Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC Lowes Bid Value. | |
| 2 | L2₹13.8 L+₹46,580 (3.50%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC Higher Bid Value. | |
| 3 | L3₹14.6 L+₹1.3 L (9.52%)Rejected-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-AOC Higher Bid Value. | |
| 4 | L4₹15.3 L+₹2.0 L (14.8%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC Higher Bid Value. | |
| 5 | L5₹15.4 L+₹2.1 L (15.8%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L5 | Rejected-AOC Higher Bid Value. |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE HQ TC AIR FORCE BANGALORE 560006
SPECIAL REPAIRS/ REPLACEMENT OF LT CABLE AND LT PANEL FOR COVID ICU AND REFREGERATION AGAINST BER AT CHAF BANGALORE
2021_MES_418151_1
8742/GE-64
Open Tender
Civil Works
Item Rate
180 days
CH (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹35,000
Yes
18 Mar 2021
2 Feb 2021
3 Mar 2021
2 Feb 2021
1 Mar 2021
17 Feb 2021
3 Feb 2021 - 8 Feb 2021
Amount
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable, complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm, complete all as specified and directed.
Removal of surplus soil (excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
River sand, spread dry in trenches as in cable cushioning ,Before laying the cable, the trench shall be provided with a layer of sand of 8 cm depth and the cable has been properly straightened, it shall be covered with sand to a depth of 15 cm , then gently punned down to a depth of 10 cm above the top of the upper-most cable and punning shall be done by hand, complete all as specified and directed.
Burnt bricks, sub class 'B' of designation 75, standard size laid in trenches as in protection of UG cables, complete all as specified and directed.
GI tubing light grade 50 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. including taking up or down unserviceable existing steel tubing of any bore and connections for removal to store all as specified and as directed of following sizes.
All As per Item No 6 here in before but for 80 mm bore
Boring of holes under road pavment/hard standing by manual boring including making good to the distrubed surfaces, complete all as specified and directed
LT UG cable 4 core x 25 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, cable gland lugs/ thimbles/ ferrules including connecting, testing including taking down of old unserviceable under ground cable of any size, complete all as specified and directed. Notes: (a) Excavation earth work and sand cushioning brick protectionand connected work etc. Shall be measured and paid separately under relevant item of schedule
All as per Item No 09. but for 3.5 core x 50 Sqmm
All as per Item No 09. but for 3.5 core x 70 Sqmm
All as per Item No 09. but for 3.5 core x 120 Sqmm
All as per Item No 09. but for 3.5 core x 240 Sqmm
Replacement of "G" Frame Vertical load line double door distribution board 8 way having a provision of mounting MCCB (Frame 1) as incommer and MCB's as outgoing , busbar , neutral links to be flushed/mounting on wall , including connecting up the cables/wires with proper lugs/ferrule/thimbles/glands , testing, complete all as specified and directed Note : MCCB, MCB's Shall be measured and paid separately under relevant item of schedule Make : IndoAsian Cat No : 811890 or Equivalent in Havells/L&T
Replacement of MCCB, 3 pole, 415 Volts, 100A, fixed thermal ,fixed magnetic , 25 KA, 50 Hz, AC in sheet metal enclosure including connecting up incoming / out going cables with suitable lugs and testing, complete all as specified and directed. Make : IndoAsian/Havells/L&T or Equivalent
Replacement of MCB, TP , 415 Volts, 6 to 32 A, 10 KA, 50 Hz, 'C' curve in sheet metal enclosure including connecting up incoming / out going cables with suitable lugs and testing, complete all as specified and directed. Make : IndoAsian/Havells/L&T or Equivalent
Replacement of MCB, SP , 230 Volts, 6 to 32 A, 10 KA, 50 Hz,'C' curve in sheet metal enclosure including connecting up incoming / out going cables with suitable lugs and testing, complete all as specified and directed. Make : IndoAsian/Havells/L&T or Equivalent
Replacement of sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting TPN 415V MCCB upto 125A ,50Hz Frame 1 single door duly fixed on wall with all fixing arangements, complete all as specified and directed. Make : Indo Asian , Cat No : 811984 or Equivalent in Havells/L&T
Replacement of MCCB, 3 pole, 415 Volts, 20 to 63A, fixed thermal ,fixed magnetic , 16 KA, 50 Hz, AC in sheet metal enclosure including connecting up incoming / out going cables with suitable lugs and testing, complete all as specified and directed. Make : Indo Asian /L&T/Havells
Replacement of perforated Galvanised Cable tray with cover of size 150 x 50 x 1.6 mm including bends,couplers,cable tie,angle iron supports, anchor bolts/bolts & nuts etc duly grouted on wall/ceiling/floor including necessary cutting/fabrication work with complete accessories, complete all as specified and directed
Replacement of installing, testing and commisioning of CPRI approved LT cubical panel board 440 volts , 50 Hz , 3 phase , 4 wire , Out door type >IP 65 , weather, vermin, dust proof, front & Back operated with adequate air ventilation at sides and back fabricated out of 3.00 mm thick CRCA sheet with double door shutter and locking arrangements, cables trays, cable lugs,cable gland etc.including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables, danger board etc , floor mounted with PCC 1:2:4, type B1 platform of 50 cm height suitable nut bolts, washer etc. for grouting , and painting with power coated epoxy finish of approved colour over a coat of red oxide primer suitable to accomodate and including the following mentioned fittings, complete all as specified and directed comprising the following:-
(i) Bus bar chamber consisting of four Nos Aluminium bus bars duly sleeved of capacity of 630 Amps for phases and 315 Amps for neutral. Duly insulated with PVC sleeves RYB , mounted on heavy duty epoxy insulation in separate compartment.
(ii) Digital Voltmater and Ammeter three line display ( L1 L2 L3 ) with suitable CT's
(iii) LED type indicating lamps (RYB) with holders controlled by fuses and swicthes .
(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors.
(v) MCCB 3ø phase 415V, 400 Amps 4 pole 36 kA, Adjustable magnetic and fixed thermal - 1 No (I/C) (vi) MCCB 3ø phase 415V, 160 Amps 4 pole 16 kA, Fixed magnetic and Fixed thermal - 4 No (O/G) (vii) MCCB 3ø phase 415V, 63 Amps 4 pole 10 kA, Fixed magnetic and Fixed thermal - 2 No (O/G) Make : any CPRI Approved Panel
Replacement of Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire connected to main switch board and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh pcc 1:3:6 in chambers RCC 1:2:4 in pit cover reinforecd with 8 mm dia deformed bars 15 cm center both ways all as shown in Plate No. 4 to the earthing test point, complete all as specified and indicated/directed including testing on completion
Replacement of Earthing complete with copper earth plate 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr filled around with layer of charcoal dust and salt and connected to copper earth strip size of 20x3 mm by means of bolt nut and cheek nuts and washers of galvanized iron or steel and thimble and other ends of the earth strip connected to main switch board and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh pcc 1:3:6 in chambers RCC 1:2:4 in pit cover reinforecd with 8 mm dia deformed bars 15 cm center both ways, complete all as specified and indicated/directed.
Supply and install Refrigerator, single door ,electric driven, BEE 3 star rating (single phase 230V ,50Hz), of capacity upto165 litres or next higher capacity available in the market and connecting with existing power supply point, complete all as specified and directed. Make LG/Godrej/Voltas/Samsung.
Supply and install Refrigerator, double door ,electric driven, BEE 3 star rating (single phase 230V ,50Hz), of capacity upto286/290 litres or next higher capacity available in the market and connecting with existing power supply point, complete all as specified and directed. Make LG/Godrej/Voltas/Samsung.
devan enterprises
GKR and CO
RRK PROJECTS
M/s BHOOMI ELECTRICALS
SREE VINAYAKA ENTERPRISES
Vishwas Enterprises
vanithaenterprises
B5BUILDING SOLUTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .