Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC AS PER TCR | |
| 2 | L2₹20.9 L+₹96,237.85 (4.83%)Rejected-Finance PANDANESWAR BARDHAMAN BARDHAMAN 713346 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713346 | L2 | Rejected-Finance REJETED AS PER TCR |
Tender Value
₹19.9 L
EMD Value
₹25,000
Closing Date
14 Oct 2022, 11:00 amClosed
GENERAL MANAGER, JHANJRA AREA
OFFICE OF THE GENERAL MANAGER, JHANJRA AREA, PO-LAUDOHA, BO, DIST. - PASCHIM BARDHAMAN, PIN-713385
Trans, install, necessary fabrication, commissioning trial run including the extension of one no. 1000mm width, 1x110kW, 550V, Single drive belt Conveyor along 76L from -4D to 14D for development of Panel-7 in R-VII seam at 3n4 incline, J.P. Colly.
2022_ECL_257105_1
ECL/GM/JNR/EnM/e-Tender/ 22-23/A2/34,Dt.20.09.2022
Open Tender
Miscellaneous Works
Item Rate
60 days
JHANJRA UNDERGROUND
Please refer Tender documents.
4 documents required · 4 mandatory
₹25,000
13 Feb 2023
23 Sept 2022
15 Oct 2022
23 Sept 2022
14 Oct 2022
24 Sept 2022
23 Sept 2022 - 3 Oct 2022
Amount
Transportation & installation of One no. 1000mm width, 1X110kW, 550V, single drive belt conveyor for a length of 103.5mtr from 76L/-4D to 76L/-1D in R-VII seam at 3&4 Incline, J.P.Colly
Transportation of the 1000mm width, 1X110kW, 550V Drive Head complete including gear box, motor(110kW/550V), base frame, couplings, bearing blocks, fencing etc from (14XD-15XD)/54L (R-VIIA) by haulage and installation at 76L/-3D (R-VII) with necessary fabrication job.
Transportation of Discharge Unit complete with girders, strike plate, chute plates, scrappers etc from (14XD-15XD)/54L (R-VIIA) by haulage and installation at 76L/-4D (R-VII) with necessary fabrication job.
Transportation of Loop take up Unit complete from (14XD-15XD)/54L (R-VIIA) by haulage and installation at 76L/[(-3D)-(-2D)] (R-VII) with necessary fabrication job.
Transportation of Tail End Unit complete with fencing from (14XD-15XD)/54L (R-VIIA) by haulage and installation at 76L/-1D (R-VII) with necessary fabrication job.
Transportation of 103.5mtr. 1000mm belt conveyor structure complete with stringer, foot stool, top bracket, top & bottom roller etc. from (14XD-15XD)/54L (R-VIIA) by haulage and installation from 76L/-4D to 76L/-1D, R-VII seam.
Loading, transportation, unloading & placing of one breaker (550 V/200A), starter (550V/110kW), LS unit from surface to 76L/-3D (R-VII) with help of haulage.
Transportation of 250mtr. 3.3KV grade 70 sq.mm. PVCDWA cable from surface after loading it on trolley and transport by haulage to 74BL/-7D (R-VII) and laying-hanging of this cable from 74BL/-7D (R-VII) ACB to 76L/-3D(R-VII) ACB.
Transportation of 210mtr. 1000mm width PVC belting from (14XD-15XD)/54L (R-VIIA) to proposed 76L tandem belt installation site (R-VII) with help of haulage.
Laying, lapping, Jointing & tensioning of this 210mtr. 1000mm width PVC belting
Transportation of pull cords with its cable, belt sequence cable, communication devices with its cable from surface to 76L tandem belt installation site (R-VII) for 103.5mtr. belt and laying-placing them from 76L/-4D to 76L/-1D in R-VII seam.
Transportation of 8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut from surface for establishment of GI wire signalling (2 wire with bobbin insulator at a spacing of 9mtr.) for 103.5mtr. belt and placing-fitting them from 76L/-4D to 76L/-1D in R-VII seam.
Testing, trial run, alignment & commissioning of this belt conveyor from 76L/-4D to 76L/-1D in R-VII seam.
Fourteen times extension of the proposed 76L tandem belt conveyor from 76L/-1D to 76L/13D for a length of 483 mtr. in R-VII seam of 3&4 Incline Unit, JPC.
Fourteen times dismantling of tail end unit complete for fifteen times 76L tandem belt conveyor extension from 76L/-1D (R-VII) to 76L/13D (R-VII).
Fourteen times transportation and installation of tail end unit complete for fifteen times 76L belt conveyor extension from 76L/-2D (R-VII) to 76L/14D (R-VII).
Transportation of 1000mm belt structures (i.e. foot stools, channels, brackets, top and bottom rollers etc.) for a length of 483 mtr. from (14XD-15XD)/54L (R- VIIA) to 76L tandem belt extension site by haulage and installation them from 76L/-1D to 76L/13D in R-VII seam during fourteen times 76L tandem belt extension. Each time belt extension is for a length of 34.5mtr.
Transportation of 966 mtr. 1000mm belting from (14XD-15XD)/54L (R-VIIA) to belt extension site of 76L (R-VII) tandem belt and laying, lapping, jointing & tensioning of this 966 mtr. 1000mm belting from 76L/-1D to 76L/13D in R-VII seam during fourteen times 76L tandem belt extension and trial run.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) for 483 mtr. belt from surface to 76L belt extension site and laying & fitting them during fourteen times 76L tandem belt extension.
Supply of Materials
Supply of DA Cylinders
Supply of Oxygen Cylinder
Supply of MS Nut + Bolt of 5/8" X 2"
Total impact of GST for the purpose of CTC
SWAPAN KUMAR AKHULI
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .