 | — | — | ||
| "Supply of insulation Megger 500/100 Volts, 1000 mega Ohmsrange, with Digital/Analog (As per instruction of siteincharge) Read out. (make & Model-RISHAV Make &Model- RISHInsu-10 or similar/superior).Inspection by-Consignee" | — | — | — | 56,326.55 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderNotice.pdf
ATTACHMENT
Tender1stsheet.pdf
ATTACHMENT
GCCwithACSupto12th.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
Annexures.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .