Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹39.4 L+₹2.0 L (5.39%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.8 L+₹2.4 L (6.45%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹40.6 L+₹3.2 L (8.52%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹41.0 L+₹3.6 L (9.63%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
9 Nov 2023, 6:00 pmClosed
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
ADDN ALTN TO ROOF FLOORING JOINERY INTERNAL WIRING CONNECTED WORKS IN BLDG NO T-94, T-95, PROVN OF WALL LINING IN OFFRS OF IW AND CHINA BRANCH OF HQ EC BLDG NO SM-17 AND TEMPORARY SHED FOR 20 NOS SCOOTER PARKING IN FRONT OF ADV HQ EAC OF GE FW
2023_MES_623940_1
8189/E8
Open Tender
Civil Works
Item Rate
120 days
GE(FW) Kolkata
Refer as per tender documents
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹68,000
13 Jan 2024
18 Oct 2023
10 Nov 2023
18 Oct 2023
9 Nov 2023
2 Nov 2023
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removing the rubbish off the premise, complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all quarries, arches pillars etc and removing off the site complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description in rafters, purlins and wind ties etc complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting of any gauge, thickness, including roof coverings, including stacking serviceable materials of re-use, complete all as directed.
Excavation in post holes each not exc 0.5 cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft /loose soil complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D2 using 40 mm graded aggregates in foundation filling and mass concrete complete all as specified and directed.
M & L for plain cement concrete (1:3:6) type C2 using 40 mm graded aggregates in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for brickwork with fly-ash old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M& L for brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separately as "Supply only".
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L 10 mm thick rendering on fair faces of concrete surfaces in cement mortar (1:3) as on ceiling finishing concrete surfaces even and smooth without using extra cement complete all as specified and directed
M&L for 25mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub bases of floors complete all as specified and directed.
S&F Vitrified coloured (light shade) Ceramic double charged tiles, 8 to 9 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exc 1.28 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and directed.
All as per item No 22 here-in-before, but as in skirting on vertical surfaces, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed..
M&L for coloured non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over laid screed bed 15 mm thick cement mortar 1:4 complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 450x300x7mm/ 600 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles and fixed over and including backing coat of 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L for granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Providing edge moulding to 18-20mm thickness of granite stone any description of counters vanities etc including machine polishing to edge to give high gloss finish etc complete all as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for structural steel work Fe 410-W (Gde-E-250) quality-A in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
M&L for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
M&L for 0.80mm thick plain galvanised mild steel sheeting, as in hips, valley gutters, drip and straight flashings (length and girth as fixed) for hangers etc., as in repairs, complete all as specified and directed.
M&L for cutting holes in brick wall exceeding half brick but not exc one brick thick walls for inserting hold fasts for mild steel grills and making good dismantled portion in cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) including necessary formwork and making good surfaces as per existing finishes complete all as specified and directed.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish out exc. 50m, complete all as specified and directed.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, in cement mortar 1:4, complete all as specified and directed
Making good under cills or over arches, lintels and bressummers. including all?pinning when necessary in cement mortar 1:4, complete all as specified and directed.
S&F 5 mm thick Toughened glass as in hinged doors, partitions, automatic doors and similar works including cutting to shape, drilling holes etc., complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm and not exceeding 4 sqm each and removing from the site complete all as specified and directed.
Taking down steel window frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame), all as directed
Taking down shutters of any description, area exc 2.00 Sqm each and re-fixing in the same opening after necessary repair like easing, etc complete all as specified and directed.
Supplying and installing uPVC- Sliding windows/doors made out of lead free green profiles having a worldwide presence with a GREENLINE mark having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weather ability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery in Its quality (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted, complete all as specified and directed.
(Note: The unit rate quoted by contractor excludes cost of glass and powder coated aluminium grill and includes all other connected accessories. Net opening will be measured for payment purpose. Glass and powder coated aluminium grill will be measured and paid separately under respective items)
Supplying and installing of uPVC- lower windows with bottom fixed made out of lead free green profile having a worldwide presence with a GREELINE mark with frame dimension of 58mm x 36mm for window with aluminium powder coated frame and glass beads for louvers with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weather ability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer shall have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of iron mongery in Ist quality (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles shall have a warranty of 20 years. The profiles shall conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and cost of scaffolding if required for fixing shall deemed to be included in the quoted rate complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both faces, Complete all as specified and directed.
M&L for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2, 4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core complete all as specified and directed.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F butt hinges, medium weight, stainless steel, 100mm complete all specified and directed
S&F 150mm extruded aluminium handles, fabricated type, anodised complete all specified.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all specified.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all specified.
S&F 250mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, Complete all as specified and directed.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, aluminium (die cast) body, suitable for door shutters of 851 to 1000 mm in width & weight between 61 to 80 kg complete all as specified and directed.
Supply and fixing 12mm thick plywood, grade BWR, type BB, fixed to timber frames with nails for ward robe/shelfs etc., complete all as specified and as directed.
Supply and fixing 19mm thick plywood, grade BWR, type BB, fixed to timber frames with nails for ward robe/shelfs etc., complete all as specified and as directed.
M&L 0.9 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified.
S&F 30mm wide Continuous (piano) hinges, brass, bright finish or electro galvanised, complete all as specified and directed.
S&F cast type ,polished bright brass handles 100mm long complete all as directed by the Engineer-in-Charge.
S&F cup board lock, 4 levers brass body, drawer graded 1 size 70 mm, complete all as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified.
S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:- a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled regular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity resistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84. b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile colour) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”.
(Item No. 60 Contd....) All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL MAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE)
Re-fixing of aluminium snap grid system using serviceable grid sections and ceiling board obtained from taking down of false ceiling including hanging arrangements with supporting hangar 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured separately)
S&F non asbestos fibre cement building board, 4mm thick, fixed to aluminium frame work with screw as in ceiling duly finished with two coats of oil bound distemper over a coat primer, complete all as specified.
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed.
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed and unreinforced concrete n exc 40mm thick (if required at site) carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris out of MD land, complete all as specified and as directed. (Note: Dismantling and refixing of the earth strip is deemed to be included in the quoted rate if any)
M&L for brushing cement slurry @ 2.75 Kg/sqm over cleaned roof surface prior to application of concrete complete all as directed by Engineer - in - charge .
M&L for providing PCC (1:2:4) type 'B-0' (using 12.5mm graded crushed stone aggregate) mixed with water proofing compound @ 200 ml per bag of cement, surface finished even and smooth without using extra cement including complete all as a specified and as directed. (NOTE: Water proofing compound shall be measured and paid separately)
M&L 15 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyester matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction.
S&F heat resistant roof/terrace ceramic tiles, of size 300 mm X 300 mm of minimum 9.5 mm thickness, white coloured with mineral composition for reflective thermal insulation with solar reflective index (SRI) > 0.90 on roof/terrace, laid over and including 20 mm thick screed bed in cement mortar 1:4 mixed with liquid water proofing compound @ 200 ml/50 kg bag of cement, applying cement slurry and scratching the screed bed for proper fixing of tiles, laying the tiles with 4-6 mm spacers, curing the tiles for 48 hours and subsequently filling and grouting the joints with mix of white cement & marble powder/grout powder in the ratio 1:1 including providing skirting upto 150 mm height along the parapet walls in the same manner but at an angle of 45 degree over screed bed in cement mortar 1:3 complete all as specified and as directed. (MAKE: JOHNSON, Model: Endura Cool Roof tiles / AGL Model: Cool White / ORIENT/ BELL/ SOMANY or similar model in other ceramic tiles makes specified in tender) (Note: Waterproofing compound shall be measured & paid separately)”
Taking up or down 15mm bore GI Steel Water Tubing including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
All as per item No.71 above, but 20mm bore GI Tubing.
Supply, Laying and testing of 15mm bore Steel Water Tubing, Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and directed.
Supply, Laying and testing of 20mm bore Steel Water Tubing, Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and directed.
Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 1000 litres and providing necessary connections complete all as specified and as directed.
S&F 25 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-153 or equivalent model in JEXON / POLYTUF / SHAKTI)
S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043)
S&F Chromium plated brass Bib cock with wall flange, fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: FUS-29037 / CERA, Cat No: F1015151/ PRAYAG, Cat No: 9306-N/HINDWARE, CAT No: F360004 /PARRYWARE, Model: CLARET)
S&F Chromium plated brass self closing pillar tap (premium quality), fancy type. with aerator, fixed to wash hand basin, as in repairs, complete all as specified and directed. (Make : JAQUAR, Cat No: OPP-15001PM / CERA, Cat No: F1005101/ ASIAN PAINTS, Cat No: SRPC101 / HINDWARE, Cat No: F360001 / PRAYAG, Cat No: 8102 or equivalent model in PARRYWARE)
S&F in repairs, Tubular towel rail (premium range), 20mm dia, 600 mm long between flanges including brass chromium plated, complete all as specified and directed. (MAKE : JAQUAR, Cat No : ACN-111SM / PARRYWARE, Cat No : T6401A1 / CERA, Cat No: F5004103 / PRAYAG, Cat No: BA-20 / HINDWARE, Cat No: F840013 )
S&F chromium plated Hand shower (health faucet), ABS body with 1.2 metre long flexible tube in chrome finish with wall hook, as in repairs, complete all as specified and directed. (MAKE : JAQUAR, Cat No : ALD-CHR-593/ CERA, Cat No: F8030401AB / CERA, Cat No: F8030401AB / HINDWARE, Cat No: F160013 or equivalent model in PARRYWARE)
S&F in repair 15mm bore chromium plated two way bib cock with flange, fancy type complete all as specified and as directed. (Make : Ess Ess, Cat No: C-203 / JAQUAR, Cat No: CON-041KN/ PARRYWARE, Cat No: G1434A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9212/HINDWARE, CAT No: F330004CP).
S&F in repairs toilet paper holder, surface type with flap incl taking down existing holder complete all as specified and directed. (Make : JAQUAR, Cat No : CAN-1153N / CERA, Cat No: F5007110 / PRAYAG, Cat No: BA-38 / ESS ESS, Cat No: AC-506 / HINDWARE, Cat No: F880003).
S&F in repair vitreous China floor mounted coupled closet (Pedestal pattern) white including low level vitreous China valveless symphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC coloured seat cover and connecting fittings including taking down existing water closet complete all as specified and directed. (Make-JAQUAR / CERA / HINDWARE/PARRAYWARE)
S&F Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long,(As per sample as approved by GE) as in repairs, complete all as specified and directed.
S&F in repair Stainless Steel Sink with Drainage Board l.0mm thick Overall size 915mm x 460mm and Bowl size 410 mm x 355 mm x 165 mm for Kitchen or Laboratory with Plugs, Washers, Brass chromium plated Waste Fitting 32mm dia, PVC waste pipe, a Pair of Cast Iron Brackets duly Painted including Cutting and Pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including Taking down/out unserviceable Sink and connected Items, complete all as specified and as directed. Make : NIRALI/ Prayag or equivalent ).
S&F Vitreous china floor mounted coupled closet (Pedestal pattern) coloured including low level vitreous china valveless symphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC coloured seat cover and connecting fittings including taking down existing water closet complete all as specified and directed. (Make : PARRYWARE, Model : Cascade NXT / CERA, Model : CLAIR / HINDWARE, Model: CONSTELLATION or equivalent model in JAQUAR)
S&F in repair Plastic seat & cover, white, soft close type, for coupled water closet (of any description) incl chromium plated hinge complete all as specified and directed. (Make : PARRYWARE, Cat No: E8300 / PRAYAG, Cat No: 725 or equivalent model in JAQUAR / CERA / HINDWARE)
S&F 10 ltrs capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and incl with flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. (MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART or equivalent model in COMMANDER)
S&F in repairs Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON)
S&F in repair 32 mm bore PVC corrugated waste pipe, 800 mm long for wash hand basins complete all as specified and directed. (Make: PRAYAG, Cat No: 327 or equivalent make as approved by GE)
S&F 38/40 mm bore PVC corrugated waste pipe, 800 mm long for wash hand basins complete all as specified and directed. (Make: PRAYAG, Cat No: 327 or equivalent make as approved by GE)
S&F Chromium plated grating 102mm size fixed with white cement, as in repairs, complete all as directed. (Make : PRAYAG, Cat No : FT-04 or equivalent make as approved by GE)
S&F Vitreous China Wash Hand Basin counter top of size 550 x 450 x 200mm, white with waste coupling and necessary arrangements complete all as specified and directed. Make: Parrywae Cat No. C0431 Cascade NXT or equivalent model in Hindware/ Cera
S&F 100 mm dia CI floor/nahani trap, with grating including jointing to waste pipe, fixed in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregates complete all as specified and directed.
Dismantling of 100mm bore cast iron or reinforced concrete drain pipes, any dia, jointed in cement mortar and taking out of trenches or fixed on walls, complete all as specified and directed.
Dismantling of 150mm bore cast iron or reinforced concrete drain pipes, any dia, jointed in cement mortar and taking out of trenches or fixed on walls, complete all as specified and directed.
S&F 100mm bore Cast iron (sand cast) soil, waste and vent pipes, of any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F 100mm bore Cast iron (sand cast) soil, waste and vent pipes, of any length with or without ears with cement joints, fixed on walls, complete all as specified and directed.
S&F 150mm bore Cast iron (sand cast) soil, waste and vent pipes, of any length with or without ears with cement joints, fixed on walls, complete all as specified and directed.
S & F CI bend (any radius), diminishing pieces or tapers (larger bore measured) for 100 mm bore pipe complete all as specified and directed.
S & F CI bend (any radius), diminishing pieces or tapers (larger bore measured) for 150 mm bore pipe complete all as specified and directed.
S & F CI (sand cast) Branch pieces with ovel access door, single (any radius, equal or unequal) for 100 mm bore pipe for any building height complete all as specified and directed.
S & F CI (sand cast) sanitary connection socket to fit WC outlet for 100 mm bore pipe, complete all as specified and directed.
M&L for Stack clamps made out of 50mm x 5mm flat iron and 16mm dia round iron stay, including bolts and nuts and securing ends of stays to wall or roof for 100mm dia CI pipe, complete all as specified and directed.
M&L for Stack clamps made out of 50mm x 5mm flat iron and 16mm dia round iron stay, including bolts and nuts and securing ends of stays to wall or roof for 150mm dia CI pipe, complete all as specified and directed.
M&L for applying One coat of oil emulsion distemper with roller on old decorated surfaces of walls, including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
All as per item No.108 above, but on ceilings
M&L Preparing new plastered surfaces of Wall and applying 2 mm thick wall care putty over plastered surfaces, finishing surfaces even and smooth and applying two coats of oil emulsion distemper with roller over a coat of alkali resistant primer as per manufacturer's instructions, complete all as specified and directed.
All as per item No.110 above, but on ceilings
M&L for preparation of removed existing treated plastered surfaces of walls and applying 1 mm thick wall care putty over plastered surfaces, finishing surfaces even and smooth and applying two coats of oil emulsion distemper with roller over a coat of alkali resistant primer as per manufacturer's instructions, complete all as specified and directed.
All as per item No.112 above, but on ceilings
M&L for preparation of new surfaces of walls and soffit of chajjas, roof slab etc by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt, headgear etc, finishing the surface with 2mm thick exterior wall putty for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make, including necessary scaffolding for upto any height of building, complete all as specified and directed.
M&L for complete removal of existing treatment on walls and soffit of chajja, roof slab etc., of any description, over 10cm width or girth not otherwise described, by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blades/scrapper as applicable to make the surface free from protrutions, loose particles, dust etc., including necessary safety & protective measures such as safety belt, headgear etc., finishing the surfaces with 2mm thick exterior wall care putty (in two layers) for smooth finish and applying two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer with roller of approved make and necessary scaffolding for upto 4 Story building height, complete all as specified and directed by Engineer -in-Charge.
M&L for preparation of old painted wooden surface of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&l for preparation of old painted steel surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces exc 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces not exc 10 cm width or girth including preparation of surfaces complete all as specified and directed.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc excluding light fitting for reuse or removing from site and making good disturbed surface of walls, floors etc. Complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 122 above, but for one 5 Amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 122 above, but for one 5 Amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 122 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured separately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 126 here-in-before, but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 126 here-in-before, but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 126 above, but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuity wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
S&F new Call bell, musical type, AC 230/240 Volts, Single Pole
S & F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S & F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S & F Modular Bell push 6Amps, 1 module, complete all as specified and directed
S & F Modular Blank plate, 1 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 2 runs (P-N) of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 Sqmm 1100 Volts grade along with one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10 Sqmm 1100 Volts grade as earth continuity conductor drawn through and including adequate size PVC non-metallic concealed conduit, complete all as specified and as directed. (NOTE : Three runs of single core 6.0 Sqmm cable and one run of PVC conduit shall be measured as one unit)
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
S&F MCB SPN DB 8 way double door, IP-43 protection, isolated natural bar, insulated busbar assembly 200 Amps, mechanical impact strength of IK08 complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
S&F recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 35/36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Taking down carefully serviceable Old MCB DB any type any size including MCCB/RCCB/MCBs and serviceable MCBs and keeping in safe custody for reuse and refixing the same after repairs of civil works at site, complete all as specified and directed.
Taking down carefully serviceable Old ceiling/wall mounted fan of any sweep, complete with blades, down rods, regulator etc., and keeping in safe custody for reuse and refixing the same after repairs of civil works at site, complete all as specified and directed.
S&F PVC flexible pipe of size 100mm dia, with all accessories, such as clamps, screws etc., for covering of copper pipes outer side the wall, complete all as specified and directed.
Supply and draw wiring with one 4 Core 4 Sqmm PVC insulated copper cable 1100 Volts grade multi stranded from indoor to Outdoor unit duly properly connected with copper lugs of suitable size as per site requirement, complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/s Santosh Industrial Corporation
Rounaq Enterprise
M A ENTERPRISES
HARSH ENGINEERING
DGR CONSTRUCTION
M/S SRINIVASA CONSTRUCTION
MODERN AGENCY
M/S L.R.ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .