Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹39.7 L+₹3,300 (0.08%)Rejected-Finance 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L2 | Rejected-Finance Highest bidder | |
| 3 | L3₹39.9 L+₹25,313 (0.64%)Rejected-Finance | L3 | Rejected-Finance Highest bidder | |
| 4 | L4₹40.7 L+₹1.1 L (2.68%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance Highest bidder | |
| 5 | L5₹41.5 L+₹1.8 L (4.62%)Rejected-Finance | L5 | Rejected-Finance Highest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Jul 2020, 6:00 pmClosed
GE AF Bamrauli
GE AF Bamrauli
PROVN OF SHED FLOOR CERTAIN BR SERVICES NEAR BLDG NO P159 T69 P29 AND T36 INCLUDING SACNTIONED WORK AT NORTH CAMP BAMRAULI
2020_MES_352019_1
8568/E8
Open Tender
Civil Works
Item Rate
180 days
Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Bamrauli
₹80,000
Yes
6 Aug 2020
11 Jun 2020
8 Jul 2020
11 Jun 2020
6 Jul 2020
29 Jun 2020
Amount
Dismantling of floor any type, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for non-skid ceramic coloured tiles (400x400 mm ), 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc laid over 15 mm screed bed in cement mortar 1:6 and set and jointed in neat cement slurry and pointed in white and coloured cement complete all as specified and directed.
M&L for non-skid ceramic coloured tiles (400x400 mm ), 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting etc laid over 10 mm screed bed in cement mortar 1:4 and set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed.
Taking down chowkhats or frames not exceeding 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed.
Description same as per above but exceeding. 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down shutter of any description, exceeding. 1 Sqm but not exceeding 2 sqm each complete all as specified and directed.
S & F mild steel framed work such as door frame, grills, grating hold fast etc. with ends of bar shoulder and/or riveted, or forged into spikes, framed guard bar including necessary welding, drilling hole etc complete all as specified and directed.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete as specified in SSR Pt I-2009 section 8 clause 8.24 (a) complete all as specified and as directed.
S & F factory made steel window with side hung shutter including box type hinges with steel handle, steel peg stay, hold fast, complete with glazing bar, dovetailed or welded complete all as specified and as directed.
S & F factory made steel window with side hung shutter including box type hinges with steel handle, steel peg stay, hold fast complete with MS flat for fixing wire mesh, dovetailed or welded complete all as specified and as directed.
Supply only 3 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and as directed. Note :- Fixing only rate is included in window/door shutter items
S&F factory made Steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and as directed.
Supply only rough cast, pin headed figured glass, 3mm thick and glazing with oil putty not exc 0.5 sqm each pan etc complete all as specified and as directed
Supply & fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire stapples etc complete all as specified and directed.
S & F 125X60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F 100mm butt hinges, medium wieght, cold rolled mild steel complete all as specified and directed.
S&F 100mm Aluminum hinges, complete type B-21 complete all as specified and directed.
S & F 200 mm long aluminium anodised barrel tower bolts ISI marked of extruded section and fixed complete all as specified and directed.
S & F 150 mm size aluminium handles 'D' Type ISI brand cast type, anodised complete all as specified and directed.
S & F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint on new or old wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint on new steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
S & F in repair 25 mm dia MS curtain rod, PVC coated with a pair finull & with brackets fixed with 65mm long screw with rawl plug , approved by GE complete all as specified and directed.
S&F in repair tubular towel rail 20 mm dia, D type 60 cm long between flanges brass chromium plated complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class 'B' brick straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down existing cement plaster in any position including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for 15 mm thick rendering in one coats on brick work or concrete surface in cement mortar 1:6, surface finished even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3 top surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 thick rendering on surface other than fair faces on brick wall or stone wall in CM 1:4 finishing the surface fair and even including preparation of surface complete all as specified and directed.
M & L for repairing of RCC projection, chajjas, roofs facia, column etc by necessary preparation i.e scrapping, cutting, chiseling and cleaning exposed reinforcement, surfaces of damaged, loosed RCC srfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.50mm graded stone aggregate and reinforced with welded mesh of weight exc 2kg per Sqm but not exc 3kg/sqm with or without facia and finished exc 5Sqm each and thickness of RCC using coarse sand in patches area not each and thickness of RCC member n exc 70mm at any height complete all as specified and as directed. Note : Cost of formwork and welded mesh shall be deemed to be included.
M&L for preparation of new plastered surfaces of walls and distempering with distemper oil emulsion , two coats, white or tinted over a coat of alkaline resistant primer including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
M&L for preparing old cement base painted (distempered) surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and applying two coats with cement base paint , white or tinted including and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and directed.
M&L for preparation of new plastered or unplastered surafces of ceilings and applying three coats of white wash on ceiling including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
M & L for applying two coats of white wash on old ceiling including preparation of surfaces complete all as specified and as directed.
M&L for applying two coats with cement base paint on new surfaces, white or tinted over one coat of cement paint primer ( before application of cement base paint) on walls including preparation of newly plastered surfaces, washing floors, etc. , of drops and splashescomplete all as specified and as directed.
Taking up or down existing steel tubing and connection and removing complete for 15 mm dia complete all as specified and as directed.
Supplying, fixing, jointing and testing galvanised steel water tubing for 15mm dia bore medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors,etc complete all as specified and as directed.
Demolition of cement concrete un reinforced in ground floors and pavings n. exc 15cm thick (below or above ground level ) complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and directed.
S&F in repair brass bib cock ,cast copper alloy with butterfly handle, screwed down screwed for iron pipe or for brass ferule of 15mm bore complete all as specified and diected.
S&F in repair stop valve cast copper alloy screwed down high pressure with with butterfly handle, screwed down, screwed for iron pipe or for brass ferule of 15mm bore or for unions and fixed complete all as specified and diected.
S&F in repair PVC conections 15mm dia for wash hand basin and low level flushing cistern of 450 mm length PTMT nuts at ends to connect pipe or sanitary fitting complete all as specified and directed.
S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including bracket with 32 mm dia PVC pipe 600 mm long complete all as specified and directed.
S & F in repair MS powder coated peg set of six complete all as specified and directed.
S & F in repair stainless steel plate rack of approved quality complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in leveling course to floor complete all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth with using extra cement complete all as specified and directed.
Supply only 3 mm thick and 38 mm wide glass dividing strip complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, sub base / mass concrete etc. complete all as specified and directed.
M & L for glossy chequred cement concrete tile 25 cm x 25 cm x 22 mm thick, set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
S&F steel work in hollow structural pipes as in Rafters/purlins and trusses special shaped washer incl clamp and bolt complete using ERW or induction but welded tubes comprising to IS complete all as specified and directed.
S&F steel work in tubular trusses/tubular pipes as in post including special shaped washer etc complete using ERW or induction butt welded tubes complete all as specified and directed.
M&L for 75 mm thick cement concrete type C-2, 1:3:6,using 40mm graded stone agg as in plinth protection, finished concrete surface even & smooth without using extra cement complete all as specified and directed.
M & L for 20 to 25 mm thick machine cut Kota stone slab flooring, Landing,steps and plateform over and including 20mm thick screed bed in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and grinding and polishing to achive mirror finish complete all as specified and directed.
M & L for 20 to 25 mm thick machine cut Kota stone slab on vertical surfaces such as skirting, risers of step, dado etc over and including 10mm thick bearing plaster in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and granite polishing complete all as specified and directed.
S&F 18mm thick celuka PVC sheet minimum 600 Kgbm density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet complete as per specifications and as directed. Note:- (i) Cup board accessories ie fittings, handles, hinges, will be measured and paid under this schedule. (ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type). (iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensil strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensil strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around. In layers not. Exceeding 25cm, for hard/ dense soil complete all as specified and directed.
S&F plain Aluminium 0.71 mm thickness sheeting Alloy 31000H4 in valley gutter drip and straight flashing (length and girth and fixed) complete all as specified and directed.
S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases splices angle brackets cleats and other connections complete all as specified and directed.
PCC 1:2:4 type B-2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete for post holes.complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer birla white care Putty on wall obtain smooth finish etc including balance area including remova complete all as specified and directed.
S&F premium sand textured finished mineral fibre acoustical ceiling tiles of size 600x600x16mm thick and placed on GI grid powder coated snap grid ceiling 600x600 module consisting of wall angle section 24x24mm and tee section with web height of 38mm and flange 24mm and cross T 24mmx24mm size with suspension system complete all as per TD drg No CWE/BAM/TD-34 dated 29 Sep 2016 and directed. Note: (i) Ceiling tiles shall be of make Armstrong brand "DUNE RH99 (Bevelled/Tegular) or equivalent brand
S&P POP false ceiling over GI snap grid permiter wall channel 25x25m fixed on wall all round, GI main ceiling channel with flange 50x25mm @ 250mm C/C, cross GI channel section 25x12 mm @ 750 C/C alongwith the suspenders of GI angle 25x25 mm @ 1200 mm C/C. The 20 to 25 mm thick POP lath pastering over n. less than 0.56 mm thick wire gauge in complete ceiling incl form work. Ration of POP and wall putty (1:10) and applying two coats of oil bound distemper including chalk whitening and priming in alkali restant with preparing the surface complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B-0 using 20 mm graded stone aggregate as in leveling course to floor complete all as specified and directed.
S&F homogenous vitrified drak coloured flooring tiles 10mm thick of polished area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm in floor etc, laid in floors with cement based adhesive , set an adjointed as per manufacture's instruction over and including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
S&F homogenous vitrified drak coloured Wall tiles 10mm thick of polished area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm in wall etc, thick on vertical surfaces such as skirting, dado and rises to steps etc., set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles fixed over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L 80mm thick interlocking tiles (glossy finish) rubber moulded of M-40 mix laid, jointing and pointed in neat cement slurry over dry sand cushioning 30mm thick and edges shall be secured with PCC 1:2:4 type B-0 complete all as specified and as directed. Note : Sand cushioning shall not be measured separately.
M & L for non-skid Heavy duty endura tile 300x300x10mm thick coloured joint free in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:4 complete all as specified and directed. Make :Johnson Endura/ Somany or equavalent
M & L for non-skid Heavy duty endura tile 18 to 22 mm thick area exc 0.13 but not exc 0.20 Sqm coloured joint free in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:4 complete all as specified and directed. Make :Johnson Endura/ Somany or equavalent.
Excavating over areas, not exceeding.1.5m deep and in any type of soil and getting out complete all as specified and directed.
Removing excavated material exceeding. 250 m but not exceeding 500 m and depositing where complete all as specified and directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for including cutting reinforcement as required to facilitate demolition complete all as specified and as directed.
M & L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No -78 but 6 to 8mm dia all as per specified and directed.
M & L for reinforced cement concrete (nominal mix), in cement concrete 1:2:4, type B1 using 20mm graded stone aggregate as in chajjas complete all as specified and as directed. Note:- Reinforcement as required shall be measured and paid for separately.
S&F Aluminium Door (Powder coated ) single/double leaf with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of "Godrej or Link 7 lever self closing device with rebate including joints cleat fixing of builders hardware fittings necessary numbers of floor spring and gazing with 5.5mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads complete all as specified and as directed.
S&F Aluminium window (Powder coated ) double leaf with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of rebate including joints cleat fixing of builders hardware fittings necessary and gazing with 5.5mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads complete all as specified and as directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
Surface dressing in soft/loose soil n exc 15 cm deep complete all as specified and as directed.
Removing excavated soil not exc 50m and depositing where directed at a level not exc 1.50m above the starting point.complete all as specified and as directed.
M & L for 100 mm thick PCC 1:2:4 type B-2 (Using 40mm graded stone aggregate) as in flooring finished concrete surface spike rolling to surface or making impressions of expanded metal, whilst the concrete is green.complete all as specified and as directed.
S&F Factory made sheet metal enclosure distribution boards, (protection class IP-65) double door, vertiical type suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, SP and N, 12 ways, 240 volts complete all as specified and as directed. Note : MCBs shall be measured and paid for separately
S&F MCB, single pole and neutral, 230 volts, 35 to 60 Amp rating, 'C' series fixed in DBs complete all as specified and as directed.
S&F MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs . complete all as specified and as directed.
S&F MCB, SP, 230 volts, 35 to 63 Amp rating, 10 KA, C series fixed in DBs .complete all as specified and as directed.
M & L for point wiring with 1.5 sqmm (Nominal Area) FR-LS PVC insulated sheathed multi stranded copper conductor, 1100 Volts grade through PVC conduit medium duty (ISI Marked) concealed with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting Modular type switches, sockets, fan regulators etc top cover (ISI marked) including continuous earth wire FR-LS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following : Note :1 Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. 2 The rate included for suitable sunken metal flush boxes, cover plates, blank plates etc for placing modular fittings etc
(a) One light point/ fan/exhaust point controlled by one switch
(b) One three pin socket outlet on independant board
(c) One three pin socket outlet on same board
M & L for point wiring with 4.0 sqmm (Nominal Area) FR-LS PVC insulated sheathed multi stranded copper conductor, 1100 Volts grade for 3 Pin socket outlet 15 Amps on independent board through PVC conduit medium duty (ISI Marked) concealed with accessories such as elbow, tees,internal & external bend etc. of suitable size including MS pressed steel cadmium plated terminal box of 1.6 mm thick for mounting modular type switch socket combination and top cover including continuous earth wire FR-LS PVC insulated 4.0 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and as directed. Note : 1 Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. 2. The rate included for suitable sunken metal flush boxes, cover plates, blank plates etc for placing modular fittings etc
Supply and fix modular switch 6Amps, 1 module complete all as specified and as directed.
Supply and fix modular switch 16Amps, 1 module complete all as specified and as directed.
Supply and fix modular socket outlet 6Amps, 2 module complete all as specified and as directed.
Supply and fix modular socket out 16Amps, 2 module complete all as specified and as directed.
S&F ceiling rose surface bakelite 65x50mm Three terminals, 240 V grade complete all as specified and as directed.
S&F in replacement of LED fitting of 21 watt 4 feet long integral sleek extruded aluminium housing LED channel with white acrylic cover wall mounted type including making connection and depositing the same in MES store yard for checking of serviceability by AGE complete all as specified and as directed Make : Philips cat no BN021C LED20S PSU CDL GR /Havells, Cat No HEWEBP7IN1W020/Crompton cat no LCCLB20-CDL
Supply and fix 2x2 feet size 36 watt 240 volt 50 Htz LED luminaries with high transmitive diffuser suitable for indoor spaces aluminium housing including making connection complete all as specified and as directed. Make Bajaj cat part No- BCTBLL 36W LED or Philips cat part No-RC380BLED36S - 6500 or equivalent in Havells/CG
Supply and fix bulkhead fitting 10 watt enviornmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulkhead edgelit LED luminaire comprising of high brightness including making connection complete all as specified and as directed. Make LEDs of 10 watt Havells cat part No- Rugby Neon 10WLED760SSYMBOPC or equivalent of other make Bajaj/Crompton
M & L for Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit not less then 20mm dia bore including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed. Note:- (a) Two runs of 6.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply and fix AC starter unit consisting of one 25 Amp capacity starter, one 240 volt 25 Amp 10 KA SPN MCB, one 25 Amp sockets and one 32 Amp plug top prewired complete all as specified and directed. Make North west/Anchor/Legrand
M & L for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire.
M & L for wall mounted fan, 450 mm sweep, AC, single phase, 230/240 Volts, fixing on wall all as required and connecting with 3 run of 1.5 sqm single core PVC insulated mulstistranded copper conductor cable from ceiling rose.complete all as specified and directed. Make : Havells, model 'V3' or equivalent
Supply and erecting ceiling fan 1200mm sweep with all standard accessories and necessary materials, erected in provided hook/clamp. Material : ceiling fan : electric Ceiling fan capacity type with double ball bearing complete with capacitor, 300 mm down rod, canopies, shackeles, reel insulator, half threaded bolts of 9.53mm (3/8") dia 62.5 mm (2-1/2") to 88mm (3-1/2") long and 7.94 mm (5/16") dia 44.5 mm (1-3/4) to 57 mm (2-1/4") long with nuts, with lock type split pin spring & plate washers etc, three number blade made of Aluminium alloy suitable for single phase, AC 210 volts, 50 Hz supply and conforming to class I to IS : 374/1979 with amendment no 1 to 6 expect for performance parameters to the extent modified as details in general requirements > the down rod shall be capable to withstand a tensile load of 1000 kg without break down and a torsion load of 500 kgcm without breakage as per clause 10.14.1 of IS : 374/1979 with amendment no 1 to 6 Eletrical motor should be single phase permanent capacitor type with no. of pole 12/14/16/18(as per sweep). Class-1 wih basic insulation. class of insulation shall be B class. The binding wire used for fan should be copper wire, synthetic enameled of 30 to 38 SWG. Connection wire : Flat/round two core flexible stranded copper wire cord 23/0.2 mm ISI marked. Paint superior quality enamel paint of specified colour for marked Sr . No and date of erection of 1200mm sweep, maximum input power 50 watts air delivery 215 cubic meter per minute complete all as specified and directed. Make USHA/CROMPTON GREAVES/HAVELLS/BAJAJ/ORIENT.
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, socket or power) including all fittings such as switches, socket, ceiling roses and fittings complete and making good the disturbed surfaces complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (Nominal Area) FR-LS PVC insulated sheathed multi stranded copper conductor, 1100 Volts grade through PVC conduit medium duty (ISI Marked) concealed with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc on 3 mm thick bakalite sheet top cover (ISI marked) including continuous earth wire FR-LS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following : Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. The rate included for suitable sunken metal flush boxes, cover plates, blank plates etc for placing modular fittings etc
(a) One light point/ fan/exhaust point controlled by one switch
(b) One three pin socket outlet on independant board
(c) One three pin socket out let 5 Amp on same board
M & L for point wiring with 4.0 sqmm (Nominal Area) FR-LS PVC insulated sheathed multi stranded copper conductor, 1100 Volts grade for 3 Pin socket outlet 15 Amps on independent board through PVC conduit medium duty (ISI Marked) concealed with accessories such as elbow, tees,internal & external bend etc. of suitable size including MS pressed steel cadmium plated terminal box of 1.6 mm thick for mounting switch socket combination and 3 mm thick ISI marked laminated sheet top cover including continuous earth wire FR-LS PVC insulated 4.0 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed. Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. The rate included for suitable sunken metal flush boxes, cover plates, blank plates etc for placing modular fittings etc
Supply and fix switch 6 Amps 240 volt complete all as specified and directed.
Supply and fix switch 16Amps, 240 volt complete all as specified and directed.
Supply and fix socket out 6 Amps, 2 module complete all as specified and directed.
Supply and fix socket out 16 Amps,complete all as specified and directed.
Supply and fix batten holder with 10 watt LED bulb complete all as specified and directed.
Supply and fix in replacement of sheet metal enclosure single pole and neutral 4way double door complete all as specified and directed.
Supply and fix in replacement of MCB SPN 240V 32 Amps capacity complete all as specified and directed.
Supply and fixing LED fitting of 21 watt integral sleek extruded aluminium housing LED channel with white acrylic cover wall mounted type including making connection complete all as specified and as directed Make : Philips cat no BN021C LED20S PSU CDL GR /Havells, Cat No HEWEBP7IN1W020/Crompton cat no LCCLB20-CDL.
Supply and fix Modular type fan regulator electronic Step type, 240 volts, complete all as specified and as directed.
Supply and fix bulkhead fitting enviornmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulkhead edgelit LED luminaire comprising of highbrightness LEDs of 10 watt including making connection crompton complete all as specified and as directed Make Cat part No- LBHP-10-CDL or equivalent of other make Philips/Bajaj
Supply and fix 1100 volt 16 sqmm two core grade heavy duty service cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and overall PVC sheathed in service connection duly fixed in PVC conduit on wall complete all as specified and as directed
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
Z N Enterprises
M/S Shivam Industries
Mohit Enterprises
M/S SWASTIK BUILDERS
VIPUL CONSTRUCTIONS
chauhan construction
MOHAMMAD RIZWAN CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .