Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹35.8 L+₹2.5 L (7.45%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹36.1 L+₹2.8 L (8.34%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹37.7 L+₹4.4 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹46.0 L+₹12.7 L (38.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
8 Feb 2020, 6:00 pmClosed
GE KAPURTHALA
GE KAPURTHALA
PROVN OF CERTAIN SANCTIONED LBW, SPECIAL REPAIR, REV WORKS AND MINOR WORKS AT MIL STATION BEAS AND JANDIALA GURU UNDER GE KAPURTHALA
2020_MES_316293_1
GE KPT-73/2019-20
Open Tender
Civil Works
Item Rate
270 days
KAPURTHALA
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE KAPURTHALA
₹99,000
Yes
12 Mar 2020
18 Jan 2020
10 Feb 2020
18 Jan 2020
8 Feb 2020
21 Jan 2020
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-In-Charge.
Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames), complete all as specified and directed by Engineer-In-Charge.
Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames), complete all as specified and directed by Engineer-In-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thicknness, including cover fillets, complete all as specified and directed by Engineer-In-Charge.
Dismantling framed trusses of span not exceeding 10m,complete all as specified and directed by Engineer-In-Charge.
Dismantling structural steel work such as purlins, rafters including doors, gates but excluding framed truss etc, complete all as specified and directed by Engineer-In-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed by Engineer-In-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness below or above ground level including tiles, terrazzo/stones etc, complete all as specified and directed by Engineer-In-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc , complete all as specified and directed by Engineer-In-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engineer-In-Charge.
-Ditto- all as per item No 11 above but except bricks etc, complete all as specified and directed by Engineer-In-Charge.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan to any radius built in CM 1:4 as in half brick thick walls, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and fair, complete all as specified and directed by engr-in-charge.
M&L for 10mm thick Rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick Rendering in CM 1:6 on brick work or concrete surfaces finished even and fair for fixing of wall tiles etc, complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge.
M&L for 15mm thick rendering in CM 1:4 on brick work or concrete surfaces with liquid water proofing compound, finished even and smooth without using extra cement etc including neeru finish to plastering complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.
M&L for 15mm thick Rendering in two layers(10mm+5mm) in CM 1:4 on other than fair faces of brick work and finishing surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and distempering walls with two coats of distemper oil emulsion, white or tinted over one coat of primer with and including 1mm thick wall care putty including primer, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces and applying two coats of white wash on walls etc, complete all as specified and directed by Engineer-In-Charge.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm, 1.25 thick sheet single rebated comprises glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B-1 Four Nos for each window including following fitting welded to frame shutter : (a) Hold fast, 150mm long of 12mm square bar made to shape-04 Nos per window (b) Handles of z section 100mm long (c) Stopper - 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges - 01 No per leaf (e) MS Pintal hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (f) Fabrication & fixing arrangement as per drg No CEJZ/TD-7/07 sheet 1/3 to 3/3. Note : Glass and painting shall be measured and paid separately under appropriate item etc, complete all as specified and directed by Engineer-In-Charge.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm, single rebated comprises gauzed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:3:6) type C-1 Four Nos for each window including following fitting welded to frame shutter : (a) Mild Steel Hold fast, 150mm long of 12mm square bar made to shape-04 Nos per window (b) Handles of z section 20mm x 100mm long (c) Stopper - 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges - 01 No per leaf (e) MS Pintal hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note : Wire mesh and painting shall be measured and paid separately under appropriate item etc, complete all as specified and directed by Engineer-In-Charge.
S&F Steel Ventilator 1.25mm thick Box Type fixed type prepared for fixing of gauzed and glass ( primer coated) ERW hollow P section of size 60mm x 25mm including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each vent ) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per vent (b) Handles of Z Sec 20mm x 100mm long (c) Stay (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Wire mesh/glass pane and painting shall be measured and paid separately under appropriate item etc, complete all as specified and directed by Engineer-In-Charge.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wooden beads to steel windows/wooden doors, complete all as specified and directed by Engineer-In-Charge.
S&F 2nd class HW 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer-In-Charge.
S&F 2nd class HW 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel barrel tower bolts 200mm long, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel pressed handles of size 150mm, oval type, stove enamelled black, complete all as specified and directed by Engineer-In-Charge.
S&F Butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Aluminium handles, cast type anodised of size 125mm etc, complete all as specified and directed by Engineer-In-Charge.
S&F Aluminium anodised barrel tower bolts of extruded section of 125mm size etc, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge.
All as per item No. 37 above , but over and including a coat of red oxide primer, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new wood surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed by Engineer-In-Charge.
S&F anodised aluminium snap grid of size 605 x 605mm in frame work for false ceiling, complete all as specified and directed by Engineer-In-Charge.
S&F for providing and fixing Gypsum Board 8mm thick of size (600x600)mm in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed by Engineer-In-Charge. (frame work for ceiling shall be measured and paid separately).
Erection and fixing only steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. Complete all as specified and directed by Engineer-In-Charge. (Old truss taken down shall be reerected and fixed)
Erection and fixing only steel tubular work as in purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed by Engineer-In-Charge. (Old purlins & rafters taken down shall be reerected & fixed)
M&L for mild steel framed work of angle or any other section confirming to Fe-290 Gde E-250 quality `B' as in door and door frame, threshold, holdfasts, gates etc of angle frame work etc including cutting, bending & necessary welding et. Complete all as specified and directed by Engineer-in-Charge.
M&L for Fe 410-W(Gde-E-250) quality-A rolled steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed by Engineer-in-Charge.
M&L for hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in plinth protection finished even and fair (without using extra cement), complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 Type B-1 ( using 20 mm graded stone aggregate) as in bed blocks, coping, benching in roof kerbs, etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) as in coping, benching, kerbs or mud stops, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:2:4 type B-1(Using 20mm graded stone aggregate) as in parapets, wall copings including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for chequered cement concrete tiles 20cm x 20cm & 25mm thick, set, jointed and pointed in neat cement slurry in floors/path with grey cement and no pigment to match, over and including 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6. Complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 57 above but as in skirtings over and including 10mm thick cement plaster in cement mortar (1:4). Complete all as specified and directed by Engineer-in-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as specified and directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick cement screed base in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish, complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 60 above but except stone, complete all as specified and directed by Engineer-in-Charge.
M&L for kota stone slab 20-25mm thick fixed in riser of steps, skirtings, dado and pillar, laid over and including 15mm thick cement screed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish, complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item No 62 above but except stone, complete all as specified and directed by Engineer-in-Charge.
M&L for grinding and polishing the old kota stone flooring/skirting with machine grinder and treating the surface with bees wax polish, complete all as specified and directed by Engineer-in-Charge.
S&F harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for steel tubular work as in purlins, rafters, etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1998 grade St.-240, complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete cast in situ Type B-1, 1:2:4 ( 20 mm graded stone aggregate) as in lintels upto 1.5m clear span including necessary formwork complete all as specified and directed by engr in charge.(Note : Reinforcement shall be measured and paid separately)
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to. Complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 68 above but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders, complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5 m depth for foundation & getting out , complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in loose / soft soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25cm for soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Excavation over areas not exceeding 1.5m deep and getting out in soft/loose soil, complete all as specified and directed by engineer-in-charge.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed of a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type D2, 1:4:8(40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete type B2, 1:2:4 (40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work in framed tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. Complete all as specified and directed by Engineer-in-Charge.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe:410-W(Gde-E-250) quality-A, complete all as specified and directed by Engineer-in-Charge.
Surface dressing not exceeding 15cm deep and getting out in soft/loose soil,complete all as specified and directed by Engineer-In-Charge.
M&L for soling with broken boulders or quarried stone (granite/trap/basalt) 100mm spread thickness, interstices filled, surface formed and rolled and consolidated to required gradient and camber, complete all as specified and directed by Engineer-In-Charge.
Supply & lay sand as filling under floors or in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick plain cement concrete type D2, 1:4:8(40mm graded aggregate) as in sub base of floor, complete all as specified and directed by Engineer-in-Charge.
Supply & lay machine pressed precast conctete interlocking paver block, 80mm thick, any shape and size confirming to IS 15658-2006, M-40 Grade, with grey cement and no pigment, complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore (broken bricks) of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type E-2 1:5:10 (40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in pavement/hard-standing finished even and fair without using extra cement including necessary form work and to divide the the area in panels, complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregatge) laid over well consolidated/rammed earth as in sub base, complete all as specified and directed by Engineer-in-Charge.
M&L for 150mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in sub base floor, complete all as specified and directed by Engineer-in-Charge.
M&L for stone sett flooring with stone sett of size 200 to 250 mm long, 150 to 200 mm wide and 150 mm deep and sides dressed bedded in CM 1:3, 20 mm thick, jointed grouted in cement mortar 1:2 with an admixture of metalic floor hardener 5% by weight of cement and struck flush, complete all as specified and directed by Engineer-in-Charge.
Rolling and consolidating road formation surfaces with 8 to 10 tonne power road roller, including watering as necessary filling in hollows and depressions to required true gradient and camber, complete all as specified and directed by Engineer-in-Charge.
M&L for 150mm thick (compacted) WBM with coarse aggregate grading (63mm to 40mm size) using quartzite/ flint stone etc blinded with stone screening type ‘A’ spread, rolled & consolidated with 8 to 10 tonne power road roller to require camber and gradient, complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centi- metre in field using 400 kg of cement per cubic metre, thickness of concrete 15 cm laid in two layers of 75mm each, complete all as specified and directed by Engineer-in-Charge.
Forming 12mm thick Expansion joints for 150mm thick filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’thickness of slab, complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4 type B-1 in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound, complete all as specified and directed by Engineer-in-Charge.
Spreading, leveling, watering and well ramming in layers not exceeding 25cm for soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type C2 ,1:3:6 (40mm graded stone aggregate) in sub base, complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick PCC 1:2:4 type B-1 with 20mm graded stone aggregate as in flooring, finished even and rough to receive the topping layer, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick PCC 1:2:4 type B-2 with 40mm graded stone aggregate as in platform for urinal, finished even and rough to receive the topping layer, complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devicej with recessed bottom, jet spray, etc. Complete all as specified and directed by Engineer-in-Charge.
S&F low Level Flushing cistern PVC valveless syphonic action type, 10 ltrs capacity including supply pipe & fixing brackets of M.S. angle of size (25mmx25mmx3mm), 30 cm long in PCC (1:2:4) type B-1, block of size (10cmx10cmx10cm) on walls, etc. Complete all as specified and directed by Engineer-in-Charge.
S&F vitreous China Wash Basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc. Complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china bowl urinal flat back, size of 465 x 355 x 265mm white with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. Complete all as specified and directed by Engineer-in-Charge.
S&F chromium plated bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe fixed as in repairs including taking down old tap of any description, complete all as specified and directed by Engineer-in-Charge.
S&F pillar taps, cast copper alloy with capstan heads Chromium Plated, screwed down high pressure, with or without lettered with long screwed shanks and fly-nuts, screwed for iron pipe but fancy type and fixed etc complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm etc. Complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as per specification & drawing given in SSR 2004(Part-II). Etc. Complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width & stuck inside with solvent cement for stile and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc. Complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm, complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overlength of cover plate 150mm, complete all as specified and directed by Engineer-in-Charge.
M&L for coloured Non Skid Joint less ceramic tiles (non-skid) of size 400mm X 400mm & 7mm thick, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed including taking down old screed bed complete.
M&L for glazed ceramic coloured tiles 300x200mm & 7mm thick as in vertical surfaces set and jointed in neat cement slurry and jointed or coloured cement to match etc. Complete all as specified and directed by Engineer-in-Charge.
S&F angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (minimum weight 15mm - 90 gms), complete all as specified and directed by Engineer-in-Charge.
S&F garting doom 125mm dia with waste hole of PTMT (minimum weight 40 gms) etc. Complete all as specified and directed by Engineer-in-Charge.
S&F steel tubes medium grade bore of tube in 15mm galavanised with all fitting laid in trenches, walls, ceiling or laid in floors etc. Complete all as specified and directed by Engineer-in-Charge.
All as per item No 116 above but of size of 20mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 15m dia brass float valve, complete all as specified and directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls as a vent pipe, complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed by engr-in-charge.
S&F 110mm bore PVC (SWR) bends any radius provided with access door, complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door, complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) vent cowl, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) P trap 110/110mm bore, complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.
S&F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to steel pipe or union, 15mm bore dia of pipe, complete all as specified and directed by Engineer-in-Charge.
Use and waste formwork to sides and soffits of floor or roof beam haunchings, girders, bressummers, lintels, cantilevers shelves including supports, overhangs, etc also splays between floors and beams, etc. Complete all as specified and directed by Engineer-in-Charge.
Use and waste the formwork for soffits of slab and similar work, batter rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick cement concrete type C-2, 1:3:6 as in Subbase flooring, complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L for 10mm thick rendering in CM 1:3 as in skirting, complete all as specified and directed by Engineer-in-Charge.
M&L for coloured non skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 136 above but as in skirtings, complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete(nominal mix) type B0 1:2:4(12.5mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs,landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
Use and waste the formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete, complete all as specified and as directed by Engineer-in-Charge.
M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm gradedaggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
M&L for 40 mm thick Damp proof courses to horizontal or vertical surfaces in cement concrete 1:2:4, Tye B-0 including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
S&F openable anodised aluminum window made out of hollow extruded aluminum sections as mentioned below. Each Shutter of window having 01 Nos D type handles, 02 Nos aluminum tower bolts 200mm size, 02 Nos Stainless steel hinges on each shutter. Shutter to be glazed with 5mm thick, tinted glass and provn of anodised aluminium grill of size 25 mm x 25mm, 6mm dia , made out of matters or cages, lapped wire and fixed to aluminum frame work with U section and screws/other fixtures as required. fixed with glazing clips, rubber beading/gasket, anodised aluminum beading, screws complete Chowkat/Frame : 101.60 x 44.45 x 1.55 mm thick Shutter top and bottom rail : 85 x 44.45 x 1.55 mm thick Shutter verticle style : 85 x 44.45 x 1.55 mm thick
S&F openable anodised aluminum window made out of hollow extruded aluminum sections as mentioned below. Each Shutter 0f window having 01 Nos D type handles, 02 Nos aluminum tower bolts 200mm size, 02 Nos Stainless steel hinges on each shutter. Shutter to be gauzed with stainless steel wire gauge as required. fixed with glazing clips, rubber beading/gasket, anodised aluminum beading, screws complete Shutter top and bottom rail : 85 x 44.45 x 1.55 mm thick Shutter verticle style : 85 x 44.45 x 1.55 mm thick
S&F anodised aluminium frame powder coated with minimum thickness of powder coating 50 micron for doors, windows, ventilators with one or more rebates including joining cleat for fixing, hinges etc. complete all as specified. complete all as specified and directed. Note:- Prelaminated partical board and sheet glass/wiremesh shall be measured and paid for separately. Make:- INDAL/HINDALCO/JINDAL or equivalent as per IS.
S&F anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, handles, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. Complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium (die cast) body, in door closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and as directed by Engineer-in-Charge.
S&F 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in squares exc. 0.5 Sqm in each pane with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specified and as directed by Engineer-in-Charge.
S & F aluminium anodised barrel tower bolt of extruded section 150mm long (ISI marked), complete all as specified and as directed by Engineer-in-Charge.
S&F floor door stopper, overall length of cover plate 140mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-in-Charge.
M&L for 50mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) as in flooring, finished even and rough to receive the topping layer, complete all as specified and directed by Engineer-in-Charge.
M&L for light shade Virified Ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
-Ditto- all as per item No 153 above but as in skirtings complete all as specified and directed by engr-in-charge.
S&F Fe410-W(Gde-E-250) quality-A roof trusses (framed), trussed, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Complete all as specified and directed by engr-in-charge.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer - in - Charge.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in chajjas, complete all as specified and directed by Engineer-in-Charge.
Use and waste formwork to chullah hoods, Chajjas, troughs and similar items including edges, complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of internal dia 150mm set in cement mortar, complete all as specified and directed by Engineer-In-Charge.
Supply & lay 200mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collars,complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C-2 as in concrete bed to drain pipes for bore dia of 150mm including packing under, and haunching against the sides of pipes after they are laid and tested; in, complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type B-1, 1:2:4 (20mm graded stone aggregate as in surface channels and drains, complete all as specified and directed by engr-in-charge.
M&L for precast cement concrete type B-1, 1:2:4 as in cover slabs over drain/manholes etc. including necessary formwork, complete all as specified and directed by engr-in-charge.
M&L for construction of sokage well, excavation in any type of soil , foundation in PCC in 1:3:6, wall of honeycombed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM 1:4, RCC cover slab in M-25/SFRS cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.00m dia and 4.5m depth complete all as specified and directed by Engineer-In-Charge.
Taking down carefully aluminium point wiring on casing caping/through conduit (light fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc. Complete all as specified and as directed by Engineer-in-Charge
M & L for point wiring for one light or one fan point controlled by one switch or with one switch and regulator with PVC unsheathed single core multistranded copper conductor (FRLS) cable of size 1.5 Sqmm (nominal area) in and including PVC conduit 20 mm bore by cutting chases in wall by cutter and making good the surface in cm 1:3 and to the original specification and fnished & providing cast iron /pressed steel concealed terminal boxes including providing 3mm thick plastic laminated sheet cover (Hylem) including one run of PVC insulated copper conductor (FRLS) cable of size 1.5 sqmm with green insulation as earth wire and connected to earth dolly complete all as specified. (Switch/Socket outlet to be measured & paid for separately). Make of cable: Finolex/Anchor/Havell’s, complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 167 here in before but for 3 pin socket outlet 5 Amps on same board, complete all as specified and as directed by Engineer-in-Charge. .
All as per ser item 167 above but for 3 pin socket out let 5 Amps on independent board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 167 here in before but for 3 pin socket outlet 15 Amps on independent board with PVC unsheathed copper conductor cable of size 2.50 Sqmm including copper earth wire of size 1.50 Sqmm and connected to common earth dolly complete all as specified. (Switch/socket to be measured & paid for separately)
Supply & fixing switch piano flush type 5 Amp single pole one way, complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing switch piano flush type 15 Amp single pole one way, complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing socket outlet 5 pin 5 Amps flush type multipurpose.
Supply & fixing socket outlet multipurpose 2 in one, 3 pin 5/15Amps flush type, complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable FTL fitting 36/40Watt and S & F surface mounting energy saving LED tube light fitting/ Batten with LED T8 Tubelight with PC body, 1x20W, 230V , Cat Part No of Batten DMLN1LT8-16 & Cat Part No LT8-20-865-2 for LED T8 Tube light Make- Crompton or equivalent in Havells/Philips complete with all accessories, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 6 to 32 Amps 240 Volts, B Series Product Code CSMBS1B6 to CSMBS1B32 Make- C&S or equivalent in Havells/GE/ L &T/Legrand, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 32 Amps 240 Volts SPN , B Series Product Code CSMBS1B6N to CSMBS1B32N Make- C&S or equivalent in Havells/GE/L&T/Legrand), complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire and neutral link, 8 ways, 240 volts. ( Make- Havells/Legrand)/L&T, complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire and neutral link, 4 ways, 240 volts. ( Make- Havells/Legrand)/L&T, complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing ceiling rose surface bakelite 65 x 50mm three terminal complete all as specified and as directed by Engineer-in-Charge. Make – Anchor/Leader/Bajaj
Supply & fixing Angular lamp holder insulated body with back plate suitable for batten fittings including 1 x 9 W LED Lamp Make- Havells LED ADORE 9 W B22 WW 3 STAR LAMP Cat No LHLDEUEEMC8R009 or equivalent all as specified and directed by Engr in Charge.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated Make- Bajaj/Havells/Crompton or equivalent, complete all as specified and as directed by Engineer-in-Charge.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver Make- Bajaj/ Crompton/Havells, complete all as specified and as directed by Engineer-in-Charge.
Hanging only ceiling fan taken down vide Srl No. 175, and connecting up including provision of flexible copper conductor cable from ceiling rose / connector to fan and GI pipe/ steel rod, nuts, bolts, clamps etc as required at site all as specified and directed by Engr-in-charge.
Supply & fixing fan regulator electronic step type and making connections. (Make : Anchor/Leader/Bajaj), complete all as specified and as directed by Engineer-in-Charge.
M & L of earthing complete with galvanized steel earth plate trode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level connected to GI earth wire 4mm dia by means of bolts, nuts and washers (earth plate covered with charcoal dust and common salt in alternate layers) GI earth wire protected by galvanized steel pipe light grade of 15 mm dia upto switch board and connected to main switch board, including provision of 20mm dia GI tubing light grade watering pipe with funnel and wire mesh PCC earth pit (1:3:6) type C-1 covered with CI cover hinged with frame including excavation and earth work complete all as specified and shown in electrical plate No 5 of SSR Part I including testing on completion.
Disconnecting and taking out old u/s cable of service connection/sub main wire of any size and type from pole to DB's / Main switch, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement sub main wiring with two single core FRLS insulated cable with copper conductor stranded and sheathed of size 6 Sq mm in and including PVC conduit including 1 x 6 Sq mm FRLS copper earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Havells/Plaza/Indo Asian
Supply & Lay the brick as brick protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid lengh wise perpendicular to the axis of cable complete all as specified and directed, complete all as specified and as directed by Engineer-in-Charge.
Supplying, filling in trenches spreading, leveling sand cushioning 8 cm below and 15 cm above the cable for under ground cable, complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED bldg security light fitting 15 watt Powder coated pressure die cast aluminium compact LED security light including 1.5 mtr long 40 mm bore GI pipe mounting bracket made to shape for fixing on wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washers all as specified and directed by Engineer-in-Charge.Make- Crompton Cat Part No LSTS-15-CDL or equivalent in Bajaj/Philips/C&S/Havells : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion, complete all as specified and as directed by Engineer-in-Charge.
M&L for GI Pipe 'light grade' galvanized with all fitting laid in trenches/on pole/road crossing of size 40mm, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED Slim panel 40 watt recess mounting fitting having Edgelit LED Slim panel having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser, separate HPF driver, suitable for armstrong and grid ceiling Product code PMD0401004 Cat No PCGLP 2 x 2 40 40 , 4000K of Make- Polycab or equivalent in Bajaj/Havells/C&S/ Crompton, complete all as specified and as directed by Engineer-in-Charge.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or round of 10 sqmm cable, complete all as specified and as directed by Engineer-in-Charge.
S&F House service bracket (Hook type) complete with 3.0 Mtr long G.I pipe 40mm dia Med grade two Nos 90 degree bends, MS hooks and stay or guy, complete all as specified and as directed by Engineer-in-Charge.
G M BUILDERS 36
JOGRAJ CONSTRUCTION COMPANY
kaushal builders
MAAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .