Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.7 LQualified Make: FLUKE
Model: Fluke 1732 Three-Phase Electrical Energy Loggers 205 TSL PLAZA PLOT 9 SECTOR 6 DWARKA SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | Make: FLUKE
Model: Fluke 1732 Three-Phase Electrical Energy Loggers | ₹2.7 L | L1 | Qualified |
| 2 | L2₹2.8 L+₹2,700 (0.98%)Qualified Make: FLUKE
Model: Fluke 1732 Three-Phase Electrical Energy Loggers COLLECTOR SIVAKUMAR STREET COIMBATORE COIMBATORE TAMIL NADU 641038 | COIMBATORE | TAMIL NADU | 641038 | Make: FLUKE
Model: Fluke 1732 Three-Phase Electrical Energy Loggers | ₹2.8 L+₹2,700 (0.98%) | L2 | Qualified |
| 3 | Disqualified Make: KRYKARD
Model: Power Quality Analyzer KRYKARD ALM 20 NO 5 KUMARAN STREET PAZHAVANTHAGAL CHENNAI CHENNAI | Make: KRYKARD
Model: Power Quality Analyzer KRYKARD ALM 20 | - | - | Disqualified |
| 4 | Disqualified Make: FLUKE
Model: FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER 212 AGARAWAL CITY SQURE MANGALAM PALACE ROHINI SECTOR 3 NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Make: FLUKE
Model: FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
13 Jul 2018, 10:00 amClosed
power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase
Three phase Number of Current Channels (Nos.) 3 1
2
3
4 Number of Voltage Channels 4 1
4 Measurable voltage range 1000 600
1000 Measurable voltage accuracy 0.2 0.04
0.1
0.2
0.5
1 Measurable voltage resolution 0.1 1
0.1 Measurable current range (with clamp) 2000 2000.0 Measurable current accuracy (%) ±1 ±0.04
±0.1
±0.2
±0.5
±1 Measurable current resolution 1 0.1
1
10 Maximum power that can be measured (KW) 400 4
40
400 Power Accuracy (%) ±1.5 ±1.5
±2
±2.5 Power resolution 1 1
5
50
500 1/5 MEASUREMENT FEATURES Facility to Measure Frequency Available - Frequency range that can be measured 40-65 Hz - Facility to Measure Inter harmonics Available - Order(n) to which Facility to Measure Harmonics available upto 50th - Facility to Measure Power Factor Available - Accuracy in measurement of Power Factor (%) 0.1 - Facility to Measure Distortion Factor Available - Accuracy in measurement of Distortion Factor (%) 2 - Facility to Measure Ripple Factor Available - Accuracy in measurement of Ripple Factor (%) 2 - Facility to Measure crest factor Available - Measurable crest factor range 1 TO 10 - Measurable crest factor accuracy (%) 2 - Measurable crest factor resolution 0.01 - Facility to Measure sag(dips) and swell(surge) Available - Pattern of measurement of sag(dips) and swell(surge) value - Facility to Measure Total Harmonic distortion Available - Accuracy in measurement of Total Harmonics distortion 2 - Facility to Measure voltage and current unbalance Available - 2/5 Facility to Measure inrush current Available - Facility to Measure flicker Available - DISPLAY Display type LCD Backlit - Display Mode Bar graph
Vector
digital reading - GENERAL FEATURES Facility to Measure RMS Voltage Available - Facility to Measure RMS Current Available - Facility to Measure Active
Reactive and Apparent Power Available - Facility to Measure Active
Reactive and Apparent Energy Available - GENERIC Data transfer software provided for analysis on PC Yes - Provision for external SD Card yes - Interface LAN
USB - Internal Memory (GB) 4 - Weight of the analyser 1.3 - other features Fluke Connect® compatible: View data locally on the instrument
via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure - POWER SOURCE/BATTERY Power Supply Battery operated
230 V AC +/- 10%
50Hz - If battery operated
chemistry of the rechargeable battery lithium ion - Voltage of rechargeable Battery 12 - capacity of rechargeable battery (milli AH) 0.01 - Suitable charger adaptor provided yes - Battery backup (hours) 2 - 3/5 OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 50 - Operating Humidity (%) 90 - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser Energy Logger
Basic version (excludes current probes) Power supply Voltage test leads Alligator clips (4x) Soft case - SAFETY Compliance to IEC 61000-4-30 Yes - Category of safety rating Category IV 1000 V of IEC 61010 - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes - conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes - Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Yes - Test Report Number and date 352145 & 12.10.17 - Name and address of the Lab FLUKE USA - * Bold specifications are the golden parameters. Consignees and Quantity 4/5 S.No. Consignee Address Quantity Delivery Days 1 Gaurav Dubey 345001
Air Force Station Jaisalmer(Raj) 1 30 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 14
248084
GEM/2018/B/35275
power quality analyzers
30 days
Rajasthan; Jaisalmer
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase | - | - | - |
| Three phase Number of Current Channels (Nos.) 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Number of Voltage Channels 4 1 | - | - | - |
| 4 Measurable voltage range 1000 600 | - | - | - |
| 1000 Measurable voltage accuracy 0.2 0.04 | - | - | - |
| 0.1 | - | - | - |
| 0.2 | - | - | - |
| 0.5 | - | - | - |
| 1 Measurable voltage resolution 0.1 1 | - | - | - |
| 0.1 Measurable current range (with clamp) 2000 2000.0 Measurable current accuracy (%) ±1 ±0.04 | - | - | - |
| ±0.1 | - | - | - |
| ±0.2 | - | - | - |
| ±0.5 | - | - | - |
| ±1 Measurable current resolution 1 0.1 | - | - | - |
| 1 | - | - | - |
| 10 Maximum power that can be measured (KW) 400 4 | - | - | - |
| 40 | - | - | - |
| 400 Power Accuracy (%) ±1.5 ±1.5 | - | - | - |
| ±2 | - | - | - |
| ±2.5 Power resolution 1 1 | - | - | - |
| 5 | - | - | - |
| 50 | - | - | - |
| 500 1/5 MEASUREMENT FEATURES Facility to Measure Frequency Available - Frequency range that can be measured 40-65 Hz - Facility to Measure Inter harmonics Available - Order(n) to which Facility to Measure Harmonics available upto 50th - Facility to Measure Power Factor Available - Accuracy in measurement of Power Factor (%) 0.1 - Facility to Measure Distortion Factor Available - Accuracy in measurement of Distortion Factor (%) 2 - Facility to Measure Ripple Factor Available - Accuracy in measurement of Ripple Factor (%) 2 - Facility to Measure crest factor Available - Measurable crest factor range 1 TO 10 - Measurable crest factor accuracy (%) 2 - Measurable crest factor resolution 0.01 - Facility to Measure sag(dips) and swell(surge) Available - Pattern of measurement of sag(dips) and swell(surge) value - Facility to Measure Total Harmonic distortion Available - Accuracy in measurement of Total Harmonics distortion 2 - Facility to Measure voltage and current unbalance Available - 2/5 Facility to Measure inrush current Available - Facility to Measure flicker Available - DISPLAY Display type LCD Backlit - Display Mode Bar graph | - | - | - |
| Vector | - | - | - |
| digital reading - GENERAL FEATURES Facility to Measure RMS Voltage Available - Facility to Measure RMS Current Available - Facility to Measure Active | - | - | - |
| Reactive and Apparent Power Available - Facility to Measure Active | - | - | - |
| Reactive and Apparent Energy Available - GENERIC Data transfer software provided for analysis on PC Yes - Provision for external SD Card yes - Interface LAN | - | - | - |
| USB - Internal Memory (GB) 4 - Weight of the analyser 1.3 - other features Fluke Connect® compatible: View data locally on the instrument | - | - | - |
| via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure - POWER SOURCE/BATTERY Power Supply Battery operated | - | - | - |
| 230 V AC +/- 10% | - | - | - |
| 50Hz - If battery operated | - | - | - |
| chemistry of the rechargeable battery lithium ion - Voltage of rechargeable Battery 12 - capacity of rechargeable battery (milli AH) 0.01 - Suitable charger adaptor provided yes - Battery backup (hours) 2 - 3/5 OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 50 - Operating Humidity (%) 90 - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser Energy Logger | - | - | - |
| Basic version (excludes current probes) Power supply Voltage test leads Alligator clips (4x) Soft case - SAFETY Compliance to IEC 61000-4-30 Yes - Category of safety rating Category IV 1000 V of IEC 61010 - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes - conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes - Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Yes - Test Report Number and date 352145 & 12.10.17 - Name and address of the Lab FLUKE USA - * Bold specifications are the golden parameters. Consignees and Quantity 4/5 S.No. Consignee Address Quantity Delivery Days 1 Gaurav Dubey 345001 | - | - | - |
| Air Force Station Jaisalmer(Raj) 1 30 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 14 | - | - | - |
Exempted
13 Jul 2018
25 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_248084.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .