Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | ₹10.8 L Quoted ₹11.2 L | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER |
| 2 | L2₹11.7 L+₹52,026.66 (4.64%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | ₹11.7 L+₹52,026.66 (4.64%) | L2 | Rejected-Finance BEING L2 BIDDER |
| 3 | L3₹16.1 L+₹4.9 L (43.6%)Rejected-Finance STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | ₹16.1 L+₹4.9 L (43.6%) | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
6 Jan 2020, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIRS TO AC SHEET, ROOFING, FALSE CEILING, FLOORING, JOINERY AND CONNECTED WORKS AT HATTIGOR MILITARY STATION UNDER GE RANGIA
2019_MES_306413_1
8345/E8
Open Tender
Civil Works
Item Rate
180 days
HATTIGOR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE RANGIA
₹30,000
Yes
24 Jan 2020
13 Dec 2019
8 Jan 2020
13 Dec 2019
6 Jan 2020
28 Dec 2019
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x30x0.70mm with 4mm dia GI wire as suspender and including 4mm thick E-Board classic (decorative type) including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting, complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M & L for G I Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
M&L rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 10+5=15mm thick on other than fair faces of brick work or on one side of lathing in cement mortar 1:4, surface finished even and smooth without using extra cement using water proofing compound in top layers, complete all as specified and as directed by Engineer-in-charge. Note - WPC shall be measured and separately.
M&L rendering 10mm thick on other side of lathing in cement mortar 1:6 be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
Supply only integral WPC confirming to IS, complete all as specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings not exc. 15 cm thickness, complete all as per specified and as directed by Engineer-in-charge.
M&L for 100 mm thick cement concrete type B-2, 1:2:4 type (using 40 mm graded crushed stone aggregate) finished fair and even, complete all as per specified and as directed by Engineer-in-charge.
M&L 40 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in floors, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in footpath/ hard-standing / pavings / plinth protections, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for Glass dividing strips, 38 x 3 mm thick and inserted in position to confirm to design, complete all as per specified and as directed by Engineer-in-charge.
Dismantling Unframed timber scantlings 40 Sq. cm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sq. Cm in section, complete all as specified and as directed by Engineer-in-charge.
S&F second class hard wood plain fillets in rectangular or triangular in section, clean swan fixed with screws having sectional area exc.13 sqcm but not exc. 25 sqcm, complete all as specified and as directed by Engineer-in-charge.
S&F second class hard wood plain fillets in rectangular tringular in section, of sectional area exc. 6sqcm but not exc.13sqcm, complete all as specified and as directed by Engineer-in-charge.
Dismantling of timber boarding of any description fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
S&F 50 mm thick second class hard wood boarding with butt joints clean sawn fixed with nails in any situation (except flooring and skirting), complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 21 above but 20 mm thick boarding planed both sides.
M & L for 4m thick Asbestos Cement board of size fixed in ceiling, complete all as specified and as directed by Engineer-in-charge.
M & L for 4m thick Asbestos Cement board of size fixed in walls, complete all as specified and as directed by Engineer-in-charge.
S&F solid PVC wall paneling consisting of 5 mm thick PVC wood grain printed PVC sheet inclusive of solvent cement and fixing at site as per specification and directed in any position with screws, complete all as per specified and as directed by Engineer-in-charge.
S&F 5mm thick PVC sheet fillets of width 35mm for wall paneling inclusive of fixing on wall to make frame as per specifications and drawing, complete all as per specified and as directed by Engineer-in-charge.
M&L 2 mm thick veneered decorative ply wood, grade 1 with BWR resin with decorative face veneers on one face fixed with screws to timber frame work in stands, boards, partitions, shutters, etc. including taking down old unserviceable panels, complete all as per specified and as directed by Engineer-in-charge.
M & L 4 mm thick non Asbestos Cement Plain building boards, fixed to timber/aluminium frame work with screws in ceilings, complete all as per specified and as directed by Engineer-in-charge.
S & F anodised aluminium snap grid framed work for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long GI suspender, complete all as per specified and as directed by Engineer-in-charge.
Dismantling asbestos cement (corrugated or semi- corrugated) sheets in roof covering, complete all as per specified and as directed by Engineer-in-charge.
M&L for 6 mm thick asbestos cement sheet, corrugated, or semi corrugated sheets in roofs, walls etc. and fixed with L-type or J-type or cranked hook bolts, complete all as per specified and as directed by Engineer-in-charge.
Fixing only 6 mm thick asbestos cement sheet, corrugated, or semi corrugated sheets in roofs, walls etc. and fixed with L-type or J-type or cranked hook bolts, complete all as per specified and as directed by Engineer-in-charge.
M&L for 6 mm thick asbestos cement two pieces adjustable serrated ridge for corrugated, or semi corrugated sheets fixed with L-type or J-type or cranked hook bolts, complete all as per specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles including 15 mm thick screed bed or bedding layers in CM 1:4, complete all as per specified and as directed by Engineer-in-charge.
S&F Coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles including 15 mm thick screed bed or bedding layers in CM 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for glazed ceramic coloured tiles 300x200x6 mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match with the shades of tiles including 10mm thick screed bed or bedding layer of cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
S&F Vitrified ceramic tiles 10 mm thick of light shade (Square/rectangular) polished, area of each tile not exceeding 0. 36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match with the shades of tiles including 15 mm thick screed bed or bedding layers in CM 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for chequered cement concrete PU finish tiles 30cm x 30 cm x 25 mm thick in floor etc, set, jointed and pointed in neat cement slurry and pointed (grey cement & pigment) over 20mm thick screed bed or bedding layer of cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
Taking down chowkat or frame not exceeding 1.5 Sqm each (without taking off shutter from the frame), complete all as specified and as directed by Engineer-in-charge.
S&F 2nd class hardwood in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as per specified and as directed by Engineer-in-charge.
Taking down shutters of any description not exceeding 1 Sqm each complete all as per specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
M&L for 35 mm thick second class hardwood glazed and skeleton shutter for doors open rebated and prepared to receive glass, gauge etc. (without sash bar) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc. sizes of member as specified in SSR part I section & clause 8.24 (a), complete all as per specified and as directed by Engineer-in-charge.
S&F 2nd class hardwood 30mm thick glazed and skeleton shutter open rebated and prepared to receive glass gauge etc divided into square with rebated sash bars any number edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauge etc (size of members of shutters as specified in SSR Par –I section 8 Clause 8:24 (b)), complete all as per specified and as directed by Engineer-in-charge.
M&L for 35mm thick 2nd class hard wood, plain, framed panelled shutters (any number of panels) with panels of timber flat on both side (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers etc., complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
S&F soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, fixing in opening as per specification and drawing including taking down old unserviceable frame along with shutter, complete all as per specified and as directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for top rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, fixing in the frame at site as per drawing, complete all as per specified and as directed by Engineer-in-charge.
S&F anodised aluminium door using 96.6mm X 44.8 mm X 1.5 mm aluminium chowkhats, 84.0 x44.7mmX1.5mm section vertical styles and 101. 60X44.88X1.5mm rails mounted 04 Nos SS butt hinges 100 mm for each shutter with hydraulic door closer, mortice lock six lever vertical type mild steel 100 mm size, 02 Nos tower bolt 150 mm , sliding bolt 300 mm long 01 No, 200 mm 2 Nos door handles and fittings, bottom panel and top panel fixed with snap beading rubber of suitable size including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F anodised Aluminium sliding window and ventilator frame made up 62 mm /29.5 mm 1.5 mm thick aluminium section & shutter made up 38 mm / 20 mm/1.5 mm thick without sash bar aluminium section including all necessary joining cleats, hold fast, rubber gasket, anodised snap beading, anodised aluminium fittings, suitable aluminium handle and locking arrangment etc. including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F butt hinges 100 mm long medium weight, cold rolled mild steel, complete all as per specified and as directed by Engineer-in-charge.
S&F butt hinges 75 mm long medium weight, cold rolled mild steel, complete all as per specified and as directed by Engineer-in-charge.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F aluminium alloy 300mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy, complete all as per specified and as directed by Engineer-in-charge.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples, complete all as per specified and as directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as per specified and as directed by Engineer-in-charge.
S & F 3 mm thick Sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as per specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry, built in any cement mortar including all quoins, arches, pillars, etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zince coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zince coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of newly untreated wood or wood based surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coat of Synthetic Enamel paint over a coat of pink primer complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing AC wall board & applying two coats of white wash, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing AC ceiling board applying two coats of white wash, complete all as per specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S S.S. Construction
M/S KIRAN ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .