Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 CrAccepted-AOC | ₹31.4 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹34.8 CrRejected-Finance | ₹34.8 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹35.0 CrRejected-Finance SCF 126 OPP SUKHRAJ CINEMA ROSE GARDEN COMPLEX G T ROAD BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | ₹35.0 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹39.6 CrRejected-Finance | ₹39.6 Cr | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | GEMINI PROMOTERS AND BUILDERS PVT. LTD. L2 | M/s DMR Builders Pvt Ltd L3 | BANSI BUILDER AND CONTRACTORS PVT LTD L4 | WALIA BUILDCON PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I | 1 | Lump sum | 24,00,00,000 ₹24 Cr | 25,53,54,244 ₹25.5 Cr | 28,17,34,009 ₹28.2 Cr | 23,27,35,465.7 ₹23.3 Cr |
| 2.00Sch 'A' Section- II, INTERNAL ELECTRIFICATION WORKS AND FLAME PROOF FITTINGS | |||||||
| 3.00 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed.
(switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). | 2,576 | Per Point | 1,200 ₹30.9 L | 944.44 ₹24.3 L | 1,400 ₹36.1 L | 1,200 ₹30.9 L |
| 4.00 | -do- all as per srl No. 3 above but one three pin switch socket outlet 5 Amps on the same borad | 231 | Per Point | 1,200 ₹2.8 L | 277.78 ₹64,167.18 | 450 ₹1.0 L | 600 ₹1.4 L |
| 5.00 | -do- all as per srl No. 3 above but one call bell controlled by one bell switch | 112 | Per Point | 1,200 ₹1.3 L | 416.67 ₹46,667.04 | 1,500 ₹1.7 L | 1,000 ₹1.1 L |
| 6.00 | -do- all as per srl No. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 Amps point (on independent board) | 784 | Per Point | 1,500 ₹11.8 L | 1,041.67 ₹8.2 L | 1,500 ₹11.8 L | 1,200 ₹9.4 L |
| 7.00 | Material and labour for concealed Point wiring for one socket outlet 15/20 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed.
(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). | 704 | Per Point | 1,800 ₹12.7 L | 1,250 ₹8.8 L | 2,400 ₹16.9 L | 1,500 ₹10.6 L |
| 8.00 | Supply only modular switch 6Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). | 3,591 | Each | 80 ₹2.9 L | 138.89 ₹5.0 L | 75 ₹2.7 L | 46 ₹1.7 L |
| 9.00 | Supply only modular switch 16Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). | 704 | Each | 140 ₹98,560 | 208.33 ₹1.5 L | 160 ₹1.1 L | 135 ₹95,040 |
| 10.00 | Supply only modular socket outlet 2 in 1, 6Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). | 1,015 | Each | 280 ₹2.8 L | 208.33 ₹2.1 L | 250 ₹2.5 L | 100 ₹1.0 L |
Tender Value
₹28 Cr
EMD Value
₹15 L
Closing Date
19 Jul 2025, 6:00 pmClosed
Chief Engineer Bathinda Zone
Headquarters Chief Engineer Bathinda Zone Military Engineer Services PIN- 900484 C/o 56 APO
PROVISION OF DEFICIENT MARRIED ACCOMMODATION AT FAZILKA MIL STN
2025_MES_706917_1
84466 CE BTZ/FZK/TOKEN-13 OF 2025-26
Open Tender
Civil Works
913 days
GE Abohar
As per NIT
7 documents required · 7 mandatory
₹3,000
GE Abohar
₹15 L
HQ Chief Engineer Bathinda Zone
27 Aug 2025
6 May 2025
21 Jul 2025
6 May 2025
19 Jul 2025
5 Jul 2025
6 May 2025 - 10 Jun 2025
20 May 2025
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Sch 'A' Section- II, INTERNAL ELECTRIFICATION WORKS AND FLAME PROOF FITTINGS
Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
-do- all as per srl No. 3 above but one three pin switch socket outlet 5 Amps on the same borad
-do- all as per srl No. 3 above but one call bell controlled by one bell switch
-do- all as per srl No. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 Amps point (on independent board)
Material and labour for concealed Point wiring for one socket outlet 15/20 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate).
Supply only modular switch 6Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular switch 16Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular socket outlet 2 in 1, 6Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular socket outlet 5 in 1, 16Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 Amp, ISI Marked complete all as specified and as directed by Engineer-in-charge.
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge.
Supply only modular Bell Push switch, piano flush type, 6Amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by Engineer-in-charge.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum having wattage maximum 26 watt with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified and as directed by Engr-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Supply and fixed for SPN 8 way, 240 volt distribution board door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixed for SPN 6 way, 240 volt distribution board door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixed for SPN 4 way, 240 volt distribution board door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixed for TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper Bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, IP-54 protection and provision and including MCCB 4 pole upto 100 Amp, 16 KA as incomer and MCBs as outgoing, dust and vermin proof complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, B Curve as 40 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, B Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixing blanking plate of plastic suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for submain wiring comprising single core, 2 Runs of 4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 20mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for submain wiring comprising single core, 2 Runs of 10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) Aluminium housing & Integrated Electronic driver (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6500K (m) CRI : more than 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED tube light fitting polycarbonate housing 1 x 10 Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6500K (l) CRI : more than 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED lamp 1x9 watt including PVC holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by Engineer-in-Charge
Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Rigid non metallic PVC Conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for Mild steel box flush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin TV socket outlet flush type marked with symbol of TV and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed by Engineer-in-Charge
Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 25 litres, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Supply and fixing for LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing Earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed. Note :- (i) Conduit/pipe as required, same shall be measured & paid separately under respective item of this Sch/BOQ.
Material and labour for concealed Point wiring for one light point controlled by two switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers for piano type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate.
Suplly only modular switch 2 way, 6 amp, 1 module complete all as specified and directed
Supply and fixing LED backup/Rechargeable tube light polycarbonate housing 1x18/20 watt, appx 4 feet long module complete all as specified and directed
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), INTERNAL WATER SUPPLY WORKS
Supply and fixing two way Bib cock/Angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ. Note for CPVC pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by Engr-in-charge.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ. Note for CPVC pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by Engr-in-charge.
Supply and fixing single lever concealed diverter incl bath spout & Shower complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for brass chromium plated Aquaguard/RO inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for 40mm bore CPVC long handle vavle complete all as specified and as directed by Engineer-in-charge.
Supply and fixing health faucet fancy type, CP including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “ROAD, PCC TILES AND HUME PIPE CULVERT WORKS) " as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV (Part-II), ROAD, PCC TILES AND HUME PIPE CULVERT WORKS
Material and labour for premix bituminous concrete 40mm consolidated thickness with min 5.4 % binder content (bitumen of grade VG-30) by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified tolerance and internal heating arrangement for the screed all as specified in Table 500-17 of MoRTH specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by Engineer-in-Charge
Supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engineer-in-Charge Note:- Tiles shall be approved by GE before incorporation in the work.
Material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
Material and labour for preparation of new plaster surfaces/concrete surfaces/ kerb stone surfaces of any description, exceeding 10 cm in width or girth not otherwise described, by cleaning the dust, removing all loose particle using clean cloth, brooms and dry paint brush etc and after preparing the surface applying two coats of luminous road marking paint of approved tint/colour (one colour or alternative colour i.e. black/white/golden yellow etc as directed) including necessary priming coat as per manufacturer's instructions complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “(AREA DRAINAGE WORKS)" as listed in Schedule ‘A’ Section -V
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II), SEWAGE DISPOSAL WORKS
Supply and laying DWCPE (SN8) drain pipes 180 (OD)/163(ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch
Supply and laying DWCPE (SN8) drain pipes 200 (OD)/175(ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY FENCING AND GATE WORKS" as listed in Schedule ‘A’ Section - VII
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS " as listed in Schedule ‘A’ Section-VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), EXTERNAL WATER SUPPLY WORKS
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.6 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS
Supply and fixing lightning arresters HT 11000 V non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to IS 3070 (Part-I) 1985 complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning outdoor type Compact Sub – Station (CSS) comprising 11KV, 630 Amp VCB, 315 KVA Copper Wound Oil Cooled Off Circuit Transformer & LT Panel with base and trenches for cable with cover by use suitable material PCC, plaster and bricks Complete all as specified and as directed including the following:- (a) HT Section:- (i) 11 kV, 630 Amp, Indoor Type, VCB Horizontal Draw out Horizontal isolation floor mounting motorized panel with 230v motor mechanism & 24v DC Shunt/Close coil with CT, PT, IDMT Relay, 8 Window Enunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit and other fittings & accessories. Nos 01. (ii) Potential Transformer – 3 Phase cast resin of ratio 11kV/110V, Class-0.5, 100VA with HT Primary Fuses. (Nos 03). (iii) Current Transformer –Cast resin Ratio: 60-30/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA (Nos 01) (iv) Protection :- Numerical 2OC + 1EF Relay and Auxiliary Relay. (Set one) (v) Micro Processed based Non-Directional IDMT. (Nos 01) (vi) Indication Lamps:- VCB off / on / auto trip/ Trip circuit healthy/spring charge indication (set one) (vii) Metering:- Digital Ammeter & Digital Volt Meter (Set one) (b) Transformer Section:- Transformer 315 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box. Transformer as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 955W Losses @100% Load - 2750W (c) LT Section:- LT Panel comprising of LV Side Incomer – 01 no. -500 Amp 4 Pole 415V 35 KA MCCB with thermal magnetic based release with O/L & S/C protection. - RYB Indication
(d) Enclosure Section (i) Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control (ii) MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel. (iii) Provision for receiving Incoming cables thro Bottom entry and out going (iv) through Bus bar to Trf panel, Excluding Termination Kit & Glands (v) Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry Excluding Termination Kit & Glands (vi) Bus Bar – Aluminum (vii) Earth Bus – Aluminum (viii) Paint shade: Siemens Grey ( RAL 7032)
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:-
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:-
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:-
Supply and fixing cable junction box of Size 280mm x 200mm x100mm or any other higher size (Suitable for Pole mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 65 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Suitable size of mild steel Clamps and screws/nut bolt shall be used for fixing of Junction box..
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto 7.5 mtr length, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
S&F for GI steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting GI Pipe 1.5 Mtrs including MS Clamp and nut bolts complete all as specified and as directed by Engr-in-Charge.
Supply & fixing LED of 70 Watt IP 66 Street lights fittings aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary and IP66 protection. 10 KV SPD included Efficacy ≥110/120 LPW complete all as specified and directed by Engineer-in-Charge
Supply and install factory made Octagonal poles conform to IS-2062/BSEN 10025 (7.0 meter long) complete with MS base plate of size 250x250x16 mm thick at bottom, welded at centre through hole of 14 mm dia ,height of 14mm dia 300 mm above the coping including painting of poles with two coats of synthetic enamel paint over a coat of primer black and white/yellow strips 30 CM wide each (05 Nos) up to 1.5 meters height from coping and numbering of poles and provn 40 amp SPN, 240 voltage to be fixed approx1.5 mtr above from the ground level in the pole complete all as specified and directed
Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 50mm minimum inside dia 38mm conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable up to 35 sqmm 3.5 core complete all as specified and directed.
Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 110 mm minimum inside dia 95 mm conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable up to 120 sqmm 3.5 core complete all as specified and directed.
Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 120 mm minimum inside dia 103 mm conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable up to 240 sqmm 3.5 core complete all as specified and directed.
M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed. Note:- Pipe shall be measured and paid separately.
Subtotal
Sch 'A' Sec - X, FIRE FIGHTING EQPT WORKS
Supply and fixing fire hydrant landing valve type 'A' (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to IS 903 (for internal hydrant at Ground floor to 3rd floor and roof) complete all as specified and as directed.
Supply, installing, commissioning and testing of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, Finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( Sample to be approved prior to entire supply) complete all as specified and as directed.
Supply, installing, commissioning and testing of wall mounting swinging type First aid fire hose reel with drum, hanging bracket, 30 mtr long and 20mm dia high pressure hose reel as per IS 444 with gunmetal shut off nozzle having 5mm dia orifice. The hose reel shall be conforming to IS 884-1985. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or MS stand as per site requirement complete all as specified and as directed.
Supply, installing, commissioning and testing of 63mm dia Gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with GM nozzle of 20 mm nominal size conforming to IS 8090 complete all as specified and as directed.
Supply, installing, commissioning and testing of gun metal body Butterfly valves of size 65mm dia, IS:210, PN-16, confirming to IS:13095 complete all as specified and as directed.
Supply, installing, commissioning and testing of Booster Pump 30 m head, 450 LPM discharge, 440 V, 3 Phase, 50Hz confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed.
Supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, MS heavy duty ('C' Class) flanged pipe, ISI marked (IS : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed.
Supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 Ltr capacity conforming to IS:13386 with extinguishing agent : water+AFFF and propelling Nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 Mtrs., with ISI certification mark complete all as specified and as directed.
Supply and fixing carbon-di-oxide 3 Kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing No., confirming to IS:15683:2006. Fire rating 3A: 89B, ISI certification mark complete all as specified and as directed.
Supply and fixing Dry Chemical Powder Fire Extinguisher ( ABC POWDER ) 9 Kgs capacity Stored Pressure type, CE Mark Valve with NRV & Safety Release Provision with EPDM Rubber Hose, The extinguisher is internally coated with Epoxy Polyester and externally coated with Pure Polyester Powder and confirming to IS:15683:2006. Fire rating 3A: 89B, ISI certification mark complete all as specified and as directed.
Supply and fixing mechanical foam Extinguisher of 9 Ltr capacity and confirming to IS:15683:2006 complete all as specified and as directed.
Supply and fixing fire buckets (dry sand) of 7 Kg capacity including hanging arrangements complete all as specified and as directed.
Supply and fixing emergency Exit Sign Board with double side adhesive tape vinyl sticker with forex board (Green and White colour) 30 cm x 10 cm complete all as specified and directed.
Subtotal
Lump sum price worked out by the tenderer for “LIFT WORKS" as listed in Schedule ‘A’ Section - XI (Part-I)
Sch 'A' Sec - XI (Part-II), (LIFT WORKS)
Design, supply, installing, commissioning and testing 13 passenger lift, Machine Room less (MRL) having 1.0 m/s car speed, gearless motor suitable for 3- Ph, 415 V, 50 Hz electric power supply , conforming to IS-15785:2007 sutable to serve G+3 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, singlex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescu device (ARD) system, 2D infrared sensor in full height offf door & built in press and speak 3 way intercom. Complete all as specified and as directed and shall conform to the following specifications:
• PRODUCT: - MRL-1MPS • DETAILS: - MRL-1MPS • CAPACITY (Kgs): - 884 Kg, 13 persons. • SPEED (mps): - 1 meter per second • RISE (m): - 12 m • STOP: - 4 Stop with (all opening on the same side) • CONTROLLER TYPE: - LVA/ACD • DRIVE: - VF Regenerative (close side) • POWER SUPPLY: - 400/415 Volts (3 Phase AC) • OPERATION: - Full collective operation • CAR GROUP: - One car (simplex) • MACHINE: - PM Gearless • CAR FINISH: - (i) Rear Mid Panel = Stainless Steel #4 (Hairline) (ii) Rear Corner Panels = Stainless Steel #4 (Hairline) (iii)Side Mid Panels = Stainless Steel #4 (Hairline) (iv)Side Corner Panels = Stainless Steel #4 (Hairline) (v)Front Panels = Stainless Steel #4 (Hairline) • FALSE CEILING TYPE: - CD-41 • FALSE CEILING FINISH: - Stainless Steel #4 (Hairline) • VENTILLATION: - Cross flow fan • HAND RAILS: - STEEL POWDER PAINTED BLACK Handrails on rear car panels
• FLOORING: - Vinyl Tiles • CAR DOOR FINISH: - Stainless Steel #4 (Hairline) • LANDING DOORS FINISH: -Stainless Steel #4 (Hairline) • FIRE RATED DOORS: - Fire rating-120mins • PIT DEPTH: - 1600 • OVERHEAD: - 4800 • HOISTWAY DIMENSIONS (W x D – mm): - 2300 mm W x 1800 mm D • 4 | CAR DIMENSIONS (W x D x H - mm): - 1600 mm W x 1350 mm D x 2200 mm D • CAR & HOISTWAY DOOR TYPE: - Central opening (CO) doors • OPENING (W x H – mm): - 900 mm W x 2000 mm H • DOOR OPERATOR: - DC Door Operator • COP: - COP for stops <= 12 (950mm) in Stainless Steel # 4 (Hairline) • CAR POSITION INDICATOR: - Monochrome LCD-Blue Background & White font • HALL FIXTURES: - O2000 • HALL FIXTURE FACE PLATE: - Stainless Steel #4(Hairline) • HALL BUTTON ARRANGEMENT: - Hall Button with Hpi • STANDARD FEATURES: - Anti-nuisance Car Call Protection Independent Service (for Duplex only) Overload Device Nudging Emergency Firemen’s Service Emergency Car Light Unit Infrared Curtain Door Protection Door Time Protection Emergency Alarm Button Extra Door Time of Lobby & Parking Door Open/Close Button Manual Rescue Operation Belt Inspection Drive Auto Fan Cut Off • OPTIONS INCLUDED: - Smooth deceleration, Automatic Rescue Operation
Supply, Installation and Commissioning of 15 KVA three phase to three phase series online UPS system with SMF Battery for input-3Phase /output -3phase with approx. 2hrs Battery backup inbuilt Ultra –isolation Transformer. INPUT VOLTAGE 380/400/415VAC-15%+15% OUT PUT VOLTAGE 380/400/415/VAC+/-1% with the following specifications: - (a) Battery specification: - 12V *100AH*30Nos, including battery racks, battery, battery wire and cables connectors etc. (b) Input Parameters: - Nominal Voltage: - 380/400/415/VAC, 3 Phase, 4 wire/5 wire Voltage Range: - -15%+15% Phase seq/Reversal correction: - Yes Power Factor: - 0.9 to .099 Nominal Frequency: - 50 Hz (c) Output Parameters Nominal Voltage: - 230/400 VAC (As required) Voltage Regulation: - +/-1% Voltage Regulation: - Better than +/-5% Nominal Frequency: - 50 Hz Total Harmonic distortion (linear load): - Better than 3% on full load Transient Recovery (Time): - 4 ms for 100 % step load change Transient variation (Voltage): - 1% for 100% step load change Overload capacity: - 150% for 60 sec Inverter Efficiency: - >96% Communication Port: - RS 485 available (Optional) Isolation Transformer: - Inbuilt in design Extra Features: - Hot Standby Mode (1+1) available, As per Requirement (d) Inverter Parameter Technology: - Microprocessor controlled Double conversion advanced VFI inverter with Isolation Transformer at the Output.
Control Technique: -Adaptive sine wave PWM with high Frequency switching (20 KHz) using IGBT as Principles within devices. (e) Battery Parameters Battery Type: - SMF Type (f) Battery Charger Type Battery Charger Type: - High Efficiency CVCC temperature Compensated charger. Battery Recharge: - 8 to 10 Hours continuously. Battery Charging current: - Proportional to 10 Hours rate for the Rated AH of Batteries. (g) Alarms Mains Failure: - Indication on panel Battery Low: - Audible & Indication on Panel (h) Indicators Display Type: - Micro Controller Based LCD Metering Input Voltage: - RY, YB, BR (Digital Numeric Value) Load level: - Percentage of rate load in use. Battery Charge status: - Percentage of battery Charge. Frequency: - Digital numeric valve (i) Protection Input: - Over Voltage, under Voltage, Phase failure. Inverter: - Overload/Fail Battery: - Over Charging. (j) Battery Voltage;- 360/480VDCas Per Requirement
(k) Indications (1) R,Y,B Input (2) Rectification (3) Boost Charging (4) Rect. Trip (5) Mains OK (6) UPS on battery/ UPS on mains (7) Overload (8) 360 VDC (l) General Operating Temperature range: - 25-35 degree. C Relative Humidity: - 0-95% none condensing (m) Regulator EMC/EMIRFI IEC62040-1/2 Approvals:- CE/ISO9001 & ISO14001
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - XII
Schedule 'A' Section -XIII (Furniture Works)
Almirah small steel as per drawing No. FD-1032 sheet No. 1/1
Book shelf open (large) steel as per drawing No. FD-69(M) sheet No. 1/1
Bed Hard as per drawing No. FD/E6/MAP/08(R) sheet No. 1/1
Chair Verandah as per drawing No. FD/E6/MAP/11 sheet No. 1/1
Charpoy folding IP with hard top as per drawing No. FD-388(R) sheet No 1/1
Peg Table as per drawing No. FD/MAP/11 sheet No. 1/1
Rack shoe steel as per drawing No. FD/E6/MAP/02(R) sheet No. 1/1
Table bed Side as per drawing No. FD/E6/MAP/15(R) sheet No. 1/1
Table Centre as per drawing No. FD/MAP/08 sheet No. 1/1
Dressing Table including Stool as per drawing No. FD/MAP-II/07 sheet Nos 1/2 & 2/2
Chair dining JCOs/Ors as per drawing No. FD/MAP-II/05 sheet No. 1/1
Chair easy per drawing No. FD-229 sheet No. 1/1
Chair writing as per drawing No. FD-280 sheet No. 1/1
Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1
Mirror dressing(Gents) as per drawing No. FD/E6/MAP/16 sheet No. 1/1
Table dining 4 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1
Table with drawer (900 mm X 600 mm X 760 mm) as per drawing No. FD-283 sheet No. 1/1
Chair School with hand board as per drawing No. FD/E6/MAP/05 sheet No. 1/1
Note:-Quantities of materials given on standard drawings are for guidance only. The contractor shall work out the quantities of materials required for each item of BOQ and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. The drawing No's mentioned in BOQ item No 184 to 264 shall form part of tender document which will not be attached with tender document. The tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by AHQ, Engineer-in -Chief, New Delhi. For reference and guidance the tenderer may study and see these drawings in the any office of Garrison Engineer in MES before quoting their rates. No claim shall be entertained regarding misinterpretation of the drawings at a later stage.
Subtotal
Lump sum price worked out by the tenderer for “ARBORICULTURE WORKS" as listed in Schedule ‘A’ Section - XIV (Part-I)
Schedule 'A' Section -XIV (Part-II) (ARBORICULTURE WORKS)
Supply and planting of Hedge and Shrubbery (Anarmi, Ficus and the like) as directed by Engineer-in-Charge minimum 3 feet above GL including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with Sludge or manure in the ratio 8:1 (8 Part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed.
Supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engineer-in-Charge Note:- Tiles shall be approved by GE before incorporation in the work.
Material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.
Material and labour for construction and laying kerb stone of size as directed directly on the road construction site with automatic kerb casting machine (kerb, divider making/laying machine, Highway Engineering) using M-25 grade cement concrete laid in position to the required line, level and curvature, kerb stone casting continuously and making joints with or without groves (thickness of joints except at sharp curve shall not to more than 5mm), at a distance as directed including making drainage opening wherever required, including necessary excavation/ earthwork and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge
Supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.80 m or more above ground level, including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge or manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making Thaola all as specified and as directed by Engineer-in-charge. Note :- Contractor shall maintain the trees till physical completion of contract.Unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted.
Neem Tree.
Canerydate Palm
Gulmohar
Fruit Bearing Trees
Plumeria
Supplying plants Flower like Ticoma, rose,motia, Chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above GL including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1 (One part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 Km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making Thaola all as specified and as directed by Engineer-in-charge. Note :- Contractor shall maintain the trees till physical completion of contract.Unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted.
Supply and Fixing precast RCC 1:1.5:3 Type A1 lawn bench and back support of size 1.50 x 0.60m of maximum three person seating capacity supporting precast RCC type A1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia MS bar on concrete base (size 1.20x0.60m for each support) with 100mm thick PCC 1:2:4 Type B1 over 150mm thick sub base PCC 1:4:8 type D2 complete all as specified and as directed by Engineer-in charge
Supplying, fixing, testing,& commissioning integral decorative Water proof 9 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type complete all as specified and directed by Engr-in-Charge.
Supplying, fixing, testing,& commissioning single door SPN DB 2 way having facility to fix MCB DP/SPN 2 ways complete fitted with bus bars, neutral links including provision of MCB DP 6-16A and making good disturbed surface area complete all as specified and directed
Supply and FixingMCB suitable for 240 volts, AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 Amps all as specified and directed.
Subtotal
Schedule 'A' Section -XV (Maintenance of Arboriculture )
Material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 Nos (approx), Hedge and shruery - 520 RM (approx) and Grass - 4000 sqm( approx)
Subtotal
Schedule 'A' Section -XVI (Three year Comprehensive Maintenance)
Supply and fix in repairs aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixedwith aluminium wire staples etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet glass ordinary quality and glazing with rubber packing around the glass,i in squares not excedding 0.50 sqm in each pane 4 mm thick plain glass in old windows including hacking out old complete all as specified and directed by Enginer-in-charge.
Supply and fix figured glass,pin headed type ordinary quality and glazing with rubber packing around the glass,i in square not excedding 0.50sqm in each pane 4 mm thick plain glass in old windows including hacking out old samples all as specified and directed by Engineer-in-charge.
Supply and fix in repair butt hinges,100 mm length B-21 type extruded stainless steel with galvanised mild steel hinge pin ,anodised and fixed ,complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repair butt hinges,75 mm length C-22 Type extruded stainless steel with galvanised mild steel hinge pin,anodied and fixed ,complete all as specified and directed by Engineer-in-charge.
Supply and fix in repair 150 mm long aluminium, anodised barrel tower bolt of extruded section,complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair 125 mm long aluminium, anodised barrel tower bolt of extruded section,complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair decorative /fancy designer SS drapery rod 20 to 25 dia fixing to wall with suitable brackets etc. Complete all as specified and directed.
Supply and fix in repair decorative /fancy designer SS brackets suitable for decorative drapery rod 20 to 25 dia etc. Complete all as specified and directed.
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc.
Material and labour for 10mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
Demolition of cement concrete in ground floors and pavings not excedding 15 cm thickness (below or above ground level) as in plinth protection etc complete all as specified and as directed by Engineer-in-charge.
Materials and labour For 75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate as in plinth protection,pavings,laid in panels and finishing fair and even,including necessary formwork complete all as specified and as directed by Engineer-in-charge.
Disconnecting of existing tank of capacity 500 litre and setting aside or lowering if required for repairs cleaning etc.and refixing in position hoisting and connecting, complete all as specified and as directed by Engineer-in-charge.
Materials and labour for painting with one coats of acrylic emulsion paint with 3 mm thick wall putty of internal walls including necessary preparation of old surfaces complete all as specified and as directed by Engineer-in-charge.
Material and labour for applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified.
Material and labour for applying three coat of white wash on newly plastered or unplastered wall surfaces including preperation of surfaces, complete all as specified.
Material and labour for Preparation of new plastered surfaces wall and pillar and applying two coats of exterior grade wall putty and making it smooth with sand paper by mechanical method then applying two coats of weather proof exterior emulsion over a coat of exterior primer complete, by mechanical means as per manufacturer's specification complete all as specified and directed.
Material and labour for preparation of new surfaces of walls incl pillar etc. and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturer's specification complete all as specified and directed.
Material and labour for complete removal of existing treatment and applying two coats of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
Material and labour for complete removal of existing treatment and applying two coats of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
Material and labour for Preparation of Old plastered surfaces by removing old treatment and applying two coats of exterior grade wall putty and making it smooth with sand paper by mechanical method then applying two coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying one coat of weather proof exterior emulsion on old decorated or undecorated wall surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified
Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge .
Supply and fix as in repairs butt hinges,100 mm length B-21 type extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,complete all as specified and directed by Engineer-in- charge.
Supply and fix as in repairs butt hinges,75 mm length B-12 type extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,complete all as specified and directed by Engineer-in- charge.
Supply and fix as in repairs 300 mm aluminium alloy ,anodised,sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet,cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy complete al as specified and directed by Engineer-in-charge.
Supply and fix as in repairs 150 mm size handle extruded aluminium alloy anodised,fabricated type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix as in repairs 100 mm size handle extruded aluminium alloy anodised,fabricated type,complete all as specified and as directed by Engineer-in-charge.
Supply and fix as in repairs 140 mm long door stopper of aluminium alloy body and tongue,anodised with hard drawn steel spring fixed in floor complete all as specified and as directed by Engineer-in-charge.
S&F in repair MS 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
Supply and fixed rotational moulded polythene water storage tank ISI marked (cylinderical vertical with closed top) of 500 litre capacity withtank,cover (top) ,hoisted and fixed in position ,including taking down existing with all connection complete allas specified anddirected by Engineer-in-charge.
S & F in repairs 20 mm dia nipple of PTMT any colour,suitable for HDPE watertank,min weight 38 gms, complete all as specified and as directed by engineer -in-charge.
S & F in repairs 25 mm dia nipple of PTMT any colour,suitable for HDPE watertank,min weight 65 gms, complete all as specified and as directed by engineer -in-charge.
S & F in repairs 20 mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, nipple of PTMT ,min weight 142 gms, complete all as specified and as directed by engineer -in-charge.
S & F in repairs gun metal globe or gate valve,40 mm dia ,screwed down high pressure with iron wheel head,screwd both ends for iron pipe or for union complete all as specified and as directed by engineer -in-charge.
Supplying and lying CPVC pipes of 20 mm outer dia SDR 11 Aand plain CPVC SDR 11 fittings on walls/ceilings or laying in floors and including taking up or down old pipe of any type complete all as specified.
Supplying and lying CPVC pipes of 25 mm outer dia SDR 11 Aand plain CPVC SDR 11 fittings on walls/ceilings or laying in floors and including taking up or down old pipe of any type complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing the rubbish off the permises complete all as specified and as directed by engineer -in-charge.
Material and labour for Non skid ceramic coloured /printed tiles (joint free) 7 to 8 mm thick (square /rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm and shall be jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tilesincl screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed by Engr in Charge.
Material and labour for Non skid ceramic coloured /printed tiles (joint free) 7 to 8 mm thick( square /rectangular) area of each tile exc. 0.18 sqm but n. exc, 0.38 sqm and shall be jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tilesincl screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed by Engr in Charge.
Material and labour for glazed ceramic coloured tiles (joint free) 7mm thick 300 x 600mm as in dado/skirting set and jointed in neat cement slurry and pointed with coloured cement to matchthe colour of tiles over and including rendering 10mm thick CM (1:3) on wall surfaces complete all as specified and directed by Engineer - in - Charge.
Demolation of ashlar facings, dressed stone work, stone slabs or tiles from paving and precast concrete blocks and articles complete all as specified and directed
Material and labour for 18-20 mm thick granite stone (of any type and coloured in single piece) work (table rubbed and polished ) in steps,jambs,pillars,window cills,flooring,cooking platform machine cut,bedded and jointed with grey cement slurry and pointed with white cememt with admixture of pigment to match the side of granite including griding and polishing and rounded on edges types over and including screed bed 20 mm thick in CM and like in cm (1:4) complete all as specified and directed by engineer-in-charge.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.pressure process with grey cement and no pigment laid over and including 50mm thick sand cusion complete all as specified and directed by engineer-in-charge.
S & F in repair brass chromium plated tubular tower rail,20mm dia ,D type, 60 CM long between flanges including suitable bracket complete all as specified and directed .
S&F in repair Viterous China wash down wall mounted water closet pan with superior quality,health faucet and incl connection to drain or out going pipe and concealed flushing pipe cistern and flushing pipe etc.and incl plastic sheet cover white anodised hinging device incl fixing bolt and taking out old EWC complete all as specified and directed.
S&F in repairs brass chromium plated wall 3 in 1 single lever 3 inlet diverter mixer (both concealed and exposed part) with for mixing hot and cold water screwed down for iron pipe and fixed as directed by Engr-in-charge:make: Jaquar Cat Part No. ALI-CHR-85193K or equivalent.
S&F in repair PVC concealed type flushing cistern set of capacity 10 ltr with half frame including all fixing accessories and knob fixed in wall and including flush pipe of PVC 32mm bore and connection to WC pan making good dismantled portion of wall complete all as specifed and directed. Make:Cera cat part No B1110112 or equivalent
S & F in repair 32 mm brass chromium plated bottle trap for washbasin with inlet and outlet screwed for pipe or connection incl necessary packing union and cap complete all as specified and directed .
S&F in repair Viterous China wash hand basin of size 550*400mm white flat back including chromium plated pillar tap,32mm waste coupling of PTMT (half or full threaded)(minimum wt 32-45gm/ 40-60 gms),including brackets,PVC waste pipe,incl cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed.
S & F in repairs angle cock (two way type) ,cast copper alloy, high pressure ,screwed down, with crtuched or butterfly handle,screwed both ends for 15 mm dia iron pipe or for union and fixed completed all as specified.
S & F in repairs angle cock (fancy type) cast copper alloy, high pressure ,screwed down, with crtuched or butterfly handle,screwed both ends for 15 mm dia iron pipe or for union and fixed completed all as specified.
S & F in repairs 15 mm size PVC connection with C P brass nuts of length 450 mm , completed all as specified.
S&F in repairs 15mm bore pillar tap (fancy type) cast copper alloy with capstan heads,chromium plated screwed down, high pre-ssure with or without lettered hot or cold with long screwed shank and flynuts screwed for iron pipes complete all as specified and directed.
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repairs soap dish,chromium plated, 100X100X60mm, fixed to wall with plugs with chromium plated screws complete all as specified and directed.
S & F in repair brass chromium plated toilet paper holder recessed type,complete all as specified and directed .
S & F in repair brass chromium plated RO nozzel for 15mm bore pipe complete all as specified and directed .
S & F in repair pvc waste pipe, 32mm/40mm dia,for WHB,sink and urinal,complete all as specified and directed .
S & F in repairs long body bib tap,cast copper alloy chromium plated,15mm dia with fancy type screwed down for iron pipes or brass ferrule etc. complete all as specified and directed .
Supply and fix in repair only brass spindle suitable for wall and sink mixer of make of Jaquar of suitable size as required at site as per sample approved by GE.
Supply and fix in repair only brass brass chromium plated water tap handle or knob of make of Jaquar of suitable size and specification as required at site and as directed by Engr-in-charge.
S&F in repairs sink made of stainless steel,1 mm thick for kitchen or laboratory with plugs,washers and wastes fittings; including bedding in cement mortar 1;3 to dwarf wall or cantilever brackets and connecting union to pipe ,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc. complete all as specified and directed .
S & F in repair plastic water closet seat cover pvc waste pipe,complete all as specified and directed .
S & F in repairs shower arm 15 mm size,195 mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and directed .
S & F in repairs brass chromium plated shower rose 125 mm size, with swivel joint, fixing to steel pipe or union complete all as specified and directed .
Demolition of AAC block walling,built in cement mortar incl all quoins,arches,pillars etc. complete all as specified and directed .
Materials and labour for AAC blocks masonry solid blocks and set in CM 1;6 complete all as specified and directed .
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
M & L for PVC (SWR) PIPE 110mm bore double socketed in any length with rubber ring joints fixed to walls incl testing of pipe etc. complete all as specified and directed.
M & L for PVC (SWR) PIPE 75 mm bore double socketed in any length with rubber ring joints fixed to walls incl testing of pipe etc. complete all as specified and directed.
S & F for PVC (SWR) bends 110mm bore with oval access doors . complete all as specified and directed.
S & F for PVC (SWR) bends 75mm bore with oval access doors . complete all as specified and directed.
S & F for PVC (SWR) junction single,(single T) 110mm bore ,equalor unequal with oval access doors . complete all as specified and directed.
S & F for PVC (SWR) junction single,(single T) 75mm bore ,equalor unequal with oval access doors complete all as specified and directed.
S & F for pvc (SWR) branch piece, single,(single Y) 110mm bore ,equalor unequal with oval access doors . complete all as specified and directed.
S & F for pvc (SWR) branch piece, single,(single Y) 75 mm bore ,equalor unequal with oval access doors . complete all as specified and directed.
Materials and labour for cleaning/removal of blockage from bathroom,kitchen,WHB,EWC,IWC, urinals etc. incl connected Nahani traps/gullytraps/floortraps,grating of trap,waste pipes,pipe in any length upto 1st manhole etc chocked with mud/other accumulated sludge and getting out , washing throughly at any location,at any floor by rodding/choke remover/pressure technique/manually or othetrwise to clear blockage upto including refixing of oval assess door covers with new nuts and washers and refixing manhole covers,incl removal of all wastes, solid or lkiquid sludge and depositing the sludge in apit (at empty /open area) of suitable size at a distance excedding 50 metre from the building where directed and covering the same withthe soil obtained from.
M & L for cleaning of existing sewage system 100/150/200 mm dia (lengthof pipe line manholeto manhole not excedding 20 metre) incl cleaning of manholes (any type rectangular/square/circular) located in different sites, taking offthe manhole cover (CI or RCC) and placing in thesame original position after gettingout liquid/sludge/solid contentfrom the manholes andcompleteperfect flowing conditiom without any obstruction by removing all blockage in system with manual labour or by mechanically sewage suction pump (at contractors discretion asrequired at site ) making it fully functional to the entiresatisfaction of engineer-in-charge inclremoving of all wastes, solid or liquid sludgethrough closed container and depositing the sludge in apit (at empty/open area) of suitable size at any distance upto20 metre from the line.
Note for item No 237 & 238:- (i) Contractor or his representative shall report daily at 09:00 AM except on Sunday/ National Holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05:00 PM of every working day to JE/Engineer-in-Charge. (ii) In case of non attandence of complaints against BOQ item 237 & 238 above by the contractor on the same day, a penalty of Rs 200/- per complaint per day shall be recovered from the contractor's dues. (iii) The const for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching poweder etc and all other materials for execution of the work shall be included in the unit rate.
Cleaning and desilting of sewage lines 150mm to 250mm dia of any size of any depth by pumping out / removing liquid waste/ sewage, plugging the ends pipes or diverting the flow into drains if necessary , removing silt, sludge etc, sprinkling bleaching powder on the silt to avoid bad smell including all precautionary and safety measures such as safety belts, lighting arrangements face mask etc and removing the same (silt,sludge & other waste material) in leak proof trucks covered with tarpoline all as per existing rules and regulations of civil authorities and flushing the sewer lines with fresh water etc complete all as specified and directed by Engineer-in-Charge.
Cleaning and desilting of manholes depth not exceeding 1.50 meter by pumping out /removing liquid waste/ sewage and plugging the ends of sewer pipes or diverting the flow into drains if necessary, removing silt , sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same (silt,sludge & other waste material) in leak proof trucks covered with tarpoline all as per existing rules and regulations of civil authorities and cleaning the manholes with fresh water etc complete all as specified and directed by Engineer-in-Charge. Note:- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
Cleaning and desilting of manholes depth not exceeding 1.50 meter but not exceeding 3.00 meter by pumping out /removing liquid waste/ sewage and plugging the ends of sewer pipes or diverting the flow into drains if necessary, removing silt , sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same (silt,sludge & other waste material) in leak proof trucks covered with tarpoline all as per existing rules and regulations of civil authorities and cleaning the manholes with fresh water etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers for paino type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch/socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per Item No.244 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (switch/socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per Item No.244 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (switch/socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per Item No.244 above here in before but for One light point controlled by two 2-way switches of 5 amps complete all as specified and directed. (switch/socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
Description all as per item No.244 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate.
Supply only modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply only modular switch 5/6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply only modular Bell Push switch, 5Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply only modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply only modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply only modular Fan regulator, single pole, one way complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
S & F Bell ding dong AC, 230 Volts, Single pole complete all as specified.
Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric lamp 9 Watt with backalite 20mm back plate complete all as specified & directed, .
M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete,
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 10 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No.259 above here in before but 2 Runs of 6 sqmm complete in PVC conduits/ complete all as specified.
Dismantling of existisng unserviceable MCB distribution board and S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Dismantling of existisng unserviceable MCB distribution board and S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing complete set of 1x10 watt LED retrofit type bulkhead fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge.
Material and labour for 2mm thick galvanised steel presses sunken box suitable for both paino type fitting and modular switch socket (min 60 mm deep, suitable length) grouted flush to walls and necessary cement work of cm 1:4 and applying putty around 3mm thick switch board to match with existing surface and provision of suitable hylem sheet of 3mm thick (ISI Marked) fitted with Chromium plated brass screws & washers for paino type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc. Fixing existing serviceable modular/panio type switch, socket, regulator for any type of concealed point wiring complete all as specified and directed. Note: 1. Replacing Old unserviceble switch, socket regulator if any with new is measurable in sepearte items 2. Modular base and cover plate for fixing of modular accessories supplied suitable for as per sch "B" items.
S&F and testing of warm LED light fitting 1x20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin.
Supply and fixing LED light fitting 1 x 8/10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S & F LED backup/Rechargeable tube light polycarbonate housing 1x18/20 watt, appx 4 feet long module complete all as specified and directed
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 to 63 Amps all as specified and directed.
Supply and fixing MCB ‘B’ curve suitable for 415 volts AC supply, 16 to 32 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing Air freshener fan PVC body, AC single Phase 230V, 50 Cycle per second, size 250mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- old/unsv Exhaust fan shall be deposited to BSO Yard, AGE E/M store.
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after rewinding with copper winding including necessary cleaning, oiling, greasing, servicing/overhauling and replacement of bushes, bearing, condenser, down rod, canopy etc complete all as specified and directed and writing MES number as as directed by Engr-in-Charge.Note:-pair/Servicing of fan shall be carried out in MES yard/User site to bring adequate serviceable condition winding machine,tools & plants and necessary motor winder at site as directed.
Supply and fixing in replacement of PCB (Panel circuit board) suitable for BLDC ceiling fan of 1200 mm sweep ISI marked duly housing in side ceiling fan body after taking down and fixing the ceiling fan after serviceble position complete all as specified and directed.
Subtotal
GEMINI PROMOTERS AND BUILDERS PVT. LTD. (BID ID -3354994)
M/s DMR Builders Pvt Ltd (BID ID -3356833)
BANSI BUILDER AND CONTRACTORS PVT LTD (BID ID -3363457)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid