Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC C O PULAK SAHA MAHAKAL PALLY SURYASEN PARK MAIN GATE SILIGURI 734001 DIST DARJEELING | JALPAIGURI | WEST BENGAL | 734001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.8 L+₹86,633 (2.12%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹42.0 L+₹1.1 L (2.75%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹42.5 L+₹1.6 L (3.84%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹43.0 L+₹2.0 L (5.01%)Rejected-Finance CHOWDHARY APARTMENT BLOCK II FLAT NO 7 3RD FLOOR PUNJABIPARA SEVOKE ROAD SILIGURI DIST DARJEELING 734001 | JALPAIGURI | WEST BENGAL | 734001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
6 Feb 2023, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
REPAIR TO LEAKAGE SEEPAGE OTM ACCN OF ZONE A AND B AT SEVOKE STN UNDER GE SEVOKE ROAD
2023_MES_575176_1
GE/SEV/80 of 2022-23
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹76,000
Yes
14 Feb 2023
16 Jan 2023
8 Feb 2023
16 Jan 2023
6 Feb 2023
31 Jan 2023
17 Jan 2023 - 26 Jan 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above GL) complete all as specified
M&L for 40 mm thick PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note :- WPC shall be measured and paid separately as supply only complete all as specified and directed
M&L for 50 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as sub base of flooring complete all as specified.
Roughening surfaces of existing roof treatment and taking out of old APP membranes and removing from site including cleaning and washing down with water to remove dust, etc and brushing neat cement slurry @3 kg/sqm complete all as specified and as directed by Engineer-in-charge.
M&L for providing, laying water proofing treatment over plastered surfaces of RCC roof shall be as under:- (a) The dried plastered surface of slab shall be painted with one coat of bituminous primer @0.4 liter/Sqm. (b) Over the primed surface a layer of APP based polymeric membrane minimum weight of 3 kg/sqm of approved manufacturer minimum 3mm thick, reinforced with polyster non woven fabric (weighing not less than 160gms/sqm) shall be laid by torch application method. The side over laps of membrane shall be minimum75mm and the end laps shall be minimum 100mm and sealing all overlaps and joints shall be done as per manufacturer's instruction. (c) The finished surface shall be given Aluminium paint @ 0.11 Kg/Sqm on APP as per manufacturer's instructions. Make:-M/S TEXSA INDIA LTD (MOPLY-FP) / M/S STP LIMITED (SUPER THERMOLAY) / IWL INDIA LIMITED (HYPERPLAS)/M/S Tiki Tar Danosa (India) Pvt Ltd (Hydro Stop)/M/s Supreme Bituchem India Pvt Ltd (Super Shield)
M&L for 10 mm thick rendering in CM (1:4) over RCC roof surface to receive roof treatment finished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instruction (WPC shall be measured and paid separately).
Supply only water proofing compound (integral) complete all as specified and directed.
M&L for Cutting grooves in brickwalls, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and diected.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and diected.
Dismantling timber scantling 40 Sqcm and over in section in any position as in framed works complete all as specified and directed.
M & L for 2nd class hard wood (SAL) in scantling clean sawn and fixed in position complete all as specified and as directed.
S&F rolled mild steel sections any type including hollow section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates FE -290 Gde E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width of grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness in roofs complete all as specified.
Dismantling asbestos cement (corrugated/semicorrugated, etc) sheets in roof coverings etc complete all as specified and directed
S&F pre- painted gavalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F pre- painted gavalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified.
M&L for brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Taking down cement plaster on brick wall/concrete surfaces etc including racking out joints hacking for key scrubbing down with water etc of any thickness including Dado any description complete all as specified and directed.
M&L for 15mm thick rendering on other than fair faces of brick or concrete surfaces in CM 1:6 and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 20 mm thick rendering on fair faces of brick or concrete surface in CM 1:4 in two layers of 10mm each using water proofing compound on top layer only including finishing the surface even and smooth complete all as specified and directed.(WPC shall be measured and paid separately)
M&L for rendering 5 mm thick in CM 1:3 as in ceiling, finished the surface even and smooth complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of weather resistance acrylic emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1mm thick wall putty all as specified and directed. .
Demolition of cement concrete (reinfoced) of any description and in any position and removing rubbish of premise complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia or securing with clips complete all as specified.
M&L for mild steel TMT bars 6mm to 8 mm dia , cut to length, bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia or securing with clips complete all as specified.
Use and waste formwork to chullah hoods, slabs, chajja, through and similar items including edges for flat complete all as specified and as directed.
M&L for RCC 1:2:4 type BI (using 20 mm graded stone aggregate) nominal mix as in fins, facias,chajja,lintel etc complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area exceeding 0.11 sqm but not excdeeding 0.18 sqm as in floor etc set and jointed in neat cement slurry and pointed complete all as specified and as directed
M&L for non skid coloured ceramic tiles of size 600x600x8mm thickness in floor set and jointed in neat cement slurry and pointed complete all as specified and as directed.
All as per item No 34 above but in striking complete all as specified.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 150 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 150 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F PVC (SWR) 110mm Junction (Single T) equal or un equal provided with access door complete all as specified and directed.
S&F PVC (SWR) 150mm Junction (Single T) equal or un equal provided with access door complete all as specified and directed.
S&F Plain, Aluminium sheeting 0.71 mm thick, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) including fixing clamps ISF 30x6 mm at prescribed distance complete all as specified and directed.
Dismantling wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified
S&F 605X605mm anodised aluminium snap grid frame work for false ceiling including 2.5mm dia mild steel wire galvanized class 3, @ 60cm centre to entre and fixed to steel or wooden member including 4mm thick non asbestos fibre cement boards fixed or laid/ inserted to aluminium frame work as in ceiling complete all as specified and directed. Note:- The size of aluminium main and croos tee shall be 40mm x25mm x2mm and size of angle shall be 25mm x 25mm x 2mm)
Taking up or down 15mm bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down 20 mm bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all specified and directed.
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all specified and directed.
Dismantling PVC water tank of capacity Exc 500 Litre and not Exceeding 1000 Ltr complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks of 1000 litre capacity double layer black in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed
S&F in repair stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed, complete all as specified and directed.
S&F in repair 15 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
Drilling holes as per specififed Depth of the surface. Fix the PVC and fix it with fosroc renderoc plug, rapid setting cement based plugging mortar. Injecting cement slurry admix with Fosroc cebex 100, Plasticised expanding grout admixture @ 0.225 Kg per bag of cement and Fosroc Nitobond SBR Latex, @ 5 Lites/50 Kg cement, through the prefixed nozzles under pressure using suitable grout pump to fill all possible pores complete all as specified.
Identify the cracksand construction joints , honeycomb areas, shall be chased open into 'U' groove shape and sealed with High strength, fiber based cementitious mortar, Fosroc Renderoc SP40. Providing and fixing 6-8 mm dia nozzle along the joints and honeycomb areas after proper surface preparation. The injection of conbextra EP10 through the nozzle till the refusal of the grouting materials complete all as specified.
Supply and applying concrete surface with single component, fibre reinforced shrinkage compensated, polymer modified structural grade repair mortar like Fosroc Renderoc SP 40 or equivalent at a thickness of 40mm. The repair mortar should have a compressive strength 45 N/mm2, flexture strength 7 N/mm2 and tensile strength 2.5 N/mm2 at 28 days complete all as specified.
Plaster : Providing and applying plastering with CM 1:4 mixed with Conplast WL Xtra (Integral waterproofing compound confirming to IS 2645) at the dosage of 200 ml/bag of cement over waterproofing system to a minimum thickness of 15mm as per site requirement. Fosroc Conplast WL Xtra complete all as specified.
Providing and laying micro concrete up to the required thickness (avg 60mm) as per site requirement on the designated area to the prepared slurry tight shutteing with proper shear conector and bonding agent where ever necessary, The fluid micro-concrete repair material shall be single component, cement based, renderoc RG or equivalent micro-concrete to which only the site-addition of clean water (and approved graded coarse aggregates where specified) shall be premitted. The micro concrete shall contain no metallic aggregateds, or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete in the flow able consistency should achieve a compressive strength of 50 N/mm2 after 28 days at 30 C as per BS 4551-80. The unrestrained expansion shall be between 1-4% as per ASTM C827-1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/mm@ @ 28 day. The micro concrete shall have a co efficient of thermal expansion 10-12 x 10-6/C & Thermal conductivity 1.5 W/m C the mixed density of micro concrete shall exceed 2100-2200 Kg/M3 at 21C
Providing & erecting sturdy H frames, other structural steel members for temporary nature back propping/ scaffolding as specified in the structural drawings or any other level as required for a specified period. Providing and fixing steel props with steel section & bracings to support beam, slab & adjacent areas of column etc. as per instruction and as directed by consultant etc complete. The scope should also include covering entire building portion to be dismantled safely incl providing necessary horizontal supports etc with column or beam and maintaining the same for the entire duration of works incl dismantling & taking away on completion of work from the site etc complete.The contractor shall submit the design for shuttering, staging, supporting etc for consultants review and comments complete all as specified and directed by the Engr-in-Charge.
Coving Treatment:Coving (50mm X 50mm ) to be done at all junctions with Nitobond SBR latex to be mixed with cement complete all as specified.
M&L for applying one coat of Aluminium paint on top of APP for heat resisting as per manufacturer etc complete all as specified.
M&L for screed bed or bedding layer of cement mortar 1:6, 20mm thick for laying floor finishes complete all as specified and as directed.
M&L for 10mm thick rendering in cement mortar 1:3 on other than fair face of brick work for laying tiles in vertical surfaces complete all as specified and as directed.
Raj Enterprise
D.D. BROTHERS
SRI SURAJIT SENGUPTA
ASSOCIATED TRADING CORPORATION
M S ALOK SAHA
M/S TARAN INFRACON
Engineers India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .